compressor tripping problem, 5 minutes chalker compressor band ho jata hai, compressor heat kyu ho rha hai, compressor jada ampare kyu le rha hai, compressor Strip problem, ac thodi der thanda karta fir garam hawa fekne lagta, compressor kaise check kare, ac condenssor flushing, capillary aur filter kaise change kare, ac thanda nahi ho rha kya kare, ac garam hawa fek rha hai, ac ka compressor kaise check kare, ac choke ho gayi kya kare, ac me gas kitani honi chahiye, patel and brothers, patelandbrothers, एसी बार बार ट्रिप कर रहा है,
एसी का कम्प्रेसर हीट हो रहा है, पटलपटेल ऐण्ड ब्रदर्स, compressor heat problem in fridge, compressor heat kyu hota hai in hindi, compressor garam hoke band ho ja rha hai, compressor thodi der chalta hai band ho jata hai, compressor se awaj aa rahi hai, compressor heating problem, compressor nahi chal rha hai, compressor animation working, compressor heating fridge in English, compressor heating , ac ka compressor trip ker rha hai, fridge ka compressor trip ker rha hai, ac on hote hi voltage drop hota hai, ac chalu hota lekin thanda nahi karta,ac compressor tripping problem
types of Compressor
• Types Of compressor#कम...
relay kya hoti hai
• रिले क्या होती है, रिल...
refrigeration cycle
• रेफ्रिजरेशनसाइकिल# ref...
Working Of Compressor
• Working Of reciprocati...
relay ka connection
• रिले का कनेक्शन कैसे क...
hvac plant
• HVAC Plant# चिलर प्लां...

Пікірлер: 860
@armysoldier8980
@armysoldier8980 3 жыл бұрын
Maan gaye bhai sahab....agar aap k jaisa technician mil jaye to kabhi bhi bina ac k nahi sona padega.
@jaiprakashyadav9902
@jaiprakashyadav9902 2 жыл бұрын
Hi , I am working on Power and Air conditioning system from last 19 years in Defence, you explained all related faults very clearly, correctly and in a very cool manner that I recollected my 19 years experience during your video. Kudos..for the great work
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Thanks 🙏
@stutigupta9937
@stutigupta9937 Жыл бұрын
Can I get ur number
@baburathore9000
@baburathore9000 4 жыл бұрын
very knowledgeable video and super uploading, Bhai very helpful for RAC engineer who are fresh in RAC line 👍👍👍👍👍👍👍👍👍👍👍👍
@syedabbasali3673
@syedabbasali3673 2 жыл бұрын
Samjhane ka Tarika bahut achcha hai ful jankari ke sath ek Salah samjhane ke liye aap Jin shabdon ka istemal karte Hain UN shabdon ko Hindi aur English donon ka prayog Karen
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Thanks for your valuable advice
@praveenmalhotra159
@praveenmalhotra159 3 жыл бұрын
Subscribed. Nice Video good information and very helpful
@SangeetaNigamCreative
@SangeetaNigamCreative 4 жыл бұрын
Great video plz.stay connected
@AvdheshKumar-ip9nk
@AvdheshKumar-ip9nk 11 ай бұрын
Thanks
@kingofnawab3603
@kingofnawab3603 2 жыл бұрын
Sir app bahot acha samjha rhe ho
@indianankitpatel1135
@indianankitpatel1135 Жыл бұрын
Bhut hi acche se btaya apne
@sarmad8965
@sarmad8965 Жыл бұрын
Amazing information 😮
@dushyantkumarchandel8005
@dushyantkumarchandel8005 3 жыл бұрын
Very nice explanation...👌👌👌
@jamilahmed4157
@jamilahmed4157 3 жыл бұрын
Aap ke tips buhat umda aur karamad hote hain, MERA SPLIT AC 1 ya 2 Ghante tak chalne ke baad tripp hojata hai, specially dopahar 12 ya 1 bajay ke baad trip hota hai, bus fan chalta hai. Mehrbani kerke mere problem ko point out kerke solution bataden. Thanks.
