No video

Can I have Span 7.6 meter (25ft) between Two Columns - How to Keep span 7.6 meter b/w 2 Columns?

  Рет қаралды 219,398

Civil Engineers

Civil Engineers

4 жыл бұрын

#CivilEngineers
Spacing b/w RCC COlumn
7 meter span for column
How to keep span of RCC COlumn

Пікірлер: 181
@accsltd6978
@accsltd6978 3 жыл бұрын
easy explanations yet solid knowledge ! 🙋👌
@lansanah.kamara5299
@lansanah.kamara5299 2 жыл бұрын
Thank you for your excellent explanation. I always enjoy your calculations and explanation.
@tomusuaquo
@tomusuaquo Жыл бұрын
I have always enjoyed your insightful explanations. This one was really refreshing. Benefiting a lot from it; so please keep it going.
@gowthamram7852
@gowthamram7852 4 жыл бұрын
Only one doubt... Beam width is bigger than column width... Will it be safe to carry load... 700 x 500 - Beam size... 400 x 400 - Column Size... 500 sits on 400... Will column show heavy buckling when 50mm on either sides of the beam projected outwards...
@risingmoon7008
@risingmoon7008 4 жыл бұрын
Please urdu main lecture diya krein g
@houseplaninkannada
@houseplaninkannada 4 жыл бұрын
Right
@tamuzhs3095
@tamuzhs3095 2 жыл бұрын
Thank you sir more doubts are cleared thank you very much sir more useful
@buddha2845
@buddha2845 2 жыл бұрын
Very good question
@pcrsekarsekar6540
@pcrsekarsekar6540 2 жыл бұрын
For 400 x400 column beam size can be restricted to 700 x300 or not
@prabhatkumardangi7354
@prabhatkumardangi7354 2 жыл бұрын
How do you rest the 560 mm width beam on the 400 X 400 mm column which you have calculated?
@markchen8312
@markchen8312 2 жыл бұрын
He's bullshit!!!
@Utkarshkr.
@Utkarshkr. Жыл бұрын
I came here to comment this.. XD
@indrajeetbondar9251
@indrajeetbondar9251 10 ай бұрын
Absolutely
@kenbomkamsiriba1587
@kenbomkamsiriba1587 5 ай бұрын
Indeed
@kenbomkamsiriba1587
@kenbomkamsiriba1587 5 ай бұрын
Means column size also must be changed
@rohitjamadar3706
@rohitjamadar3706 4 жыл бұрын
Plz reduce the light 💡 on the board
@Engrferdz525
@Engrferdz525 3 жыл бұрын
Your very good Engr.. Keep it up and more videos.
@prmodrwt
@prmodrwt 4 жыл бұрын
For G+2 building, 7.5 x 7.5 m grid system , central columns will have minimum 2200 km reaction.(Live load 3kn,DL 1.5, seismic zone iv) So min.size column 600x600 mm Beam 450x450 will be more than enough....
@kaqntxpcrlgwmwpwios
@kaqntxpcrlgwmwpwios 3 жыл бұрын
this guys make tutorial only for G+1 ...watch his previous videos..dumbb
@fortuner123
@fortuner123 3 жыл бұрын
Just work through one example as per the regulation. You can talk about variations after. You keep dotting around from this to that which makes it confusing.
@sooner5484
@sooner5484 2 жыл бұрын
Thank you. Great video. Cheers.
@ajitsinghmalik4703
@ajitsinghmalik4703 2 жыл бұрын
Gud knowledge sir
@silentwatcher1455
@silentwatcher1455 4 жыл бұрын
Interesting discussion. The loading consideration on that beam design was not clear.
@VAIBHAVSPAL
@VAIBHAVSPAL 4 жыл бұрын
Very Nice Explaination Sir
@C_Pratical
@C_Pratical 4 жыл бұрын
How the beam of size 560x760 is land on the size of column of 400X400 .
@ahteshamilyas3016
@ahteshamilyas3016 3 жыл бұрын
Exactly
@akeemfrancis6794
@akeemfrancis6794 4 жыл бұрын
Thanks for your work sir. What would be the foundation column and plinth beam design for garage with a master suite above using these beams as floor beams?
@rameshg8439
@rameshg8439 Жыл бұрын
Thank you sir 👌
@tharangarukmal2803
@tharangarukmal2803 4 жыл бұрын
there is not mentioned about concrete grade
@danaal-barzanjy6730
@danaal-barzanjy6730 4 жыл бұрын
i designed a hall for confrance . distance bitween the tow coulum is 12m . and the beam bitween them is 78cm . is this safe
@md.al-amin2793
@md.al-amin2793 3 жыл бұрын
good
@jasminj.5657
@jasminj.5657 3 жыл бұрын
