Electrician: "This is a weird fault" | Electrical Fault Finding

  Рет қаралды 11,236

Eastway Electrical

Eastway Electrical

5 ай бұрын

In this video I'm investigating a weird electrical fault in a loft extension. Enjoy!
To hire Eastway Electrical for work in your property please visit our website:
www.eastwayelectrical.com
Social Media links:
Linkedin: / delroyjames
Instagram: / eastwayelectrical
TikTok: / eastwayelectrical
To help me create content more consistently, upgrade equipment you can support via PayPal:
paypal.me/delroythespark

Пікірлер: 70
@lewistempleman9752
@lewistempleman9752 5 ай бұрын
Customer: so is it unsafe? Delroy: no no no, um, yeah end of video
@robertburrows6612
@robertburrows6612 5 ай бұрын
You should change that second RCD in that small board in the loft conversion for a main switch , you don't have two 30 ma RCD one upstream to the other , plus you should change that wylex MCB for a mk one , at you should have notified the customer that work needs to be carried out ,
@elliotcleveland9121
@elliotcleveland9121 5 ай бұрын
Nice hole with no gromit in the bottom of the board with the tails coming through 🤔
@Nigel1969
@Nigel1969 5 ай бұрын
Forget grommet lol ...needs a tails gland really for support and also no Discrimination (or selectivity) i think on the rcd`s but i didnt look close
@curtisj2165
@curtisj2165 5 ай бұрын
I was about to make the same comment. I would prefer the main earth to go through the same hole as the tails in a tail gland
@no_short_circuit
@no_short_circuit 5 ай бұрын
Great detective work Delroy....
@user-ty8rr6vg1i
@user-ty8rr6vg1i 5 ай бұрын
Exactly what I thought. I've started looking at jobs from the perspective of what wouldn't I do first ....most of the times I find the issue quickly.
@davidpenn2518
@davidpenn2518 5 ай бұрын
Good start with Bottom entry Man Tails with no gromet and I'm not even a Spark to notice that..
@jameshansing5396
@jameshansing5396 5 ай бұрын
probs why you said grommet and not tails gland ?
@davidpenn2518
@davidpenn2518 5 ай бұрын
You know what I mean, cables should be in a 'gromet / gland etc.' I just mentioned the mistake which should be enough said... and I am not a Spark...
@jameshansing5396
@jameshansing5396 5 ай бұрын
No you know tails glands are a thing. You're welcome....@@davidpenn2518
@abdulseaforth6930
@abdulseaforth6930 5 ай бұрын
That’s it then- you’ve sorted it! Not bad for a non-spark
@arniewheeler4673
@arniewheeler4673 5 ай бұрын
11:18 what a ridiculous place to position a sub board
@jordanbballmight
@jordanbballmight Ай бұрын
Well done del
@Bazza-tn5ck
@Bazza-tn5ck 5 ай бұрын
Ditch the RCD in sub-board in loft 👍
@ChristmasCrustacean1
@ChristmasCrustacean1 5 ай бұрын
or move the 50A breaker off the RCD in the second board
@Bazza-tn5ck
@Bazza-tn5ck 5 ай бұрын
Front end RCD no main switch so not possible, also the feed from main consumer unit to sub-board was in T+E and the installation method would require supplementary protection so would therefore need to be clipped surface or otherwise suitably protected from damage I.e. armoured cable or trunking. So only viable option is remove RCD and sub-board therefore achieving “discrimination” and eliminating possibility of 2 RCDs tripping👍👍
@Bazza-tn5ck
@Bazza-tn5ck 5 ай бұрын
Sorry edit that 🤦‍♂️ the consumer unit is spilt load not front end as I first thought (look better 😅)
@yacinehachani9754
@yacinehachani9754 5 ай бұрын
2 RCD will fight each other
@benpatana7664
@benpatana7664 5 ай бұрын
Two RCDs in the circuit is just asking for issues - suggestive of a DIY bodge job or an incompetent spark. That needs to be corrected and the loft circuit(s) fully tested as there may well be an underlying fault - I don't think that would be wasting the customer's time and money. I'd also question the positioning of the loft circuit board. It is too concealed like that and needs to be more accessible.
@ChristmasCrustacean1
@ChristmasCrustacean1 5 ай бұрын
builders special, thats a BG garage board hanging off a different model breaker than the board its sitting in
@almerdiahmed3160
@almerdiahmed3160 5 ай бұрын
Nice job 🎉🎉🎉🎉🎉
@AL___667
