Column ல இவ்வளோ தவறு செய்யரோம்மா | Distance between two column in tamil | Column கம்பி கணக்கிடு

  Рет қаралды 35,312

Civil Cognition in Tamil

Civil Cognition in Tamil

3 жыл бұрын

Column ல இவ்வளோ தவறு செய்யரோம்மா | Distance between two column in tamil | Column கம்பி கணக்கிடு
For any queries contact
Er.P.Kaviyarasan B.E
6383126242
Kallakuruchi
Hi,
In this video we are going to see about the mistakes in column what we are doing in site and also it enclosed about column shape ,size and rebar for that column
Column is one of the back bone of building to ensure the durability of the building we should have to design column based on the loads
so while constructing a building it is recommended consult a structural engineer or Engineer with quiet good knowledge in structural detailing
#Column ல இவ்வளோ தவறு செய்யரோம்மா
Distance between two column in tamil
#Column கம்பி கணக்கிடு
#Distance between two column in building
#civil in tamil
#different types of column in tamil
#column bar calculation
#column shape and size
plz like share and subscribe
thank you

Пікірлер: 59
@jeenjk2505
@jeenjk2505 4 ай бұрын
Very useful video bro...ithulam na therinjikka 5 yrs aachi bro...so very thankful
@ganesanmala8746
@ganesanmala8746 2 жыл бұрын
அருமை. அனைவருக்கும் எளிமையாக புரியும் படி தெளிவாக உள்ளது. உங்கள் முயற்சிக்கு வாழ்த்துக்கள்.
@balasubramanyanramasubrama6202
@balasubramanyanramasubrama6202 Жыл бұрын
Easily understandable. Excellent description. Useful
@civilcognitionintamil8634
@civilcognitionintamil8634 Жыл бұрын
Thank you
@pradeepstunner518
@pradeepstunner518 3 жыл бұрын
wowww👌🏻👌🏻 vera level brother... easy to understand😇
@civilcognitionintamil8634
@civilcognitionintamil8634 3 жыл бұрын
✌️😁
@nevergiveup5784
@nevergiveup5784 3 жыл бұрын
Superb bro..well explained..informative content..keep rocking..👍
@civilcognitionintamil8634
@civilcognitionintamil8634 3 жыл бұрын
Thanks lyf lover😁👍
@Sakthis007
@Sakthis007 Жыл бұрын
Relly romba useful வீடியோ சகோ 👏👏👏💐
@civilcognitionintamil8634
@civilcognitionintamil8634 Жыл бұрын
நன்றி சகோ
@kumarasamy4111
@kumarasamy4111 2 жыл бұрын
Superb
@iFindEvil
@iFindEvil 15 күн бұрын
Cool👌🏻
@hariarul585
@hariarul585 2 жыл бұрын
well explained . thanks. keep continuing
@civilcognitionintamil8634
@civilcognitionintamil8634 2 жыл бұрын
Thanks brother
@dhanushkodi7861
@dhanushkodi7861 4 ай бұрын
15 feet distance vandha column size epdi podanum bro...
@SivaKumar-ls3bj
@SivaKumar-ls3bj Жыл бұрын
Super
@ramuramu-gj1nd
@ramuramu-gj1nd 8 ай бұрын
I liked your comment thank you
@jeenjk2505
@jeenjk2505 4 ай бұрын
Bro but vera oru video paarthen but avunga colum middle ahh avunga stirups spacing kammiya kudukka sonnanga but neenga middle than bending moment 0 so spacing athigama ahh kuduthukulanu solluringa
@civilcognitionintamil8634
@civilcognitionintamil8634 4 ай бұрын
Yes bro, correct Column centre la bending moment zero so athanala athumari namba pannalam. Eg. Column Center la (L/4) distance 150mm c/c spacing use pannalam , top and bottom (L/4) la 125mm c/c spacing use pannalam (this spacing are just for assumption)
@Traveldiaries_hk5cw
@Traveldiaries_hk5cw Жыл бұрын
Column cover should be 40mm which means 1.5” approx
@dharanidhamarai2545
@dharanidhamarai2545 Жыл бұрын
🙏👏👏
@arthichandrasegaran3071
@arthichandrasegaran3071 3 жыл бұрын
Keep going bro😌
@civilcognitionintamil8634
@civilcognitionintamil8634 3 жыл бұрын
😊✌️
@esjesus8943
@esjesus8943 3 жыл бұрын
Nice video bro👍
@civilcognitionintamil8634
@civilcognitionintamil8634 3 жыл бұрын
Thanks ni✌️😊
@mcm5937
@mcm5937 3 жыл бұрын
Super pa
@civilcognitionintamil8634
@civilcognitionintamil8634 3 жыл бұрын
Thanks bro✌️😊
@kiruthikakittu5799
@kiruthikakittu5799 3 жыл бұрын
Good 👏
@civilcognitionintamil8634
@civilcognitionintamil8634 3 жыл бұрын
👍
@darshananbu4037
@darshananbu4037 Жыл бұрын
Maximum percentage of steel 4% not 6% as per is456 code. Can't pour concrete properly if provide more steel. Darshan (Structural Engineer)
@civilcognitionintamil8634
@civilcognitionintamil8634 Жыл бұрын
