100 Days of Article 100: Equipment Grounding Conductor

  Рет қаралды 6,630

Ryan Jackson

Ryan Jackson

Күн бұрын

The definition of Equipment Grounding Conductor is covered here, as are the various types of EGCs recognized by the Code.

Пікірлер: 29
@intheskymusic
@intheskymusic 2 жыл бұрын
It's not just the material, but your experience that permeates through these videos that makes them invaluable. Thanks a lot bro.
@boeing757pilot
@boeing757pilot 3 ай бұрын
Another excellent video. I work for an electrical contractor when I'm off schedule. We always pull an equipment grounding conductor for redundancy. I like the "belt and suspenders" approach...
@electricalron
@electricalron Жыл бұрын
Ryan, I usually learn something I didn't know before watching one of your videos and this one is no different. I did not know about the MGM Grand fire being caused by an electrical ground fault condition. That's news to me. Thanks for relaying the message.
@elc2k385
@elc2k385 2 жыл бұрын
Very good. I learned about how paper covering in AC ia different from the plastic in MC, also learned about MCI-A connectors for the MC with the aluminum wire inside, and a bit about what a busway looks like. Also, about the flexibility stuff with the flex. Thanks, Ryan.
@garbo8962
@garbo8962 2 жыл бұрын
One thing I could never locate in NEC is the size of bonding wire that runs from a grounding bushing that only contains a ground wire. At the large hospital/ research center that I retired from 13.2 KV switchgear rooms might have up to 10 underground conduits only containing copper ground wires that all went to a 1/4" thick 4" wide by 2 to 3' copper buss bar. Some of the ground wires were at least 250 MCM but they only looped a #10 copper wire from all the grounding bushings to the copper buss bar. A few locations used #6 wire. Often thought they should have used a heavier wire. In Philadelphia they outlawed all aluminum ground wires ( 7/1981 ) so they never provided a clear answer with the use of using hospital type MC that contains a #10 aluminum ground wire. Contractors stated that the insulated green wire takes care of grounding.
@jirehelectric
@jirehelectric 2 жыл бұрын
Very nice video, i always run agreen equipment grounded conductor wheather are raceways or not. Can you make a video explanation of raceways.Auxiliary gutters some electricians say are ' raceways ', electrical boxes, switchgears because have busbars.
@alexsoanneso7873
@alexsoanneso7873 4 ай бұрын
On another level 💯 you got a follow here.
@royamberg9177
@royamberg9177 2 жыл бұрын
How many times have conduit came apart. Run a ground wire
@mr.g937
@mr.g937 2 жыл бұрын
Not to stoke up that debate...but I kind of like to think that it's the system that is grounded (per your solidly grounded video) more so than the individual devices and equipment...whereas the EGC (EBC?) does bonding first and foremost. The UK eschews both terms in favor of CIrcuit Protective Conductor (CPC)...which is certainly accurate, and does successfully avoid this controversy
@marcusmurphy5505
@marcusmurphy5505 10 ай бұрын
Thank you im an apprentice and this is so easily to follow great job sir.
@--JohnDoe
@--JohnDoe 2 жыл бұрын
Mr. Jackson. I trust noone, but the only two people I trust to decipher/explain the nec to me is You sir and Mr. Holt.
@RyanJacksonElectrical
@RyanJacksonElectrical 2 жыл бұрын
Thanks!
@chicagoflipsters6772
@chicagoflipsters6772 Жыл бұрын
You have more video about article 200 300 …? Just love your work ❤
@KhizarHayat87
@KhizarHayat87 2 жыл бұрын
Great video!
@JesusCruz-wt2zp
@JesusCruz-wt2zp 2 жыл бұрын
Please keep doing this videos, thanks
@MrMaxyield
@MrMaxyield 2 жыл бұрын
Informative as always. Thanks Ryan..⚡😎👌
@flipcy
@flipcy Жыл бұрын
Thanks for videos
@camoapajafa