@AL___667 5 ай бұрын
Is there a borrowed neutral on the stairs lighting to the loft? Lights in original part look to be on the right RCD, loft on the left.
@wolflouis_official
@wolflouis_official 5 ай бұрын
No gland either on those main tails mate oops
@curtisj2165
@curtisj2165 5 ай бұрын
I would reconfigure the board downstairs so that the loft feed is non rcd protected. Two rcd's on that loft feed is asking for trouble
@_chrisr_
@_chrisr_ 5 ай бұрын
but that would require that the 6mm cable feeding it be protected mechanically which probably isn't possible now that it is installed. Easier just to remove the RCD in the sub-board since it isn't adding anything and since it has same rating as the one on the main board it can be a bit random as to which one will trip out first.
@moodyga40
@moodyga40 5 ай бұрын
no gland on the tails too
@simonmaverick9201
@simonmaverick9201 5 ай бұрын
2:44 no gromet on the incomer tails!!!
@ChristmasCrustacean1
@ChristmasCrustacean1 5 ай бұрын
this needs consolidation into one board
@Bespokeelectrics
@Bespokeelectrics 5 ай бұрын
If you fancy swapping testers you can have my 1741+ and I’ll take your X1! 😂
@chas3997
@chas3997 5 ай бұрын
Could be a timer or strapper wire circuit and poor run borrowed neutral running back through the wrong RCD when a two way switch is operated
@electrickal1
@electrickal1 5 ай бұрын
Didn't you hear that macerator motor cycling when he turned on the RCD? That starting and stopping will generate tripping spikes that will have undoubtedly caused the problem. A crossed wired neutral will trip every time a load exceeding the rated ma of the RCD is applied, so definitely not that.
@ratbag359
@ratbag359 5 ай бұрын
the pump may be faulty from short cycling.
@joparish1037
@joparish1037 5 ай бұрын
Screwfix special BG consumer unit. That macerator would be the likely candidate for nuisance tripping.
@T_Perkins
@T_Perkins 5 ай бұрын
Ooo dibs on the macerator causing an issue. Random trip from a thinking of needing a good ol' mash up to 'oh, no, wait, no one's done doo doo, my bad,' RCD be like - kids be playing switch the power off. That's my only street talk way of saying without getting technical. Lol!
@metallitech
@metallitech 5 ай бұрын
Recommend more dietary fibre for the lady and get out of there.@@T_Perkins
@chas3997
@chas3997 5 ай бұрын
First fuse board needs tail gland plus same type tested type A RCD & mcbs . The whole Job screams of dangerous diyer or builder.
@arniewheeler4673
@arniewheeler4673 5 ай бұрын
poor install, is that a 30ma main switch too? no discrimination?
@FFPMG1542
@FFPMG1542 5 ай бұрын
Why don’t you like the MFT x1 was looking at getting one. Curios to know why you don’t like it
@calvinspark1946
@calvinspark1946 5 ай бұрын
I kneoow…nope nope nope 😂
@Wolfhound.
@Wolfhound. 5 ай бұрын
the pump going on and off all the time could have did it maybe it got hot
@train4905
@train4905 3 ай бұрын
Well traced dell😊😊
@DICEGEORGE
@DICEGEORGE 5 ай бұрын
if you could pull 2 wires down to the main consumer unit then all the rcds could be down there.
@Vijaysingh-zp1ql
@Vijaysingh-zp1ql 5 ай бұрын
For work permit electrical work
@justmeEnglandUK
@justmeEnglandUK 5 ай бұрын
Bet something got stuck in the sanilflow and stopped the pump from spinning .
@michaelcox4081
@michaelcox4081 5 ай бұрын
I dislike my X1 as well. I’m going to return mine.
@abdulseaforth6930
@abdulseaforth6930 Ай бұрын
Hi Michael, what do you not like about the X1- I’m on the lookout for a new MFT. I have the Megger 1730
@michaelcox4081
@michaelcox4081 Ай бұрын
