DC mA measurements with the HT4006 Clamp Adapter

  Рет қаралды 222

Three-phase

Three-phase

Күн бұрын

Testing out the capability of the HT4006 Current Clamp Adapter from HT Italia to read DC current between 100mA and 1000mA.
Utilising the HT Neptune, U1282A and MetraHit Coil instruments with the adapter.
HT Italia HT4006
www.ht-instruments.com/en/acc...
Also available as the Extech C250
www.extech-online.com/index.p...
Previous video on HT4006
• HT Instruments HT4006 ...
0:00 Introduction
0:34 Test Setup
2:28 Current Measurements
7:12 Test Results
10:26 Neptune Zero Setting

Пікірлер: 4
@JAKOB1977
@JAKOB1977 5 ай бұрын
How many tools do you have with inrush? Could be interresting to see how these AC intended inrush features actually performs in DC, what accuracy they deliver and what timeframe the current burst needs to be present to deliver that given tolerance.. thx for the vid.
@three-phase562
@three-phase562 5 ай бұрын
I think I have 5 or 6 meters with inrush current measurement. Some are AC only though along with some protection relays I have, that have disturbance analysers built in. Not sure how they would respond to measuring DC inrush. It would take a little bit of setting up with the SMRT but should be possible. Something else to add to the list.
@JAKOB1977
@JAKOB1977 5 ай бұрын
@@three-phase562 The only item I got with inrush current ability is the HT208D clamp meter. It's the same as your Kaiweets HT208D, this Habotest HT208D is just a cheaper 40 dollar revision without the silicone probes but otherwise identical. Been testing it with a few DC spotwelders but I lack the reference tools to put the accuracy into perspective. It does look linear and the values are consistent even from a few ms. Most clamp meter seems only spec'ed for AC..as far as I can tell it is the more expensive models like fx Fluke 345 that also mention DC tolerances on is inrush feature, so curious how well AC labeled inrush meters work on DC current spikes. Been looking on YT for vids handling this inrush aspect, but sofar no dice.
@three-phase562
@three-phase562 5 ай бұрын
@@JAKOB1977 If it is an RMS clamp, then it should pick up a DC current that is rising. Once settled it will rely on the hall effect sensor to measure DC current. For DC a good oscilloscope could be used to act as a comparison.
Megger SMRT 1 Current Inrush Model
16:02
Three-phase
Рет қаралды 186
How to use a multimeter like a pro, the ultimate guide
12:55
James Gatlin
Рет қаралды 1,7 МЛН
Vivaan  Tanya once again pranked Papa 🤣😇🤣
00:10
seema lamba
Рет қаралды 34 МЛН
HOW DID HE WIN? 😱
00:33
Topper Guild
Рет қаралды 41 МЛН
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 54 МЛН
Current Clamp Inrush Current Testing Part 2
14:16
Three-phase
Рет қаралды 234
Brymen BM869s vs Fluke
22:02
joe smith
Рет қаралды 107 М.
The most useful tool ever for electronics repairs - (PWJ212)
13:09
Play with Junk
Рет қаралды 251 М.
Horrific LED tester that can literally kill you - (with scary schematic)
15:48
Current Clamp Inrush Current Testing Part 1
20:43
Three-phase
Рет қаралды 427
UNI-T UT210E Unboxing and review!
15:40
Simple Electronics
Рет қаралды 112 М.
Testing the MetraHit IM Xtra Coil Function
14:16
Three-phase
Рет қаралды 309
Reviewing the Fluke 376fc & 378fc
10:40
lexi abreu
Рет қаралды 32 М.
You're Using a Torque Wrench Wrong: MythBusting 10 Do's & Dont's
20:25
Torque Test Channel
Рет қаралды 530 М.
Я УКРАЛ ТЕЛЕФОН В МИЛАНЕ
9:18
Игорь Линк
Рет қаралды 84 М.
Klavye İle Trafik Işığını Yönetmek #shorts
0:18
Osman Kabadayı
Рет қаралды 1,6 МЛН
Опыт использования Мини ПК от TECNO
1:00
Андронет
Рет қаралды 772 М.
Урна с айфонами!
0:30
По ту сторону Гугла
Рет қаралды 8 МЛН
Как правильно выключать звук на телефоне?
0:17
Люди.Идеи, общественная организация
Рет қаралды 809 М.