AC stop cooling after some time
App Link
play.google.co...
Join this channel to get access to perks:
/ @actechpro
My accessories
Camera - amzn.to/30EgcNK
Mic - amzn.to/3nAZx7A
Tripod - amzn.to/2GByxUB
Laptop - amzn.to/3ddN30L
Bluetooth Speaker - amzn.to/3lnbImA
Headphones - amzn.to/30H0i5g
Drill Machine - amzn.to/3dxItKO
Multi meter - amzn.to/3fKH2dr
KZfaq Channel
/ actechpro
follow our facebook page
/ actechshekhawat

Пікірлер: 302
@RJ-qs6pg
@RJ-qs6pg 2 жыл бұрын
Air in system....if not purged properly or vaccumed properly while charging refrigerant can also result in frequent high pressure trip of ac ...as air wil not liquify like refrigerant and wil put excess load on compressor...this usually happens on big central ac systems ... 12 th point ..nice video ...covered all technical points
@ACTechpro
@ACTechpro 2 жыл бұрын
Good added point ravi
@jitendragaur8319
@jitendragaur8319 Жыл бұрын
मेरा 1.5टन का वोल्टास का स्पलिनट ए सी है जो हमेशा ही जून के महीने मे कम्प़ैशर बार बार बन्द होता है
@statusbyjaggi8893
@statusbyjaggi8893 3 ай бұрын
Same problem bro same ac
@akashgoyal2636
@akashgoyal2636 2 ай бұрын
Same problem
@sandeepsinghyam7223
@sandeepsinghyam7223 2 ай бұрын
Seme ac seam problem
@rakeshdsouza166
@rakeshdsouza166 3 жыл бұрын
please make a video of How VRF unit working principle?
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
Zyada heat wala area jaha sun light direct ho ya fir zyada garmi ke sizen me for example march, April, may tab bhi compressor thodi Der heat hokar trip ho jate he
@Jyotichaudhary-0777
@Jyotichaudhary-0777 2 ай бұрын
Eska koi upaay nahi hai jisse hamara ac cooling kre
@ankitrajarya864
@ankitrajarya864 4 ай бұрын
Sir aaj he ac lagwaaya aur ac chalte chalte cool nho kr rha fir thoodi dher baad coolong kr rha outer bnd ho jaa rha fir start ho jaa rha log bol rhe. Voltage ki dikkat hai bt main circuit me staplizer laga hai 250 volt aa rha fir kyu aisa ho rha
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## outdoor unit me fan capacitor change Kiya ho to same value kaa Karna prega for example Samsung ke outdoor unit me 2.5mfd Ka capacitor change krke 3 ya 3.5 mfd Ka dalnese kuchh ser baad compressor band hojati he
@jagroopsingh4092
@jagroopsingh4092 2 жыл бұрын
Sir compressor ki registance kitni honi chaya 1ton ac and 1.5 ton split ac
@rinkigoel149
@rinkigoel149 2 жыл бұрын
Sir panasonic ka ac h Or vo evening ke 6 pm se le ker morning ke 9 am tak badiya chalta h But afternoon me vo chalta tho h but hot air detha h Ac wale ko dikhaya tho vo stabilizer change kerne ko bol reha h Aap ke points mughe ache lege Tho kya aap mughe iska reason betha sakthe ho
@lokeshzindgijeelo8308
@lokeshzindgijeelo8308 3 ай бұрын
Same problem
@shaikhsabir3828
@shaikhsabir3828 2 жыл бұрын
Bro caarier ac main indoor unit chalta h Or compressure m chalta h. Kuchh time 10 minute chalta h. Indoor unit autometic off ho jata h indoor unit display light blinking hota h continue 1 minute.fir 1 minute k baad light blinking off ho jata h fir indoor chalta h.or pcb new lagaya. Gas thik h. Jaisa timer set ki tarah hota h.
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## Purane models me ek case paya tha ki jab swing flapper motor jam Hoti he tab blower motor ki speed bhi Kam kardeti he uski Bina se coil thandi hokr sensor se compressor trip karwati he. Swing flapper motor kaa socket Nikal dene se compressor ok chalta he, reason wohi tha ki swing motor purani hone se jyada load le rahi thi.
