Bench testing an Agilent E3620A and E3610A power supply.

  Рет қаралды 375

Craig Petersen

Craig Petersen

19 күн бұрын

In this video I test two power supplies I purchased from eBay.

Пікірлер: 5
@sebastian_harnisch
@sebastian_harnisch 17 күн бұрын
It's been a long time since I used one of those power supplies, probably more than a decade. I like the low noise (acoustically and electrically), but I've never understood why HP built versions without a programmable current limit (I should rather say: I wouldn't want to do without it). I've seen a video (actually, I think more than one) about these power supplies where capacitors leaked badly, destroying traces and causing leakage currents that affect operation. Although I can't remember whether these were HP or Agilent branded, I would certainly inspect/measure and potentially replace the caps if I wanted to keep these supplies. I was really surprised to see these problems, because I rarely had any bad caps in my old HP gear (6060B, 5334B, 33120A etc.). One notable exception is the 53131A (in my case Agilent) with its SMPS - and it's a type of equipment that is common to see many hours of operation.
@CraigPetersen12f36b
@CraigPetersen12f36b 16 күн бұрын
With all the HP, Agilent, Tektronix and Fluke gear that I have, I have only run into a capacitor issue twice. An HP 3437A and an HP 5328A that had a power supply over volt failure. While I was taking the 5328A apart, I discovered that the main power supply filter caps were only now just barely starting to show signs of leakage around the terminals. Prior to that the 5328A was working just fine. That's pretty good run for something that was built in the late 70's to early 80's. I have yet to run into an issue where there was leakage that resulted in trace or some other board damage. Most of the equipment that I have had been serviced in the last 5 to 10 years, however I do inspect the filter caps and check the power supply voltages on the units that have missing, broken or old anti-tamper service stickers. Thanks for watching!
@sebastian_harnisch
@sebastian_harnisch 16 күн бұрын
@@CraigPetersen12f36b one exception are the RIFA caps. These have almost always a cracked case and usually have to be replaced.
@imken2392
@imken2392 17 күн бұрын
If you're interested, I've got an extra HP 8920A RF Communications Test Set I would let go inexpensively. It has errors in the RF_Diags tests but does boot up and has all menus working.. Amtronix Instruments Calibrated and upgraded the one I have on my bench. They will also repair the 8920A. Chris S knows who I am if you want more info or to play with it before you buy. Everson Wa.
@CraigPetersen12f36b
@CraigPetersen12f36b 16 күн бұрын
Thanks for the offer. I originally wanted to find a HP 8920A or Motorola R2600 series communications analyzer, but they were either priced higher than what I was willing to pay for, had seen rough service or had a number of faults. So I settled on purchasing discrete instruments instead of buying an all-in-one solution. I may re-visit the issue down the road, but so far I'm satisfied with the current setup. Thanks for watching!
Every Component of a Switch Mode Power Supply Explained
23:10
ElectrArc240
Рет қаралды 152 М.
Happy 4th of July 😂
00:12
Alyssa's Ways
Рет қаралды 63 МЛН
Я нашел кто меня пранкует!
00:51
Аришнев
Рет қаралды 5 МЛН
ОСКАР vs БАДАБУМЧИК БОЙ!  УВЕЗЛИ на СКОРОЙ!
13:45
Бадабумчик
Рет қаралды 6 МЛН
Tektronix 571 Curve Tracer
16:20
Craig Petersen
Рет қаралды 2,1 М.
ROCKET that LITERALLY BURNS WATER as FUEL
19:00
Integza
Рет қаралды 1,2 МЛН
HP 5359A Time Synthesizer
7:39
Craig Petersen
Рет қаралды 880
The Rise and Fall of the Cray Supercomputer
32:29
Asianometry
Рет қаралды 376 М.
How 3 Phase Transformers Work - why we need them
24:24
The Engineering Mindset
Рет қаралды 456 М.
Quick overview of the HP 436A Power Meter.
13:28
Craig Petersen
Рет қаралды 1,1 М.
Linear DC Power Supplies - Designing & Building Custom DC Power Supplies
1:12:39
Happy 4th of July 😂
00:12
Alyssa's Ways
Рет қаралды 63 МЛН