REVIEWED: IP66 Wiska Combi Box and earth clamp bar.

  Рет қаралды 26,677

eFIXX

eFIXX

Күн бұрын

Always on the search for products to make a tidier installation Joe Robinson checks out the Wiska Combi junction box range. Will the earth clamp bar from the Wiska 308 also fit the Wiska 206?
The IP66 rating of the Wiska Combi range makes them ideal for garden lighting installation. The earth clamp bar speeds up the termination of SWA cables.
🕐 TIME STAMPS 🕕
======================
00:00 Introducing the Wiska 308 junction box
00:25 The challenges of banjos
00:46 Earth clamp bar
01:30 How does the Wiska earth clamp bar work?
02:25 Does the earth clamp work with the Wiska 206 box?
03:45 Wiska box mounting options
04:07 Terminal block features
04:34 Cover attachment
======================
== AD ===========================
🧰 Check price and availability
WISKA 308 Combi 85 X 85 X 51MM Outdoor Junction Box Waterproof IP66 - Black
amzn.to/2CCr99H
WISKA Box Combi 206 Black Empty IP66
amzn.to/3g8SLRw
Wiska 10101473 Combi Ec308 Earthing Plate
amzn.to/2FtamXy
================================
📍SUBSCRIBE TO THE CHANNEL
kzfaq.info?sub_con...
================================
📺 NEW TO THE EFIXX CHANNEL
Watch our essential videos playlist
• NEW TO eFIXX - ESSENTI...
================================
🎥 CATCH UP ON THE LATEST VIDEOS
kzfaq.infovideo...
================================
🛠 ELECTRICIANS' TOOL REVIEWS
• Electricians' tool rev...
================================
🧲 EFIXX NEWSLETTER
Sign up to find out about our live events, competitions and product giveaways.
www.efixx.co.uk/sign-up
================================
📝 APPRENTICE HUB
If you're an electrical apprentice, retraining as an electrician or looking to refresh your knowledge, then please check out our apprentice hub. It contains thousands of multiple-choice questions to help prepare for electrical installation exams.
www.efixx.co.uk/apprentice-hub
=================================
SOCIAL
✅ INSTAGRAM - See our behind the scenes action.
efixx_insta...
✅ LINKEDIN - Latest electrical news and trending content.
/ efixx
==================================
❌ This content on this channel is for electrical professionals.❌
==================================
🎦 Presented by
Joe Robinson - technical editor eFIXX
#efixx #morepower

