COP of Chiller Plant

  Рет қаралды 5,951

Building Sanchalan

Building Sanchalan

9 ай бұрын

Dear Viewers,
Here I described how to calculate COP of chiller plant in utility.
Building Sanchalan

Пікірлер: 85
@ashwanikumarrajput1926
@ashwanikumarrajput1926 3 ай бұрын
Sir very good job Regards Ashwani Kumar
@BuildingSanchalan
@BuildingSanchalan 3 ай бұрын
tx
@NaeemKhan-gb3ez
@NaeemKhan-gb3ez 28 күн бұрын
Sir I appreciate your efforts.salute you you're the great.❤❤
@BuildingSanchalan
@BuildingSanchalan 27 күн бұрын
So nice of you
@Muzamilkhan-pf4if
@Muzamilkhan-pf4if 4 ай бұрын
Good work sir g
@BuildingSanchalan
@BuildingSanchalan 3 ай бұрын
Thanks
@RohitSharma-ye7wn
@RohitSharma-ye7wn 5 ай бұрын
Nice topic sir ❤🎉
@BuildingSanchalan
@BuildingSanchalan 5 ай бұрын
Thanks for liking
@rajendrarawat5230
@rajendrarawat5230 2 ай бұрын
🎉🎉🎉
@srinivas9391
@srinivas9391 3 ай бұрын
Thank you sir for your information 🙏
@BuildingSanchalan
@BuildingSanchalan 3 ай бұрын
So nice of you
@ekbalshekh2600
@ekbalshekh2600 5 ай бұрын
Nice sir
@BuildingSanchalan
@BuildingSanchalan 5 ай бұрын
Thanks and welcome
@rahulpalmzp4606
@rahulpalmzp4606 5 ай бұрын
Aap sahi se samjhate hai sir ji
@BuildingSanchalan
@BuildingSanchalan 5 ай бұрын
thanks
@madhukarpujari1481
@madhukarpujari1481 6 ай бұрын
Very nice dir
@BuildingSanchalan
@BuildingSanchalan 6 ай бұрын
Thanks a lot
@arun4846
@arun4846 5 ай бұрын
Thanks sir ❤❤❤
@BuildingSanchalan
@BuildingSanchalan 4 ай бұрын
welcome
@ravindrakumaryadav8521
@ravindrakumaryadav8521 3 ай бұрын
@BuildingSanchalan
@BuildingSanchalan 3 ай бұрын
welcome
@hengineeringmind1647
@hengineeringmind1647 9 ай бұрын
THANKU Sir Aap. Interview ke Related jitna Bhi Video Banaye hai Sab dekha hu Sab ka samajh me aa jata hai but Plumber or STP operator ka video samajh me nahi aata hai pata nahi kiyo Me Soch Raha hu Aapk Jis Side PE job kr rahe hai me Waha 6 month job Karu taki sab kuchh Sikh lu
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
dobara dekho aur jo samajh me na aaye usko practically dekh kar try karo ya mail karo.
@mrfaizu637
@mrfaizu637 2 ай бұрын
Sir but kaise naapte hai is par bhi video banaye
@vipinjoshi1628
@vipinjoshi1628 9 ай бұрын
Sir mainly we didnt have btw meter so pls explain it with defination and also ikw of chiller. And min and max value of cop and ikw of chiller. And also i m always confused in sanction and demand load of building. Pls explain. Hope you will explain this too.
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
IKW and cop are same. sanction load is contract load, demand according to our connected load and maximum demand.
@shanimishralokdhun
@shanimishralokdhun 9 ай бұрын
सर एस टी पी के बारे में आपके जैसा जानकारी पाने के लिए कौन सा कोर्स करना पड़ेगा प्लीज जवाब जरूर दीजिएगा
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
Dost koi course ni ha alag se practice and learn.
@shanimishralokdhun
@shanimishralokdhun 9 ай бұрын
@@BuildingSanchalan aap se mil sakta hai
@deepakthakur-gn1dv
@deepakthakur-gn1dv 17 күн бұрын
Which electrical load do i calculate only chiller or all accessories like secondary, primary, condenser pump and ct fan motors
@BuildingSanchalan
@BuildingSanchalan 16 күн бұрын
only chillar plant
@thesaurabhgaur
@thesaurabhgaur 9 ай бұрын
Sir - Kindly brief about IKW of chiller
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
Main performance parameter is ikW/TR and it is define by ratio of power input to compressor divided by tons of cooling produced. Lower ikW/TR indicates higher efficiency. COP and IKW are same thing.
