No video

EEV Valves and Power Heads

  Рет қаралды 11,027

HVAC is WIN

HVAC is WIN

Күн бұрын

Пікірлер: 28
@electrolatif
@electrolatif 4 ай бұрын
I see other people talk a lot and show a bit, but you unique ❤ and people understand well Good teacher
@lucasmccain4833
@lucasmccain4833 4 ай бұрын
It actually works, I bought one to unstick an EEV in an over engineered POS Trane Tam7
@jrh86
@jrh86 7 ай бұрын
Very interesting and informative 💯👍👍👍
@JaykeSapalaran-iq3qs
@JaykeSapalaran-iq3qs Жыл бұрын
Great video information ❤👍 thanks for sharing your knowledge ♥️🇵🇭
@arashgharedashi9205
@arashgharedashi9205 15 күн бұрын
Tank u bro
@mylesm7947
@mylesm7947 Жыл бұрын
Thanks for your time and information 👍
@brandanchalfant2187
@brandanchalfant2187 2 жыл бұрын
Good stuff bud, thanks for sharing the tips.
@christergudmundsson7465
@christergudmundsson7465 Жыл бұрын
Hmmmm.... Many home made experts talking a lot.. the different between you and them is that you do not talk more then it needs and knowing what you are talking about...(-: (-; GREAT!!!
@hvaciswin723
@hvaciswin723 Жыл бұрын
Thank you!
@jaymz0074
@jaymz0074 Жыл бұрын
Great video, thank you.
@ebbyt00
@ebbyt00 9 ай бұрын
Thanks for the Video,what is the ID of the Daikin magnet? My TEEV has a larger OD .
@dammo361
@dammo361 6 ай бұрын
Good video thanks
@HailStonE999
@HailStonE999 2 жыл бұрын
Can you use WD40 on both parts to avoid rusting all together???
@hvaciswin723
@hvaciswin723 2 жыл бұрын
Yes but near costal areas will still need to clean regularly
@jrsmyth9761
@jrsmyth9761 2 жыл бұрын
Mitsubishi has a grease they recommend putting on/in these after cleaning.
@pinionzero1
@pinionzero1 2 ай бұрын
@jrsmyth9761 would you happen to know the part number for this Mitsubishi grease?
@matttzzz2
@matttzzz2 5 ай бұрын
If one out of 4 indoor units in an LG multi-head system is not heating, what could its EEV be doing? Stuck open or closed or partially open or partially closed?
@hvaciswin723
@hvaciswin723 15 күн бұрын
I would think closed, but thermistors control the valves position. Youll need to check them as well.
@jeromefriolet9076
@jeromefriolet9076 Жыл бұрын
What are the common issues with the rusted power heads? Other then fujitus bad eev coils shorting out (current model), ive never had issues. So im curious as to what to look out in the future
@hvaciswin723
@hvaciswin723 Жыл бұрын
Reduced magnetic pull on the needle valve in side the valve body
@hvaciswin723
@hvaciswin723 Жыл бұрын
it could act like stuck valve
@lokeshlokeshkumar2107
@lokeshlokeshkumar2107 Жыл бұрын
Hai.. Sir..
@user-tp8ef5xu8t
@user-tp8ef5xu8t 10 ай бұрын
Never heard of anyone cleaning these things
@user-tb5sf4oz1u
@user-tb5sf4oz1u 2 жыл бұрын
I can use any magnet?
@hvaciswin723
@hvaciswin723 2 жыл бұрын
Not with daikin that particular magnet is required or theres another tool i use made by eevmate. Check them out
@harshmehta374
@harshmehta374 2 жыл бұрын
Im from 🇮🇳 any job for helper pls...
@hvaciswin723
@hvaciswin723 2 жыл бұрын
Usa is needing workers in the HVAC field
@tsetsivito
@tsetsivito 8 ай бұрын
This is for rookies.A decent magnet does the job.Poor guy.
Electronic Expansion Valve Tutorial
6:01
Temperzone Climate Innovations
Рет қаралды 6 М.
Ручное управление механизмом ЭРВ.
11:33
Shared Data programming
7:01
HVAC is WIN
Рет қаралды 3 М.
HOW TO TEST DAIKIN EEV COIL (5 Cables).
12:23
Mitch Attwood
Рет қаралды 15 М.
MAGNETRON - Teardown + How It Works - Dangerous!
14:07
Electronoobs
Рет қаралды 902 М.
Electronic Expansion Valve - How it works ETS 5M HVAC
13:41
The Engineering Mindset
Рет қаралды 365 М.
EEV Magnets? Can’t I just use a solenoid magnet?
5:03
Quentin Butler HVAC
Рет қаралды 6 М.
Как открыть эрв кондиционера
8:16
Doctor HVAC
Рет қаралды 10 М.
Solenoid valves | The Beauty of Engineering
9:48
Lesics
Рет қаралды 1 МЛН
Testing House Outlet with Multimeter---Easy!!
9:22
Flashback502
Рет қаралды 465 М.