What's a bayonet fuse !?

  Рет қаралды 18,304

Bobsdecline - Lineman blogger

Bobsdecline - Lineman blogger

2 ай бұрын

The fuse link is on the high voltage side. It's very important to use a hot stick when removing them and remember, this will only isolate the secondary bushings! Don't forget that pressure relief valve!
Big thanks to dragonwear for the arc rated gear! 🔥🐲
#dragonwear #bobsdecline #lineman

Пікірлер: 75
@Bobsdecline
@Bobsdecline 2 ай бұрын
You may have noticed my rusty wrench :(. Tills keep getting water in em! Might have a Milwaukee solution for that very soon... 🤫
@glitter_fart
@glitter_fart 2 ай бұрын
i almost spit out my drink when you touched that connector inside the panel
@dacharyzoo
@dacharyzoo 2 ай бұрын
the knipex plier wrenches are amazing, worth every penny. I can't go back to adjustable wrenches, so much fumbling.
@jamess1787
@jamess1787 2 ай бұрын
You're a mind reader!
@TexasStormChaser
@TexasStormChaser 2 ай бұрын
Time to get a stainless
@SteveRead-fx4rg
@SteveRead-fx4rg 2 ай бұрын
I'm not sure how many regular electricians (and by regular I mean electricians that deal with 480 volts 3 phase or less in industrial, commercial, or residential settings) watch your videos but as a whole other leg of the trade it is always interesting to watch and learn how the other half of the trade does things. Thanks for spreading the knowledge.
@andycopeland7051
@andycopeland7051 2 ай бұрын
Thats me. Mostly commercial and what I would call light industrial for 10 years but I'm fascinated by this.
@rhamph
@rhamph 2 ай бұрын
It'd be worth repeating in the video that this transformer isn't installed, that's why you can demonstrate using your hands. Cheers!
@RustyorBroken
@RustyorBroken 2 ай бұрын
The gas springs for the cover are mounted upside down. They have a small amount of oil in them that lubes the rod bushing and seal. For that reason they should be mounted rod side down whenever possible. When they are installed rod side up the rod seal will eventually run dry and fail prematurely.
@PessimismAndLoathing-bn7ss
@PessimismAndLoathing-bn7ss 2 ай бұрын
These videos are fascinating. Hell, my lights wouldn't be on without linemen. Cool stuff!
@linehandibew6205
@linehandibew6205 2 ай бұрын
In Puerto Rico they had overhead porcelain bayonet fuses. The handle was porcelain and you had to push it in like a sword, by hand by the way. There was no way to hot stick them. The base literally looked like the handle from a sword. All 4kv system by the way. So yeah that was fun in your hooks having to send them in by hand
@Bobsdecline
@Bobsdecline 2 ай бұрын
That sounds horrible! Lol
@linehandibew6205
@linehandibew6205 2 ай бұрын
@@Bobsdecline you can google bayonet fused cutouts search images and you’ll see what I’m talking about
@Bobsdecline
@Bobsdecline 2 ай бұрын
I just did, crazy! Never seen one of those
@linehandibew6205
@linehandibew6205 2 ай бұрын
@@Bobsdecline I believe Detroit still has them on their system
@bigbee5673
@bigbee5673 2 ай бұрын
we installed and livened up a 3 phase pad mount (brand new) and had a bad fuse/bad voltage. Shows how important the voltage check really is.
@martf1061
@martf1061 2 ай бұрын
1:44 The "drip pad" is a good idea.👍 I bet it took a lot of oil spills and a lot of time to finally get the engineers to agree on adding this simple feature ..
@johnclyne6350
@johnclyne6350 2 ай бұрын
Aaron that’s brand new on a wood palette. Nice video! Thank you Miguel! Everyone deserves Miguel as a second set of hands on every job. Your right! That wrench is rusty! I like that lid lifting on the front top of the transformer. Makes pulling those fuses easier! Ours don’t do that. They go with the low bid here. When we first started getting these bayoneted style fuses in 3 phase pad mounts, they arrived without fuses. Did you get to see “My Story in the IBEW Newsletter for the month of May 2024?
@Bobsdecline
@Bobsdecline 2 ай бұрын
The lid certainly is nice! I did see the article! Very well done and proud of ya John! I'm not sure if you saw my last e-mail
@johnclyne6350
@johnclyne6350 2 ай бұрын
@@Bobsdecline No, I had not? I'll have to look in my spam folder then? I hope it's good news from you? You have been in my thoughts with everything on your plate.
@AlanTheBeast100
@AlanTheBeast100 2 ай бұрын
Nice vid - as time goes on the components seem to get simpler, better and easier to manipulate.
@inothome
