CCTV Interference solved. (Ground Loop Isolator)

  Рет қаралды 20,899

CCTVSystemsUK (@CCTVSystemsUK)

CCTVSystemsUK (@CCTVSystemsUK)

3 жыл бұрын

Hikvision CCTV Interference Solved. (Ground Loop Isolator) (CCTV Fuzzy Picture) (CCTV Lines in Screen)

Пікірлер: 37
@NeerajLalu
@NeerajLalu Ай бұрын
Excellent explantion absolutle the best explanation on this subject
@kayboy6217
@kayboy6217 9 ай бұрын
Am watching from Nigeria,you perfectly gave a kindergarten explanation,I mean you did a smooth, understanding explanation,a good instructor that really want his student to succeed I love this,thank you
@Kbp976
@Kbp976 3 жыл бұрын
Someone finally who knows ground loop
@phiiz3r
@phiiz3r 2 ай бұрын
Can you claify why its better to have the isolator at the DVR end. Wouldn't having it at the camea end reuce the potential for the interference to be picked up by the camera?
@itashamhussain7265
@itashamhussain7265 2 жыл бұрын
This is an excellent video and crystal clear explanation. I have been trying to figure out where my horizontal line interference was coming from but more importantly did not know there was a fix for it, I will try this out anything, thanks.
@dexterpagsolingan8678
@dexterpagsolingan8678 4 ай бұрын
hi did you already try this? i have same problem
@XAMDX1
@XAMDX1 Жыл бұрын
Excellent Video 👍
@PcParamedics868
@PcParamedics868 2 жыл бұрын
Thanks alot...
@raxvajah
@raxvajah 2 жыл бұрын
When you say seperate the cat5e cables from each other, did you mean do not tie wrap the cables together? e.g. 8 cameras being fed with cat5e how would you keep them separated at the dvr end?
@user-vo1rq8si2z
@user-vo1rq8si2z 3 жыл бұрын
Hi I installed 30 cameras and I have ground loop and interference in most of them Which brand of isolators you recommend Thanks
@richardlarkin4325
@richardlarkin4325 2 жыл бұрын
What do you suggest if at the recorder end, your still getting interference on your test monitor? Test monitors don’t have a ground. What’s the other option recable?
@jasonpoulter3655
@jasonpoulter3655 Жыл бұрын
Hi Paul, Love your videos, theyre a big help, so thumbs up to you. I've just had 3 Hikvision ColourVU 5mp cameras fitted to my home, they have only been up two weeks and one camera has misted over (like condensation) and another has many thin black lines horizontally on the screen. can you possibly tell me what could be causing this ? Kind Regards Jase
@CCTVSystemsUK
@CCTVSystemsUK Жыл бұрын
Hi Jason, Sorry for the late reply, but KZfaq sometimes doesn't send us post notifications. Even though it's a little late, I'll have a crack at this! Any camera can mist over, even brand new ones. Most issues after installation are caused by the cable tail on the rear of the camera being pulled excessively during the installation process. This actually damages to waterproof seal around it. This will let in condensation, as would a slightly misaligned lens seal. Thin black lines sound like one of three issues. 1, The camera cable could be close to a power supply (especially if the installation was done using Cat5e or Cat6e) 2, The connections on either end might need replacing. Eg: Video Baluns etc. 3, the PSU "power supply unit" could need replacing. There are of course many more reasons I can think of so I'd suggest getting a professional to diagnose it for you. P.s As strange as it may seem. A simple movement of the DVR / HVR from left to right in its location can often solve pesky issues like lines on the screen. Hope this helps you in some way. Regards, Paul CCTV Systems UK
@TomyCroSound
@TomyCroSound 3 жыл бұрын
How to solve video interference on the intercom? Will replacing the utp cable fix the thing (up to 20m) or is there any solution without replacing the installation?
@LanceRazon
@LanceRazon Ай бұрын
Hi I've setup a one cat6 cctv, the next day it has no image, its only a 25m run.
@CCTVSystemsUK
@CCTVSystemsUK Ай бұрын
Hi, Put a data cable tester on the cable and test it! 99% of the time it's a duff cable or a bad RJ45 connection on one, or both ends. Use a made up lead to test the camera at the DVR end! This way you can also rule out a faulty camera. Hope this helps. Regards Paul @CCTVSystemsUK
@abraarali739
@abraarali739 3 жыл бұрын
Can I use this if I have a power slitter too
@mohamedchopdat7242
@mohamedchopdat7242 2 жыл бұрын
Hi, Is a ground loop isolator the same as a Video Balun. Does it do the same job?
@CCTVSystemsUK
@CCTVSystemsUK 2 жыл бұрын
Hi No a video balun is a connection used when sending video down cat cable. A ground loop isolator is a piece of equipment to aid removing electrical interface from CCTV systems. Including cat cable. Hope this helps. Regards, Paul CCTV Systems UK
@mohamedchopdat7242
@mohamedchopdat7242 2 жыл бұрын
@@CCTVSystemsUK Thanks for the reply. great video by the way. well explained.
@paulmoor3799
@paulmoor3799 2 жыл бұрын
Grounding one side of your cat5e end to earth can sort a lot of problems too.
@karlmurphy414
@karlmurphy414 3 жыл бұрын
Hi will this work on audio / sound interference thanks
@CCTVSystemsUK
@CCTVSystemsUK 3 жыл бұрын