@patelandbrothers
@patelandbrothers 3 жыл бұрын
Dopahar me bahut dhup hone ke karan aapka compressor band ho jata hai ager direct dopahar ki dhup aapke outdoor per pad rahi ho to us per kuchh chaanv ker dijiye
@praveenmalhotra159
@praveenmalhotra159 3 жыл бұрын
Nice video, Hitachi Window AC switch off automatically at night, works fine during the day. Filter was dirty blocking the airflow. Subscribed 👍
@patelandbrothers
@patelandbrothers 3 жыл бұрын
poora ac band ho jata hai ya sirf compressor
@praveenmalhotra159
@praveenmalhotra159 3 жыл бұрын
@@patelandbrothers Sirf compressor
@patelandbrothers
@patelandbrothers 3 жыл бұрын
aapka compressor kafi der chalne ke baad heat ho rha hai service na hui ho to karwa lijiye, room poora packed hona chahiye, aisa bhi hai kya ki night me light ka voltage kam hota ho
@praveenmalhotra159
@praveenmalhotra159 3 жыл бұрын
Thank you for your valuable feedback and advice. Service could be the culprit behind the anamoly.
@poojawalia8251
@poojawalia8251 2 жыл бұрын
@@patelandbrothers hmm
@ashtonvz8509
@ashtonvz8509 Жыл бұрын
Best explained... Great job.
@RajKumar-pp9ll
@RajKumar-pp9ll 3 жыл бұрын
graet points Sir, keep it up
@lgltd394
@lgltd394 3 жыл бұрын
Aapko ek point aur add karna chahiye tha ki ager compressor me oil kam hoga to bhi compressor heat hoga
@sushildubey7973
@sushildubey7973 2 жыл бұрын
Lakin bhai ye sautition bhoot km aati h
@missmingling5620
@missmingling5620 4 жыл бұрын
Great video, keep it up👍 ur new frnd here😊
@yogeshsaxsena3326
@yogeshsaxsena3326 3 жыл бұрын
Brother aapke sare video gajab hain
@Harshityadav-wb5si
@Harshityadav-wb5si 7 күн бұрын
good
@hindrajlahare5940
@hindrajlahare5940 3 жыл бұрын
SAHI AC ENGINEERING PAHLI BAR YOU TUBE PAR MILA MUJHE THANK ALOT🙏🙏🙏🙏🙏
@patelandbrothers
@patelandbrothers 3 жыл бұрын
🙏🙏🙏
@divjotsingh3904
@divjotsingh3904 2 жыл бұрын
Sir hamera room pe mitsubishi heavy industries ac lga hua hai usme compressor drip kr rha hai toh plzz aap btaye kya kre Hmne kisi wrkr ko bulaya usne bola gas km haii Aab toh gas b dalva lyi fr b same prblm a rhi haii Plzz suggest kre Boht pareshsn hai hm Sari raat bche so nhi pate
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Kitane minute chalne ke baad trip Hota hai
@divjotsingh3904
@divjotsingh3904 2 жыл бұрын
@@patelandbrothers 3-4minutes
@mihirpawar8930
@mihirpawar8930 Жыл бұрын
Sir i have lg 1.5 ton ac its compressor is tripping …first cycle it run for 10 min and then it gets trip within 4 min and again cycle goes on….the room temp is always plus 2-3 degree
@rimjhimkumari1979
@rimjhimkumari1979 11 ай бұрын
What was the problem? How did it got solved?
