Charging R-410A Refrigerant Into An Air Conditioner Using Wireless Probes!

  Рет қаралды 29,719

AC Service Tech LLC

AC Service Tech LLC

Ай бұрын

In this HVAC Training Video, I Show How to Use Wireless Probes to Check the Refrigerant Charge and How to Correctly Charge R-410A Refrigerant into this Running Air Conditioner! Technicians Must be EPA 608 Certified to Handle Regulated Refrigerants! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In The Video:
Fieldpiece Complete Job Link Probe Kit - trutechtools.com/Fieldpiece-C...
Fieldpiece STA2 Thermal Anemometer Hotwire AirFlow Meter trutechtools.com/STA2?aff=8
Hilmor RSWL220 Wireless Refrigerant Scale 220lbs trutechtools.com/hilmor-rswl2...
At Trutechtools.com use code acservicetech for 8% off
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos:
• Charging R-410A into a...
• Charging an R-410A AC ...
• R-410A Charging and Re...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicetech.com/store
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicetech.com/hvac-ca...
Our Newest Articles: www.acservicetech.com/articles
Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
Our Other Resources: www.acservicetech.com/resources
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicetech.com/tools
Our Tool List on Amazon: www.amazon.com/shop/acservice...
Support the Channel by purchasing tools through Tru Tech Tools!
Use this link www.trutechtools.com/?aff=8
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.com/show/74KXLz5...
Apple Podcasts: podcasts.apple.com/us/podcast...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #hvactechs #technician #training #airconditioner #airconditioning #r410a #charge #checkingthecharge #refrigerant #refrigerantcharging
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 90
@user-yn8gv2mp8n
@user-yn8gv2mp8n 8 күн бұрын
Thank for the video, the effort and time you put in make the world a better place to leave in.
@deanmartin1966
@deanmartin1966 Ай бұрын
Excellent video Craig. I do love my fieldpeace probes.
@deanmartin1966
@deanmartin1966 Ай бұрын
I'm sure I've said it before, but thanks for all the great free information you and all the other great teachers provide. Such a wealth of knowledge. I'm 58 and I absolutely hated high school. Until I got into the trades. Then surprisingly I became an "A" student. I seriously love the trades and think its a great alternative to a four year college. My grand daughter is 15 and wants to become a welder. She makes me proud. Once again, thanks. Phil
@paulrmfd
@paulrmfd Ай бұрын
absolutely instructional keep up the good work
@craigmarshall40
@craigmarshall40 9 күн бұрын
Great video thank you for spending the time
@manueldacosta6539
@manueldacosta6539 Ай бұрын
Excellent video as always, thank you.
@jorgemanzano7232
@jorgemanzano7232 Ай бұрын
Well explained! Thank you very much 😊
@electrolatif
@electrolatif Ай бұрын
The best aircon video in KZfaq ❤
@snwsk8
@snwsk8 Ай бұрын
Great tips as always, thank you
@AndyHoltOutdoorUniversity
@AndyHoltOutdoorUniversity Ай бұрын
Nice job, Craig!
@TheWathever516
@TheWathever516 Ай бұрын
Great video!
@zahedaminullah6934
@zahedaminullah6934 Ай бұрын
Great video man!
@kennethlobo4420
@kennethlobo4420 Ай бұрын
Well explained ❤
@gingerstrand6153
@gingerstrand6153 Ай бұрын
Great video, thank you!!
@repairitdontwreckit4257
@repairitdontwreckit4257 Ай бұрын
Thanks. Nice job.
@yannkitson116
@yannkitson116 Ай бұрын
Great video, I have Testo probes and a slightly different app but it is all the same in the end :)
@APHVAC0913
@APHVAC0913 Ай бұрын
Great video 👌🏽
@pongobongo2295
@pongobongo2295 Ай бұрын
Use Appion charging tees. This is my go to charge set up. Also, get a third probe and map to outdoor air temp.
