2x4 falling over to the word Subscribe got me. Subscribed.
@givetanks2 ай бұрын
My plan is working 😁 glad to have ya!
@elvinsworld118 күн бұрын
Nice
@givetanks7 күн бұрын
Thank you!
@SuperSonfish4 ай бұрын
This is the best tutorial I have ever seen so creative and entertaining and was easy to follow good job and thank you bro
@givetanks4 ай бұрын
Thank you! It's great to hear that as you never know how your filming is gonna turn out
@henry20tv1110 ай бұрын
Thanks for sharing
@givetanks10 ай бұрын
Thank you for commenting!
@k9higgins7 күн бұрын
Great build man! What’s your thoughts on keeping the uprights inside the stand a few mm off of the floor to limit contact and prevent any levelling issues? I see a few builds done that way
@givetanks7 күн бұрын
As long as the main stand structure is supported I don't see and issue
@IndoorEcosystem9 ай бұрын
This is one solid stand! I had a few run ins with "weird angles and not being square" a couple of runs 😅 Good call on the electrical switch safety as well! Saved me once when a heater exploded!
@givetanks9 ай бұрын
Thanks man! Yeah I tend to overengineer things by a lot
@IndoorEcosystem9 ай бұрын
@@givetanks it's well worth saving the potential heartache on something like this! Peace of mind!
@givetanks9 ай бұрын
@@IndoorEcosystem True!
@Soulsack9 ай бұрын
@@givetanks This is not your first rodeo, judging by the video. ;)
@givetanks9 ай бұрын
@@Soulsack Nope I keep the bull in the back yard
@gabbernautchris1980Ай бұрын
Excellent 👏👏👏
@givetanksАй бұрын
Thank you!
@Mrmike7106 ай бұрын
Hey looking great so far..Im getting ready to start on mine.I was wondering were those screws the self drilling ones where no pre drilling is required,and what size.I hear that you have to use the #8-2 1/2" but can the #9-2 1/2" be used as well.This by far is the most solid and step by step tutorial for a good stand build bro.
@givetanks6 ай бұрын
The screws are just deck screws and I think #9 should be fine as well, pre drilling may or may not be needed - just depends if your wood is too dry and splits
@ChristopherLecky2 ай бұрын
how does one use influence to create the absence of influence?
@givetanks2 ай бұрын
Tell a knock knock joke?
@ChristopherLecky2 ай бұрын
orientation...and expansion! decipher why people feel they have an influence to being with.....
@Mrmike710Ай бұрын
What size screws did you use for the plywood top,and have you considered finish nails?
@givetanksАй бұрын
They might work but I like to over engineer things and I use 1" for the top
@Mrmike710Ай бұрын
#8-1"
@Soulsack9 ай бұрын
Hey man were nice build video, Keep them coming. sturdy but seams a bit overkill, better safe than sorry i guess ;)
@givetanks9 ай бұрын
I always overkill because I don't know if I'm going to use for 10 gallons or 100. I like to keep my options open
@johnrobertd7483 ай бұрын
But how to figure out how much weight it will hold? 200 gallons is a lot different from 50 gallons
@givetanks3 ай бұрын
one 2 x 4 has an axial load of roughly 1000lbs so if you used 2 x 4's in the middle and did two support struts in the middle unlike the one I did you could park your car on it. FYI 200 gallon is about 1600lbs. But I'm not an engineer so get professional advice if your worried about it - you could also have angled supports and make it bullet proof.
@Fshgrl.or.plntgrl2 ай бұрын
How much weight do you think this can hold?
@givetanks2 ай бұрын
Should be able to hold a lot - the exact weight I'm not sure.
@harrytaylor89792 ай бұрын
I disagree with the GFI outlet. Yes it will help from killing you but if it trips and your not home for hours upon hours your fish will die.
@givetanks2 ай бұрын
A battery back up will help with that, like a mp10 or 40
@haroldgreen14254 ай бұрын
Retired electrician and life long fish keeper. I will never put an aquarium on a gfci. Why? Because a simple power surge may trip it and kill hundreds if not thousands of dollars of fish or other livestock.
@givetanks4 ай бұрын
This is true, but I've never had this issue and I have been shocked before,, so I will always put them on a gfci. Plus everything is on a battery back up so not really an issue. Plus, I can replace a tank - not me or anyone else if they get shocked badly.
@lastditch7277 күн бұрын
@@givetanksI've never once thought about my tank shocking me. New fear unlocked. Thanks? Lol
@givetanks7 күн бұрын
@@lastditch727 the risk is low but it has happened but your breaker would most likely trip too but a GFCI could also help prevent a piece of equipment for shorting out and keep arcing to prevent a house fire