@greenopgirl1157
@greenopgirl1157 3 жыл бұрын
बहुत ही बढ़िया सर
@indralatasharma7752
@indralatasharma7752 3 жыл бұрын
Bahut hi achcha bataaya sir
@dreamgirlindia.97
@dreamgirlindia.97 3 жыл бұрын
Supper voice 👍
@amintechnical7462
@amintechnical7462 2 жыл бұрын
kzfaq.infoVhp07307c9Q?feature=share
@AlokShukla2891
@AlokShukla2891 2 жыл бұрын
Super hota hai... Supper nhi.... Supper nashta hota hai
@sateeshsaini2118
@sateeshsaini2118 Жыл бұрын
❤️❤️
@Jadhao389
@Jadhao389 3 жыл бұрын
Bahot badhiya bhau
@gouravparasher8271
@gouravparasher8271 2 жыл бұрын
Sir Meera window ac Lloyd ka hai raat koo kuuch deer ke liiye kabhi kabhi automatic cooling aani band ho jaati hai or phir auto chaalu kya ye common hai yaa koi problem ? Pls reply sir it's urgent I am a first user of an ac
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Kabhi kabhi bahut garmi hone ke Karan compressor overheat ho jata hai to trip ker jata hai jab compressor trip Hota hai to us samay cooling normal ho jati hai. Yr normal cause hai ager aur jada problem kare to comments kariyega
@BaljinderSingh-pn1mm
@BaljinderSingh-pn1mm 2 жыл бұрын
Thanks bhai ji for valuable information
@DiwanjionLifeSecrets
@DiwanjionLifeSecrets 3 жыл бұрын
Thank you so much for this important information
@gujjjargujjar737
@gujjjargujjar737 3 жыл бұрын
Sir please mujhe koi batado mujhe mera window ac kharab krna h new tbhi milega
@Ajaykumar-hb1md
@Ajaykumar-hb1md 3 жыл бұрын
Aag laga do shli main
@mayankboss319
@mayankboss319 3 жыл бұрын
Sir pichle 1 mahine se split AC only 5-10 minutes chalta hai phir baad mein cutoff ho jata hai.... phir 1-2 ghante bandh rakhne ke baad phir 5-10 minutes chalegaa phir cutoff ho jata Bahar Outdoor Unit par haath lagaya toh bahut zyadha garm ho raha tha .kal koi technician se AC ki service bhi kara li,Condenser bhi change karwa liya or Rely bhi change karwa li par kuch bhi nahi hua ....sir please bataiye ab kya kara jae???
@patelandbrothers
@patelandbrothers 3 жыл бұрын
Puri gass nikal ker capsliry change karwake achche se vaccume karwaker wapas fir se gass dalwaiye
@vrcvlogger
@vrcvlogger 2 жыл бұрын
हमारा स्प्लिट AC जो कि डेढ़ टन का है उसका कंप्रेशर 3 मिनट चलता है और तीन ही मिनट बन्द रहता है और अगर उसको ड्राई मोड में चलते है तो कंप्रेशर ठीक चलता है मतलब ठीक चलता है तो ठंडक भी ठीक होती है पर cool मोड 3 मिनट ही चलता है अगर ड्राई मोड में कंप्रेशर ठीक चलता है तो फिर cool मोड में दिक्क्त क्यों करता है ऐसा क्यों है जबकि बैक प्रेशर 65 है और स्टैंड प्रेशर 165 से 170 है
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Indoor unit me 2 sensor lage hote hain usame se Jo copper wala sensor Hota Hai usko check karwaiye
@sahilchamp1012
@sahilchamp1012 Ай бұрын
Bhai same condition hai 4 mint on rhta hai aur 3 mint off rhta h
@viknitu1
@viknitu1 Ай бұрын
Mera indoor ac 7 minutes chalta hai or 3 minutes band rahta hai please bataye kya issue ho sakta hai ?
@kapoorji.5539
@kapoorji.5539 8 күн бұрын
@@viknitu1 same issue. But mere me yeh tab hota jab gas low hojati.
@sahabsingh3921
@sahabsingh3921 2 жыл бұрын
Very good information sir
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Thanks bhaiya ji
@ChandraDevAgrahari
@ChandraDevAgrahari 4 жыл бұрын
Good knowledge bhaiya ji
@kajalagrawal3399
@kajalagrawal3399 3 жыл бұрын
good and very useful video
@indranilbarik5123
@indranilbarik5123 3 жыл бұрын
Bhaia excess gas tripping karta hain kya aur amp zyada hote jara phir trip hora !!! Aur bhaia r22 ka pressure kitna hota hain running pressure ??