@DeTech27
@DeTech27 3 ай бұрын
Sir ct ke water(tds/PH etc) ke baare me to video bnaya hai aapne but chiller water(tds/pH etc) ke baare me bhi ek video upload kariye sir please 🙏🙏🙏🙏🙏
@BuildingSanchalan
@BuildingSanchalan 3 ай бұрын
Chiller water me soft water use kiya jaata ha jo soft water ke parameter ha wahi rahenge.
@DeTech27
@DeTech27 3 ай бұрын
@@BuildingSanchalan thank you sir🙏🙏🙏
@nikhildimble6368
@nikhildimble6368 Ай бұрын
BTU /hr ye btu meter me kaise milega yani muje btu meter per 2.241kwh dikhata he to btu/ hr kitna
@DilshadKhan-xq1bo
@DilshadKhan-xq1bo 7 ай бұрын
SOP ke bare me bataye sir fm me
@NaeemKhan-gb3ez
@NaeemKhan-gb3ez 28 күн бұрын
Bro please tell me the electricity consumed by the chiller including all the primary, secondary pumps and condenser pumps?
@BuildingSanchalan
@BuildingSanchalan 27 күн бұрын
It will depend on plant capacity.
@rgsonugamer4407
@rgsonugamer4407 9 ай бұрын
सर hvac टेकनीशन विदेश का इंटरव्यू में क्या क्या qustion किया जाता है इनपोटेन क्यूशन में वीडियो बनाए plz सिर।।।।।
@user-lv5rx7do7f
@user-lv5rx7do7f 9 ай бұрын
विदेश में क्या रखा है भाई
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
kzfaq.info/get/bejne/sLp1fcZj3bbNYIU.htmlsi=bEfuB430J8gmK54F watch it, everywhere technical interview questions are same.
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
The Whole world is ours.
@Afzalkhan-jj7uc
@Afzalkhan-jj7uc 9 ай бұрын
Sir btu meter se every ahu k pass jayenge btu check krne k liye
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
Jab chillar plant per na ho tab.
@jayshankarkeshri2709
@jayshankarkeshri2709 8 ай бұрын
What is the approach temperature and why it's going high..?
@BuildingSanchalan
@BuildingSanchalan 8 ай бұрын
kzfaq.info/get/bejne/Z8hodtt3ysDbdn0.htmlsi=qysOl5A9DM7M8ZAY watch it
@vijaysharma3560
@vijaysharma3560 8 ай бұрын
Sir what is range of cop for good chiller plant
@BuildingSanchalan
@BuildingSanchalan 8 ай бұрын
40% to 60%
@ervikasrao4807
@ervikasrao4807 6 ай бұрын
Dear Sir, what is the formula to calculate the CAM bill of a Building?
@BuildingSanchalan
@BuildingSanchalan 6 ай бұрын
there is not a specific formula. It depend on building's type. watch it, you will find answer. kzfaq.info/get/bejne/oatylNR-2c-6aYE.htmlsi=QfJv57Y4OBjjQlI1
@jaishankerchaurasiya5730
@jaishankerchaurasiya5730 9 ай бұрын
Sir Good Evening, Mere Pass one question hai is topic se alag hai , hamare pass HVAC plant ek 30 kw ke condenser motor hai uska panel side se , star delta ka 6 wire jo panel pe hai , wah hamesha heat hota , continously Burn hota hai , Hamane sare option try kiya Jaise 1- motor current each phase ok as rated current Pls. App kuch suggestion dijiye hai. Ki problem ko permanent resolve kar sake. Regards Jai
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
please check wire size once and tight all connection in every week. Wire/ cable should be copper then problem must be resolve.
@satendrajaat657
@satendrajaat657 8 ай бұрын
Vantilation problem ho sakta h
@ganeshadari4244
@ganeshadari4244 9 ай бұрын
Is cop and ikw is same
@BuildingSanchalan
@BuildingSanchalan 8 ай бұрын
yes
@funnyAnimatedVideos
@funnyAnimatedVideos 8 ай бұрын
Hi sir what are the design parameters of cop, i meant how we understand that our cop is good or not.
@BuildingSanchalan
@BuildingSanchalan 8 ай бұрын
For water cooled chiller the minumum COP is 4.2
@hardikjoshi7224