@butlerstouchHVAC
@butlerstouchHVAC Ай бұрын
great vid
@mohdrifi1930
@mohdrifi1930 Ай бұрын
Excellent! You need to do this method to ac split unit also! Appreciate your effort teacher! ❤️❤️❤️❤️
@cryptkeyper
@cryptkeyper Ай бұрын
This is a ac split unit
@jericosha2842
@jericosha2842 Ай бұрын
This doesn't work on mini split ductless if that's what you mean
@edwardlouie
@edwardlouie Ай бұрын
I like using core depressors so I don't need to spin on/off quickly.
@kastenusa
@kastenusa Ай бұрын
Can you please make a video on where to connect probs on package unit correctly. Thank you!
@cryptkeyper
@cryptkeyper Ай бұрын
I second this
@povoljan13
@povoljan13 Ай бұрын
The charging hose has air when you hooked it up to the tee. The small space after the shutoff valve is dead air space. Needs a better setup maybe?
@vonboldler5219
@vonboldler5219 Ай бұрын
Hi mike!
@pana5075
@pana5075 Ай бұрын
Espero este video en español
@lorunner1213
@lorunner1213 Ай бұрын
Craig. Does the outdoor Dry bulb temp matter if being read from the sunny side of the condenser vs the shady side?
@justinhughes452
@justinhughes452 Ай бұрын
What was the recommended amount of refrigerant on the name plate? How much was in system at the start and what was the total amount at the rnd of this demonstration?
@monstaro19
@monstaro19 29 күн бұрын
We need a way to use this in cars its 106 in Florida
@arthurrabon9349
@arthurrabon9349 28 күн бұрын
multi zone split unit question. if you have 3 zones and 1 zone is having troubles meeting set temp. how does system respond.
@NickNameNemo
@NickNameNemo 28 күн бұрын
If system has leakage (r410a) and still remains some amount of refrigerant, let’s say 70-80% of total, should I recover all refrigerant from system and charge it with new or just add needed amount?
@globecomputers1
@globecomputers1 Ай бұрын
Great video! Like always! Question can you provide a link for those AC test caps? I need to buy a set.
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs Ай бұрын
Just take two spare caps and drill a hole in them.
@JuanJuarez-en5xn
@JuanJuarez-en5xn Ай бұрын
Where can I buy those T’s that go on your probes do you have a link to them ?
@user-ry6ii8ql2p
@user-ry6ii8ql2p 21 күн бұрын
? What is the link for the brass tees to purchase sir. Thank You.
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs Ай бұрын
Although I’m sure sponsored, nice to see someone make a video that didn’t say you had to use MQ and True Flow or you’re a hack.
@x-got2bkidiny-justlikeabov787
@x-got2bkidiny-justlikeabov787 Күн бұрын
Awesome explanation but … the label on the unit says indoor TXV with 10 deg F sub cooling. You say it has a fixed orifice so you’re using the superheat method - am I a missing something here?
@acservicetechchannel
@acservicetechchannel Күн бұрын
Yes so the outdoor unit will always tell you the subcooling if a txv is used. However, as you can see through that plexiglass at the indoor unit, there is a piston there and not a txv. Single stage outdoor units can be installed with any combination of indoor units and metering device, thanks! To learn more check out our books at acservicetech.com !
@var8492
@var8492 23 күн бұрын
What if my liquid pressures are at 390 and suction 174 with a 11 t/s !??
@tomaszpoznanski7584
@tomaszpoznanski7584 Ай бұрын
Iam a contractor and would like to do a course/training for a/c contractor. Can you recommend any in NY/NJ/PA area? Any schols?
@pitaeata8493
@pitaeata8493 Ай бұрын
need tips and tricks to determine if a system has a piston or txv. Sometimes on UNCASED coils it is impossible to remove the front of the field made cover to get a look.
@sir.cannabis1173
@sir.cannabis1173 Ай бұрын
I'm thinking one could tell by how fast the numbers move. Craig mentioned it might take 15 minutes for pressures to equalize with a fixed.