@amintechnical7462
@amintechnical7462 2 жыл бұрын
kzfaq.infoVhp07307c9Q?feature=share
@RajnishKumar-vo6gy
@RajnishKumar-vo6gy 2 жыл бұрын
Good experience and good explanation
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Thanks bhai 🙏
@lateststepsstitching2420
@lateststepsstitching2420 3 жыл бұрын
Useful tips
@shailendrashukla6548
@shailendrashukla6548 Жыл бұрын
Very good 👍🌹
@dushantinsaan8435
@dushantinsaan8435 2 ай бұрын
Lloyd window AC purchased 2 yaers ago.kisi bhi temp pe set karne se 5-7mim chalke compressor band ho jata h bs fan chalta h.plz guide me
@patelandbrothers
@patelandbrothers 2 ай бұрын
Sabse pahle ye find out karna padega ki compressor senssor se band ho rha ya high ampare hoke tab hum kuchh bta payenge
@zahidchachakakitchen3637
@zahidchachakakitchen3637 3 жыл бұрын
Bahut badiya bataya
@432yssony
@432yssony 2 жыл бұрын
Bhai ji please suggest Karo : Mera Whirlpool split 1.5t ac trip karta hai. Actually kuch din pahle condenser change hua tha uske baad se hi ye dikkat aani shuru huyi hai. 10-15 minutes chal ker trip ho jata hai. Or ampere bhi jyada le raha hai ab. 1900watt tak bhi ja raha hai load ab. Pahle gas Kam Kari thi technician ne fir sahi chalne lga tha load bhi 1250 watt lene lga tha per cooling nahi ker rha tha. To dobara gas daali per trip ker rha hai load 1800-1900 watt le raha hai. Ac ka load actual me 1450 watt tha papers me catalogue me waise
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Gas dalne se pahle sahi se vacuume liya tha ya nahi
@amitmajumder1511
@amitmajumder1511 3 жыл бұрын
Good information 👌👌👌
@abhishekjain9503
@abhishekjain9503 2 ай бұрын
Best explained
@patelandbrothers
@patelandbrothers 2 ай бұрын
Thanks
@ApnaJandNajjar
@ApnaJandNajjar 4 жыл бұрын
Good work man 👍🔔🙏wapas
@scsaqeelengineer
@scsaqeelengineer 3 жыл бұрын
Good
@patelandbrothers
@patelandbrothers 3 жыл бұрын
thanks
@punamthakurmea
@punamthakurmea 4 жыл бұрын
30 like, very nice
@MohdZohaKhanCongressi
@MohdZohaKhanCongressi 3 жыл бұрын
Very Good Information Sir Ji
@imrannafees8289
@imrannafees8289 3 жыл бұрын
Good video Allah apko tarriqi de
@swastikindianvloggerazamga2604
@swastikindianvloggerazamga2604 4 жыл бұрын
Very helpful video 👌👍
@patelandbrothers
@patelandbrothers 4 жыл бұрын
apne dusare mobile se bhi ker diya
@vinodojha7726
@vinodojha7726 3 жыл бұрын
Thanks sir । very सुंदर 👌
@bajaurf4u703
@bajaurf4u703 4 жыл бұрын
Buhat acha 🌹Mene ap ko dust bana liya🌹
@patelandbrothers
@patelandbrothers 4 жыл бұрын