@camoapajafa 2 жыл бұрын
Great video sir, Hope you're doind well Mr. Ryan. Thanks.
@sjain9383
@sjain9383 Жыл бұрын
You are awesome👍👍👍👍👍🙏🙏
@jimmiegill3981
@jimmiegill3981 2 жыл бұрын
Very nice video
@realvanman1
@realvanman1 2 жыл бұрын
This was an interesting one. I had not realized that the MGM fire was caused that way. What a freak accident. I have always taken that little bare aluminum ground wire and folded it back over the armor and wrapped it around, ultimately clamping it with the connector. Could that actually be construed as not allowed since it doesn’t “follow the manufacturer’s instructions”? Seems it can only be as good or better.
@RyanJacksonElectrical
@RyanJacksonElectrical 2 жыл бұрын
Usually the instructions allow what you describe or cutting off. I would cut it off, since that is the diameter of cable that the fitting is designed for. Adding the aluminum wire to the diameter of the cable probably wouldn't hurt, but it most definitely DOES NOT help.
@jimc3678
@jimc3678 2 жыл бұрын
At end of video. If EMT is going into an eccentric Knock Out in the raceway/gutter, Wouldn't a ground wire or bonding bushing be needed?
@RyanJacksonElectrical
@RyanJacksonElectrical 2 жыл бұрын
The wire would not be required, but a bushing could be. It depends on the voltage. Compare 250.96 and 250.97.
@pjmcinnis1188
@pjmcinnis1188 2 жыл бұрын
Hey thanks but I’m new to the trade and want to understand this.. I got confused on using the raceway as equipment ground. so you saying anytime I run emt, rmt,imt that I would not be required to run a green ground wire? so why do they do it? I worked around a lot emt and that’s all I’ve ever was taught.
@garbo8962
@garbo8962 Жыл бұрын
I had a lazy cut every corner chief electrician who never ran a ground wire when running EMT. A 1.25" EMT that he ran without a ground wire pulled apart at a coupling due to another trade played with conduit to snake a pipe between conduit & wall. When he was attempting to reinstall the conduit a 480 volt wire that got kicked touched the conduit ( ungrounded ) and got a severe shock along with chest pains. After that he started running ground wires. Like to have a solar for every time I came across an EMT conduit on set screw & compression fittings that were pulled out & corroded conduit .
@davidnobilese6124
@davidnobilese6124 Жыл бұрын
The same thing would have still happened if there was a ground wire in the conduit…
@boeing757pilot
@boeing757pilot 3 ай бұрын
Yes, if you're using those, you do not need a separate equipment grounding conductor because they will bond and carry fault current. We run an additional "green wire" for reduncy in case a coupling fails.
@realestateservicessaleshea99
@realestateservicessaleshea99 2 жыл бұрын
🍺🍺🍺🥃🥃🍇🏌🏻‍♀️ Stay safe.
Electrical conductor types in the NEC
28:03
Ryan Jackson
Рет қаралды 12 М.
Isolated power (ungrounded) systems (NEC 517.160)
14:51
Ryan Jackson
Рет қаралды 10 М.
Children deceived dad #comedy
00:19
yuzvikii_family
Рет қаралды 8 МЛН
Osman Kalyoncu Sonu Üzücü Saddest Videos Dream Engine 170 #shorts
00:27
Получилось у Вики?😂 #хабибка
00:14
ХАБИБ
Рет қаралды 7 МЛН
World’s Deadliest Obstacle Course!
28:25
MrBeast
Рет қаралды 159 МЛН
100 Days of Article 100: Grounded, Solidly
6:49
Ryan Jackson
Рет қаралды 6 М.
Grounding and bonding: Definitions and details
12:42
Eaton
Рет қаралды 83 М.
2020 NEC changes series: 110.14 Conductor Terminations
23:28
Ryan Jackson
Рет қаралды 80 М.
What Does Available Fault Current Mean?
7:53
Electrician U
Рет қаралды 40 М.
Most Common DIYer Electrical Mistake - Don't Let This Be You!
10:41
Everyday Home Repairs
Рет қаралды 3,7 МЛН
Собери ПК и Получи 10,000₽
1:00
build monsters
Рет қаралды 2,3 МЛН
Что еще за съемные фронталки от Vivo? #vivo
0:41
Как слушать музыку с помощью чека?
0:36