@mackenziegray2090
@mackenziegray2090 Ай бұрын
If you see a threaded union outside the case, chances are you got a piston.
@turnedearthdesign8678
@turnedearthdesign8678 Ай бұрын
Also check the chart on the condenser. It usually (but not always) tells you what the pressure of one of the lines should be which should match up to the metering device used
@mikev.1034
@mikev.1034 Ай бұрын
👍👍
@JuanJuarez-en5xn
@JuanJuarez-en5xn Ай бұрын
Can you make a video on RTU’S?
@mackenziegray2090
@mackenziegray2090 Ай бұрын
It's the samething. What part confuses you?
@edwardlouie
@edwardlouie Ай бұрын
This method doesn't always work with inverter variable speed equipment that change the superheat target based on various logics.
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs Ай бұрын
Inverters usually don’t have fixed orifices.
@wpl11972
@wpl11972 Ай бұрын
I just use my valve core removal tool as my tee.
@emidiolopez1409
@emidiolopez1409 Ай бұрын
So you remove the schrader valve to do SH or SC? Or what kind of removal tool do you use that has a press tool built in? Because the Appion that I use don’t have the press tool so I can’t take any risk of losing 5+ pounds of refrigerant by removing the schraders lol
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs Ай бұрын
@@emidiolopez1409if your loosing 5 lbs with a core removal tool you’re using it wrong. How much refrigerant are you going to lose I’d the schrader doesn’t seal?
@emidiolopez1409
@emidiolopez1409 Ай бұрын
@@HVAC_Tips_Tricks_Calcs Ive never said I’m losing 5 pounds by using the schrader removal tool. I said that’s just stupid if you have to remove the schrader valves every time you have to check the pressures on an AC, NO way I’m taking risks in losing factory refrigerant if something doesn’t goes bad with the removal tool.
@davidlopan6649
@davidlopan6649 Ай бұрын
I can see myself pulling the pressure probes off the T and accidentally letting out all the refrigerant. lol definately would put a valve core on that for me.
@lorunner1213
@lorunner1213 Ай бұрын
I use apion tee’s. They are low loss with schraders on both male ends of the tee. So doesn’t matter if you pull just the probe off. Or the tee with the probe.
@davidlopan6649
@davidlopan6649 Ай бұрын
@@lorunner1213 Yeah I love appion tools. Just purchased their recovery machine. I didn't get probes yet probably next year.
@JuanJuarez-en5xn
@JuanJuarez-en5xn Ай бұрын
Where did you bought those T’s ?
@lorunner1213
@lorunner1213 Ай бұрын
@@JuanJuarez-en5xnJohnstone Supply
@Ahmed198831
@Ahmed198831 Ай бұрын
🙏🙏🙏🙏
@jimwhite9483
@jimwhite9483 Ай бұрын
How hard would it be for Fieldpiece to add a wireless input for ODDB in the app or on the SMAN 380V?
@turnedearthdesign8678
@turnedearthdesign8678 Ай бұрын
You can link one of their psychrometer probes to the outdoor dry bulb
@martinguzman4323
@martinguzman4323 15 күн бұрын
👍👍👍👍👍👍👍👍👍👍👍👍👍
@mtbbiker6401
@mtbbiker6401 Ай бұрын
I don't understand how taking a low pressure (vapor line) reading at the condenser translates to the pressure in the evaporator. Why is it not industry standard to take low pressure (vapor line) reading at the evaporator?
@8799crosby
@8799crosby 19 күн бұрын
There is no ports at the evap .
@mtbbiker6401
@mtbbiker6401 19 күн бұрын
@@8799crosby So we are measuring total super heat temp using thermometer near the service port at the condenser (outdoor unit for heat pump) and measuring the pressure at the same service port to measure the temperature at the evaporator (indoor unit for heat pump). We measure pressure to convert to temperature. If we are measuring the temp and the pressure at the same spot, why don't the temp readings match? I'm trying to understand the physics behind this. Does it have to do due with saturation temp, sensible heat, latent heat?