On existing Third floor terrace floor Column size has 450mm x 230mm Total 8 column Total three galas Each gala has, columm to column span is 12'8" x 18' ( note : this dimensions are not measured from the centre to center of the column ) All 10 beams has width 6" and depth 24" We are willing to increase one more slab i.e. fourth floor slab this would be our last slab With same all dimensions as above third floor have except beams. Beams would have width 9" and depth 12" on fourth floor So would it work out ????? Can this transfer load properly Waiting for your response
@osmanyussuf7069
@osmanyussuf7069 2 жыл бұрын
Excellent thanks
@kalpeshpatil1250
@kalpeshpatil1250 4 жыл бұрын
It doesn't mention any load , if the load case will consider what Will be changes in design after considering the load case ???
@mccletus5686
@mccletus5686 3 жыл бұрын
Nice done
@shijojohn8288
@shijojohn8288 3 жыл бұрын
Good content...keep going 👍
@mian6275
@mian6275 4 жыл бұрын
25 ft is not a Critical case.. It's just simple to design .. try 35' at least
@user-fk4hq8yw9u
@user-fk4hq8yw9u 3 жыл бұрын
35 feet ???
@booksourexistence2153
@booksourexistence2153 4 жыл бұрын
Thanks a lot... Sirji
@ganeshkumarkannaiah3395
@ganeshkumarkannaiah3395 4 жыл бұрын
25ft span animation video or site video easy to understand thank you sir
@umeshthapamagar2503
@umeshthapamagar2503 2 жыл бұрын
Good sir
@alancominguez5972
@alancominguez5972 3 жыл бұрын
thank you
@buddikakumara1
@buddikakumara1 3 жыл бұрын
Thanks a lot...
@kingengrad6176
@kingengrad6176 4 жыл бұрын
sir, how to calculate the size of reinforcement bar for this case?
@shanmugambr9633
@shanmugambr9633 3 жыл бұрын
Width of beam 560 and width of column 400 how?
@srilaxmikumari5209
@srilaxmikumari5209 3 жыл бұрын
explain it with feet also ,it would be easy to understand
@FrancisKrakani-cj3ox
@FrancisKrakani-cj3ox 10 ай бұрын
Please the reflection of the light could not allowed us to see proper on baord
@mohanakrishnan1150
@mohanakrishnan1150 2 жыл бұрын
Yes this is the correct way 👍
@kondeanderson9380
@kondeanderson9380 3 жыл бұрын
In my case I have a span of 9m between rc columns which size of beam should I use
@pankajnegi2336
@pankajnegi2336 2 жыл бұрын
Kindly put design of 9.40mtr Spain for slab beam as well as how to fing steel in beam col and slab kindly explain with clearity I mean 4% area of col we how much steel we can used in col.
@jnyanendrakumarjena4354
@jnyanendrakumarjena4354 4 жыл бұрын
Thanks.
@amitbhatt006
@amitbhatt006 4 жыл бұрын
My column is 9/14 with 16mm bar 3 layer can I take 25ft span beam on this column and pls suggest about steal bar mm for beam
@imtayaz786
@imtayaz786 2 жыл бұрын
How to reduce size of column on g+1 when slab has been cast
@Aasifkhan11770
@Aasifkhan11770 4 жыл бұрын
Thanks sir Plz clear about size of column how can we deside the size of column in normal structure
@majidshah3078
@majidshah3078 4 жыл бұрын
Dear kindly tell the height of ceiling, because trends ate are shifting , what if i want the ceiling height to be 25 feet, can the same formulae be used there as well ? thanks
@fittamizha925
@fittamizha925 4 жыл бұрын
How 560mm wide beam rest on 400mm wide column???😕
@AA-pf6ed
@AA-pf6ed 2 жыл бұрын
What details of reinforcement beam in this example
@nabumdavid
@nabumdavid 4 жыл бұрын
Can I provide a column distance of 6mtr for a column size of 250x300mm and also what should be it's beam size and its RCC details. Suggest pls.
@Roadunknown2025
@Roadunknown2025 Жыл бұрын
What size bars+amount use in column? What size bars+amount use in beam? Can the width(400) of beam be the same size as column(400x400)
@sibbuansari1668
@sibbuansari1668 3 жыл бұрын
Thankx u sir
@nazmulkarim6530
@nazmulkarim6530 3 жыл бұрын
Can i take the diatance Between to column 22 ft with 10*12 inches size?
@engineercharles3479
@engineercharles3479 Ай бұрын
What will be the size of column for a beam span of 10m
@md.arifurrahman3809
@md.arifurrahman3809 3 жыл бұрын
Sir, please tell us the formula according to the change of column length.
@foodmates1994
@foodmates1994 3 жыл бұрын