@inothome 2 ай бұрын
Ever have to change the other fuse inside too? There's the bayonet and then a second fuse, PRCLF, in series for current limiting that is NOT as easy to get to. I see it listed on the dataplate on this transformer and shown as CL on the diagram. I have seen them looking in to a tank, but luckily never had to change one out.
@Bobsdecline
@Bobsdecline 2 ай бұрын
We'll just swap the entire unit in that case
@inothome
@inothome 2 ай бұрын
@@Bobsdecline I hear that!
@SFoley990
@SFoley990 2 ай бұрын
Good instruction Bob.
@SocialistDistancing
@SocialistDistancing 2 ай бұрын
Always educational!
@jeffreykornspan9053
@jeffreykornspan9053 2 ай бұрын
Thanks for the video Aaron. Stay safe!
@cjvillarreal217
@cjvillarreal217 2 ай бұрын
I saw a video today on Facebook that showed these fuses but it was vague. Thank you for doing a video on this!!
@Mdwells2944
@Mdwells2944 2 ай бұрын
Very interesting videos!! I work for an energy company in KY/PA but am in the desktop support department so it is interesting to see what the lineman are out there keeping the power on.
@thomasrobinson8336
@thomasrobinson8336 2 ай бұрын
Great Training video
@KoonKustoms
@KoonKustoms 2 ай бұрын
Most people wouldn’t know you can open a secondary side with the bayonet fuses on a radial feed circuit. If you had a bad URG instead of taking out a large amount of customers
@KoonKustoms
@KoonKustoms 2 ай бұрын
You can isolate a single customer instead of everyone else on that circuit
@frederickbowman4494
@frederickbowman4494 2 ай бұрын
GREAT VIDEO!!!!!!!!!!!!!
@ronwade2206
@ronwade2206 2 ай бұрын
I love it, big Al. 😅
@andycopeland7051
@andycopeland7051 2 ай бұрын
Golly 100A at 7200volt that's some power
@jovetj
@jovetj 2 ай бұрын
720000 watts
@SodiumInduction-hv
@SodiumInduction-hv 2 ай бұрын
Interesting
@rayraap3905
@rayraap3905 Ай бұрын
Aaron just started watching your channel and love it, but why the name Bobsdecline?
@fuzzyfireman1
@fuzzyfireman1 2 ай бұрын
Does the fuse itself fill with oil? When they blow, a lot of gas is released. In oil, not so much.
@yurizhivago4848
@yurizhivago4848 2 ай бұрын
I worked in a hospital with 575 3 phase ( 600 volt ) transformers on our own property. Apparently they needed maintenance and we had 2 electricians on staff. Never got to see what they did. Do you service those and maybe you can make a video? Keep up the good work.
@jovetj
@jovetj 2 ай бұрын
❤Miguel !
@josiahhorner6705
@josiahhorner6705 2 ай бұрын
Why did you change the fuse if it wasn't bad? Thanks for the videos their educational.
@jeanrichard3933
@jeanrichard3933 2 ай бұрын
Frig miguel is handsome…
@heatherkohlwey8379
@heatherkohlwey8379 2 ай бұрын
Do those make a loud noise then they go? My husband and I were sitting outside watching a storm roll in a few days ago. The gust front hit and the fuse on the pole at the corner of our yard blew. We ducked inside rather quickly. Thanks for the interesting video. Please stay safe, and God bless.
@JackieBright
@JackieBright 2 ай бұрын
I believe some fuses have explosive charges in them to ensure they open fully without arcing, someone may correct me if I'm wrong
@inothome
@inothome 2 ай бұрын
@@JackieBright They don't have an explosive charge, but the fuse links that go in the cut-out "doors" (jacks, tube, fuse holder) are an expulsion type fuses and designed to blow out the arc down the tube by design. And yeah, they can be loud when the blow and what 99% of the people call hearing a transformer blow is really just the fuse blowing. When a bayonet type inside a pad mount blows, I don't think you'd hear much.
@rupe53
@rupe53 2 ай бұрын
@@inothome watched an episode of How It's Made on Discovery channel one night and the manufacturing of fuses was the feature. They explained that some fuses do have an explosive charge built in. Perhaps Aaron can clarify that part in a future video.
@inothome
@inothome 2 ай бұрын
@@rupe53 I work in substations with the same fuses. Bayonets or fuse links do not have explosives in them. They are called expulsion fuses though. Since they extinguish the arc by forcing the arc down a tube aka expulsion and do sound like an explosion. But no explosives at all in them. If they did, there would be warnings, all sorts of regulations and training to go along with it. You wouldn't have 500 of them sitting in a bin on a truck or out in the open in a warehouse. There are some fuses or breakers in HVDC for EV cars that do have a small pyrotechnic charge in them though.
