We had a unit having a high discharge temperature which stops the unit and go out of range. here is the troubleshooting video I did in fixing this unit • REFRIGERATED CONTAINER... • TROUBLE WITH DAIKIN RE...
Пікірлер: 51
@user-hd7nj9bp4q3 ай бұрын
Thank you sharing the reefers stories that couldn't teach in school😊😊😊
@ChandanaPriyantha-pq3uv2 күн бұрын
Thank you sir for the technology of new generation,I am interested
@digitald58512 жыл бұрын
The old pump and dump lol. Love the videos.
@thamizhselvan71812 жыл бұрын
Very useful 👍
@michellewu0019642 жыл бұрын
Thank you for your help, it's really helpful, thanks again
@svyat87102 жыл бұрын
Thanks a lot for this video
@6Diego1Diego92 жыл бұрын
this guy is so good. so smart.
@kevincalonia5495 Жыл бұрын
Salamat sir Lecky marami akong natutunan sa inyu i hope sunod maging isa ako sa maging Cadet Electrician nyu po at assistant po😊
@calbear15032 жыл бұрын
Thank brotha for the videos
@kyryl5673 Жыл бұрын
Hi, Jake! Safety First! For everybody: from the begining do not forget to check Freon type. Sime times we do simple mistake, and later on we do double job! Best regards and good luck!
@garywebb42442 жыл бұрын
Finding leaks can be painful to find when your on board ship. A lot of times I’ve found that the nut at the base of the high pressure valve or the low pressure valve is loose and leaking refrigerant. It’s important to check that nut anytime you’ve opened the valve.
@derrickenbuenosaires2 жыл бұрын
Hi leckyjake, I always admired marine refrigeration. If I was contracted to do some work on a ship I would go just to try it out for once. I've worked on a couple of the transicold 69NT40 models and always wondered about the sight glass. There are two sight glasses on the receiver. A proper charge is around 5kg I think but the ball always remains pretty low on the visor. I see yours here went up pretty high. I assume the ball on the top visor should not float unless you are pumping down
@habagatbrown98422 жыл бұрын
Goodjob sir
@fazlul29302 жыл бұрын
Nice video
@syedbasheer82102 жыл бұрын
👍👍👍
@roelanddejonghe46942 жыл бұрын
Nice stagging 😉 did you find a leak or oil?
@syedbasheer82102 жыл бұрын
👍👍👍✅
@sailorlifeisbeautiful61802 жыл бұрын
Sir ,please make video about megger testing
@Vivek045812 жыл бұрын
Hi, do you have any video for msb breaker under voltage trip.
@JohnFlanagan-hs1fv6 ай бұрын
Frontseat the discharge service valve and jump out the high pressure switch. Start unit and run
@toyinorodare40722 жыл бұрын
I love you training kudos Why was the leakage not fixed instead of recharging new Freon gas?
@rashad43332 жыл бұрын
If he could use a pump to pull a vacuum there’s no leak. Air could have gotten into the system from someone not clearing gauges.
@moksmekanikongpandagat5256 Жыл бұрын
elek id like to ask you if you have experienced high temperature alarm then the oil seems to disappear. this on a chiller for an inert gas generator.
@domalexus19912 жыл бұрын
I encountered that trouble sir, found out that freon leaked in the condenser coil
@danishmomin810210 ай бұрын
Reefer Compressor, Bitzer Type VI. Head temperature going very high, Compressor disch temp almost 95. Checked cooling water flow, passages in head cleaned , condenser cleaned. Valve plate renewed
@danishmomin810210 ай бұрын
But still temperature is very high. Kindly suggest what else to check
@TITUSITHOKA-ts9jl4 ай бұрын
@@danishmomin8102Check if the compressor has enough oil and if the discharge pressure sensor is okay
@TARUNAKARYA199410 ай бұрын
what triggers the low pressure temperature alarm? to -30°C, compressor pumpdown at -25°C 🙏🙏 Thanks sir...