Sir can i take 19 feet span with column size 9/15 with16mm 6 bars rectangler shape it is safe or not plz reply only single floor.
@hugovivas1265
@hugovivas1265 2 жыл бұрын
That formula is for wood beams???
@govindanchelliah8450
@govindanchelliah8450 2 жыл бұрын
Please explain from footing to top roofing ,
@zabighouri2563
@zabighouri2563 4 жыл бұрын
I can't find formula in IS 13920 code
@arsl4256
@arsl4256 Жыл бұрын
Sir plz tell us how we can know which size of bar use in beam or column and also formula for it to calculate the size of bar for different kind of spans
@hmingthanmawiachhakchhuakh5254
@hmingthanmawiachhakchhuakh5254 3 жыл бұрын
what will be tha slab design for lets say L= 25 ft and B= 20 ft... the area is too large will the slab bar hold it or we need support beam
@JayJay-wv1vx
@JayJay-wv1vx Жыл бұрын
My friend you didn't explain properly how you got 400* 400 for column?
@duxerick7653
@duxerick7653 2 жыл бұрын
I didn't understand well can you please just start from the beginning or with the formula?
@mahaboobsubhani6758
@mahaboobsubhani6758 2 жыл бұрын
How u chosen reinforcement as 20 mm......exactly
@NaeeMKhanProduction
@NaeeMKhanProduction 4 жыл бұрын
best bro
@carloaprecio6270
@carloaprecio6270 4 жыл бұрын
hi and thanks for sharing your thoughts, nonetheless, are those sizes indicated in your video applied for 2-3 storeys high structure?
@AK_1947.....
@AK_1947..... 6 ай бұрын
Can i use 10 inch width & 18 inch depth of a beam for a 24 ft gap b/w 2 columns ?
@khhasib9232
@khhasib9232 3 ай бұрын
How is it possible..Beam's breadth is Larger than column Breadth??
@roshnichingakham2183
@roshnichingakham2183 Жыл бұрын
Plz explain for G+1 storey 18ft column and grade beam
@m.v.b1
@m.v.b1 4 жыл бұрын
Can I take 30 foot span for commercial building
@JULOOS_OF_INDIA
@JULOOS_OF_INDIA 4 жыл бұрын
Sir area of steel bhi bataye if structural load na pta ho
@felekedewuye2466
@felekedewuye2466 4 жыл бұрын
Thank u !!!!!!
@isaacamoah-baiden5380
@isaacamoah-baiden5380 2 жыл бұрын
Does the beam depth include the thickness of floor slab...which is 6inches or 150mm.?
@obareziobinnag-wood9112
@obareziobinnag-wood9112 2 жыл бұрын
Please, in G+1, what about using 4x16mm bar, in a col. size of 225x225mm between a span of 6200mm and dept of beam 450mm with bar 5x16mm. Can it carry?
@mohammadzian320
@mohammadzian320 3 жыл бұрын
Boss how about if the size is 6meter between 2 column what is the of column and beam?
@rishabh.sharma2424
@rishabh.sharma2424 2 жыл бұрын
Jai shree Ram 🙏🏻
@md.rafiqulislamrafiq700
@md.rafiqulislamrafiq700 4 жыл бұрын
Can I use 18' clear span column to column?
@onlinebusiness4736
@onlinebusiness4736 Жыл бұрын
Sir please make a house plan for 20×46
@prmodrwt
@prmodrwt 4 жыл бұрын
560x750 beam size 400x400 column size. Hahhhhhh Building will fail due to heavy beam, weak column. KZfaq University
@imtayaz786
@imtayaz786 3 жыл бұрын
Yes I too notice this he said wrng
@bestofsupar693
@bestofsupar693 6 ай бұрын
How much steel bar
@Iftikhar825
@Iftikhar825 3 жыл бұрын
Hello Sir hope your are good and enjoying your life. My question is that can we make col 6x12 inches. Because concrete block width is 6 inches.
@antereatiira1175
@antereatiira1175 Жыл бұрын
hollow sir if the building length 31m width 8m, what types of footing we use and how depth is the footing, and what standard column span?
@AmarKumar-pf4vv
@AmarKumar-pf4vv 3 жыл бұрын
Plzz explain how in a column of 300x 300mm ...we can fixed 400x400mm beam as explained by u sir.
@myk-izhargroupicpl3749
@myk-izhargroupicpl3749 3 жыл бұрын
Assalamualaikum, Sir, thanks for guide line for columns and beam sizes in accordance with the IS 131920 code. Could you please make a video thoroughly, I mean A to Z in a professional way. Suppose, we know the bearing capacity from Geo Tech report and how we can design the building with load of 250 Psf, 200 Psf, 150Psf like that. Although your videos are very helpful but short.