stay connected permanent
@khushirajput7764
@khushirajput7764 3 жыл бұрын
Thanku👍
@health8861
@health8861 3 жыл бұрын
Shabash bahut achha
@DeshwalPariwar
@DeshwalPariwar 4 жыл бұрын
Super knowledge
@nazranaislam7908
@nazranaislam7908 2 жыл бұрын
Mera window ac h line toh thk h par ac chalta h phr slow ho jaata h phr se chalta h phr compressor slow ho jaata h ..earthin ka prblm bhi ho sakta h kya..kyun k jahan se earthin liya h woh line me bohat load h
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Haa ager voltage 190 volt se kam ho jata hoga to bhi aisi problem aati hai, night me jada problem hoti hai kya
@nazranaislam7908
@nazranaislam7908 2 жыл бұрын
@@patelandbrothers din me hota h ..neutral kya hota h sir
@patelandbrothers
@patelandbrothers 2 жыл бұрын
@@nazranaislam7908 aap ac chalu rahte hi voltage check karwaiye
@DeshwalPariwar
@DeshwalPariwar 4 жыл бұрын
3 like
@daikinpvtltd2499
@daikinpvtltd2499 3 жыл бұрын
good information 👌
@shaktisuccess0369
@shaktisuccess0369 3 жыл бұрын
Sir, humara lg ka ac hain usme outdoor unit jab band hota hain to jor se khattt.. esi awAz ati he , to kya problem ho sakta hain? Plz bataiye
@patelandbrothers
@patelandbrothers 3 жыл бұрын
compressor 3 nut bolt se bandha hota hai un nut bolt me rubber ke gromet pade hote hai kahi wo gromet kat to nahi gaye
@rishikeshmenon2380
@rishikeshmenon2380 3 жыл бұрын
thank u very much. you r sooper.
@mohammadasifkhan4188
@mohammadasifkhan4188 Жыл бұрын
Same pro ho rhi h sir 15 mnt chalta h compressor heat hokr band ho jara h capacitor chenj kr diya condenser bhi bhut ganda tha clean kr diya gas bhi shi h voltage bhi shi h fir bhi trip ho rha h fan moter chenj krna pdega kya 😊
@patelandbrothers
@patelandbrothers Жыл бұрын
Fan motor na change kariye fan ka jo capacitor hai usako change kariye fir bhi nahi hota hai to btaiyega
@ShanuKhan-bu9qn
@ShanuKhan-bu9qn 3 жыл бұрын
Thanks sir. Good
@baljitsingh-fe7jz
@baljitsingh-fe7jz 3 жыл бұрын
Good very nice knowledge
@suganyasimplelifestyle6021
@suganyasimplelifestyle6021 4 жыл бұрын
Nice I am your new friend please stay connected
@insepectordaya9973
@insepectordaya9973 3 жыл бұрын
You Are Gujrati?
@patelandbrothers
@patelandbrothers 3 жыл бұрын
no im am from lucknow Uttar Pradesh
@Motivate111
@Motivate111 2 жыл бұрын
Sir mene lloyd ka ac new liya ha 1.5 ton inverter.. me 28 pe chalata hu to 5 10 min cooling krne ka baad compressor off ho hata ha normal hai ya koi problm ha sir ..?