Hi, They are certainly not designed for audio use but, could possibly quiet sound down due to there ability to remove power interference. . That said, there are ground loop isolators out there designed specifically for audio that are very inexpensive and easily found with an Internet search. Regards, Paul CCTV Systems UK
@gaylekohut1341
@gaylekohut1341 5 ай бұрын
Hi ya I have encounterted a error on 3 of my cams it's like a white rolling line that moves from the bottom to the top of the screen other than this the picture is perfect any ideas matey?
@CCTVSystemsUK
@CCTVSystemsUK 5 ай бұрын
Hi, Ground loop isolators are designed to take out most of the interference in such cases. That sounds to me very much like a light problem! Is there a light nearby? It sounds like a light fitting frequency issue to me. This usually produces horizontal lines moving from bottom to top. If this is the case. Try the camera away from the light source. Hope this helps. Regards, Paul CCTV Systems UK
@gaylekohut1341
@gaylekohut1341 5 ай бұрын
Had my cctv installed for years never had this problem before whatsoever 2 are outdoor cameras and I have a camera indoors do u mean change the position of all the cameras?
@gaylekohut1341
@gaylekohut1341 5 ай бұрын
It's now fixed my cctv installer asked me to reboot the dvdr recorder and hey presto the lines have disappeared
@blamburel
@blamburel 2 жыл бұрын
Can you use this with balloons and cat5?
@CCTVSystemsUK
@CCTVSystemsUK 2 жыл бұрын
Yes you will be able to use them on the DVR end but, the nature of Cat cable EG: unshielded, means that interference in the cable could conceivably be much harder to get out! But yes, you can certainly give it a go. Hope this helps. Regards, Paul CCTV Systems UK
@blamburel
@blamburel 2 жыл бұрын
@@CCTVSystemsUK thanks for your quick reply. Much appreciated!
@michaelsimpson9779
@michaelsimpson9779 Жыл бұрын
The mains AC power cable, twin and earth, is not positive and negtive. Green or green/yellow is Earth and the other two are Active and Neutral. This is not a DC system. It will radiate noise at the local Mains AC supply frquency (50 or 60Hz generally) or a harmonic thereof. In Australia, there is a requirement to maintain about 60mm minimum gap between data/comms and power cabling and it's good practice to avoid parallel runs with AC cabling. The ground loop isolator has a Coaxial cable and connectors. Data cable shown here is UTP, Unshielded Twisted Pair. Cat5 and Cat5e and Cat 6, for example. Data cable also comes in a shielded format for use in locations where there are sources of EMF/RF Interference. Data cables are manufactured in such a way that they minimise Crosstalk. Shielded or Unshielded, there is no need to have them unbundled and in data installs its normal to see backbone data cabling loomed/bundled where it leaves the rack and also travells through the roof cavity. Generally, power in data cabling, POE, or "Power Over Ethernet" is DC, and shouldn't cause any issues within adjacent cables.
@spencermoss5528
@spencermoss5528 3 жыл бұрын
Could this cause me to have no image at all?
@CCTVSystemsUK
@CCTVSystemsUK 3 жыл бұрын
Yes, If the cable is a long length or, not of a premium quality, then it can cause this in rare cases. Regards, Paul CCTV Systems UK
@jeffbasas9381
@jeffbasas9381 2 жыл бұрын
Can we use thatgroud loop on cat 5
@jaywakn7144
@jaywakn7144 3 жыл бұрын
We added one of these cables but now our ptz camera won’t move around. Any ideas?
@CCTVSystemsUK
@CCTVSystemsUK 3 жыл бұрын
Sounds to me like the ground loop isolator is too strong. If your PTZ has stopped moving simply remove the isolator, then if the PTZ resumes it's normal functionality you know that the isolator is blocking the PTZ protocols 'commands'. I know ground loop isolators are not really recommended for PTZ use but, we have installed them on PTZ's with no functionality issues. Try a different manufacturer of isolator would be my advice. Hope this helps. Regards, Paul CCTV Systems UK
@tammybohme
@tammybohme 3 жыл бұрын
@@CCTVSystemsUK Thank you so much. Truly appreciate your assistance.
CCTV camera ground loop (how to fix)
6:25
Learn CCTV
Рет қаралды 23 М.
Inside an audio isolator transformer module.
8:50
bigclivedotcom
Рет қаралды 236 М.
ПРОВЕРИЛ АРБУЗЫ #shorts
00:34
Паша Осадчий
Рет қаралды 7 МЛН
Gym belt !! 😂😂  @kauermotta
00:10
Tibo InShape
Рет қаралды 18 МЛН
ЧУТЬ НЕ УТОНУЛ #shorts
00:27
Паша Осадчий
Рет қаралды 10 МЛН
Removing Earth Loop Interference | How To Fit CCTV Tips
4:02
System Q CCTV
Рет қаралды 22 М.
CCTV Camera Power Supply connection.
8:01
Tech Inside Out
Рет қаралды 48 М.
CCTV Video Interference Quick Fix: Check Your Cables!
10:06
Nelly's Security
Рет қаралды 19 М.
Hikvision Alarm Output Configuration on Acusence HVR / DVR / NVR + Alarm Input (Part 2)
22:23
CCTVSystemsUK (@CCTVSystemsUK)
Рет қаралды 10 М.
How To Fit A BNC PLUG on RG59 CCTV Cable
6:57
Smart Aerials
Рет қаралды 116 М.
Hikvision NVR - The Network is Unreachable (Solution)
11:31
Best Security Devices
Рет қаралды 50 М.
ПРОВЕРИЛ АРБУЗЫ #shorts
00:34
Паша Осадчий
Рет қаралды 7 МЛН