Пікірлер: 35
@johnhoward2104
@johnhoward2104 4 жыл бұрын
Nicely done Joe 👍😀
@markgilder9990
@markgilder9990 3 жыл бұрын
Always threw that grey bit away. Now I know what it’s for.😂😂
@robinpenny3193
@robinpenny3193 2 жыл бұрын
A comment on the Storm Gland video pointed out that the grey bracket is handy for attaching to concrete posts like those behind Joe - if you use the screw holes on the corners of the box to maintain the IP rating, you will break the edges of the post when drilling, as I found out yesterday...
@stevendouglas3860
@stevendouglas3860 4 жыл бұрын
Great box
@RWATraineeElectrician
@RWATraineeElectrician 4 жыл бұрын
Oooh "banjo" I can hear Gaz tutting in disapproval in the background 😆😆😆
@greenpearlelectricalremedi5190
@greenpearlelectricalremedi5190 3 жыл бұрын
Installed a lot the whisks boxes wish I had found out about the brackets then.
@normanboyes4983
@normanboyes4983 4 жыл бұрын
You can fettle the brass plate a wee bit to allow the second gland to enter (half round file) as you will still achieve contact with the screw. Or just put hair round it.😉
@efixx
@efixx 4 жыл бұрын
Excellent use of fettle there Norman, love that! (Joe)👍
@oliverriall
@oliverriall 3 жыл бұрын
With a bit of persistence you can use the 206 boxes with the earth bar, just takes a bit of jiggery and don't do one tight until you have the other one in.
@dannyakqj101
@dannyakqj101 4 жыл бұрын
Brilliant idea, does the grub screw for the earth clamp damage the thread on the gland though??? I am thinking maybe the earth bar could be threaded.
@oliverriall
@oliverriall 3 жыл бұрын
Can't have two threads in a row like that as they will not be perfectly aligned.
@waynio67
@waynio67 4 жыл бұрын
The ones I fit now have wago’s in now
@mrmoly55
@mrmoly55 4 жыл бұрын
Use the EC206 Earth Clamp 👍
@DaddyBear3000
@DaddyBear3000 3 жыл бұрын
If you can find them somewhere, let me know. Seems Wiska are trying to get more money from us for the EC 607’s
@johnny1408
@johnny1408 Жыл бұрын
Hi could you please tell me what is the differance in the 308 and the 308/5 please as im doing the exact job as you have done here. Thanks
@nigelsansom2407
@nigelsansom2407 3 жыл бұрын
Poss dumb question coming up (but I am not an electrician so be gentle): If earth continuity is maintained through the incoming and outgoing SWA cables via the earth plate... what is the flylead nut for. Is that just for connecting an earth lead from the plate to a nut on the back of a metal box (if you're using one rather than a Wiska box), or do you connect it into the same connector as all the core earths go into (like a five-way Wago connector)..?
@schrodingerscat1863
@schrodingerscat1863 2 жыл бұрын
The earth plate connects to metal armour in the cable you should then connect this to the earth conductor in the cable. The armour should not be used as an earth conductor but it should be earthed.
@johnny1408
@johnny1408 Жыл бұрын
Just a quick question i had 4 of these boxes delivered in error from a company as the Storm gland would not fully screw through the threaded entry because of the rubber membrane being in the way so what is the differance in the 308 and 308/5 box. Also i was unable to screw 2 20mm storm glands side by side why is this please.
@anthonysalisbury6945
@anthonysalisbury6945 Жыл бұрын
Just had an install done, armoured from outside into house....doesn't look right due to bend radius, should the armoured have been terminated into this type of box and twin & earth passed through the wall and jointed in this box?
@PaulConnor100
@PaulConnor100 2 жыл бұрын
what size of drill bit did use in the wiska 308 box holes where 20mm glands go in. I tried screw them and just wrecks the threads not piercing rubber or plastic rim like there meant to. 🤷‍♂️
@joem9124
@joem9124 Жыл бұрын
I just thread the gland into the box with adjustable spanner and it pops the rubber thing out
@odinnln5694
@odinnln5694 3 жыл бұрын
Wago 221 connector block?
@jasonelson7238
@jasonelson7238 4 жыл бұрын
They are good and good review but I think your a bit late on these been fitting these for years👍👍
@philedwards4505
@philedwards4505 4 жыл бұрын
What no push fit connection block !
@crumps84
@crumps84 3 жыл бұрын
Does anyone use the connector block that comes with it or do people do what I would do and just use wagos or similar?!?
@Chris-hy6jy
@Chris-hy6jy 3 жыл бұрын
The one I installed this week came with wago 221s and a mounting bracket for the wagos. Must admit the bracket looked like a faf so I just binned it and left the wagos floating in the box 😂
@oliverriall
@oliverriall 3 жыл бұрын
It upsets me a little that I have thrown so many of those in the bin, the 206's come with 221's now which is soooo much better.
@tom_programator2566
@tom_programator2566 4 жыл бұрын
which is the difference between curve circuit breakers b and c 1p+n
@TheChipmunk2008
@TheChipmunk2008 4 жыл бұрын
instantaneous trip current. I think B is 3-5x In, C is 5-10x In, and D curve up to 20x In. Typically UK breaker boards use B curve for general purpose circuits. Some EU countries use C curve for this. D curve is for stuff with a HUGE inrush current
@tom_programator2566
@tom_programator2566 4 жыл бұрын
@@TheChipmunk2008 Well here is the question why france belgium use curve c and england germany use curve b
@tom_programator2566
@tom_programator2566 4 жыл бұрын
@@TheChipmunk2008 vde rules are the same everywhere the English norms are also derived from vde with derogation
@tom_programator2566
@tom_programator2566 3 жыл бұрын
@@TheChipmunk2008 in which situation 1p + n is used in the conditions in which n has no protection
@TheChipmunk2008
@TheChipmunk2008 3 жыл бұрын
@@tom_programator2566 I believe it's in some situations where isolation is REQUIRED in all 'live' poles. N is considered a Live conductor now, especially on TN-C-S where an open PEN could cause it to rise to phase voltage. So having either a DP breaker with linked handles (essential, and usually the trip mechanisms are linked internally too), or a similar device with no OCP on the neutral, but linked to the Phase device...
@user-et7qy6ss6j
@user-et7qy6ss6j 4 жыл бұрын
مرحبا السلام عليكم
Holey Plugs, Batman! But... what are they for?
20:32
Technology Connections
Рет қаралды 5 МЛН
لااا! هذه البرتقالة مزعجة جدًا #قصير
00:15
One More Arabic
Рет қаралды 30 МЛН
A teacher captured the cutest moment at the nursery #shorts
00:33
Fabiosa Stories
Рет қаралды 57 МЛН
EVOLUTION OF ICE CREAM 😱 #shorts
00:11
Savage Vlogs
Рет қаралды 13 МЛН
Finger Heart - Fancy Refill (Inside Out Animation)
00:30
FASH
Рет қаралды 29 МЛН
COMBI Junction Boxes presents new COMBI 407
4:31
WISKAChannel
Рет қаралды 61 М.
The Clever Way to Count Tanks - Numberphile
16:45
Numberphile
Рет қаралды 798 М.
Parts of a SWA Cable Gland - BW and CW - Electrical Wiring
10:16
GSH Electrical
Рет қаралды 15 М.
Garden Lighting: Tips for Installing a WISKA COMBI 108 box for ELV lights
8:51
Garage fuse board upgrade, wiska 308
14:45
N Bundy Electrical
Рет қаралды 21 М.
BIGGEST DIY Mistakes Joining Cables
8:52
The Diligent DIYer
Рет қаралды 225 М.
The Jaw-Dropping Difference Between AC & DC Isolators!
5:39
Nokia 3310 top
0:20
YT 𝒯𝒾𝓂𝓉𝒾𝓀
Рет қаралды 4,6 МЛН
Что делать если в телефон попала вода?
0:17
Лена Тропоцел
Рет қаралды 3,6 МЛН
Частая ошибка геймеров? 😐 Dareu A710X
1:00
Вэйми
Рет қаралды 6 МЛН