No video

How to do the Bresle Patch Test using an Elcometer Bresle Test Patch

  Рет қаралды 91,298

Elcometer Inspection Equipment - Coatings Industry

Elcometer Inspection Equipment - Coatings Industry

Күн бұрын

Discover how to do the Bresle method using the Elcometer Bresle Test Patch, supplied with the Elcometer 138 and 138B Bresle Salt Kit, and see how to measure soluble salts in accordance with ISO 8502-6 and ISO 8502-9.
With 19% thicker foam walls, high quality adhesive and easy to peel off the substrate leaving no foam residue, the Elcometer 135C Bresle Test Patch is ideal for measuring soluble salts in the field using the Bresle Method.
The Elcometer Bresle Test Patch also has an easy to remove clear protective film which keeps the patch clean prior to testing.
Contamination of steel surfaces from soluble salts - such as chloride, sulphate, or nitrate ions - can lead to premature coating failures. By measuring and monitoring the concentration of soluble salts, you can ensure that the surface is clean enough for a coating to be applied.
The Bresle Patch Test has been the most often referred to method for measuring the concentration of soluble salts on steel surfaces - prior to and after blasting, cleaning, and coating - for more than 20 years.
The Elcometer Bresle Test Patch can determine the concentration of soluble salts on uncoated surfaces and can be used in accordance with the ISO 8502-6 test method.
Available in packs of 25 or 100, the Elcometer 135C Bresle Test Patch is supplied with Certificate of Cleanliness for peace of mind.
For more information on the Elcometer 135C Bresle Test Patch, visit: www.elcometer.c...
For more information on the Elcometer 138 Bresle Salt Kit range, visit: elcometer.com/e... or contact Elcometer at sales@elcometer.com
----
Click here to download the video script in in English: www.elcometer....
-----
STANDARDS:
Elcometer 135C Bresle Test Patch:
ISO 8502-6, ISO 8502-9*
*When used in conjunction with an Elcometer 138 or 138E Conductivity Meter
Elcometer 138 Bresle Salt Kits:
AS 3894.6-A, IMO MSC.215 (82), IMO MSC.244 (83), ISO 8502-6, ISO 8502-9, SSPC Guide 15, US Navy NSI 009-32, US Navy PPI 63101-000

