In the last video we took a deep dive into Surge Protection, today let's install 'em! Watch as Dustin installs two different styles of Type 1, Whole-Home surge protectors... Plus the how, why, and where of it all.
SPONSOR: Schneider Electric
homedepot.sjv.io/c/1240960/96...
👾🤖PRACTICE EXAMS🤖👾
www.electricianu.com/practice...
😎👕MERCH👕😎
www.electricianu.com/merchandise
📲👥SOCIALS👥📲
Instagram - / electrician_u
Discord - / discord
Facebook Page - / theelectricianu
Facebook Group - bit.ly/2tz7eQh
TikTok - / electricianu
Reddit- / electricianu
SPDs? You should get that checked out.
These days our homes seem to be spilling over with new technology and sensitive electronics, thus the surges of yesterday are only getting more and more costly. Most homeowners blame lightning for the majority of electrical surge damage to their home... but they're being a bit misled. These voltage abnormalities more commonly come from large appliances in our homes (ACs, furnaces, air compressors etc.), rarely by lightning or changes to the power grid. Surges shorten the life of sensitive electronics, the larger ones causing catastrophic damage to a homes electrical system. Surge Protection Devices or (SPDs) are devices installed at electrical services, branch circuits, or equipment that help protect against these sudden spikes in voltage, using special resistors to “sense” when higher-than-normal voltage is produced then immediately act to redirect voltage away from your electrical system. It's important to note that surge protectors do not protect against lightning strikes to the home or building itself, that would be a lightning protection system which is something completely different, so get that out of your head right meow. To learn more about surges and how surge protection works, go check out Dustin’s deep dive into surge protection -- • SURGE PROTECTORS (SPDs...
Installation
In Dustin's video you will see two different styles of Type 1 “whole home” Surge protection, the first being the snap-in, plug-on neutral style with no leads. This is a newer Square D design that only works with the corresponding QO plug-on-neutral panels. Not only is this style super-sleek and convenient for the installer, but if installed correctly is as close to line as physically possible, meaning its rated efficacy is near 100%. Simply save two breaker spaces of the breaker bus and snap in the surge protector, the green LED light should come on indicating that it's functioning and ready for surges.... and you're done! Simple as apple pie and ice cream.
The second style is intended for more universal use, designed to be mounted to the exterior of any make and model of panel with a threaded hub and lock ring attachment that fits into a ½ inch knock-out at either the bottom or the side of a panel. While this Type 1 is rated for use without an overcurrent protection device, for proper installation it is easiest to land the leads into a breaker that is installed at the nearest space possible to keep the leads short. If the panel being worked on has the option, this specific SPD is also rated to be directly wired to the phase bus mounting screws. When installing this style of SPD it is crucial to keep the leads as short as possible because with every foot of wire lead, 160 more volts is allowed to pass through to the load you’re trying to protect in the event of a surge.
For the full article visit:
electricianu.com/video/how-to-...
Stay safe out there! Love from the ATX
#surgeprotector #surgeprotection #lightingprotection
--
Subscribe - kzfaq.info...
IF YOU ENJOY THESE VIDEOS PLEASE SUBSCRIBE AND "LIKE" THEM ABOVE. ALSO CHECK OUT THE ELECTRICIAN U PODCAST ON ITUNES AND SPOTIFY!!

Пікірлер: 219
@Mr._Krabs
@Mr._Krabs 3 жыл бұрын
Became an electrician watching you. Im on day 94 and they call me the foreman already. Got to thank you for that. Knowledge is everything!
@gm8507
@gm8507 Жыл бұрын
They are probably talking shit to you Mr. Foreman
@dccrazy527
@dccrazy527 3 жыл бұрын
I’ve been helping a friend on mine in the electrical trade. I been in the crawlspaces and attics, but i LOVE this field of trade. I don’t understand most of it yet but I’m getting my grip on it all. We were just at a duplex changing the plugs and feeding new wires to the panel. He showed me once how to take apart the panel, to put a new one in, and put it back together, and I did it with him only explaining it once to me. He’s the best guy to learn from in the electrical trade and I can’t wait to take notes from you as well!