Yeah as per is 456 the area of longitudinal reinforcement in column must not be less than 0.8% and must not exceed 6% of column gross area but however in practice, maximum reinforcement of 4% is recommended
@thirumurugan5270
@thirumurugan5270 Жыл бұрын
சூப்பர் மிக அருமை 1 1/4 3\4 எத்தனை கம்பி இருக்க வேண்டும் தம்பி
@civilcognitionintamil8634
@civilcognitionintamil8634 Жыл бұрын
தோராயமாக g+1 கட்டிடத்திற்கு 1'3"x9" - 16mm - 6nos அல்லது 16mm - 4nos & 12mm- 2nos போதுமானது.
@sunithavenkat3897
@sunithavenkat3897 Жыл бұрын
hello sir. one feetla paarai 4 feet pallam.irukra placela G+2 houseku endha size kambi pillar podavendum.
@civilcognitionintamil8634
@civilcognitionintamil8634 Жыл бұрын
Hi please contact me through WhatsApp, whatsapp number in video description
@sakthilingam643
@sakthilingam643 Жыл бұрын
Super anna
@civilcognitionintamil8634
@civilcognitionintamil8634 Жыл бұрын
Thanks bro
@jules8063
@jules8063 10 ай бұрын
Hi bro Nanga kattura veetula first floor column, ground floor column size vida chinntha iruku. 1 or 2 inch reduce pannitanga. Is that recommended?
@mohanv4916
@mohanv4916 10 ай бұрын
Its Not big problem.... Load reduce panirupanga.... Suppose 3rd floor build panina prblm varum.... Only 2 floor no prblm
@shanthimani8660
@shanthimani8660 6 ай бұрын
600sqft 12 columns 4nos 12mm rods 2nos 10mm rods this correct or incorrect
@mithrannila2018
@mithrannila2018 2 жыл бұрын
sir en veedu 220squre feet 6 Calume poatangha . 1 Calum 12mm 4 numbers poatangha sariya?
@civilcognitionintamil8634
@civilcognitionintamil8634 2 жыл бұрын
Ground floor mattumna problem ethum illa madam
@infantmanickaraj2330
@infantmanickaraj2330 2 жыл бұрын
Bro ithu maathiri beam ku video podunga bro
@civilcognitionintamil8634
@civilcognitionintamil8634 2 жыл бұрын
Kandipa video make panren brother keep supporting
@infantmanickaraj2330
@infantmanickaraj2330 2 жыл бұрын
Sure bro
@praveenkumar-xw8de
@praveenkumar-xw8de Жыл бұрын
9*9 column g+1 ok vaa bro
@iam_mohans6794
@iam_mohans6794 2 жыл бұрын
Sir, outer to outer 11.5 ft ku 31 ft 1 bhk katrom athuku 9 " by 9 " post pothuma future la maximum 2 floor kattuvom athuku 9" by 9 " post pothuma sir please reply
@civilcognitionintamil8634
@civilcognitionintamil8634 2 жыл бұрын
Sir 9"*9" column oru maadi (g+1) building ku pothum G+2(2 floor) building ku 1'*9" column 10ft distance la kudunga pothum Mukkiyamana vishiyam roof la beam kudunga
@iam_mohans6794
@iam_mohans6794 2 жыл бұрын
@@civilcognitionintamil8634 okay sir Thank you so much sir
@iam_mohans6794
@iam_mohans6794 2 жыл бұрын
@@civilcognitionintamil8634 sir g+2 floor ku 9" by 1' post ku enna size rode podanum
@raghuprasath7631
@raghuprasath7631 2 жыл бұрын
@@civilcognitionintamil8634 thank you sir
@mohanv4916
@mohanv4916 10 ай бұрын
45*d 45*16=2.5f 2.5f எப்படி வந்தது....??? புரியல
@civilcognitionintamil8634
@civilcognitionintamil8634 10 ай бұрын
1ft=304.5mm 45d=45*16 = 720mm =720/304.8 = 2.36m ~2.4m
@ashokdavid108
@ashokdavid108 3 жыл бұрын
Column gap athigama vuta top load atgugama irutha danger dhana
@civilcognitionintamil8634
@civilcognitionintamil8634 3 жыл бұрын
G floor ku 15 ft varayu prblm varathu(9"*9") ok ......bt (g+1) ku 15ft ku (9"*9") set agathu...Gap athigama achina column and beam size increase agum bro and also depend on floor no's...vara load ah column beam handle paniku....
@ashokdavid108
@ashokdavid108 3 жыл бұрын
@@civilcognitionintamil8634 sila v2la pathuruken athan keten Avanga again center la beam poduvanga Load poruthu nama 1st le beam size maximum panikita nalathu
@civilcognitionintamil8634
@civilcognitionintamil8634 3 жыл бұрын
Ama bro main beam ah strong ah kudutha pothu ....naduvula beam theyvapadathu........
@kannanchinnaiyan4069
@kannanchinnaiyan4069 Жыл бұрын
Super
@Gksen007
@Gksen007 Жыл бұрын
Super
THEY made a RAINBOW M&M 🤩😳 LeoNata family #shorts
00:49
LeoNata Family
Рет қаралды 18 МЛН
I wish I could change THIS fast! 🤣
00:33
America's Got Talent
Рет қаралды 101 МЛН
I CAN’T BELIEVE I LOST 😱
00:46
Topper Guild
Рет қаралды 91 МЛН