Пікірлер: 34
@ramananthm4624
@ramananthm4624 5 жыл бұрын
Excellent explanation
@jamesosaro5312
@jamesosaro5312 5 ай бұрын
Good one
@PINTURAINDUSTRIALRODRIGUES
@PINTURAINDUSTRIALRODRIGUES 2 жыл бұрын
Very good!
@malarrajah
@malarrajah 10 ай бұрын
Could you please explain about the C value test procedure. Thank you
@ElcometerOfficialChannel
@ElcometerOfficialChannel 10 ай бұрын
Thank you for your comment, @malarrajah. Could you please clarify on what you mean in regards to your comment?
@user-ey7nv1yw4o
@user-ey7nv1yw4o 3 ай бұрын
Hi As per ISO 8502-6, Table A-1 (Annex A) for A-1250 Patch which is indicated in Elcometer 138 instructions manual the volume of injected water to be 14.9 ml (+ - 1 ml). Why do you specify 3 ml water?
@ElcometerOfficialChannel
@ElcometerOfficialChannel 3 ай бұрын
Hi, Annex A for A-1250 refers to a leak test, meaning more water must be injected. For working inspection test we advise injecting 3ml as per ISO 8502-6 If you have any more questions, please get in touch at support@elometer.com
@andigustian2418
@andigustian2418 3 ай бұрын
What is the standard for limiting salt content in blasting sand, for example copper slag? Please reply😊
@ElcometerOfficialChannel
@ElcometerOfficialChannel 3 ай бұрын
Hi, This would be determined by your job specification and / or your blasting sand supplier. If you have any more questions, please get in touch at support@elcometer.com
@shuvrowalam
@shuvrowalam 5 жыл бұрын
Would you please describe (or give the link of video if any) how to calibrate elcometer 13E ?
@ElcometerOfficialChannel
@ElcometerOfficialChannel 5 жыл бұрын
Thank you for your comment. There are instructions on how to calibrate the Elcometer 138E Conductivity Meter in the Elcometer 138 Basic Bresle Kit Instruction Book. You can view the book by clicking on this link: www.elcometer.com/images/stories/PDFs/MultiLingualInstructionBooks/138_Basic.pdf Simply go to page en-10 (section 5.6 CONDUCTIVITY CALIBRATION) to read instructions on how to calibrate the meter. If you have any further questions, please contact techsales@elcometer.com or visit www.elcometer.com/contact-us to find your local Elcometer distributor.
@phonghoang1432
@phonghoang1432 3 жыл бұрын
Please give some detail explanation why ISO 8502-6 and IMO PSPC requires 2 different convert factor 1.2 and 1.1 respectively?
@ElcometerOfficialChannel
@ElcometerOfficialChannel 3 жыл бұрын
Thank you for your comment. As it explains in the instruction manual for the Elcometer 138 Bresle Salt Kit, ISO 8502-6 is a conversion for a mix of salts (so all soluble salts), whereas IMO PSPC is looking for the density of sodium chloride only, hence the difference. If you have any further questions please contact techsales@elcometer.com or visit www.elcometer.com/contact-us to find your local Elcometer distributor.
@darylstaples8409
@darylstaples8409 Жыл бұрын
I just done an Icorr exam and one of the questions from what I remember was regarding the thickness of the patch 1mm, 1.5mm, 5mm, 10mm I’m sure I got the answer wrong and I cannot find the information😅
@ElcometerOfficialChannel
@ElcometerOfficialChannel Жыл бұрын
Hi, Thank you for the comment! The answer you are looking for is 1.5mm. If you have any further questions, please get in touch with our tech team at techsales@elcometer.com
@acapulcoscebu449
@acapulcoscebu449 Жыл бұрын
does this test for chorides , sulphates and nitrates
@ElcometerOfficialChannel
@ElcometerOfficialChannel Жыл бұрын
Hi, Thank you for your comment! Yes, it does test for all three and provides a result of all three in a single metric. If you would like to measure them individually you would need to use our CSN kit available here: www.elcometer.com/en/coatings-inspection/all-coatings-inspection/inspection-kits/elcometer-134-csn-chloride-sulphate-nitrate-test-kit.html If you have any further questions please email techsales@elcometer.com
@irfananwar7147
@irfananwar7147 Жыл бұрын
What is maximum acceptable limit for salts before or after coating?
@ElcometerOfficialChannel
@ElcometerOfficialChannel Жыл бұрын
Hi, These limits are specified by your particular job specification and possibly the paint data sheet. Defined standards are yet to be created for this kind of test. For more information please get in touch @techsales@elcometer.com
@harvishtechnicalservices1609
@harvishtechnicalservices1609 Жыл бұрын
In Batch certificate, the mean ionic concentration values (Cleanliness) shall be deducted or not??
@ElcometerOfficialChannel