@UpperAquatics
@UpperAquatics 3 жыл бұрын
I'm an aspiring electrician and I really appreciate these videos. I sent you 5 BAT for helping me out. Its awesome to see verified creators out there! Keep up the good work
@Coldrew1111
@Coldrew1111 Жыл бұрын
Hats off to video and professional constructive information. Operating Engineer for 40 yrs... We never know it all Constant check and recheck...Double redundancy.. Smart simple, read all warranties so important..new devices coming out all the time...your videos are so on point. Your site always gives me a good operational Bullet points to help customers understand What equipment will and will not do.. Love how the neighbors say, I watched electrician or HVAC guy...now i can do it...LOL So thanks again for having a truly helpful and safety oriented video... Have to stay up with the times..I help a lot of seniors and always double check my knowledge to protect them and myself.. Drew
@wirefeed3419
@wirefeed3419 2 жыл бұрын
It is excellent to see you talking about Reading the manufactures Installation instructions, something so basic yet can make a huge difference in installation and operation. The instructions are not just paper in the box, the manufacture had to spend a lot of money in providing the very specific information not for but as Part Of the Certification and Approval process. Having been a trades person for almost 40 years, 15 years as an inspector I can say no less than 90 % of every rejection could easily have been avoided by simply following the direction wording of the manufactures installation instructions. It takes 2-5 minutes to read and know yet time after time the instructions are found in perfect condition folded up in the bottom of the equipment or garbage bin. Doing a job twice no matter how basic always takes longer than 5 minutes.
@RogerWakefield
@RogerWakefield 3 жыл бұрын
Great content as always! Love your channel brother!!!
@turtleshellsman3230
@turtleshellsman3230 3 жыл бұрын
Bro I love both y’all’s channels. You guys are amazing teachers and I truly appreciate the knowledge you guys share
@bloodsongsToolreviews
@bloodsongsToolreviews 3 жыл бұрын
"What the hell type of Plumber put that together"
@sambromley7394
@sambromley7394 3 жыл бұрын
I knew sooner or later I’d see Roger in these comments!!
@jeffreylonigro1382
@jeffreylonigro1382 2 жыл бұрын
It’s just like plumbing with electrons!
@lemmonproductions6090
@lemmonproductions6090 3 жыл бұрын
Because of you I'm becoming an electrician this coming year
@WyattH
@WyattH 3 жыл бұрын
Same I’m 16 and planning on becoming an electrician
@mattrob15
@mattrob15 3 жыл бұрын
I just completed my first year because of Dustin
@jamess1787
@jamess1787 3 жыл бұрын
I hope your handy work doesn't produce a lot of lemons!
@SuperVstech
@SuperVstech 3 жыл бұрын
Awesome! Electricians need to be passionate about this field. Learning all the time. Not a day job, a lifetime career. And free time as a beginner is nonexistent. Fill it with learning and you will go far.
@jolyonwelsh9834
@jolyonwelsh9834 3 жыл бұрын
It is a very popular trade. The competition will be very stiff depending on what part of the country you are in.
@sir.7421
@sir.7421 3 жыл бұрын
Great advice about reading the warranty and instruction, Reading the instructions sometimes you learn new things about the device. Keep up the good videos my fellow electrical brother
@RE-ee3ud
@RE-ee3ud 3 жыл бұрын
Real good information thanks.
@oliverpineda-mejia6221
@oliverpineda-mejia6221 2 жыл бұрын
This is another exellente video. Thanks for this value Information
@elc2k385
@elc2k385 3 жыл бұрын
I noticed the nice, relaxing background music playing while you installed the SPDs.
@wmcomprev
@wmcomprev 3 жыл бұрын
If these panel surge protector warranties are similar to the warranty on a plug-in surge suppressor, then their warranty is only activated after your homeowner's insurance has paid. So, usually, they don't wind up paying for anything more than your deductible, but that still helps. The homeowner's warranty will pay for a lightning strike, but I'm not sure about a transient surge caused by something else.
@samhitz945
@samhitz945 3 жыл бұрын
Great work bro!! Lots of neat information!
@ElectricianU
@ElectricianU 3 жыл бұрын
Thanks for watching!!
@10Flat
@10Flat 2 жыл бұрын
It’s also sometimes called PEAK through voltage. Where a panel itself may have a withstand rating.
@SuperVstech
@SuperVstech 3 жыл бұрын
Heh, my shop is a former cable company building... The ENTIRE 3ph main panel is fed through MASSIVE surge protection PANEL... looks awesome.
