Charging R-410A Refrigerant Into An Air Conditioner Using Wireless Probes!

  Рет қаралды 24,700

AC Service Tech LLC

AC Service Tech LLC

19 күн бұрын

In this HVAC Training Video, I Show How to Use Wireless Probes to Check the Refrigerant Charge and How to Correctly Charge R-410A Refrigerant into this Running Air Conditioner! Technicians Must be EPA 608 Certified to Handle Regulated Refrigerants! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In The Video:
Fieldpiece Complete Job Link Probe Kit - trutechtools.com/Fieldpiece-C...
Fieldpiece STA2 Thermal Anemometer Hotwire AirFlow Meter trutechtools.com/STA2?aff=8
Hilmor RSWL220 Wireless Refrigerant Scale 220lbs trutechtools.com/hilmor-rswl2...
At Trutechtools.com use code acservicetech for 8% off
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos:
• Charging R-410A into a...
• Charging an R-410A AC ...
• R-410A Charging and Re...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicetech.com/store
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicetech.com/hvac-ca...
Our Newest Articles: www.acservicetech.com/articles
Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
Our Other Resources: www.acservicetech.com/resources
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicetech.com/tools
Our Tool List on Amazon: www.amazon.com/shop/acservice...
Support the Channel by purchasing tools through Tru Tech Tools!
Use this link www.trutechtools.com/?aff=8
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.com/show/74KXLz5...
Apple Podcasts: podcasts.apple.com/us/podcast...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #hvactechs #technician #training #airconditioner #airconditioning #r410a #charge #checkingthecharge #refrigerant #refrigerantcharging
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 81
@deanmartin1966
@deanmartin1966 18 күн бұрын
Excellent video Craig. I do love my fieldpeace probes.
@deanmartin1966
@deanmartin1966 14 күн бұрын
I'm sure I've said it before, but thanks for all the great free information you and all the other great teachers provide. Such a wealth of knowledge. I'm 58 and I absolutely hated high school. Until I got into the trades. Then surprisingly I became an "A" student. I seriously love the trades and think its a great alternative to a four year college. My grand daughter is 15 and wants to become a welder. She makes me proud. Once again, thanks. Phil
@paulrmfd
@paulrmfd 16 күн бұрын
absolutely instructional keep up the good work
@manueldacosta6539
@manueldacosta6539 18 күн бұрын
Excellent video as always, thank you.
@jorgemanzano7232
@jorgemanzano7232 18 күн бұрын
Well explained! Thank you very much 😊
@electrolatif
@electrolatif 16 күн бұрын
The best aircon video in KZfaq ❤
@repairitdontwreckit4257
@repairitdontwreckit4257 17 күн бұрын
Thanks. Nice job.
@AndyHoltOutdoorUniversity
@AndyHoltOutdoorUniversity 10 күн бұрын
Nice job, Craig!
@gingerstrand6153
@gingerstrand6153 17 күн бұрын
Great video, thank you!!
@snwsk8
@snwsk8 10 күн бұрын
Great tips as always, thank you
@zahedaminullah6934
@zahedaminullah6934 17 күн бұрын
Great video man!
@TheWathever516
@TheWathever516 17 күн бұрын
Great video!
@kennethlobo4420
@kennethlobo4420 17 күн бұрын
Well explained ❤
@yannkitson116
@yannkitson116 18 күн бұрын
Great video, I have Testo probes and a slightly different app but it is all the same in the end :)
@pongobongo2295
@pongobongo2295 17 күн бұрын
Use Appion charging tees. This is my go to charge set up. Also, get a third probe and map to outdoor air temp.
@edwardlouie
@edwardlouie 17 күн бұрын
I like using core depressors so I don't need to spin on/off quickly.
@APHVAC0913
@APHVAC0913 18 күн бұрын
Great video 👌🏽
@butlerstouchHVAC
@butlerstouchHVAC 17 күн бұрын
great vid
@kastenusa
@kastenusa 17 күн бұрын
Can you please make a video on where to connect probs on package unit correctly. Thank you!
@cryptkeyper
@cryptkeyper 17 күн бұрын
I second this
@mohdrifi1930
@mohdrifi1930 18 күн бұрын
Excellent! You need to do this method to ac split unit also! Appreciate your effort teacher! ❤️❤️❤️❤️
