No video

BS&W Basic Sediment and Water ASTM D4007 | Yazenkom

  Рет қаралды 10,266

Yazenkom

Yazenkom

Күн бұрын

BS&W Basic Sediment and Water
in this video you will learn how to perform BSW test using ASTM standard method D-4007 using oil centrifugal method .
don’t forget to subscribe to receive new videos.
Like and share to support the channel.. Thanks.
#BSW #BS&W #Basic_sediment_water #ASTM #D-4007
#Yazenkom #Yazen_kom #Analysis #Practical #laboratory #experiments #Oil #Gas #understanding #Solid #oil_&_gas #calculation #calculating #lab #Chemistry

Пікірлер: 30
@namalpushpersri2186
@namalpushpersri2186 Жыл бұрын
You missed very important step. You must do Toluene saturation at 60 Celsius with water before the test within 24 hrs is better. Just follow toluene saturation procedure as per ASTM D4007. Anyway, good short explanation.
@yazenkom1505
@yazenkom1505 Жыл бұрын
Thank you for your note
@RohitYadav-cz6kn
@RohitYadav-cz6kn 2 жыл бұрын
Really very useful vedio for everyone...very good plate form after vedio i am so happy... Again again thank you so much
@yazenkom1505
@yazenkom1505 2 жыл бұрын
Appreciate your positive words Rohit , The main purpose of this platform is to share my experience as Chemist & hopefully someone benefits from those videos 🌹
@houdaghedeiramar7667
@houdaghedeiramar7667 2 жыл бұрын
useful vedio thanks
@yazenkom1505
@yazenkom1505 2 жыл бұрын
Thank you Houda 🌹
@ibrahimmahmoud311
@ibrahimmahmoud311 2 жыл бұрын
Nice , just If the samples is different in density should be equal balance by addition drop of solvent to avoid the danger of tubes breaking.
@yousufwahibi9952
@yousufwahibi9952 2 жыл бұрын
ما شاء الله عليك بارك الله فيك أخي
@yazenkom1505
@yazenkom1505 2 жыл бұрын
شكرا لك أخي يوسف 🌹
@mariammady
@mariammady 10 ай бұрын
Thanks for this great video 🥰
@yazenkom1505
@yazenkom1505 9 ай бұрын
Really glad you find it useful 🌹🌹
@yasserallam2776
@yasserallam2776 Ай бұрын
السلام عليكم بارك الله فيك اخي يزن و نفع بك من فضلك متى نستخدم المعادلة RCF = r(rpm/265)^2 و متى نستخدم المعادلة الاخرى RCF = r(rpm/1335)^2
@mohanadabid9049
@mohanadabid9049 Жыл бұрын
GOOD Job man
@yazenkom1505
@yazenkom1505 Жыл бұрын
Thanks Mohand
@hishamalmabsali9502
@hishamalmabsali9502 2 жыл бұрын
Excellent bro
@yazenkom1505
@yazenkom1505 2 жыл бұрын
Thanks Hisham 🌹
@SaaaMRaaaN
@SaaaMRaaaN 2 жыл бұрын
Excellent work 💪🏻 brother keep it up.. all the best
@yazenkom1505
@yazenkom1505 2 жыл бұрын
Thanks bro 🌹
@RohitYadav-cz6kn
@RohitYadav-cz6kn 2 жыл бұрын
Thanks a lot sir i appreciate
@yazenkom1505
@yazenkom1505 2 жыл бұрын
You are welcome 🌹
@dalemiller5271
@dalemiller5271 Жыл бұрын
If ASTM D-4007 is the laboratory method for determining sediment and water in crude oil and "impurities are measured as BASIC sediment and water results"; then what other S&W results are there? For instance, is there an ADVANCE sediment and water? Thank you for the excellent video.
@yazenkom1505
@yazenkom1505 Жыл бұрын
To my knowledge the term "basic" refers just to the fundamental nature of the test and its importance in evaluating the quality of crude oil.. the amount of non hydrocarbons contaminants in crude oil samples.. ASTM D4007 speaking about sum of both impurities S&W , were you can get sediment in crude by extraction ASTM method D473 , or water in crude by distillation method ASTM method D4006 Hopefully this help
@bobotubeful
@bobotubeful 4 ай бұрын
Sorry guys, is this the same as ASTM D96. I m confused. though, this is really useful guide. Love it
@yazenkom1505
@yazenkom1505 4 ай бұрын
FIRST Sorry for the late RESPONSE, and thank you for bringing this out. Yes D96 is the "field procedure" , but D4007 is " laboratory procedure" , , The Lab procedure D4007 is more accurate and you can find this statment mentioned in the scops of D96
@bobotubeful
@bobotubeful 4 ай бұрын
@@yazenkom1505 thx a lot
@mohammedabdulkhaleq6981
@mohammedabdulkhaleq6981 2 жыл бұрын
why do we use toluene solvent in this process? can we use only crude oil sample with demulsifer?
@yazenkom1505
@yazenkom1505 2 жыл бұрын
Salam Mohammed The solvent is added to reduce the viscosity and dissolve Paraffin and Asphaletene that can cause inaccurate result. You can use different solvent like shellsol instead of toluene Not recommended to do that without solvent , maybe it might work for some samples but you never know the characteristics of your sample , my advise is better to follow avilable ASTM D4007 standart testing method
@ibrahimmahmoud311
@ibrahimmahmoud311 2 жыл бұрын
like dissolved like
@khalidalghamdi8148
@khalidalghamdi8148 2 жыл бұрын
السلام عليكم اخوي يزن كيف طريقة التواصل معك ؟
@yazenkom1505
@yazenkom1505 2 жыл бұрын
مرحبا أخي خالد ربي يسعدك .. أرسلت لك دعوة في منصة لينكدن ، هناك سأخبرك عن كيفية التواصل .شكرا 🌹
Density ,Relative density and API gravity | Yazenkom
2:58
Yazenkom
Рет қаралды 6 М.
How City Water Purification Works: Drinking and Wastewater
12:26
Animagraffs
Рет қаралды 733 М.
Вы чего бл….🤣🤣🙏🏽🙏🏽🙏🏽
00:18
Gli occhiali da sole non mi hanno coperto! 😎
00:13
Senza Limiti
Рет қаралды 18 МЛН
VIHA DV 10 PLUS VENTILATOR ORIENTATION
3:35
Nursing Station
Рет қаралды 1
The End of Haber Bosch
13:51
Reactions
Рет қаралды 178 М.
Salt in Crude Analyser | ASTM D3230 | IP 265
3:44
Stanhope-Seta
Рет қаралды 11 М.
THE STRONGEST ACID IN THE WORLD Fluoroantimonic acid
26:36
ChemicalForce
Рет қаралды 7 МЛН
Extracting Pure Silicon Dioxide from Dirt
13:36
Amateur Chemistry
Рет қаралды 58 М.
Conventional vs Unconventional Oil and Gas
5:12
EnergyTrainingResLLC
Рет қаралды 31 М.
Driver Tips - Hauling Crude Oil
11:07
Andy Lash
Рет қаралды 85 М.
Damascus Steel From Stick Welding Electrodes
14:15
Alec Steele
Рет қаралды 662 М.
How do Demulsifier additives break oil/water emulsions?
7:05
Lubrication Explained
Рет қаралды 16 М.