To connect a Siemens S7-1200 PLC to a C# application using the S7.NET library, you can follow these steps. S7.NET is a popular library for communicating with Siemens S7 PLCs from a C# application.
Note: Ensure that you have the necessary hardware and software components installed and configured, including the Siemens S7-1200 PLC and a working Ethernet connection.
Install S7.NET Library:
You need to install the S7.NET library in your C# project. You can do this using NuGet Package Manager in Visual Studio. Search for "S7.NET" and install the package.
Create a C# Project:
Start a new C# project or open an existing one where you want to communicate with the Siemens S7-1200 PLC.
Import Required Namespace:
In your C# code, import the necessary namespace for S7.NET:
csharp
Copy code
using S7.Net;
Initialize and Configure the PLC Connection:
You need to create an instance of the Plc class and configure the connection to your Siemens S7-1200 PLC. Replace IPAddress and Rack and Slot with your PLC's actual IP address and hardware configuration:
csharp
Copy code
Plc plc = new Plc(CpuType.S71200, "your_plc_ip_address", rack: 0, slot: 2);
Open the Connection:
Open the connection to the PLC:
csharp
Copy code
plc.Open();
Read Data from PLC:
You can read data from PLC using the Read method. For example, to read a single byte from the memory area DB1 at address 2, you can do:
csharp
Copy code
byte[] data = plc.Read("DB1.DBX2.0");
Write Data to PLC:
You can write data to the PLC using the Write method. For example, to write a value of 42 to a DB1 integer at address 4, you can do:
csharp
Copy code
plc.Write("DB1.DBW4", (short)42);
Close the Connection:
After you have finished communicating with the PLC, it's important to close the connection:
csharp
Copy code
plc.Close();
Handle Exceptions:
Make sure to handle exceptions appropriately, as network or communication issues can occur. You may want to use try-catch blocks to handle exceptions gracefully.
Build and Run:
Build your C# project and run it. Ensure that your PLC is connected to the network and reachable from your computer.
Remember to replace placeholders like "your_plc_ip_address" with the actual IP address and adapt the code to your specific use case and PLC setup. Additionally, consult the S7.NET library documentation for more advanced features and functionality.

Пікірлер: 14
@fired_developer
@fired_developer 9 ай бұрын
great!
@plcfocus.solution
@plcfocus.solution 9 ай бұрын
oki sir
@sare61
@sare61 13 күн бұрын
that tutotrial is posible with plcsim without plc real?
@rafaelm.deoliveira3457
@rafaelm.deoliveira3457 8 ай бұрын
Please can you tell me if the library uses the OPC UA protocol for reading and writing?
@plcfocus.solution
@plcfocus.solution 8 ай бұрын
you can using KEPSERVEREX OPC Sir
@eng_nasurhasan7619
@eng_nasurhasan7619 3 ай бұрын
Please what type of plc you use?
@plcfocus.solution
@plcfocus.solution 2 ай бұрын
S71200 CPU1212C AC DC RLY
@sonerarslan1110
@sonerarslan1110 24 күн бұрын
Hello, First of all, it was a really useful video. Thank you for the information. But I get an error like this in a similar program I made. (system.exception: 'the size of the class is less than 1 byte and therefore cannot be read') There are exactly 21 bools in the class I created. Frankly, I could not find much content regarding this problem. I would be glad if you could help me. Thank you.
@plcfocus.solution
@plcfocus.solution 24 күн бұрын
please try to add 1 spare tag as integer at the last of that DB, don's put all only bool type. need to have byte or integer or real tag type in that DB.
@sonerarslan1110
@sonerarslan1110 24 күн бұрын
@@plcfocus.solution Hello, I wrote 30 lines mixed with bytes and ints, but it still says that the minimum readable class must be 1 byte. example public static byte _op1 {get; set;} public static short _op2 {get; set;} thank you for your response.
@yusufyaldz231
@yusufyaldz231 8 ай бұрын
var PLC_DB = 2; plc.ReadClass(TagList, PLC_DB); I'm getting this info error. I want to show you the error I got. System.Exception: 'The size of the class is less than 1 byte and therefore cannot be read' I need a solution, can you help me? (I AM USING S71500 PLC)
@plcfocus.solution
@plcfocus.solution 8 ай бұрын
please show me the DB in plc and the class "tagList" Sir (in picture) via whatsapp or gmail
@yusufyaldz231
@yusufyaldz231 5 ай бұрын
@@plcfocus.solution i have solved this error i will write a comment on how I solved this error in my free time thank you for everything a great educational video.
@sonerarslan1110
@sonerarslan1110 24 күн бұрын
Merhaba sorunu çözebildin mi?
Gym belt !! 😂😂  @kauermtt
00:10
Tibo InShape
Рет қаралды 16 МЛН
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 62 МЛН
🤔Какой Орган самый длинный ? #shorts
00:42
OPC UA Communication  Between Siemens S7-1500 And SCADA Ignition
15:24
INDUSTRIAL AUTOMATION AFICIONADO --- LOUIS WYN
Рет қаралды 85
Connect to Siemens S7 plc with C# and S7.Net
28:57
Mesta Automation
Рет қаралды 154 М.
COM13a. [1/5]Connecting a Siemens PLC(S7-1200/S7-1500) to an SQL Database [SQL Section]
31:43
Electrical Automation Hands-On
Рет қаралды 35 М.
TIA Portal & C# communication
17:42
Abdullah KARAKAYA
Рет қаралды 15 М.
Siemens S7-1500 Communicate With Ignition By  PLCSIM  Advance And KEPserverEX -- Part One
22:35
INDUSTRIAL AUTOMATION AFICIONADO --- LOUIS WYN
Рет қаралды 75
Java Is Better Than Rust
42:14
ThePrimeTime
Рет қаралды 149 М.
S7-1200 Data logging Siemens PLC
18:08
Ali Al-Mukhtar
Рет қаралды 206 М.
C# and Mitsubishi FX lesson 1   Read data from PLC to C#
9:16