@SuperVstech
@SuperVstech 3 жыл бұрын
If lead length is so critical on bleed through, why, in your main panel don’t you put the ground and neutral in the shortest location? Neutrals and grounds are legal to share in the main panel...
@rafaelangel955
@rafaelangel955 3 жыл бұрын
You're awesome dude thanks so much !!
@Ali-mo5xt
@Ali-mo5xt 3 жыл бұрын
You are always the best Dustin
@ericr2zz
@ericr2zz Жыл бұрын
Thank you Dustin! Love your channel and just subscribed. I'm planning to install this on my main panel (not subpanel). However, I don't have separate neutral and ground bars. Just one bar which has both ground and neutral wires connected to it. Any reason why I can't connect the green and white wires to this one bar? Thank you!
@skyemac8
@skyemac8 3 жыл бұрын
Great that it’s code for new installations now.
@damianmuniz4175
@damianmuniz4175 3 жыл бұрын
Great info love it make a video of colors high and low volts solid I'm in my first year aprrentice for commercial also tips and phone app or books we can carry as reference
@doghouseliver6955
@doghouseliver6955 2 жыл бұрын
Nice vid. I have one installed in my breaker but it is / down on the left side. I am gussing that leaves some things unprotected? If so, is there such a thing s a surge protected shut off box? I have one down at my gate and the opener was k and I REALLY want it protected
@ryanedwards7741
@ryanedwards7741 3 жыл бұрын
why did you install the breaker at the top of the panel when you said lead length should be as short as possible?
@heroknaderi
@heroknaderi 2 жыл бұрын
I enjoyed it. I appreciate it
@matthewkent1865
@matthewkent1865 Жыл бұрын
Is it reasonable to think about putting a rubber grommet on that device to further water-proof it for outdoors or unnecessary? Thanks for your excellent videos and information.
@leemarker1233
@leemarker1233 3 жыл бұрын
Question. What if there is no space left in the combo panel for a surge protector. Can I still install it in the sub panel? Would it still protect the circuits?
@fishwithmetoday7489
@fishwithmetoday7489 2 жыл бұрын
Can you use the plug on neutral style with the ground and neutral bars not bonded? It is the main panel (customer load), but is the second point of disconnect.
@espnocho7904
@espnocho7904 Жыл бұрын
Great video can I install the D Square Q breaker style surge protector on either side of the panel box
@RJ-ej1nr
@RJ-ej1nr 3 жыл бұрын
Did you install the HEPD80 with the indicator light facing the wall? Don't you need to know when the varistor(s) have gotten used up? Also, I now treat SPDs as consumable devices - after a few early ones got used up quickly and some discussions/tests/fixes from the utility, my next one lasted ~5 years. I like and have the QO250PSPD you have for easy replacement, and for additional coverage, I upgraded to a IG2280 which has the consumable SPD varisitors in a modular replacement. Love your channel!
@number1pappy
@number1pappy Жыл бұрын
On the plug in neutral no wire lead type of surge protector, does it matter how close it is to the main wires coming in to box? In other words is it better to install on the top of elecrical box or does it not matter??
@noeleenfalkner4557
@noeleenfalkner4557 3 жыл бұрын
Can you help in a caravan in NZ and the camp ground suffers from spkes or surges and my ceiling lights are being affected any suggestions or if you can help it would be great. I have been looking at ampfibian from Australia but would need to fly there to get it
@steve-o6413
@steve-o6413 3 жыл бұрын
Another great informative video, know your product your installing not just how to install the device...
@MrTrendsetter
@MrTrendsetter Жыл бұрын
are the surge protectors with leads panel specific or can i install any one on any panel as long as i have a spare breaker?
@Whois2440
@Whois2440 3 жыл бұрын
Another great video! Did you end up installing two? The Plug on Neutral and a breaker version? If so, is there benefit to that over just one?
@ElectricianU
@ElectricianU 3 жыл бұрын
I did but just to show the differences between the two, not for extra protection. I'm not sure that having two at the panel would provide any protection above that which is already present with one. I'd imagine so, but I can't guarantee that.
@eerokartiala5957
@eerokartiala5957 2 жыл бұрын
I got the surge protector HEPD80. I see that the wires coming out of it is 14 Gage. Will that be significant for a type one? They seemed a bit small. The wire in your video looks to be 12 Gage.