@hardikjoshi7224 8 ай бұрын
Cooling tower evaporation loss and blow down losses and drift loss kaise Nihal Sauter hain?
@BuildingSanchalan
@BuildingSanchalan 8 ай бұрын
kzfaq.info/get/bejne/nJqAktinrJizlH0.htmlsi=mZj-5SSt1OP9SSH- many more video related to blow down etc in chanel please visit Building Sanchalan
@Comedyking94128
@Comedyking94128 17 күн бұрын
Sir plant ki kitni Cop best rahti h
@BuildingSanchalan
@BuildingSanchalan 16 күн бұрын
4 to 6
@mainpalsingh2744
@mainpalsingh2744 5 ай бұрын
Sir agar BTU meter na Lage ho to kaise nikalte cop ko please reply
@BuildingSanchalan
@BuildingSanchalan 5 ай бұрын
Isi tarike se nikalte ha
@deepaktyagi3731
@deepaktyagi3731 9 ай бұрын
Sir chiller ki COP ko impact karne Wale reason ya parameters kon kon se ho sakte hai?
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
Poor maintenance of condensor, cooling tower, poor quality water, damage mechenical iterms etc.
@sandeepverma6691
@sandeepverma6691 8 ай бұрын
What should be the limit of COP of chiller
@BuildingSanchalan
@BuildingSanchalan 8 ай бұрын
It depends on the plant condition and maintenence. Limit is 40% to 60%
@sandeepverma6691
@sandeepverma6691 7 ай бұрын
Thanks Sir
@sharmajielectrical9853
@sharmajielectrical9853 2 ай бұрын
Sir दो chiller unit hai 120 120 TR ke दोनो pr लोड 70 परसेंट से कम है but discharge discharge pressure 150, 152 जा रहा है और कूलिंग टावर से पानी 34, 36 डिग्री a rha hai दोनो CT fan चालू होने के बावजूद प्रोब्लम का सॉल्यूशन कया है सर
@BuildingSanchalan
@BuildingSanchalan Ай бұрын
Dirty condensor, You need de scaling of both condensor.
@pankajkumar-oh3ct
@pankajkumar-oh3ct 9 ай бұрын
Sir,ikw kya hota hai
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
COP ko hi IKW/KWR bhi kahte ha, same ha
@maninderthakur1992
@maninderthakur1992 9 ай бұрын
Yes sir IKW pr ek details mai video share krne please
@pankajkumar-oh3ct
@pankajkumar-oh3ct 9 ай бұрын
@@BuildingSanchalan sir, ikw-cop ka sayad ulta nahi hota kya?,kyuki cop ki value jitni badi hogi utni acchi hogi aur ikw ki value jitni choti hogi utni achhi hogi,pls correct me if it is not..
@DilshadKhan-xq1bo
@DilshadKhan-xq1bo 7 ай бұрын
Cop= 5.86 Good Kitna hona chahiye
@BuildingSanchalan
@BuildingSanchalan 7 ай бұрын
Min-4 to Max 5.5
@pankajkumar-oh3ct
@pankajkumar-oh3ct 9 ай бұрын
Sir Dief controller ke baarei mein bhi bataiyee, interview mein kaii baar poocha gaya hai, jawab nahi de paaya hu, pls help me😢😢.. kei comments kiye hai,pls make it for God sake...
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
OK pankaj. I will try but it will take time.
@pankajkumar-oh3ct
@pankajkumar-oh3ct 9 ай бұрын
@@BuildingSanchalan thanks sir waiting for your video
@hengineeringmind1647
@hengineeringmind1647 9 ай бұрын
Aapke under Bahut Nolage hai
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
Esa ni ha ji. sab yahan hi seekhte ha.
@vinaykumar4920
@vinaykumar4920 9 ай бұрын
🎉🎉🎉
@BuildingSanchalan
@BuildingSanchalan 9 ай бұрын
Thanks
SUPERHEAT IN HVAC
21:22
Building Sanchalan
Рет қаралды 6 М.
ОБЯЗАТЕЛЬНО СОВЕРШАЙТЕ ДОБРО!❤❤❤
00:45
Nastya and SeanDoesMagic
00:16
Nastya
Рет қаралды 38 МЛН
Safety Setting in Chiller Plant
16:57
Building Sanchalan
Рет қаралды 58 М.
SBR in STP
22:44
Building Sanchalan
Рет қаралды 18 М.
COP and KW per Ton
6:21
VRF Wizard
Рет қаралды 35 М.
Common Area Maintenence
19:40
Building Sanchalan
Рет қаралды 1,5 М.
COOLING TOWER CHEMICAL
13:14
Building Sanchalan
Рет қаралды 44 М.
ОБЯЗАТЕЛЬНО СОВЕРШАЙТЕ ДОБРО!❤❤❤
00:45