@ravikantgadge260
@ravikantgadge260 Жыл бұрын
Sat 1 ton ac suruvat me 5 minit thand kar rahi hae. Fir nahi. Aur A 5 se .A 2.5 ho raha hae.. Plz .solution bataen
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## outdoor unit ka upper side Ka top laga hua naa ho, wo open ho tab bhi compressor thodi Der baad bnd hota he ese case me compressor khrab hone ke chances zyada hota he
@ramkrishna3884
@ramkrishna3884 Жыл бұрын
Mana ki compressor me ⛽⛽ r 32 ki jagha pe r22 koyi dala ho to
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## compressor Ka pumping agar Kam hota he tab bhi thodi Der me band hojata he. For example aap khali system me compressor chalate ho agar usme Aapka pumping 300 se 400 tak aata he to ok he warna isse Kam ho or back pressure speed se down hota he tab bhi Aapka pumping low he
@kumardinesh1990
@kumardinesh1990 2 жыл бұрын
Compressor me oil Kaisa dalenge
@technicalknowledge6917
@technicalknowledge6917 2 жыл бұрын
Too good video.
@Secretjocks
@Secretjocks 8 ай бұрын
Sir ac kabhi cooling kar rahi hai kabhi nahi kar rahi hai is topic ke upar video bana do or sir ac ki caplary or ac ki pipe kahi par bhi moisture choking ya oil choking ho to kaese findout kare ki ac me choking ki problum hai is topic par bhi video bana do plz sir - My name is Mohammad Adil
@guddumishra5655
@guddumishra5655 2 жыл бұрын
Very nice 👍🌹
@vijaykeshari5391
@vijaykeshari5391 27 күн бұрын
Sir je mitsubisi ka split a/c me stabilizer se wiar ulta lagane par koi problem hogi ya nahi
@Protech2015
@Protech2015 3 жыл бұрын
Sir refrigerant pressure zyada hone se bhi thodi der baad Compressor trip kar jata hai
@entrepreneur172
@entrepreneur172 3 жыл бұрын
Good
@ACTechpro
@ACTechpro 3 жыл бұрын
Point no 12 .Very good
@satishkirarsaxophone6727
@satishkirarsaxophone6727 Жыл бұрын
Bhaiya ji Hamare ISI mein बार-बार ch41 likha hua a raha hai aur calling cut rahi hai ham Kya Karen bataiye
@GayatriPailwar
@GayatriPailwar 2 ай бұрын
Sir meri AC panasonic ki hai aur vo kuch der chalti hai aur kuch der cooling karti hai phir band ho jati asa baar baar par karti hai mai kiya karu
@unzipstudybag4073
@unzipstudybag4073 2 ай бұрын
Ampere ki deflection hote hai garm hava dena shuru kar deta hai A. C. Plz tell me how to rectify it
@iia4815
@iia4815 2 жыл бұрын
sir me apne ac ko 28 pe set karta hu or ac room temp ko 29 pe laake outdoor band ho jata hai
@RajeevYadav-zy1cy
@RajeevYadav-zy1cy 2 жыл бұрын
Mera bhi yahi ho rha h
@gulzarilal7543
@gulzarilal7543 2 жыл бұрын
Thnks bhai
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## inverter AC ke outdoor unit me condenser Pura clean he magar PCB area me kachra yaa rust laga ho ya Kisi ne wiring box khula rakha ho jisse kabutar ya Kisi birds ya insects ne kachra jama Kiya ho tab bhi 2 se 5 minutes compreeser chal Kar band kardega
@soumendraprasadmohanty8469
@soumendraprasadmohanty8469 2 жыл бұрын
Bhai,unit start hone time compressor normal hoga,kuch time chalne ke bad, discharge pressure perfect hoga,Lekin suction reed problem se wo proper refrigerant suck karnehi payega,phir wo proper refrigerant discharge karega nehin, naturally cooling stop ho jayega,ampre below hote jayega . Reply jarur Dena bhai.