@patelandbrothers
@patelandbrothers 2 жыл бұрын
jab room ka temperature badhta hai to fir compressor chalu ho jata hoga waise koi problem aapki ac me nahi hai fir bhi aap neeche link per jaker video dekhiye poora process samajh jayenge, kzfaq.info/get/bejne/gq-Tqah_1ZfWqIU.html
@Motivate111
@Motivate111 2 жыл бұрын
@@patelandbrothers sir ek or problem ha ac me .. chill mode pe itna cooling nahi krta jitna dry mode pe krta ha dry mode pe bht jyada colling krta ha
@nitin4322
@nitin4322 2 жыл бұрын
Hello sir. Mene 1.5 ton 3 star window ac liya h 1 month phle. Me use 24 pe chalata hu wo starting me max. 10 compressor on rrhega uske bad band ho jata h fir 5 min bad on hota h bs fan chalta h or fir 1 min bad compressor bnd ho jata h . Yahi continue rheta h raat bhar.or na room itna cool hota h bs samne baithe rhne walo ko thanda lgata h wo bhi jb compressor on hota h. Or iski left side bhi cool rheti h. Please suggest me kya problem hogi
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Aap apne yha voltage check karwaiye jab compressor chalta hai to voltage dropping to nahi ho rahi hai
@userRampur2022
@userRampur2022 3 жыл бұрын
सर कंप्रेसर चल रहा है starting mein 25 A ले रहा है तीन से चार सेकेंड चलता है फिर बंद हो जाता है फिर चलता है फिर 3-4 सेकंड चलता है फिर ट्रिप हो जाता है क्या समस्या है
@patelandbrothers
@patelandbrothers 3 жыл бұрын
bhai Running capacitor change karke chalu kariye
@dharam8033
@dharam8033 3 жыл бұрын
Thank You 🙏
@rupag1849
@rupag1849 3 жыл бұрын
Sir mera o carrier 1.5 ton ac, Once ac on kare after 10 mini AC automatically totally off then automatically on whats is the problem sir plz bathaye
@nkelectricianhr7664
@nkelectricianhr7664 3 жыл бұрын
Ho jayega sahi
@kingofnawab3603
@kingofnawab3603 2 жыл бұрын
Sir app se ekk questions hai mujhe batao ki gass charges me kon line khan use hoga sir please tell me sir please me isme bahot jda confused hun sir please
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Gas charging hamesha low side se karte hain Matlab aapko gas charging ke samay suction line me charging line ko lgana hai ya fir aap aur kuchh confuse hain to poora question likhe
@kingofnawab3603
@kingofnawab3603 2 жыл бұрын
Sir me appse ye puch rha hun ki har gash alag alag hota hai to gaisline jo hoti hai wo alag alag lagti haina to wahi me puch rha hun ki kon se gash me kon line lagega sir
@gurdialswalia8308
@gurdialswalia8308 3 жыл бұрын
Very nice suggestion
@AjaySingh-rg8yi
@AjaySingh-rg8yi 3 жыл бұрын
bhai aap bhut gret ho
@desifoodwithfatima5200
@desifoodwithfatima5200 4 жыл бұрын
Great information thanks for sharing 👌👌👌
@amintechnical7462
@amintechnical7462 2 жыл бұрын
kzfaq.infoVhp07307c9Q?feature=share
@Abcdgjiftijgduoo
@Abcdgjiftijgduoo 3 жыл бұрын
Very nice video
@niyasniyasdeen6586
@niyasniyasdeen6586 3 жыл бұрын
Nice keep it up
@manishsingh4742
@manishsingh4742 Жыл бұрын
Sir Agar PCB nor working properly to bhi compressor trip hoga kya ..same problem 5 minut nice cool but then compressor trip and normal air flow...ols suggest
@patelandbrothers
@patelandbrothers Жыл бұрын
Sabse pahle aapko ye find out karna hoga ki compressor heat hoker band ho rha hai ya aise hi, 5 minute me trip ke baad kitni der me start hota reply
@Adggg.
@Adggg. 5 ай бұрын
@@patelandbrothers अगर ट्रिपिंग के बाद खुद से ऑन नहीं होता है और अगर फिर मैं ऑन करता हूं तो ऑन हो जाता है लेकिन फिर ट्रिप कर जाता है तो क्या करना चाहिए?