@adrianstoness3903
@adrianstoness3903 3 жыл бұрын
do these preotec from frequency jumps in ur power?
@keepinitbassyusa
@keepinitbassyusa 3 жыл бұрын
Sir. I want the baddest full home surge protector for a two story home. Which one do you recommend. Price is not a concern.
@davidkirby3667
@davidkirby3667 2 жыл бұрын
When a main power panel does not have any expansion available, can a surge protector be installed on a pigtail with another branch circuit; sharing a single circuit breaker?
@Kief_
@Kief_ 2 жыл бұрын
What would you recommend for a siemens panel? No arc faults
@tinorivera660
@tinorivera660 2 жыл бұрын
Hello 👋🏼 I’m new to your channel, I’m an apprentice and I really enjoyed the video 👍🏼do you edit ✍️ your own content?? Also do you have any advice for new content creator in electrical trade ?? Should I even worry about making content as an apprentice or vlogging the whole journey?
@virgilsmith5792
@virgilsmith5792 5 ай бұрын
is there a video on installing a surge protector at the transfer switch of my home standby generator?
@skawalker35
@skawalker35 Жыл бұрын
I have an 8 space CSED and a subpanel inside. Does it matter which panel the SPD is installed? I'm thinking inside the CSED since that's the closest to the service drop?
@mrjon75
@mrjon75 2 жыл бұрын
How many volts is the surge protector you installed getting to it under normal situation and how is it getting it?
@nusermane1076
@nusermane1076 2 жыл бұрын
Thank you for the good explanation!! But I’ve got a question: If you’re installing a SPD below your panel, does it really matter, where you place the breaker for the SPD? I’m asking because, if you put it up high and you run long wires down to the SPD, it’s the same distance (if measured from the main breaker on the top of the panel) , as if you put the breaker on the bottom of the panel and run short wires. The distance I talk here about means the length of conductors in sum (busbar + wires). Or is it better to mount the breaker on the bottom, since the busbars may have lower impedance than the wires (more crossectional area)? Bests :)
@SwingboyPA
@SwingboyPA Жыл бұрын
It's more important that the lines to ground and neutral are short -that's the priority with placement. And be sure that the panel is well-grounded (I live in an area with old housing stock where a lot of panels are just grounded to the closest water pipe and then jumped at the meter: so if a plumber installs some pex in between those points, there is no longer a serious ground.
@donmoore6931
@donmoore6931 Жыл бұрын
Thanks!
@michaelbatten4703
@michaelbatten4703 3 ай бұрын
I found a Supco SCW Secondary Surge Arrester that was double tapped onto a 2 pole 20 amp breaker. I bought another breaker for it so I would be double tapped. This surge protector doesn’t have a white neutral wire. Should I get a different one or it the surge protector with a ground and two hots okay?
@rsexpres23
@rsexpres23 2 жыл бұрын
I am not a electrician, so my question is I had a house built and I have 2 breaker boxs in the basement and 1 in the garage. So the question is the surge protector without leads, do i have to install in each breaker box? or is it a option for better protection if i do?
@forrbyc1508
@forrbyc1508 2 жыл бұрын
Thanks for all the great videos and info Dustin! I have a quick question… if you have a sub panel does that need it’s own surge protector? One for main panel and one for subpanel? Or will the surge protector on main panel cover both panels?
@tinyb69
@tinyb69 2 жыл бұрын
If it's being fed from your main panel, it will be just fine.
@forrbyc1508
@forrbyc1508 2 жыл бұрын
@@tinyb69 thank you!
@mellovybz302
@mellovybz302 2 жыл бұрын
Hey keep up the good work I am an electrician also all the way from jamaica
@willwilliams7057
@willwilliams7057 Жыл бұрын
The other day, lighting hit a tree in my back yard, or should I say I suspect that is what happen from the bark of the tree being about 60 feet in all directions away from the tree. I had some outlets that don't work now addition to my Mancave recliner chair which doesn't work now. I get it, reasoning of having a whole house surge protector. I have a garage where my woodworking tools are...some are large tools and they cost thousands of $$$. The garage has a sub panel box of the main panel inside the house. Should I have also a surge protector in this box?
