I had several test test leads that I had accumulated in the last couple of years. Most had never been taken out of the box.
In this video, each set of probes was attached to my older generator to see if they would breakdown at 15KV. I then connected the probes to a constant current source to measure their power dissipation. The worse probes were then tested to failure.
Below, the brand, overall length, wire insulation OD, Resistance at 4A, Gold Plate
CENTECH, 32", 0.02", 0.375
Agilent, 55", 0.05", 0.047
Fluke (101), 55", 0.05", 0.047
HIOKI, 43", 0.04", 0.043, gold
AMPROBE, 42", 0.04", 0.041
Brymen, 46", 0.045, 0.033, gold
KLEIN, 41", 0.045", 0.150
Mastech (plain), 40", 0.04", 0.074
VICI, 42", 0.042", 0.084
Mastech (gray), 41", 0.04", 0.026
ProbeMaster, 46", 0.04", 0.031, gold