Don't Confuse TD & Delta T

  Рет қаралды 33,817

HVAC School

HVAC School

3 жыл бұрын

Don't Confuse TD & Delta T! We cover what TD and delta T are in HVAC/R language as well as why they get confused and how to use the terms productively.
Read all the tech tips, take the quizzes
and find our handy calculators at www.hvacrschoo...

Пікірлер: 45
@grashoprsmith
@grashoprsmith 3 жыл бұрын
It videos like this that would have been so helpful as a beginning tech. Parsing through what various old timers called things was always challenging. The current and next generation techs will benefit greatly. Thank you
@HughesManHVAC
@HughesManHVAC 3 жыл бұрын
22 years in this field and I gain knowledge from every video you make. Still learning! Thanks
@Foche_T._Schitt
@Foche_T._Schitt 3 жыл бұрын
I once confused TD with STD. Boy was I relieved after seeing my doctor.
@maness2112
@maness2112 3 жыл бұрын
Std come from chy-na.
@Foche_T._Schitt
@Foche_T._Schitt 3 жыл бұрын
@@maness2112 coof coof
@emailfilters
@emailfilters 2 жыл бұрын
I just started HVAC/R school last January and I stopped confusing these terms when I was told to think of TD as (T)wo (D)ifferent media temperatures (one being the temperature of the air and the other being the temperature of the boiling refrigerant!) ΔT just fell into place after that distinction (the difference in the temperature of the same meda at different points in the system).
@setaraujo1478
@setaraujo1478 3 жыл бұрын
I always thought TD meant TouchDown 🏈 and Delta Tea was was a fancy refrigerant. I stand corrected. Thanks for your wisdom Brian! 😅
@michaelcostello6991
@michaelcostello6991 3 жыл бұрын
Great explanation again. No one can hold a newbie airconditioning tech back with content like this in the web. Thank you.
@bikerbobcat
@bikerbobcat 3 жыл бұрын
Every day I learn something new here and will hopefully be a little better tech than yesterday. I always just use Delta T but never thought to take TD.
@soleilsoleil8287
@soleilsoleil8287 Жыл бұрын
Awesome Sharp explanation😊
@leomoreira28
@leomoreira28 3 жыл бұрын
Evaporator temperature is called apparatus dew point. Never ever heard of TD before.
@Brandon-bl8ko
@Brandon-bl8ko 3 жыл бұрын
Good to know. Never knew to even take TD. I always just used delta T
@ts51
@ts51 Жыл бұрын
Well done Bryan. Thanks!
@justinnegrete6803
@justinnegrete6803 3 жыл бұрын
I always learn something I didn't know with your videos i always thought they where the same
@waltw8230
@waltw8230 3 жыл бұрын
Never knew that, always thought it meant the same now i know thanks
@ronc8489
@ronc8489 3 жыл бұрын
Thanks for the explanation, I needed that.
@abazism
@abazism 4 ай бұрын
Wow i away thought that it was the same for 25 years. Looooool.
@bugalaman
@bugalaman 2 жыл бұрын
To make things even more confusing, Td in meteorology typically means dewpoint temperature. ΔT does mean temperature difference since Δ typically means difference in scientific formulas.
@donnierobertson3088
@donnierobertson3088 3 жыл бұрын
Nice job and video like always
@nickdaggitt5079
@nickdaggitt5079 Жыл бұрын
Ive never used td to describe saturation temp from air temp.
@tmacgee1234
@tmacgee1234 3 жыл бұрын
I wish every tech would watch this lol
@rafyferrer1191
@rafyferrer1191 2 жыл бұрын
Is there an hvac company to work for in the area of saint Petersburg florida that is as thorough and cares about the customer and there employees and the desire to do things the right way as you care and teach others? Could be a long shot but maybe at least something close to it.
@joaocruz1979
@joaocruz1979 3 жыл бұрын
great video
@abelurrutia1192
@abelurrutia1192 3 жыл бұрын
You got you.
@Mapdotgolf
@Mapdotgolf 2 жыл бұрын
So basically if someone keeps at 68. And it’s not that hot outside, unit can freeze up alot?
@thanpan1276
@thanpan1276 2 жыл бұрын
AMAZING TIP FROM TY BRANAMAN TO HERE. THANK YOU.
@mrgreen9086
@mrgreen9086 3 жыл бұрын
I've always thought that TD was for refrigeration applications only and Delta T was for comfort cooling.
@REFRITEKREFRIGERACION
@REFRITEKREFRIGERACION 3 жыл бұрын
Mr Green HVAC Yes I used to think the same before because AC technicians on the field pay more attention to delta T and refrigeration tech focus more on the TD.
@haroldcruz2143
@haroldcruz2143 3 жыл бұрын
