THE MECHANICAL EFFECTS
OF SHORT-CIRCUIT CURRENTS
IN OPEN AIR SUBSTATIONS

Пікірлер: 24
@christopherleubner6633
@christopherleubner6633 Ай бұрын
Its pretty crazy seeing the high current conductors in industrial arc furnaces. The conducting cables sway and dance from the powerful magnetic fields. 😮
@TheScreamingFrog916
@TheScreamingFrog916 Ай бұрын
Love the spacey synthesizer background music. Like Vangelis or Tangerine Dream. Great choice by the original film makers. I salute you 👍
@PaulFisher
@PaulFisher 9 күн бұрын
I saw this comment before the music kicked in and thought that you were being too generous and that it was going to be just ok production music. But no-it really does go hard.
@philhealey4443
@philhealey4443 Ай бұрын
Transient tubular displacement and clashing of the sub-conductors under high root mean square current conditions, combined with kinetic impulse effects on the droppers was indeed of significant concern.
@molkhal
@molkhal 3 жыл бұрын
I love the video quality. Brings back memories of mpeg coding
@flaplaya
@flaplaya Жыл бұрын
I always had a hunch galloping high tension lines was from extreme currents opposing opposite magnetic fields in other phases and or magnetic Flux of earth. Awesome presentation
@someonesomewhere1240
@someonesomewhere1240 6 ай бұрын
Most of that is from wind and maybe weight changes from ice suddenly falling off. It's rare, but still designed for, for an actual short to occur. The forces from normal load current are generally negligible.
@Look_What_You_Did
@Look_What_You_Did Ай бұрын
You would be wrong...
@gustavgnoettgen
@gustavgnoettgen Ай бұрын
​@@Look_What_You_Did They got an explanation four months ago...
@onradioactivewaves
@onradioactivewaves Ай бұрын
There was some very large lines I would drive by sometimes, I'm guessing around 350kV. Light drizzle raindrops would pop and cause the lines to really start resonating, quite interesting to watch.
@Muck-qy2oo
@Muck-qy2oo 5 жыл бұрын
Incredible forces and incredible currents! And all of them must be kept below a contact voltage of 25 V.
@PhilMacVee
@PhilMacVee 17 күн бұрын
Sight of this must influence every protection engineer to ensure that the systems operate correctly and disconnect faults as rapidly as the system requires. It is a given that the switchgear operates correctly under fault conditions. In the UK NG require fault clearance in 80/100/120/120ms for 400/275/132/66kV. A significant amount of energy can be spent in 80ms at 400kv typically at 50kA with ratings of [i think] 35000MVA.
@sasikarthicka5312
@sasikarthicka5312 4 жыл бұрын
Good video on understanding short circuit force!
@varunlover
@varunlover 2 жыл бұрын
Ultimate video , never saw such type . Hope u create more
@qpwodkgh2010
@qpwodkgh2010 Ай бұрын
Wow! Good thing I saw this. Not knowing this kept me up most nights.
@rafa_br34
@rafa_br34 Ай бұрын
It's quite insane that all of that is just caused by electrons bumping into metal atoms.
@alishafi1
@alishafi1 2 жыл бұрын
can you upload next video please
@prakashmakhijani2196
@prakashmakhijani2196 Жыл бұрын
I have one basic doubt, which I would like you to clarify. As per BIS, the transmission towers are designed based on working tension, wind force and self weight of conductors and insulators. But there is no mention of SCF in design of transmission towers. It is only applicable to the design of structures within AIS. I would like to know the exact reason, why SCF is not applicable in transmission towers. Also, for the incoming gantry tower, what forces need to be considered for structure design.
@someonesomewhere1240
@someonesomewhere1240 6 ай бұрын
I *think* that the wider spacing of conductors on lines would generally result in much lower short-circuit forces than in switchyards where minimum clearance is necessary to maximise density.
@Dannyboy31415
@Dannyboy31415 24 күн бұрын
​​This is true, but the increased length of conductor between towers means the short cct force goes up again. There's another factor to consider however and that's the component that fails from short cct force. The weakest point in AIS is the post insulators which the conductor is sitting on. These are weaker than the steel structures beneath and are what snaps. On a transmission line, string insulators are used instead of post insulators, which can cope with a higher force as they are under tension only. They don't experience cantilever forces. I've not done much design on transmission towers so I'm not sure what's standard for them. Just saying that the assembly is different.
@am74343
@am74343 Ай бұрын
Wow! These designs don't seem very robust or safe! Doesn't seem like a good idea to have electrical cables randomly swinging around!
@bussi7859
@bussi7859 Ай бұрын
Talkalotcrapper
@Look_What_You_Did
@Look_What_You_Did Ай бұрын
Speak american.
@nos9784
@nos9784 Ай бұрын
Uhm... 11:06 Did you notice how all the work whs done by europeans, maroccans, and canadians?
Repairing Underground Power Cables Is Nearly Impossible
13:34
Practical Engineering
Рет қаралды 4 МЛН
Busbar sizing
9:27
stephen brooks
Рет қаралды 124 М.
狼来了的故事你们听过吗?#天使 #小丑 #超人不会飞
00:42
超人不会飞
Рет қаралды 57 МЛН
Normal vs Smokers !! 😱😱😱
00:12
Tibo InShape
Рет қаралды 119 МЛН
Ну Лилит))) прода в онк: завидные котики
00:51
Where Does Grounded Electricity Actually Go?
19:36
Practical Engineering
Рет қаралды 4,9 МЛН
138 kV High Voltage Substation Walk
33:44
SpeedFreakLS1
Рет қаралды 26 М.
Centaur Short Circuit Test - KEMA Arnhem 2008
3:32
Ellis Patents Ltd.
Рет қаралды 86 М.
Kortsluitproef krachtwerking kabelblokken KEMA
3:59
Wim Inrush
Рет қаралды 21 М.
High-Voltage Test for Insulators
3:15
Wacker Chemie
Рет қаралды 221 М.
Short Circuits - Cable Ties vs  Cable Cleats
0:47
Ellis Patents Ltd.
Рет қаралды 40 М.
Going Somewhere
10:40
Mountain States Line Constructors
Рет қаралды 4,3 М.
Radio Frequency Burns From A Long Wire Antenna Supported By A Kite
3:42
Grants Pass TV Repair
Рет қаралды 250 М.
Open Neutral
11:41
Dave Gordon
Рет қаралды 814 М.
狼来了的故事你们听过吗?#天使 #小丑 #超人不会飞
00:42
超人不会飞
Рет қаралды 57 МЛН