No video

250 volt Swimming Pool Disconnect Switch

  Рет қаралды 53,573

Electrical Industry Network

Electrical Industry Network

11 жыл бұрын

Sparky U Online has moved to
www.electricali...
I am not discussing amperage in this video.
When installing or repairing a 250v pool pump
switch make sure you install the correct type of
switch.
This video shows how some one used a stack switch
to control the pool motor.
The problem with the stack switch is that it only
shuts off one side of the power supply to the motor
leaving a hazardous situation at the pump motor.
The motor has windings, that if allowed,will carry
back voltage ,in this case,110 volts to the switch.
Both phases that make up the 220 volts required
need to be disconnected.
This video explains more about dpst toggle switches
and this • Electrical Wiring-Stac...
video explains more about stack switches.
Please rate and thumbs up the video if you like it
and subscribe for more videos from
Electrical Industry Network.

Пікірлер: 39
@Tac0b3llyfat
@Tac0b3llyfat 2 жыл бұрын
You are a Saint. I've probably watched over 15 different videos and none of them helped me understand like this one did. I now have the information I need to complete the job I was struggling with. Thank you so much! Subscribed.
@gojoe36
@gojoe36 11 жыл бұрын
It never ceases to amaze me what people come up with when wiring.
@Cagejujo
@Cagejujo 7 жыл бұрын
I can't believe some people, I work in the pool industry and run across your video (great explanation), this is really dangerous. Whoever did this deserves a shock in the balls.
@mikekeating1067
@mikekeating1067 10 жыл бұрын
Thank you so much, the way you use the mouse pointer to show exactly what was going on is VERY HELPFUL
@electricalindustry
@electricalindustry 10 жыл бұрын
Glad you like it. I get mixed feedback between making videos and doing a slide show. I try to mix them up a little!
@Trifecta3x3
@Trifecta3x3 5 жыл бұрын
Great info. I didn't think to check the switch to see if it was DPST. It was not. It is NOW! Thanks!
@TradieTrev
@TradieTrev 11 жыл бұрын
Phase isolation (as I would call it) is a requirement for our 415v equipment here in Australia too mate ;) Another easily avoided nasty situation!
@jamesclavelli7282
@jamesclavelli7282 7 жыл бұрын
Very clear and concise. You explained it so much better than the sites you 'ask and pay' Will follow for more education. Thanks so much.
@electricalindustry
@electricalindustry 7 жыл бұрын
Thank you James, I appreciate your comment!
@CNBarnes
@CNBarnes 9 жыл бұрын
Very solid video. It perfectly explained what I need in order to put a switch on my 220v window AC unit.
@electricalindustry
@electricalindustry 9 жыл бұрын
Chris Barnes Thanks,Glad it helped!
@skylarelctrican2317
@skylarelctrican2317 8 жыл бұрын
Looking Pretty solid yourself there Chis
@meerscan9101
@meerscan9101 7 жыл бұрын
are you going to make more videos? im quite sure abunch of guys would love to see another series
@yamspaine
@yamspaine 5 жыл бұрын
I too value this video, but beware, there are other considerations that are likely not covered by this video. I assure you that there are many many more ways to screw up an electrical installation.
@trespire
@trespire 10 жыл бұрын
Lock out Tag out procedure requires verification of Zero State condition, that includes no electrical energy, before starting servicing. Some one could easily have been electrocuted at the swimming pool by just touching the metal box holding the switch, does it have to be metal?
@isardriver
@isardriver 9 жыл бұрын
although my switch is for a steam humidifier, your explanation helped a lot. many thanks for posting
@electricalindustry
@electricalindustry 9 жыл бұрын
Thanks,glad it helped,I appreciate you watching and commenting on my video.
@thewizard112
@thewizard112 11 жыл бұрын
thanks i`m from uk its 240v as im sure you know but very intresting watching your videos with you working on 110v keep making them
@electricalindustry
@electricalindustry 11 жыл бұрын
I have read your question and I am not clear what your after. What is the circumstances that you are dealing with?Is this some sort of equipment that might have a main lug block that feeds all the motors?
@acropetal
@acropetal 11 жыл бұрын
Thank you, you might have save an electrician's life today.
@daf664
@daf664 6 жыл бұрын
Thank you! I corrected the crap job someone did in the past with this video.
@electricalindustry
@electricalindustry 6 жыл бұрын
Glad it helped!
@CaminoYVerdad1
@CaminoYVerdad1 11 жыл бұрын