@hasmukhbutani1131
@hasmukhbutani1131 Жыл бұрын
Super duper sirji
@karmabauri1962
@karmabauri1962 2 жыл бұрын
Thanks sir
@ACTechpro
@ACTechpro 2 жыл бұрын
Your welcome
@mscooling9944
@mscooling9944 2 жыл бұрын
Asha test me koin koin se sawal puchhte hai plz ek full video banaye sir ji
@arshi2003
@arshi2003 2 ай бұрын
Mere Blue star 1.25T window ac ka temp. 28 se neeche nahi horaha hai...gas poor hai kahin leakage nahi hai
@AliAbbas-pf7qe
@AliAbbas-pf7qe Жыл бұрын
Good teacher
@ACTechpro
@ACTechpro Жыл бұрын
Thank you! 😃
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## outdoor unit ka fan jiska wiring kisine Ulta Kiya ho for example motor se fan garam hawa bahar fekne ki bajay andar fek raha ho tab bhi compressor thodi Der heat hokar trip karta he
@anoopyadav2920
@anoopyadav2920 6 күн бұрын
After running 2 to 3 hours out door fan is stop . Cooling is stop . After some time I start again than cooling is start What is the problem in my panosic inverter AC , please help me/guide
@rajkumarsyohi3265
@rajkumarsyohi3265 Жыл бұрын
Mera bindow a/c hai, ye ese chalta hai, lekin dopahar ko sound aata hai orculing band ho jati hai, night main chalta hai condensor bhi change kiya tha
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## remote me agar aap temperature celcius ki jagah par ferenheat rakhoge tab bhi compressor thodi Der me temperature aane se band hojata he
@mavjibhaipatel4596
@mavjibhaipatel4596 2 ай бұрын
Good videos 😊
@umeshrajpoot30
@umeshrajpoot30 2 ай бұрын
Mera blue star ka 1.5 ka ac h uska compressor kuch time chalne k bad trip ho jata h or indoor se garam hawa ane lagti or compressor dhere dhere chalta rahta h kuch time tak ism kya problem ho shakti h
@vipinmishra6949
@vipinmishra6949 2 жыл бұрын
सर जो ऐप आप बनाए हैं उसको इंग्लिश टू हिंदी ट्रांसलेट करें कृपया
@nishalalvani
@nishalalvani 2 ай бұрын
Sir hamara ac 2 ton ka h to Jab lae the tab to first day ko bahuthi Acha cooling ki this but uske second day se hi cooling kam hogai or jisse liyatha vo man hi nahi raha hai ki ac me koi khrabi h .
@tauquirkhan8541
@tauquirkhan8541 2 ай бұрын
Sar mera ek hi voltage 1.5 tan hai usmein ice a jata hai filter aur capillary change Kiya Hai Uske bavjud Fir se Ab Kya Karen
@praveenmalhotra159
@praveenmalhotra159 11 ай бұрын
Hitachi window AC works fine with fan Speed medium and low but trips at fan speed High. Any solution?
@nishanbhullar3718
@nishanbhullar3718 Жыл бұрын
Sir Hitachi 1.5 ton inverter hai par temperature pura hone pe cat nahi hota
@HiralalKharet
@HiralalKharet 2 ай бұрын
Sir ji mera split Ac ka pankha pehle se kam chal raha hai,or cooling bhi jyada nahi deta please batayein
@President_Vladimir_Putin
@President_Vladimir_Putin 2 ай бұрын
Okay I got it. Technician ko bulana hoga
@shahnawazkhan1382
@shahnawazkhan1382 2 ай бұрын
Cassette AC hai uska main sab kuchh ok gas bhi ok hai condenser heating bhi achcha Nikal Raha Hai per cooling nahin kar raha hai to kya problem ho sakta hai please batao bhai
@garden_lover15
@garden_lover15 Жыл бұрын
Hitachi inverter split AC ka compressor din me bar bar (20-25 sec bad) tip kar raha hai, or kuch der bad outdoor and indoor dono bandh ho raha hai 4 time blink ke saath. lekin raat me bilkul sahi chal raha hai. Iss ka Karan kaya hai...
@JoyfulMeteorShower-xq6xx
@JoyfulMeteorShower-xq6xx 3 ай бұрын
Sensor problem sa outdoor on nahi hora agar blower motor kharab hogi thabi bhee outdoor work nahi karaga deepbtahoo transfarmar kharab hoga tbee outdoor on nahi hoga
@AdityaSingh-bn6wp
@AdityaSingh-bn6wp 2 ай бұрын
Please solve 🙏🏻 my problem
@vijendraverma799
@vijendraverma799 3 ай бұрын
Mera mitsubishi heavy duty srk18yvs w6 split ac hai. Chalne ke 10-15 minute baad cooling band ho jati hai aur green led light 6 times blink kane lagti hai. Kya reason ho sakta hai.