@stanleykania7184
@stanleykania7184 Жыл бұрын
Thanks
@erikev
@erikev 9 ай бұрын
The mfg recommendation is to have two single pole breakers, not a ganged dual pole. This is to maintain protection on the second phase if the first phase only is triggered. Also, it is emphasize that the wires should be twisted (to reduce the inductive coupling). It is right there in the installation instructions.
@boardsblades
@boardsblades 3 ай бұрын
I just picked up a HEPD25 and the instructions state "maximum 30a, 120/240 V Two-pole breaker OR 2 adjacent maximum 30a 120/240 V single-pole breakers... "
@wisnoskij
@wisnoskij 2 жыл бұрын
I Am just educating myself on this topic, but my understanding is the anything on the downstream side of the main breaker is type 2???
@echenduconfidence4998
@echenduconfidence4998 3 жыл бұрын
When SPD is installed, do lighting arrestor matters any more.
@morganyoung8272
@morganyoung8272 2 жыл бұрын
After reading on this I think I’m going to hook mine up to the load side of the main breaker feeding my house pannel, would anyone advise against this?
@zx14jeff
@zx14jeff 3 жыл бұрын
What do you think of the new panel and breakers from Leviton the white panels?
@mathman0101
@mathman0101 3 жыл бұрын
The smart center I am gonna be fitting them to my home. They are expensive but the best smart panel on the market at the moment, at least in the USA.
@Dirty_Bear22
@Dirty_Bear22 2 жыл бұрын
This seems like a type 2 spd, type 1 goes before your electrical meter?
@bruceanderson9461
@bruceanderson9461 2 жыл бұрын
If your panel is full of breakers can you add the surge protector leads to an existing 240 20amp breaker?
@davidsine4390
@davidsine4390 2 жыл бұрын
Great question. That's what I want to know.
@powerstrokeful
@powerstrokeful 8 ай бұрын
Good question I can’t see why not interested in a detailed answer
@goaliedude32
@goaliedude32 3 жыл бұрын
If only I were this early to work, I wouldn't get fired
@guillermoparedes6450
@guillermoparedes6450 3 жыл бұрын
Was that a whole house surge protector? Does that mean I wouldn't have to hook up my expensive equipment like a computer or big screen t.v to a wall plugged in surge protector.
@jragadio
@jragadio 3 жыл бұрын
With the let through voltage, why not install the breaker at the bottom of the panel so that your leads don’t need to run the entire length of the panel to the top where your 2 pole breaker is? It seems as though he leads could be way shorter that way.
@Layarion
@Layarion 2 жыл бұрын
even so, it only protects that one leg right?
@InfoOnly2U
@InfoOnly2U 2 жыл бұрын
You have to install the surge protection bat the top.
@jragadio
@jragadio 2 жыл бұрын
@@Layarion no, it protects both legs since it’s on a double pole breaker.
@sbuckman884
@sbuckman884 2 жыл бұрын
Only had 1 slot left in the breaker box so used a 20/20 CH twin circuit breaker that matched my other breakers. Didn't get a light on the SPD when i set the breaker to on. Also the breaker on opposite leg tripped. Clearly I set something up wrong. Any ideas? Thanks.
@josephwarner6026
@josephwarner6026 Жыл бұрын
a 1 slot tandem breaker gives the same phase to both circuits. You can't make 240 volts out of one. The voltage between the two screws is 0. A two-slot breaker would be on two different phases and have 240 volts between the two screws. The SPD is powered off 240v and you were feeding it 0.
@PrivateUser1
@PrivateUser1 3 жыл бұрын
Does the location really matter that the SPD is as close as possible to the main? I’ve read conflicting thoughts on this. I had the homeline plug on version but it only fit at the bottom where the panel accepted tandem breakers. Does it matter? I see you added multiple SPD is one better than the other or can you put more than one also?
@Conan-dd9qt
@Conan-dd9qt 3 жыл бұрын
Yeah same to me... and Im confused why he put the breaker in the upper part wherein he can also put it in the last slot to maximize the protection... he said that the leads must not be longer or it will still send some voltage in the equipment...
@adamCRALLE
@adamCRALLE 7 ай бұрын
Damn good video
@feddy11100
@feddy11100 2 жыл бұрын
Just came from the other video and wanted to see how difficult this is gonna be. Edit- So would you recommend the breaker style over the wire-in type? You seemed to imply that at the beginning of the video.