I love your videos .I'm a student at the pbsc and you have pulled me through many difficult concepts to understand. Thank you very but very much. Oh would you take a little observation. Can you speak just a bit slower. This material is sometimes too hard understand and also the amount of examples when explaining something kind of divert the point you are trying to implie.
@MinnesotaHvAc
@MinnesotaHvAc 3 жыл бұрын
Just to clarify your saying saturation temperature - S.A.D.B.=DELTA T, R.A.D.B. -S.A.D.B.=TD?
@MinnesotaHvAc
@MinnesotaHvAc 3 жыл бұрын
Apologies if my abbreviations are hard to understand. Those of us at my shop don't explain them. We have determined if your only in it for a check call another master or advanced because we are busy cleaning up and working late.
@shieldcracker
@shieldcracker 10 ай бұрын
DeltaT = LAT -EAT = SAT - RAT TD= RAT - Te = RAT - SST All temps sre dry bulb.
@chriswiles874
@chriswiles874 3 жыл бұрын
Nice 🙂👍
@MinnesotaHvAc
@MinnesotaHvAc 3 жыл бұрын
So as a backward scientist. Add and this subject matter is my game. Delta w.b. plus delta D.B. AXAMPLE equals 30. 12000 ÷30=400. After some 1000 commission's this is what I've observed. So my question to whom I most respect. What do you think. I work at a shop of 200 tech's. I'm sure I've been the only one that received a complaint of to cold. So I up air flow from 350 cfm to 425 cfm. Nice lady let me prove my jargon. Ambient 95 rh 80. Indoor 76db 42 wb. At 425 72 db 54 wb. She was happy. I had the opposing opinion.
@MinnesotaHvAc
@MinnesotaHvAc 3 жыл бұрын
I should really proof read. 300÷12000 btus per ton equals 400 cfm. As you watch this figure wb and db will rise and fall. The totals will remain. I know the apps say 11 12 10 wb. There wrong. There write. All I know is what I read. I always wondered why the slide charts said wb db in and only gave db out. That was never good enough for me.
@MR-nl8xr
@MR-nl8xr 3 жыл бұрын
@@MinnesotaHvAc yea bro, proof read more. I'm sure what you are saying is true, but I don't know wtf it says.
@MinnesotaHvAc
@MinnesotaHvAc 3 жыл бұрын
@@MR-nl8xr then you should write down your readings and soon you will abbreviate. Then you'll understand me. Wet bulb dry bulb saturation temperature supply dry bulb wet bulb and so on. Happy new year let's all own our smithing and be the best at what we do. Contron envirments. Remove water vapor add heat so our customers can sleep well at night. HAPPY NEW YEAR BROTHERS.
@MR-nl8xr
@MR-nl8xr 3 жыл бұрын
@@MinnesotaHvAc I know the abbreviations, it was the rest that's not understand able. It seems like you too know the fact about the humidity control solution to this "pandemic" with IAQ control i. 40-60% rH. Yeah, have a Freer & Happy New Year Man.
@MinnesotaHvAc
@MinnesotaHvAc 3 жыл бұрын
@@MR-nl8xr happy new year. Realworldhvac@gmail.com if you want to chat hvac.
@napoguevara6450
@napoguevara6450 3 жыл бұрын
👍
@napoguevara6450
@napoguevara6450 3 жыл бұрын
🧏🏻‍♀️
@williamtsol636
@williamtsol636 2 жыл бұрын
👍
HVAC 098 ΔT  Delta T  Delta Temperature
17:01
Love2HVAC with Ty Branaman
Рет қаралды 13 М.
HVAC Delta-T, Is it a Fixed or Moving Number? Collab with HVAC School!
11:07
AC Service Tech LLC
Рет қаралды 27 М.
Magic trick 🪄😁
00:13
Andrey Grechka
Рет қаралды 39 МЛН
小丑把天使丢游泳池里#short #angel #clown
00:15
Super Beauty team
Рет қаралды 39 МЛН
How I Did The SELF BENDING Spoon 😱🥄 #shorts
00:19
Wian
Рет қаралды 35 МЛН
What Should the Air Delta T be? (Air Temperature Split)
9:17
HVAC School
Рет қаралды 61 М.
Delta T, temperature difference (dt) with heat pumps and boilers
16:28
HVAC Troubleshooting | Low (and Strange) Delta T Issues
8:52
HVAC Shop Talk
Рет қаралды 3,2 М.
Delta T’s and Blower Speeds.. HVAC Service Call
8:11
HVAC Tech Tips
Рет қаралды 10 М.
HVAC 099 TD Temperature differential 2 different substances
24:26
Love2HVAC with Ty Branaman
Рет қаралды 17 М.
HVAC 106 Scenario Restriction and non-condensable
14:02
Love2HVAC with Ty Branaman
Рет қаралды 28 М.
HVAC Companies HATE That You Can Do This Yourself.
25:51
The DIY HVAC Guy
Рет қаралды 534 М.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Jersey Mike HVAC
Рет қаралды 26 М.
What is the proper temperature drop for air conditioning?
15:32
HVAC Service Mentor
Рет қаралды 20 М.