What I am after is this, knowing that the NEC allows you to size your branch OCPD at 250% max for inversetime circuit breakers so in my case this would be 14 FLA X 2.5 = 35 (standard size) If I use this breaker what is protecting my conductors ampacity? Its only good for 20 A the breaker wont trip untill 35 A its only protecting for short circuits and ground faults Also the NEC say that a 14 AWG conducotr must be protected by a 15 A breaker, so in this case is i use a 35 A breaker should I use 8
@stevmoon
@stevmoon 11 жыл бұрын
Wow they would have been closer to code if they just run that extrnsion cord wire and pluged it in:>) BTW where's the GFCI for that pool pump?
@b2gills
@b2gills 11 жыл бұрын
You didn't mention that when the original switch is off, there is a combined 240V between the line and load sides of the switch. Which may be more than it was designed for.
@donmills2167
@donmills2167 Жыл бұрын
I believe that you misstated the dpdt switch at the end of the video.
@frederickwelsh
@frederickwelsh 9 жыл бұрын
Your video was very helpfiul.Thanks for putting up.
@electricalindustry
@electricalindustry 9 жыл бұрын
Thank you frederick glad it helped
@CaminoYVerdad1
@CaminoYVerdad1 11 жыл бұрын
Unless I size the breaker down and use 12 on a 20 A CB or a 10 on a 30 CB cuz thats what NEC says those conductors shall be protected by that CB raiting. obviously i can do that but lets say i didnt want to because i have lots of inrush current so i go with the max size 35 A CB do I use a number 8. Those are the questions what protects the 14 AWG wire with a 35 A breaker and should I use a number 8 for the 35 A CB this is all hypothetical.
@leexgx
@leexgx 11 жыл бұрын
This is related to 110v 2 phase to get 220v so dual pole switch should of been used, in places where 220-240v is the norm it only use single phase and a single pole switch would of been fine if that was the case (but it would of been IP rated due to it's location) , why this was done in this way is very poor and I am not a sparky and I understand how bad that is
@kameronlukey
@kameronlukey 8 жыл бұрын
does turning off one leg to a 220v pump cause any damage to the pump?
@stevenzembriski6761
@stevenzembriski6761 2 жыл бұрын
Yes it is like a brownout
@PilotPlater
@PilotPlater 11 жыл бұрын
great video. Been going through my crawlspace and trying to clean up lots of "handyman" jobs myself. It's comical to see the rainbow of different types of cables with sketchy grounding and spaghetti that's not secured properly.
@GalaXy808
@GalaXy808 11 жыл бұрын
I really need thus video sir
@CaminoYVerdad1
@CaminoYVerdad1 11 жыл бұрын
could someone checkout the discussion comments i poster a question there. thanks.
@brediaable
@brediaable 8 жыл бұрын
at first in the video you say you need a DPST and in the end you say DPDT but your diagrams were all that matters I think you just made a legitimate mistake
@CaminoYVerdad1
@CaminoYVerdad1 11 жыл бұрын
still confused?
@CaminoYVerdad1
@CaminoYVerdad1 11 жыл бұрын
so im guessing there isnt anyone knowledgeable enough on motor calcs to help hu. what about you sparky can you school me?
@hrdcoreme
@hrdcoreme 3 жыл бұрын
Hey friend your pretty condescending .. Obviously the person who wired it wasn’t electrician , they didn’t know better I bet they thought they were doing what is right ..I’m sure it was the homeowner that did the work. So if you would like people to do things like this right, keep putting information out for homeowners so they will have the info available because god knows you electricians $ $$$$ , cost an arm and a leg , and that’s why homeowners tackle more then they should. Don’t get me wrong you should make what your worth ,, so keep helping out thanks just less condescending towards people..
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,3 МЛН
Lehanga 🤣 #comedy #funny
00:31
Micky Makeover
Рет қаралды 28 МЛН
Parenting hacks and gadgets against mosquitoes 🦟👶
00:21
Let's GLOW!
Рет қаралды 12 МЛН
Smart Sigma Kid #funny #sigma #memes
00:26
CRAZY GREAPA
Рет қаралды 19 МЛН
Meet the one boy from the Ronaldo edit in India
00:30
Younes Zarou
Рет қаралды 12 МЛН
Basic Pool Electrical Wiring Module 2
38:40
Craig Wooster
Рет қаралды 68 М.
How To Add An External Electrical Disconnect To Your Home
57:34
Electric Pro Academy
Рет қаралды 336 М.
Circuit Breaker and Electrical Panel Basics
12:25
Everyday Home Repairs
Рет қаралды 502 М.
How to Extend Short Wires | Easy Fix Anyone Can Do
6:52
The DIY Guy
Рет қаралды 3 МЛН
No Room In Electrical Panel - Quick Fix
7:21
Everyday Home Repairs
Рет қаралды 1,2 МЛН
Motor Controls - Contactor and Power Circuit
13:18
IMAT
Рет қаралды 129 М.
Lehanga 🤣 #comedy #funny
00:31
Micky Makeover
Рет қаралды 28 МЛН