@narenderkumar-gd7ev
@narenderkumar-gd7ev Жыл бұрын
Ac ko dobara chlane k baad hot mode me chla jata h 4-5 baar reset krne pr cooling dene lag jata jaise hi supply jati h hot air dene lag jata please reply split ac duel inverter h
@syedsyedalvina2214
@syedsyedalvina2214 2 ай бұрын
Sir mera ac Hitachi ka hi duphar me garam hawa phekta hi new liya hi esa kyu 2 tun ka hi kya kami hi abhi 10 din bhi nh hue hi liyewe
@rakeshvarshney4368
@rakeshvarshney4368 2 жыл бұрын
3minute split AC chalne ke bad start hona,Punha start challah kya Karan hai,bataye
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## outdoor unit Ka fan ya motor dusri yaa jugaad Kar ke lagaya ho or uska heat fekne ki design yaa shape alag hojati he tab bhi compressor thodi Der heat hokar trip karta he.
@rawatg3189
@rawatg3189 2 жыл бұрын
Bhai ac thik h outdoor khrab ho gya koe dusra outdoor lga skte h.. Plz bhai reply
@mohdsanu8152
@mohdsanu8152 Жыл бұрын
Hmara Daikin ka ac h ampr shi h or compressor tirp ho rha h 2 gante bd outdoor fan chal rha h lekin compressor on nhi ho rha h
@rmgallabout
@rmgallabout 2 жыл бұрын
Mera ac 1.5 ton hai uska out dore thodider cooling karta hai aur badme turant band hota hai our uska picheka fan aur Indore ka fan bhi slow chalta hai please madat kijiye
@ROYALMONSTER-mf1yu
@ROYALMONSTER-mf1yu Жыл бұрын
Llyod 2 ton contractor wiring E3 eroor code kya reasion ho sakta h
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## indoor unit Ka blower Kisi ne alag design Ka Kiya ho tab bhi cooling thodi Der baad bnd ho jata he.
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## indoor unit me nut jaha se tight hota he Jo hissa spring se lipti pipe yaa fir kahi or Kisi piping se pinch ya pipe dab chuki ho to aap meter guage se pata krne par kanta up and down hota rahega stand by Nahi rahega tab bhi compressor thodi Der me band hojata he
@bachokaislam7283
@bachokaislam7283 2 жыл бұрын
Asslam alikumm sir Mera Kenwood AC h 10.mnt chlta h phir just hwa deny lgta coling khtm ho jati phir 10mnt bad coming start ho jati bht preshan main 1,5 daidh tun AC h Mera 23 hzar bil Aya h es bar plz help me
@bachokaislam7283
@bachokaislam7283 2 жыл бұрын
Jo Msla h bta dein
@prashantjaiswal1374
@prashantjaiswal1374 2 жыл бұрын
Mere ghar me carrier sprit a.c hai wo din me chalte chalte band ho jata p6 likha ke ata hai lekin raat me bade aram se chalta hai esa kyo hota hai
@salmanidrisi3371
@salmanidrisi3371 2 жыл бұрын
Ager outdoor pura sistem sahi hai conteckter dabane par chlta hai chod dene par band ho jata hai kya problem ho sakta hai
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## indoor unit Ka blower motor kharab ho ya jaam ho yaa shaft uski rouse ho chuki ho yaa blower se zyada motor gumti ho tabhi ye dikkat Hoti he coile thandi hokar sensor se compressor trip karwata he
@Desicreator5523
@Desicreator5523 Ай бұрын
Mera 1.5 ton ac h .. hardly 2 min chalta h uske baad garam hwa deta h .. uska kya reason ho skta h
@saifsiddiqui4933
@saifsiddiqui4933 2 жыл бұрын
Mera Ac Raat me sahi chalta din me baat baat trip hota hai, outdoor pe dhup bhi nhi padti fir bhi,aisa to nhi ki voltage ki wajah se ho rha hai raat me voltage achhi aati ho din me nhi is wajah se trip hota ho,212-213 ampere voltage aata hai
@YashveerChahar1
@YashveerChahar1 Жыл бұрын
The current is directly proportional to the voltage and inversely proportional to the resistance. This means that increasing the voltage will cause the current to increase. Ek baar ye b dekh lena bhai 2:28 par aapne bola ki voltage decrease hone par ampere increase hoga 2:28 .
@jatinvats4344
@jatinvats4344 Жыл бұрын
Sir 5mint chlna Ka bad compressor band ho jata h new capater bi dak Ka dik liya liki problem solve ni Hua?????