@cryptkeyper
@cryptkeyper 17 күн бұрын
This is a ac split unit
@jericosha2842
@jericosha2842 16 күн бұрын
This doesn't work on mini split ductless if that's what you mean
@mtbbiker6401
@mtbbiker6401 16 күн бұрын
I don't understand how taking a low pressure (vapor line) reading at the condenser translates to the pressure in the evaporator. Why is it not industry standard to take low pressure (vapor line) reading at the evaporator?
@vonboldler5219
@vonboldler5219 17 күн бұрын
Hi mike!
@lorunner1213
@lorunner1213 13 күн бұрын
Craig. Does the outdoor Dry bulb temp matter if being read from the sunny side of the condenser vs the shady side?
@NickNameNemo
@NickNameNemo 8 күн бұрын
If system has leakage (r410a) and still remains some amount of refrigerant, let’s say 70-80% of total, should I recover all refrigerant from system and charge it with new or just add needed amount?
@justinhughes452
@justinhughes452 16 күн бұрын
What was the recommended amount of refrigerant on the name plate? How much was in system at the start and what was the total amount at the rnd of this demonstration?
@arthurrabon9349
@arthurrabon9349 8 күн бұрын
multi zone split unit question. if you have 3 zones and 1 zone is having troubles meeting set temp. how does system respond.
@povoljan13
@povoljan13 15 күн бұрын
The charging hose has air when you hooked it up to the tee. The small space after the shutoff valve is dead air space. Needs a better setup maybe?
@pana5075
@pana5075 17 күн бұрын
Espero este video en español
@JuanJuarez-en5xn
@JuanJuarez-en5xn 13 күн бұрын
Where can I buy those T’s that go on your probes do you have a link to them ?
@monstaro19
@monstaro19 8 күн бұрын
We need a way to use this in cars its 106 in Florida
@globecomputers1
@globecomputers1 17 күн бұрын
Great video! Like always! Question can you provide a link for those AC test caps? I need to buy a set.
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs 16 күн бұрын
Just take two spare caps and drill a hole in them.
@user-ry6ii8ql2p
@user-ry6ii8ql2p 20 сағат бұрын
? What is the link for the brass tees to purchase sir. Thank You.
@wpl11972
@wpl11972 17 күн бұрын
I just use my valve core removal tool as my tee.
@emidiolopez1409
@emidiolopez1409 17 күн бұрын
So you remove the schrader valve to do SH or SC? Or what kind of removal tool do you use that has a press tool built in? Because the Appion that I use don’t have the press tool so I can’t take any risk of losing 5+ pounds of refrigerant by removing the schraders lol
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs 16 күн бұрын
@@emidiolopez1409if your loosing 5 lbs with a core removal tool you’re using it wrong. How much refrigerant are you going to lose I’d the schrader doesn’t seal?
@emidiolopez1409
@emidiolopez1409 16 күн бұрын
@@HVAC_Tips_Tricks_Calcs Ive never said I’m losing 5 pounds by using the schrader removal tool. I said that’s just stupid if you have to remove the schrader valves every time you have to check the pressures on an AC, NO way I’m taking risks in losing factory refrigerant if something doesn’t goes bad with the removal tool.
@var8492
@var8492 3 күн бұрын
What if my liquid pressures are at 390 and suction 174 with a 11 t/s !??
@tomaszpoznanski7584
@tomaszpoznanski7584 17 күн бұрын
Iam a contractor and would like to do a course/training for a/c contractor. Can you recommend any in NY/NJ/PA area? Any schols?
@JuanJuarez-en5xn
@JuanJuarez-en5xn 17 күн бұрын
Can you make a video on RTU’S?
@mackenziegray2090
@mackenziegray2090 16 күн бұрын
It's the samething. What part confuses you?
@mikev.1034
@mikev.1034 18 күн бұрын
👍👍
@pitaeata8493
@pitaeata8493 17 күн бұрын
need tips and tricks to determine if a system has a piston or txv. Sometimes on UNCASED coils it is impossible to remove the front of the field made cover to get a look.
@sir.cannabis1173
@sir.cannabis1173 17 күн бұрын
I'm thinking one could tell by how fast the numbers move. Craig mentioned it might take 15 minutes for pressures to equalize with a fixed.