@akberkhan3071
@akberkhan3071 3 жыл бұрын
Sir ..Compressor me oil ki matra km hogi tb bhi compressor over hit ya trip hoga
@rajtechnicaltech8046
@rajtechnicaltech8046 3 жыл бұрын
Han
@Rudrash-u3
@Rudrash-u3 Ай бұрын
Oil ke karn band huaa kes peta chelta hai
@Foodportalareeb
@Foodportalareeb 3 жыл бұрын
Daikin has the worst air conditioner ever...i recommend all of you to don't buy daikin even for free..they are charging 4130 for gas filling... it's worst.. worst after sale service.. they took 6 days just to visit my home
@amitchaudhary3985
@amitchaudhary3985 3 жыл бұрын
Sir mere pas 1.5 ton window ac. H. Ac 6 min tk shi chlegi uske bad 3 min k liye trip ho jayegi. Kya problem h bhai ji. Please btaye
@patelandbrothers
@patelandbrothers 3 жыл бұрын
grill kholker dekhiye coil me senssor laga hoga us senssor ko coil se hataker hanth me pakadker rakhiye phir ac chalaiye aur dekhiye kitani der chalta hai
@RahulSharma-qj5wq
@RahulSharma-qj5wq 2 ай бұрын
Hello, LG non inverter split 1.5 AC, compressor trip problem, 5 min chalta hain uske baad band ho jata hain, no cooling only fan running, service karwa li, capacitor change karwa liya, kya problem ho sakti hain, pls guide, outdoor unit chanv main hain
@hajiamirsajjad1978
@hajiamirsajjad1978 2 ай бұрын
De.
@patelandbrothers
@patelandbrothers 2 ай бұрын
Jab 5 minute chalta hai toh cooling hoti hai aur ampare metre lga ke check kariye jab band hone wala hota hai toh us time ampare kitna hota hao
@user-cg9vl3er9i
@user-cg9vl3er9i Жыл бұрын
Sir dubbal door fridge ka kam cooling me kya kya problem ho sakti hai pleas ek video banaye
@sayyedshavezali3466
@sayyedshavezali3466 3 жыл бұрын
Very nice 👍👍👌👍👍 bro
@shivanis9
@shivanis9 2 жыл бұрын
Hitachi 1.5ton window ac h Abhi new he liya h Compressor thode der chalne ke bad drip kr jata h autimatically phir khud strt ho jata h jo window ac mei comtrol panel hota h waha jo light hoti h commpressor.ki off ho jati h Or mujhe aisa lgta h ki ac chalate time usmei ek ajeeb smell aati h Ac zada use nai krte?? Comperssor chalta h tab achi cooling phir h but automically band hojata h phir fan chalta h bus Window ac forth floor sun facing side pe.laga h Kabhi kabhi night mei bhi drip hota j
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Ager Control panel me compressor Wali light off hoker compressor band ho rha hai to iska Matlab Control panel se sensor room cool ho gya aisa command de rha hai jab room ka temperature badhega to compressor fir se automatically start ho jayega, waise Aap kitane temperature per set karke ac chla rahe hain
@hafizmuhammadusmanitfaqqad3690
@hafizmuhammadusmanitfaqqad3690 3 жыл бұрын
Mera ac haire ka ha 18000 btu vo sirf 30 secnd chalta ha or us ka compreser band ho jata ha ma nay us ka raning copester bhi chanj kiya magar vo phir bhi 7 empaer lay kar band ho jata ha us ka kiay fold ha????????? Plz reply
@patelandbrothers
@patelandbrothers 3 жыл бұрын
jab ompressor band hota hai to fan cbala karta hai ya wo bhi band bo jata hai
@jitenderofficial7711
@jitenderofficial7711 3 жыл бұрын
Very Good
@hvacsolutions1632
@hvacsolutions1632 3 жыл бұрын
Very nice explanation
@muhammadjafer
@muhammadjafer Жыл бұрын
Sir I hve 1 split 1.5t ac Its work f9 in night and taking mor amp asss compair normal. But in day its trip aftr 20mnts What problm in my ac?