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## outdoor unit me agar motor ki shaft ghumti he magar outdoor kaa fan Nahi gumta he yaa outdoor ki motor or fan Ka shaft free yaa rouse hota he tab bhi compressor thodi Der heat hokar trip karta he
@kailash4069
@kailash4069 2 жыл бұрын
Sir मेँ आपका app, ac, tech डावनलोड कर रख्खा हैं पर उसमे daikin कैसेट ac के बारे मेँ कोई एरर नहीं हैं 2टन का कैसेट ac है15मिनट चलने के बाद coling बंद हो जती हैं
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## outdoor unite me compressor 5-10 minutes chalne par suction line par return proper aata hoga magar after 5-10 minutes compreeser ke piston ya michenism me kharabi ki wajah se awaaj karke band hota he or sirf fan on rehta he or suction line garam hojati he
@deepakmittal7736
@deepakmittal7736 2 жыл бұрын
Same condition...plz reasion btao
@KahkashanAnsari2000
@KahkashanAnsari2000 2 жыл бұрын
Same problem
@Doctorzafar
@Doctorzafar Жыл бұрын
Our Hitachi 1.5 ton window ac 3 star after 2 or 3 hours it becomes jaam, then we stop and restart after 20 minutes, it works again. But it jaams again after 3 or 4 hours. What is this.
@jugalprince4384
@jugalprince4384 2 ай бұрын
Mera chachi ka split AC hai thodi der cooling Karta hai FIR chhod jata hai kya Karan hai
@sachinpal2043
@sachinpal2043 3 ай бұрын
Aadha ghnta Ac sahi chlta h fer outdoor band ho jata h coil sensor badal dia ac service bhi krw di capacitor bhi badal diye fer bhi same issue h kya kare sir
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## inverter AC me outdoor unit ke sensor Kisi Tarah se kharab ho ya kisine kutar diye ho tab bhi compressor humming leke bnd hota yaa start Nahi ho pata he error dekar.
@cargillfeednalvi4210
@cargillfeednalvi4210 Жыл бұрын
plz sir btye... ac chlte chlte mode lg jata hai .. automatically jiss se cooling nhi hoti fan fan chlta hai plz sir btye kya kre
@RajinderACTech
@RajinderACTech 8 ай бұрын
सर डाइकिन ऐसी है एक चालू करो तो 1 घंटा चलता है उसके बाद ऐसी बंद हो जा रहा अपने आप फिर चालू ही नहीं हो रहा है क्या प्रॉब्लम हो सकता है
@talibabbas2690
@talibabbas2690 2 жыл бұрын
Sir evopretion kise kahete hai
@thakurhimanichauhan8160
@thakurhimanichauhan8160 Жыл бұрын
Ac band hone k baad kitne dar tk room main cooling rahti h
@ChandanDas-dt9cp
@ChandanDas-dt9cp 2 ай бұрын
Ductbal ac ushaka compressor chall leaking cooling nahi hota hai
@RiJWANali777
@RiJWANali777 2 жыл бұрын
Sir problem ko sol krne ke liye koi whatsapp group h kya?
@AdityaSingh-bn6wp
@AdityaSingh-bn6wp 2 ай бұрын
Mera to bilkul cooler nhi ho rha hai,aaj hi servicing karaya hai, aur capacitor bhi change hua jai
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
## inverter AC me mostly Panasonic me 10 minutes chalne ke baad " df" defrost me system deta he jisme pcb regarding issue rehta he agar dusri pcb replacement yaa repair karwani padti he
@toshikazone6394
@toshikazone6394 2 жыл бұрын
K8
@technicalvd7978
@technicalvd7978 Жыл бұрын
1.5 ton ac h 2 min outdoor fan chlega band ho jayega or fir ni chlega cooling bhi ni hoti h kya kiya jaye
@TheParirana
@TheParirana Жыл бұрын
E 1 se bhi aise problem hoti h kyaa
@KT-lk9hz
@KT-lk9hz Жыл бұрын
Sir, carrier ka ac 1hour ekdam sahi chalta hai , uske baad off ho jata hai ,
@PawanKumar-hy3uc
@PawanKumar-hy3uc Ай бұрын
Sir 50 digree pr compresor kyu trip karta hai sab kush thik hai
@user-ub7rm7yx6z
@user-ub7rm7yx6z Жыл бұрын