@mackenziegray2090
@mackenziegray2090 16 күн бұрын
If you see a threaded union outside the case, chances are you got a piston.
@turnedearthdesign8678
@turnedearthdesign8678 11 күн бұрын
Also check the chart on the condenser. It usually (but not always) tells you what the pressure of one of the lines should be which should match up to the metering device used
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs 16 күн бұрын
Although I’m sure sponsored, nice to see someone make a video that didn’t say you had to use MQ and True Flow or you’re a hack.
@davidlopan6649
@davidlopan6649 17 күн бұрын
I can see myself pulling the pressure probes off the T and accidentally letting out all the refrigerant. lol definately would put a valve core on that for me.
@lorunner1213
@lorunner1213 13 күн бұрын
I use apion tee’s. They are low loss with schraders on both male ends of the tee. So doesn’t matter if you pull just the probe off. Or the tee with the probe.
@davidlopan6649
@davidlopan6649 13 күн бұрын
@@lorunner1213 Yeah I love appion tools. Just purchased their recovery machine. I didn't get probes yet probably next year.
@JuanJuarez-en5xn
@JuanJuarez-en5xn 13 күн бұрын
Where did you bought those T’s ?
@lorunner1213
@lorunner1213 13 күн бұрын
@@JuanJuarez-en5xnJohnstone Supply
@Ahmed198831
@Ahmed198831 16 күн бұрын
🙏🙏🙏🙏
@edwardlouie
@edwardlouie 17 күн бұрын
This method doesn't always work with inverter variable speed equipment that change the superheat target based on various logics.
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs 16 күн бұрын
Inverters usually don’t have fixed orifices.
@jimwhite9483
@jimwhite9483 16 күн бұрын
How hard would it be for Fieldpiece to add a wireless input for ODDB in the app or on the SMAN 380V?
@turnedearthdesign8678
@turnedearthdesign8678 11 күн бұрын
You can link one of their psychrometer probes to the outdoor dry bulb
@hazendismukesjr.8319
@hazendismukesjr.8319 17 күн бұрын
😂why didn't you use a charging orifice
@Bigdawg_74
@Bigdawg_74 17 күн бұрын
sadly most techs will hook up and immediately say it's good or needs refrigerant because companies are so focused on getting techs in and out as fast as possible. Most expect a complete diagnosis to be complete in 30 min max preferably less.
@TheRealDegen100
@TheRealDegen100 14 күн бұрын
Preferably way less but every call is different. Only calls that really take time is determination of why a part failed.
@kevinpearce3281
@kevinpearce3281 18 күн бұрын
Why can’t you put the r410a into the liquid side if it’s coming in as a liquid
@davidgochenour7072
@davidgochenour7072 18 күн бұрын
It would push refrigerant into your bottle
@camilo8cheryl
@camilo8cheryl 18 күн бұрын
High pressure
@WhatIsYourCard
@WhatIsYourCard 18 күн бұрын
The liquid side is at a high pressure while the system is running. Connecting the refrigerant jug to the suction line, which is a lower pressure, will suck the refrigerant into the system.
@wyattdekay7763
@wyattdekay7763 17 күн бұрын
Usually to much pressure
@boongoon92
@boongoon92 17 күн бұрын
It's leaving as a liquid
Troubleshooting With Sat Temps, Superheat, & Subcooling! 5 Possible Problems!!
18:48
"Flammable" Refrigerant Facts for Residential HVAC
1:02:01
HVAC School
Рет қаралды 42 М.
I CAN’T BELIEVE I LOST 😱
00:46
Topper Guild
Рет қаралды 119 МЛН
Digital HVAC Gauges or Wireless Probes | Which should YOU buy??
17:00
Explaining Superheat and Subcooling to Your Apprentice!
14:14
AC Service Tech LLC
Рет қаралды 586 М.
I Bought a $5000 PC in a Random Asian Tech Mall
22:12
Linus Tech Tips
Рет қаралды 6 МЛН
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,4 МЛН
Typical HVAC unit LEAKING refrigerant & How I Fixed it.
17:37
Quality HVACR
Рет қаралды 33 М.
DIY Tutorial - Proper R134a A/C charge & Diagnostics
18:14
My Honest Review
Рет қаралды 111 М.
MINI SPLIT Parts Explained! Understand What They Do!
19:31
AC Service Tech LLC
Рет қаралды 619 М.
How To Use AC Gauges
26:34
Benjamin Sahlstrom
Рет қаралды 1,2 МЛН