@SwingboyPA
@SwingboyPA Жыл бұрын
Yeah; I'd like to know why too...
@christisking9773
@christisking9773 2 жыл бұрын
Can I ask why u didn't put breaker all way at bottom? For sake of neatness that u didn't have 10 empties and then a breaker by itself at bottom?
@walterochoa3826
@walterochoa3826 Жыл бұрын
Great video. How much does it cost to do that??
@mackdraper7464
@mackdraper7464 2 ай бұрын
Came across today, DTK 3 wire (black) secondary surge double tapped into a 60A and a 15A, my thoughts, it cant be proper/safe.
@TheWilferch
@TheWilferch 4 ай бұрын
Some comments on lead length. Yes.... correct...the longer the leads the worse your level of protection. There are industry papers that say if you "twist" your lead wires, at 1 twist/inch of lead length, you greatly improve the impedence to the point of nearing the lab test leads used when measuring VPR, ( 6" long in lab)....and also this---> if you can't twist 10 AWG wire easily you get ALMOST the same impedence improvement when the leads are parallel but tightly TOUCHING one another...like when using zip ties, tightly.Greatly improves the pass-through limit.
@connorbutler4085
@connorbutler4085 Жыл бұрын
When installing a surge protector at the main panel, because the neutral and grounds are bonded together already does that mean that you can wire the ground and neutral wires next to each other on the same bus bar? Or do you still need to wire the ground and neutral to their own bars as if they weren't bonded?
@TheWilferch
@TheWilferch 4 ай бұрын
A main panel...where neutral and ground are "connected" ( bridged...bonded)....you can land neutral and ground on either. For "eye-appeal" and a cleaner "look"...a lot of the more careful installs place all grounds on one bus and all neutrals on the other....but it's not necessary. CAVEAT....keeping it separate IS critical for sub-panels where the neutral and ground busses are NOT connected, but kept separate.
@dereksmith5019
@dereksmith5019 2 жыл бұрын
SO , i install a surge protector and the green lights come on . A month later i check the protector and the lights are red . What does that mean , and what do i do about that ?
@carterbarns843
@carterbarns843 3 жыл бұрын
Speaking of reading the warranty wording, I was reading the warranty for the ultra surge by Eaton. It covers 108,000 amps. And they say they warranty up to $75,000 of connected equipment. HOWEVER. If you read carefully, they say they do not cover acts of god, example, lightning. Why would a surge protector not cover lightning? I understand it isn’t going to completely protect against lightning, that’s not it’s primary function, but that seems kinda off to me and off putting to the customers I install these for. Any thoughts?
@Kiddro22
@Kiddro22 Жыл бұрын
So you basically have double back up coverage from what I’m looking at?
@tomcrosby25
@tomcrosby25 Жыл бұрын
Is there a particular reason you added a second Type 1 protector?
@leibynunez675
@leibynunez675 3 жыл бұрын
@electricianU No apprenticeship available?
@nakayle
@nakayle 2 ай бұрын
If short leads are important why didn't you connect it to a breaker at the bottom where the protector is?
@ramirofaldas9696
@ramirofaldas9696 Жыл бұрын
Sir, i'm from Philippines I get really amazed than here in our country fewer stalled SPD
@picturetaker777
@picturetaker777 2 жыл бұрын
Would you suggest a type 1 and type 2 in the same panel? Not much extra cost - is there added benefit?
@ElectricianU
@ElectricianU 2 жыл бұрын
Type 2 is usually good enough. Type 1 can be a bit cost prohibitive for most. But more is better than none at all.
@janardan7
@janardan7 3 жыл бұрын
I have no more space in my main electrical panel. I do have a sub panel that has open slots. This is another room so I can not move the circuits from main panel to sub panel. Can a whole house surge protector be installed in sub panel and still be effective?
@ElectricianU
@ElectricianU 3 жыл бұрын
It needs to be at the main at the service to be effective as this is the point where your neutral and ground are bonded. Your subpanels are not bonded, and that's on purpose. If you put one of these in a subpanel, the surge would have a long distance to travel to dissipate back to earth so it would most likely do a poor job of dissipating that voltage spike once it finally travels back through neutral to ground because of the added impedance of the length of the neutral conductor between the main panel and sub panel. Also, the HEPD80 model can be installed on the lugs where the main breaker attaches to the bus - since it is a type 1 SPD it has it's own overcurrent protection built in, thus it does not need to be protected by a breaker. This means you can still put one on your main service panel. =) Just read all the instructions about lead length before you do.