@patelandbrothers
@patelandbrothers Жыл бұрын
Direct sunlight on the outdoor unit reads that if this happens, the discharge pressure of outdoor increases due to direct sunlight, the compressor gets heat due to increase in discharge pressure,this is normal case
@Agri_Changer
@Agri_Changer Жыл бұрын
Sir i am learners, muje apke pass se training leni he . Aap kaha se ho. Ya fir online sikhate ho
@patelandbrothers
@patelandbrothers Жыл бұрын
Aap kaha se hain, mai lucknow se hun
@SantRam-xo2yu
@SantRam-xo2yu Жыл бұрын
भाई कोई भी मेकैनिक इतनी चैकिंग नहीं करता । सीधा सीधा गैस चार्ज करता अगर परावलम फिर रहे फिर कुछ और फिर और चलता रहता है । हमारे ऐसी किसी दिन परावलम देता है और किसी दिन पूरी रात नान स्टाप बिलकुल सही रहता है ।
@Shariq26
@Shariq26 2 жыл бұрын
45 micro Farad ac me install tha mechanic 50micro Farad laga diya hai... uske baad se outdoor bht awaaz kr raha or sahi se chal bhi nahi raha and outdoor trip bhi ho raha h... koi solution de
@patelandbrothers
@patelandbrothers 2 жыл бұрын
45 mfd ki jagah 50 mfd lga diya isase koi fark nahi padta, aap voltage check karwaiye, aur ye btaiye ki aapka ac Kitna purana hai
@JunaidKhan-ik5yw
@JunaidKhan-ik5yw 2 жыл бұрын
Sir mera haier ka 1.5ton window ac h yei cooling to krta h but kbhi kbhi cut ho jata h compressor jhatke sei aur fir ac band krke backside paani dalke ac cooling achi krta h isme kya problem h iski service krva kei sahi hojaega ya koi aur issue h
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Service karwa lijiyega aur voltage check karwaye ki kam jada hota hai kya
@syedabbasali3673
@syedabbasali3673 2 жыл бұрын
Ek jankari Den please old model dedh tan ka window AC hai Lancer ka kya uska compresser Badal sakta hai
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Haa reciprocating compressor lga dijiye
@AbhishekTiwari-rq3sp
@AbhishekTiwari-rq3sp 2 жыл бұрын
Sir mera 1.5 ton ka haier ka window ac hai 8 years old 15 min chalne ke baad ampere bahut jada badh jaa rha hai aur 10 kilowatt ka stabilizer trip ho ja rha hai jo kj mere ghar ka pura load 5 kilowatt hi hai
@patelandbrothers
@patelandbrothers 2 жыл бұрын
Ac service Kab se nahi karai
@m.r.mullick149
@m.r.mullick149 3 жыл бұрын
👍👍 akdam 👍👍
@rohitjaiswal0339
@rohitjaiswal0339 3 жыл бұрын
Nice Vedio sir ji
@shreyasdharmadhikari3505
@shreyasdharmadhikari3505 3 жыл бұрын
Hi sir, I have carrier ac austra model(1 ton ). My ac showing error E1. Called customer care they changed outdoor pcb (was working fine hence complaint closed). But after 1 week same problem is occurring. Please guide.
@patelandbrothers
@patelandbrothers 3 жыл бұрын
waise e1 is comunication error in out door pcb, you call costumer care again and claim him
@VijaySingh-fb6uf
@VijaySingh-fb6uf Жыл бұрын
Indoor to outdoor coppr pipe conection ager 3 feet ya esse kam ho to koyi dikkat hota hai kya
@patelandbrothers
@patelandbrothers Жыл бұрын
Haa discharge pressure badhane lagta hai, jisase ac thodi der chal chal ke band chalu hota hai,
@tapasdas8732
@tapasdas8732 3 жыл бұрын
ekdomi sach bat thanks sir
@jeyvinaysbucoy3438
@jeyvinaysbucoy3438 3 жыл бұрын
Hello friend I'm sending support
@patelandbrothers
@patelandbrothers 3 жыл бұрын
done
@anjummumtaz6225
@anjummumtaz6225 3 жыл бұрын
Right sir capillary problem hai
Gli occhiali da sole non mi hanno coperto! 😎
00:13
Senza Limiti
Рет қаралды 6 МЛН
Magic trick 🪄😁
00:13
Andrey Grechka
Рет қаралды 37 МЛН
DIY Vapor Compression Refrigeration System
28:06
Hyperspace Pirate
Рет қаралды 1,1 МЛН
Gli occhiali da sole non mi hanno coperto! 😎
00:13
Senza Limiti
Рет қаралды 6 МЛН