@mohamedabu8754
@mohamedabu8754 2 жыл бұрын
which one i take 760 x 560 OR 400 x 400
@lawrenceloua7325
@lawrenceloua7325 4 жыл бұрын
Can I have 9.76 Column by 32 ft
@aamirsheikh8306
@aamirsheikh8306 4 жыл бұрын
How come the dimension of column could be less than the dimension of beam ain't we suppose to provide strong column weak beam
@zakrians1
@zakrians1 2 жыл бұрын
Are you providing the desig services... I need structure designing of my house.
@momohturay820
@momohturay820 2 жыл бұрын
What should be the depth and width between two column of 25 feet
@louismeoto2126
@louismeoto2126 2 жыл бұрын
Good day sir.please must the column be square.
@sanjaybamne6800
@sanjaybamne6800 4 жыл бұрын
Where is the diagonal tension is maximum in a reinforced concrete beam?
@aakifamurtaza1514
@aakifamurtaza1514 3 жыл бұрын
In this size of column and beam what bars size should be use
@marksmith2723
@marksmith2723 2 жыл бұрын
Sir, after a foundation of a G+1 story has been cast and it's discovered that footings are needed. How do you Add the footings.
@royalrose1987
@royalrose1987 4 жыл бұрын
How to provide hidden beam between two RCc columns of 7 mts
@jong6478
@jong6478 2 жыл бұрын
sir,in this topic,if the size of rcc column is 9x9 inches how many steel bars of 12mm in one column? thank you.
@abdifatahmohamed2604
@abdifatahmohamed2604 4 жыл бұрын
What is the depth of foundation for 4 storey building?
@ayaan5633
@ayaan5633 3 жыл бұрын
This depend on the geological conditions. Under normal circumstances, 1.5 metre depth, 4 X 4 length and breadth is enough.
@mohammedmohiuddin4246
@mohammedmohiuddin4246 3 жыл бұрын
Size of Column is not clear , How to derive and calculate the size of column , in this lecture only size of beam is explained . Also pls explain how to calculate the size of column and size of Bars to be used.
@youngindia9046
@youngindia9046 4 жыл бұрын
IS1392????
@ronyrocker50
@ronyrocker50 4 жыл бұрын
Sir please make a video for column and footing size for a 3storied home.
@vi683a
@vi683a 2 жыл бұрын
Im confused your column is 400 x 400 but your beam is 560 x 760?
@DINESHMaharjan-pe8mt
@DINESHMaharjan-pe8mt 3 жыл бұрын
Width of beam is bigger than column size. Is it possible?
@babuneelam1
@babuneelam1 3 жыл бұрын
Sir How you arrived the column size as 400×400 and steel as dia 20
@AA-pf6ed
@AA-pf6ed 2 жыл бұрын
السلام عليكم We have a mosque whose dimensions are 8 * 6 m. What are the dimensions of the columns and beams? Im from Iraq
@kokkantiseenaiah3851
@kokkantiseenaiah3851 3 жыл бұрын
20×55 senter colam requires
@youngindia9046
@youngindia9046 4 жыл бұрын
Is it size of slab beam or plinth beam ????? In reference of colm
Size of Beam , Size of Column and Spacing between Two Column
13:01
Civil Engineers
Рет қаралды 366 М.
Doing This Instead Of Studying.. 😳
00:12
Jojo Sim
Рет қаралды 32 МЛН
SCHOOLBOY. Последняя часть🤓
00:15
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 11 МЛН
How to Find Depth of Foundation for House? - Minimum Depth of Foundation
14:07
Maximum distance between two columns | Column size and steel details for G, G+1, G+2, G+3 | column
5:21
For 19ft Span - Size of Footing , Column and Beam Reinforcement Details
12:33
✅ Column Beam Slab Structure in a big span 8M- Rcc Structure
15:20
NHÀ XANH VIỆT NAM
Рет қаралды 86 М.
Understanding Buckling
14:49
The Efficient Engineer
Рет қаралды 832 М.
Basic Rules for Lapping length in Column - Lap length in RCC Column
13:34
10 Basic Rules of Column Design -  Don't Forget Basic Rules of RCC Column
13:09
8 Meter Span of Beam and Column reinforcement Details
8:08
Civil Engineers
Рет қаралды 13 М.
What is a Response Spectrum Analysis? and How to use it in Seismic Design of Structures?
12:59
Dr Nafie - Structural Engineering
Рет қаралды 106 М.
Structural Shapes Ranked and Reviewed - Which one Wins?
15:34
The Engineering Hub
Рет қаралды 684 М.
Doing This Instead Of Studying.. 😳
00:12
Jojo Sim
Рет қаралды 32 МЛН