@ElcometerOfficialChannel Жыл бұрын
Hi, We can confirm that the Mean Ionic Concentration should be deducted from the final test. If you have any further questions please get in touch @techsales@elcometer.com
@Jawahar1995
@Jawahar1995 3 ай бұрын
What if we get more chloride than the specified limits in our specifications? What is the solution after getting higher chloride levels?
@ElcometerOfficialChannel
@ElcometerOfficialChannel 3 ай бұрын
Hi, If your chloride levels exceed specified limits we suggest thoroughly washing the surface using deionised water, and then repeating the test. Please ensure you are conducting the test accurately and precisely as per the video. If you have any more questions, please get in touch at support@elometer.com
@praveenpappa4683
@praveenpappa4683 14 күн бұрын
@@ElcometerOfficialChannel after repeating the test, should it required blasting again? because there may be a chance of flash rusting on the surface if the surface washed using deionised water? Please advice. Normally at site, subcontractor is washing with portable water and re-blast the surface to achieve the cleanliness.
@ElcometerOfficialChannel
@ElcometerOfficialChannel 5 күн бұрын
Hi, Whether you need to wash again really depends on the results of the brestle patch. If the salt level is unacceptable they'll have to wash again
@elumalaielumalai08
@elumalaielumalai08 Жыл бұрын
Why should we multiple original value with 1.2 and 1.1?
@ElcometerOfficialChannel
@ElcometerOfficialChannel Жыл бұрын
Hi, We multiply the original value with 1.2 and 1.1 because the measured conductivity is converted to surface density of salts using the ISO Salt Mix or IMO PSPC equivalent NaCI conversion factors. ISO Salt Mix: mg/m² = x1.2 µg/cm² = x0.12 IMP [S[C equivalent NaCl mg/m² = x1.1 µg/cm² = x0.11 For further information, please get in touch at techsales@elcometer.com
@Dingzerovn
@Dingzerovn 3 жыл бұрын
Are Elcometer E138CM (Conductivity Meter) or E138BSM ( Bresle Salt Meter) temperature compensated? Because I don't see the statement in datasheet or use guide?
@ElcometerOfficialChannel
@ElcometerOfficialChannel 3 жыл бұрын
Thank you for your comment. Both the Elcometer 138 Conductivity Meter and Bresle Salt Meter are temperature compensated to 25°C (77°F). For more information please contact techsales@elcometer.com or visit www.elcometer.com/contact-us to find your local Elcometer distributor.
@user-ul6mo4mk7z
@user-ul6mo4mk7z 9 ай бұрын
What's ER4 error?
@ElcometerOfficialChannel
@ElcometerOfficialChannel 8 ай бұрын
Hi, ER4 suggest there has been a calibration failure - this is typically due to the ranges being too far out from the known calibration solutions, or possibly a sensor error. We would suggest recalibration. If this still doesn't work, please get in touch at support@elcometer.com
@liu54650
@liu54650 Жыл бұрын
單位是ms,要如何轉換mg\m2
@ElcometerOfficialChannel
@ElcometerOfficialChannel Жыл бұрын
Hi, 1 microsiemen is 0.001 millisiemens Therefore 1mS is equivalent to 1000μS. For further information please contact tech support @techsales@elcometer.com
@gabanlange9793
@gabanlange9793 Жыл бұрын
answer is at 3:47 of the video
How to Measure Soluble Salts using the Elcometer 130 Soluble Salt Profiler
5:14
Elcometer Inspection Equipment - Coatings Industry
Рет қаралды 39 М.
Мы сделали гигантские сухарики!  #большаяеда
00:44
UNO!
00:18
БРУНО
Рет қаралды 5 МЛН
天使救了路飞!#天使#小丑#路飞#家庭
00:35
家庭搞笑日记
Рет қаралды 89 МЛН
Prank vs Prank #shorts
00:28
Mr DegrEE
Рет қаралды 8 МЛН
Testing Coatings using an Elcometer Pulsed DC Holiday Detector
9:45
Elcometer Inspection Equipment - Coatings Industry
Рет қаралды 53 М.
Measuring Surface Profile using the Elcometer 122 Replica Tape & Elcometer 124 Thickness Gauge
4:54
Elcometer Inspection Equipment - Coatings Industry
Рет қаралды 147 М.
Pull-off adhesion ASTM D4541 [Paint Testing]
2:32
Spektrochem Paint Technical Center
Рет қаралды 49 М.
abrasive test(steel grit)
4:29
GoRae TV
Рет қаралды 20 М.
Salt Test, Soluble Salt Test Method - How to Use Bresle Test Patch New Video
4:38
The Institute for Oil & Gas Sector (IOGS)
Рет қаралды 23 М.
Testing for Pinholes with the Wet Sponge Method using the Elcometer 270 Pinhole Detector
6:05
Elcometer Inspection Equipment - Coatings Industry
Рет қаралды 51 М.
замеры запыленности рама 1704
13:34
макс отто фон штирлиц
Рет қаралды 489
Salt Testing by Salt Contamination Meter Prior to Coating Application
4:50
The Institute for Oil & Gas Sector (IOGS)
Рет қаралды 13 М.
Мы сделали гигантские сухарики!  #большаяеда
00:44