@aripediaproject11132 жыл бұрын
How many person as an electrician or assistant electrician on your vessel ?
@NivagSwerdna2 жыл бұрын
So there is a leak? Does this get recorded for testing when the container is offloaded?
@ChoroTesla2 жыл бұрын
I dont think if they are recorded it but its going to inspected well when the cargo is distuffed and the unit PTIed again and doing more leakage testing.
@hakhakuuba50732 жыл бұрын
Our Daikin reefer compressor is not working. In Mongolia nobody can fix it..
@mlenstra2 жыл бұрын
Any idea where the refrigerant from the system went? Was there a leak you found and fixed?
@Gin-toki2 жыл бұрын
Yeah, a leak seems highly possible, which means the problem will just return after some time. Could perhaps also be that it got air trapped during its previous maintenance.
@mlenstra2 жыл бұрын
@@Gin-toki at least here in the Netherlands (I think all EU countries) I’ve come to understand it’s actually illegal to refill a suspected leaking system with fluorinated refrigerant as it’s extremely bad for the environment to get these gases into the atmosphere. Not sure what type of refrigerant this reefer is using though, might be plain CO2 these days for all we know.
@Gin-toki2 жыл бұрын
@@mlenstra it was stated in the video that it's freon.
@nunez23j12 жыл бұрын
It was R134a a refrigerant not a Freon, if you go by bottle color (orange) it’s R404 a refrigerant not a Freon.
@xrpengr.5742 жыл бұрын
is it allowed in your company to purge out the refrigerant nto the atmosphere..
@rajatawasthi4769 Жыл бұрын
Nobody seen in middle of the sea .
@Venom-iz4de2 жыл бұрын
Hi,i have additional question ,have mail or something similarly where can i contact You?
@navadaspencer7252 Жыл бұрын
Hi really need your help having trouble clearing a alarm cord Al 58 Compressor High Pressure Safety (HPS)
@leckyjake Жыл бұрын
how much os your discharge pressure?
@rajatawasthi4769 Жыл бұрын
We are doing everything but unit running 4-5 hr good and again it will give high dicarge pressure may be it's TXV give advice plz?
@geronocampo7630 Жыл бұрын
Sir paano po nagwowork ang accumulator sa compressor ?
@danharoldsebastian75042 жыл бұрын
Good morning sir leckyjake. BSEE student po ako at graduating na po. after po mag board exam nagbabalak po ako maging katulad nyo po na eto. bale naaral ko na po mga dapat ko gawin para maging eto. tanong ko lang po ano po ang mga training or tesda courses na dapat kong pasukin para po ngayon palang magkaron na ako ng knowledge sa pag troubleshoot ng ibat ibang machines na ginagamit sa barko. maraming salamat po
@LeckyKenTv Жыл бұрын
Refrigeration and Aircondition (RAC). Pag may budget ka. Marine refrigiration. 10k atah yun sa MERALCO😊
@wickedxe2 жыл бұрын
My guess would be a dirty condenser or a failed condenser fan
@rightconditions27892 жыл бұрын
Yes, that was what I was thinking. It is very uncommon to have "air" or noncondensables in the system even when the sysntoms are similar. The refrigeration troubleshooting was not that good. I had never seen low side pressures and high side pressures unless it is a restriction. (Constructive critc here)
@derrickenbuenosaires2 жыл бұрын
@@rightconditions2789 the containers run at a really low pressure using 134A. Depending on your temp conditions they can range from 5 to down below 0 psi which would be vacuum. (more prone to air infiltration) His high side was definitely high for 134A. That's like a 65+ C / 150+ F coil. Discharge temps directly from the compressor would be way higher. Usually a high discharge would reflect back onto the suction slightly but he was in range on the suction pressure. My first thought would be to look at the coil too but we didn't get to see it. The fan is easy to test since it cycles on and off due to pressure control
@natureraj9282 жыл бұрын
Sir I want job has a assistant electrician in your under