bhai ak or kami he wo ye he ki kayi war makenik jalwaji me oudur diwar par fit karti sameh dihan na dene par a c kaam nhi karta matlab ye hi ki jase diwar pe oudur lagaya to uski samne ki diwar dur honi chahiye kyunki pass hone se cumpresar war war tirip hoga
@user-ub7rm7yx6z
@user-ub7rm7yx6z Жыл бұрын
Vikas thakur
@ankurjangra3887
@ankurjangra3887 2 ай бұрын
Humara Hitachi 1.5 ton inverter AC h din me tho sahi chalta h raat me thodi der tho cooling deta h uske baad cooling nhi krta kuch bhi kr lo or din me sahi chalta h plz help me 🙏🙏🙏🙏
@chandrashekhargiri7102
@chandrashekhargiri7102 Жыл бұрын
16-6-23 ko technician ne aakar mera voltas 1.5 ton AC ko re install aur service kiya lekin ab cooling thik se nhi ho rahi hai, kya kru
@sristi5183
@sristi5183 Жыл бұрын
Nice
@ACTechpro
@ACTechpro Жыл бұрын
Thankyou
@pushpayadav7674
@pushpayadav7674 3 ай бұрын
Meri ac to new he h bus ek mahina he hua h
@manojrefrigeration728
@manojrefrigeration728 2 жыл бұрын
Sir samsung ka ac hai uska 60 se automatic 120 hota hai candensor bhi saf kiya to bhi pressure badh ta hai Kay problem ho sakta hai
@vaishnavigupta4322
@vaishnavigupta4322 Жыл бұрын
Bhaiya mera new Ac h lyod ka Ac kam nahi kar rha h jese hi cooling start hoti h band ho jata ha apne Aap
@singerkrishnapandit7827
@singerkrishnapandit7827 Ай бұрын
भाई थोड़ा सरल भाषा मे बताया करो ताकि सभी को समझ आ सके, सभी AC के एक्सपर्ट नही हैं। और कैसे चेक करना है वो भी बताओ न। नही तो जब मकैनिक आएगा तो वो अपने हिसाब से बता के बना कर चला जायेगा
@rahulrawat389
@rahulrawat389 2 жыл бұрын
My samsung ac temperature not goes done below 25 c room temperature what will be the issue refill the gas after vaccum 2 times problem not solved
@thahollywoodmovies4114
@thahollywoodmovies4114 2 жыл бұрын
11tr ki r407 gass me h or suction pipe pr ice aa rha h
@shivansvlogtech
@shivansvlogtech 2 жыл бұрын
Voltas window AC h 14 ampeir pe chal Raha hai cooling kam h kya kare
@ejazhotelwala8299
@ejazhotelwala8299 2 жыл бұрын
Piping distance long hone se bhi normal 1 ton AC ke compressor kam Nahi Kar pate.
@anujmalhotra7790
@anujmalhotra7790 3 ай бұрын
1.5ton LA window at hi chalta hi cooling karta hi kuch der ke Bad ex horable sound keep sath Band ho jata hi air tine keep Bad fir so suru hota hi
@jaikumarsukla61
@jaikumarsukla61 Жыл бұрын
Apka bhashan se kuch pta nahi chal raha ap clear btaye ki mera ac chal raha hai lekin cool nahi ho raha hai
@MohitKumar-ti3hb
@MohitKumar-ti3hb 2 жыл бұрын
New ac 1.5, ton Hitachi AC hai chalte chalte cooling chali gai kyak kare input stabLizer par 253 or op 238 hai
@gouravhooda882
@gouravhooda882 2 жыл бұрын
bhai jyada tar ac 45°© m cooling dena bhnd jr dete h ... is mamle m ogenral ac is best
@sandeepbeniwal1995
@sandeepbeniwal1995 2 жыл бұрын
भाई मेरे साथ ऐसा ही हुआ है वोल्टैज खराब है
@gouravhooda882
@gouravhooda882 2 жыл бұрын
@@sandeepbeniwal1995 it's need stable voltage
@MohitKumar-ti3hb
@MohitKumar-ti3hb 2 жыл бұрын
@@sandeepbeniwal1995 hmmm
@puneetjoshi9743
@puneetjoshi9743 2 жыл бұрын
Voltage problem hoti ha Blue Star 1.5 ton ac MA kitna volt ka staplizar lagya
The Joker saves Harley Quinn from drowning!#joker  #shorts
00:34
Untitled Joker
Рет қаралды 56 МЛН
Son ❤️ #shorts by Leisi Show
00:41
Leisi Show
Рет қаралды 10 МЛН
Kind Waiter's Gesture to Homeless Boy #shorts
00:32
I migliori trucchetti di Fabiosa
Рет қаралды 6 МЛН
No empty
00:35
Mamasoboliha
Рет қаралды 12 МЛН
Main reason for ac tripping problem|| Compressor trip problem ||
7:21
ac turns off after 15 minutes | split ac turns off automatically
10:02
The Joker saves Harley Quinn from drowning!#joker  #shorts
00:34
Untitled Joker
Рет қаралды 56 МЛН