@EricJohnson-dr5wb
@EricJohnson-dr5wb 17 күн бұрын
@@mtbbiker6401good question. The pressure on the low side is essentially the same in the evaporator as it is at the low side service port. The vast majority of the cooling is due to the liquid to vapor phase change in the evaporator coil. The additional heating of the 100% vapor is the superheat. You want there to be some superheat to prevent liquid refrigerant from entering and damaging the compressor.
@957543
@957543 3 күн бұрын
Because you want to be able to be in one spot
@hazendismukesjr.8319
@hazendismukesjr.8319 Ай бұрын
😂why didn't you use a charging orifice
@Bigdawg_74
@Bigdawg_74 Ай бұрын
sadly most techs will hook up and immediately say it's good or needs refrigerant because companies are so focused on getting techs in and out as fast as possible. Most expect a complete diagnosis to be complete in 30 min max preferably less.
@TheRealDegen100
@TheRealDegen100 Ай бұрын
Preferably way less but every call is different. Only calls that really take time is determination of why a part failed.
@kevinpearce3281
@kevinpearce3281 Ай бұрын
Why can’t you put the r410a into the liquid side if it’s coming in as a liquid
@davidgochenour7072
@davidgochenour7072 Ай бұрын
It would push refrigerant into your bottle
@camilo8cheryl
@camilo8cheryl Ай бұрын
High pressure
@WhatIsYourCard
@WhatIsYourCard Ай бұрын
The liquid side is at a high pressure while the system is running. Connecting the refrigerant jug to the suction line, which is a lower pressure, will suck the refrigerant into the system.
@wyattdekay7763
@wyattdekay7763 Ай бұрын
Usually to much pressure
@boongoon92
@boongoon92 Ай бұрын
It's leaving as a liquid
The Refrigeration Cycle of an Air Conditioner, 4 Main Parts!
1:00
AC Service Tech LLC
Рет қаралды 61 М.
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,4 МЛН
Викторина от МАМЫ 🆘 | WICSUR #shorts
00:58
Бискас
Рет қаралды 5 МЛН
MISS CIRCLE STUDENTS BULLY ME!
00:12
Andreas Eskander
Рет қаралды 20 МЛН
Best KFC Homemade For My Son #cooking #shorts
00:58
BANKII
Рет қаралды 73 МЛН
Digital HVAC Gauges or Wireless Probes | Which should YOU buy??
17:00
Explaining Superheat and Subcooling to Your Apprentice!
14:14
AC Service Tech LLC
Рет қаралды 597 М.
"Flammable" Refrigerant Facts for Residential HVAC
1:02:01
HVAC School
Рет қаралды 68 М.
10 Reasons Why A Mini Split Flare May Be Leaking Refrigerant!
18:15
AC Service Tech LLC
Рет қаралды 721 М.
Liquid Line Restriction on AC Unit Explained! Found Bad TXV!
13:35
AC Service Tech LLC
Рет қаралды 385 М.
MINI SPLIT Parts Explained! Understand What They Do!
19:31
AC Service Tech LLC
Рет қаралды 629 М.
Refrigerant Recovery Training! Tips, Problems, Best Practices, Setup!
24:37
AC Service Tech LLC
Рет қаралды 124 М.
3 PROVEN Methods To Getting Colder Air From HVAC Vents.
10:45
The DIY HVAC Guy
Рет қаралды 482 М.
How To Check Superheat & Subcooling On An HVAC System
16:03
The DIY HVAC Guy
Рет қаралды 104 М.
Testing if an HVACR Compressor is Shorted to Ground, Open, or Overload Tripped!
11:06
Викторина от МАМЫ 🆘 | WICSUR #shorts
00:58
Бискас
Рет қаралды 5 МЛН