@@abdulseaforth6930 it’s missing a lot of the functions the the 1741, like stake-less earth testing, the (pure) auto test for Ze/s and RCD. It keeps showing neutral errors when doing the fake auto test, even when the leads are pre connected and the load is then switched on. When choosing different RCD testing modes it keeps changing the testing mA which is frustrating when the tester is a long way from the board and you don’t realise until halfway through / after the test. The battery is pants and will / can die without warning. When conducting 3-phase testing the switching of the leads around to different ports is a nightmare and can catch you out if you get complacent. The link to the CertSuite software it’s just gimmicky and as the tester can be nightmare for testing, it can take twice as long to get the relevant results sent across to the software, also if you haven’t got the tester, or the software set up correctly, the results just disappear. I found the 1741 was its own tester with its own user-friendly quirks however the X1 is very similar to a Kewtech in the way it operates. Megger might have done a software update but their website is still showing the original firmware and no updates. Currently, my X1 is sitting in a bag doing nothing and I’ve gone back to my 1741
@electrickal1
@electrickal1 5 ай бұрын
What a crock of shit that installation is. Unsupported meter tails, no entry gland to a steel board, no labelling, incorrect MCB's, blah de blah de blah. AND they have the cheek to put an NICEIC label on it!!!!!
@abdulseaforth6930
@abdulseaforth6930 Ай бұрын
Builder installed it, or a wannabe. They’ve probably got a load of NICEIC stickers amongst their trowels.
@BULLEAD
@BULLEAD 5 ай бұрын
Outgoing circuit not connected correctly into the mcb. My guess before watching.
@BULLEAD
@BULLEAD 5 ай бұрын
Bad guess
@JohnDop
@JohnDop 5 ай бұрын
Was worth a try@@BULLEAD
@ashleybignell2366
@ashleybignell2366 5 ай бұрын
wait till it happens again..... you know she made the kitchen light switching up.
@93nathancurly
@93nathancurly 5 ай бұрын
Ashley get a life!!
@abdulseaforth6930
@abdulseaforth6930 Ай бұрын
A tad harsh- probably was confused
@MichaellKai
@MichaellKai 5 ай бұрын
Hey Delroy i sometimes hear your breathing louder than the voice of the client. You’ve been to the doktors with that ? Just worried thats all .
@christopherkingston9601
@christopherkingston9601 5 ай бұрын
I noticed too. Hope you ok delroy.
@Mainly_Electrical
@Mainly_Electrical 5 ай бұрын
He's confused
@Vijaysingh-zp1ql
@Vijaysingh-zp1ql 5 ай бұрын
Lineman from in 10 years experience HT 11kv 33kv LT line transformer housewiring from India
@tobiaszkucharczyk8595
@tobiaszkucharczyk8595 5 ай бұрын
Too much power consumption Too many devices at the same time
@jameshansing5396
@jameshansing5396 5 ай бұрын
or just a dodge device, hence it was the RCD not an overload......
@grannywaffle
@grannywaffle 5 ай бұрын
Don't think so as she said it tripped whilst she was out, so hardly any load on the circuits most likely. Sounded like a pump firing up when he turned the loft RCD on. That would be my first port of call, and obviously informing them that an RCD downstream of an RCD is asking for issues. Then the wylex breaker needs sorting in the MK Board, just my 2p!
@electrickal1
@electrickal1 5 ай бұрын
Spot on. Tuppence well spent. @@grannywaffle
@Vijaysingh-zp1ql
@Vijaysingh-zp1ql 5 ай бұрын
Country name
@TristanBuckley
@TristanBuckley 5 ай бұрын
London, UK
@albertharmon2738
@albertharmon2738 5 ай бұрын
Kenny Rogers or Dolly Parton
@duzaliteraf7373
@duzaliteraf7373 5 ай бұрын
1 second ago No views No comments No likes I'm first.
@crabby445
@crabby445 5 ай бұрын
Customer: "I think the last ELECTRICIAN made a mistake"
26:03
Eastway Electrical
Рет қаралды 28 М.
FOOTBALL WITH PLAY BUTTONS ▶️ #roadto100m
00:29
Celine Dept
Рет қаралды 73 МЛН
Sigma Girl Education #sigma #viral #comedy
00:16
CRAZY GREAPA
Рет қаралды 65 МЛН
Ну Лилит))) прода в онк: завидные котики
00:51
How I prepare to meet the brothers Mbappé.. 🙈 @KylianMbappe
00:17
Celine Dept
Рет қаралды 50 МЛН
WORST DIY ELECTRICS I'VE EVER SEEN! 🤯
22:52
Artisan Electrics
Рет қаралды 639 М.
HAD TO STOP THE APPRENTICE - FIRST BOARD SWAP
15:55
Bright Spark Electrical (midlands)
Рет қаралды 1,8 М.
Electrical fault finding on a BODGE job
16:09
Eastway Electrical
Рет қаралды 14 М.
Electrician's Job In A Pub Goes Wrong...
17:42
Eastway Electrical
Рет қаралды 16 М.
Installing An Indra Charger With No Driveway!!
20:50
SOTA Electrical
Рет қаралды 246 М.
🤦🏿‍♂️ I Thought This Was Going To Be A Simple Job...
22:06
Eastway Electrical
Рет қаралды 15 М.
FOOTBALL WITH PLAY BUTTONS ▶️ #roadto100m
00:29
Celine Dept
Рет қаралды 73 МЛН