@unwired1281
@unwired1281 2 ай бұрын
👍👍👊‼️
@tomsetlock7380
@tomsetlock7380 2 ай бұрын
😎
@6AK5W-JAN
@6AK5W-JAN 2 ай бұрын
Why are those mushrooming tabs on one side only? Both ends of the fuse are secured by threaded plugs, surely if mushrooming tabs serve some purpose on one end, they would need to do the same at the other end too.
@PLEBEJones
@PLEBEJones 2 ай бұрын
Can you show us how to prepare a Burd transformer ?
@jacobchuning167
@jacobchuning167 2 ай бұрын
Be careful when installing and removing the fuse holder. That oil can get very hot.
@Know_Your_Enemy
@Know_Your_Enemy 2 ай бұрын
Ohhhhh… Bayonet Fuse?!??? Never heard of it..But.. It sounds Interesting!!!!
@martf1061
@martf1061 2 ай бұрын
Is the reason for those fuses to be on the low voltage side ( secondary ) , because the high voltage side protection ( cutout doors on the pole ) is not "sensitive" enough, to correctly protect the transformer, in case of overloading? Or, are the cutout doors on pole are there to protect the wires, and not the transformer? I'm an electrician, and 99% of times, we only fuse the primary, and use appropriate wire size gauge accordingly.
@jaredtippets6255
@jaredtippets6255 2 ай бұрын
We call them cigarette fuses 👍
@jovetj
@jovetj 2 ай бұрын
_Don't_ smoke 'em if you got 'em.
@J-W775
@J-W775 2 ай бұрын
ol white chalk board chalk keep moisture away from tools in tool box
@raymondseeger4832
@raymondseeger4832 2 ай бұрын
What would cause these to blow? Too much draw on the secondary/customer side, or some other fault?
@macdadstromboli2762
@macdadstromboli2762 2 ай бұрын
I've seen it only a few times. It might be up to the company you work for. Would you not wear a type of face shield when working on those? 🤔
@slednut894
@slednut894 2 ай бұрын
I'd like to see whats inside the oil tank once drained.
@martf1061
@martf1061 2 ай бұрын
Probably the same as a dry type transformer. But yeah, that would be interesting to see.
@mark111943
@mark111943 2 ай бұрын
Quick question, so I assume those fuses can be removed under load as the oil quenches the arc?
@Bobsdecline
@Bobsdecline 2 ай бұрын
Yessir!
@mark111943
@mark111943 2 ай бұрын
@@Bobsdecline thank you for the reply and for all your videos!
@martf1061
@martf1061 2 ай бұрын
Maybe a stupid question, but as an electrician, I'm curious about the reason you would pullout one of these fuses under load? Usually, we only remove fuses because they blown.
@jackhandyy
@jackhandyy 2 ай бұрын
Dude, losing weight, congrats!!!!
@keything8487
@keything8487 2 ай бұрын
obligatory comment ........ here
@duzaliteraf7373
@duzaliteraf7373 2 ай бұрын
1 second ago No views No comments No likes I'm first
@VictorHernandez-hv8qh
@VictorHernandez-hv8qh 2 ай бұрын
Hey Aaron, do you have instagram or facebook?
@Bobsdecline
@Bobsdecline 2 ай бұрын
Yessir! I try my best to keep up with Dm's on both platforms
Service disconnect for demolition by order of fire marshal!
16:26
Bobsdecline - Lineman blogger
Рет қаралды 214 М.
Solo Recovery Of HUGE Trailer Abandoned In The Desert!
30:13
Casey LaDelle
Рет қаралды 1,1 МЛН
50 YouTubers Fight For $1,000,000
41:27
MrBeast
Рет қаралды 199 МЛН
Summer shower by Secret Vlog
00:17
Secret Vlog
Рет қаралды 9 МЛН
Эффект Карбонаро и нестандартная коробка
01:00
История одного вокалиста
Рет қаралды 9 МЛН
A clash of kindness and indifference #shorts
00:17
Fabiosa Best Lifehacks
Рет қаралды 125 МЛН
10 Common Mistakes DIYers Make In Circuit Breaker Boxes
13:55
LRN2DIY
Рет қаралды 2,3 МЛН
Linework w/ some cows for a ground hand! 🤷‍♂️
20:49
Bobsdecline - Lineman blogger
Рет қаралды 24 М.
HYDRAULIC PRESS VS ARMOR, USA AND RUSSIA
10:16
Crazy Hydraulic Press
Рет қаралды 182 М.
Where Does Grounded Electricity Actually Go?
19:36
Practical Engineering
Рет қаралды 5 МЛН
Going Somewhere
10:40
Mountain States Line Constructors
Рет қаралды 7 М.
How do power poles catch fire?
11:05
Bobsdecline - Lineman blogger
Рет қаралды 30 М.
Messy pole = Rats nest
15:55
Bobsdecline - Lineman blogger
Рет қаралды 299 М.
Power outage response - Virtual ride along!
15:07
Bobsdecline - Lineman blogger
Рет қаралды 40 М.
If I touch this tower, I die
43:19
Geerling Engineering
Рет қаралды 1,1 МЛН
Hazardous tension on Powerline - working solo
21:21
Bobsdecline - Lineman blogger
Рет қаралды 66 М.
50 YouTubers Fight For $1,000,000
41:27
MrBeast
Рет қаралды 199 МЛН