@janardan7
@janardan7 3 жыл бұрын
That was very helpful and clear, thanks you
@kylemiller7468
@kylemiller7468 2 жыл бұрын
@@ElectricianU What about a transfer switch scenario. I have a generac service rated ATS outside with a sub panel in the basement. There aren't any breaker positions in the ATS or any tabs to wire off the load side lugs. Would you use a flat connector and add them behind the L1 and L2 cables on the load side rather than adding to the sub panel?
@jorgeeltoritoperez7238
@jorgeeltoritoperez7238 Жыл бұрын
How much should I charge to install one ?
@mathman0101
@mathman0101 3 жыл бұрын
Dustin you need to do a podcast with Uk electrician Nick Bundy, very similar outlook.
@googleantispy3850
@googleantispy3850 3 жыл бұрын
Oops. At 2:23 you mention "two phases". You mean the two legs of //single phase// split 220, correct? Or did I miss something?
@donski1519
@donski1519 3 жыл бұрын
Yeah there's no such thing as 220 volts in America. He had to mean split phase not 2 phase because there's only single phase ran to residential houses.
@petercampbell4220
@petercampbell4220 2 жыл бұрын
Nothing protects from a direct lighting strike. But those are very rare, and usually involes putting out fires.
@jonathan3518
@jonathan3518 3 жыл бұрын
Would a type two spd reduce LED Flickering with load changes in a house?
@jakesully5402
@jakesully5402 3 жыл бұрын
I’m not certain, but my gut feeling is no it won’t reduce it. The diodes stay closed with such low voltage that I don’t feel load changes would cause the flickering. LED is sometimes just really weird, probably because of all the electronics in the driver. I have a SPD on my panel and in my own house I’ve seen simple A19 style LED bulbs stay glowing very dim, even with the switch turned off (no dimmer, just a switch). Thought I had possibly touched neutral to ground inside the octagon, or something like that. It turned out to be something in the bulb. I Switched out the bulb for another and problem went away. Also tried suspect bulb in another location and it still stayed dim.
@oldgringo66
@oldgringo66 3 жыл бұрын
@@jakesully5402 LED bulbs can do weird things. When wired in parallel one bad bulb can cause all kinds of problems. Such as you described.
@kudohits2924
@kudohits2924 2 жыл бұрын
What if I don't have neutral in my system can I still use this brand?
@ElectricianU
@ElectricianU 2 жыл бұрын
Only if it is listed that way or can function that way and it is explicitly stated by the maker that it can be used that way. Otherwise, no.
@chrisdevine9256
@chrisdevine9256 3 жыл бұрын
What are their lifespan? Assuming no major overvoltages, how offer should an spd be replaced? For example, mine is 22 years old. Should I replace it because of age?
@jamess1787
@jamess1787 3 жыл бұрын
It should have a surge rating.... But like all equipment I've used: nothing actually has a counter so you never know when to replace the stupid thing.
@neilbrookins8428
@neilbrookins8428 3 жыл бұрын
@@jamess1787 mine has two green lights. The manual says to replace it when the light goes out. But there is no specific time limit.
@jamess1787
@jamess1787 3 жыл бұрын
@@neilbrookins8428 good to know. Power surge strips sure, but anything else.... I've installed lightning arrestors and other surge protectors in substation facilities for telecom equipment: I've never seen even a light on them. When they go bang is when they tell you they need to be replaced. I hardly believe that a MFG will give you 50,000 in 10 years after their warranty period expires for a surge bar. Seems like a a decision no CFO would make.
@thomashybiske5399
@thomashybiske5399 3 жыл бұрын
A suppressor like the Square D HEPD80 will take repeated hits that are somewhat below its rated maximum without damage to the device. The device will sacrifice itself to suppress surges above the maximum rating and will indicate that it's no longer protecting one of the two phases by extinguishing one or both of the green pilot lights.
@PedroGarcia-zf8zg
@PedroGarcia-zf8zg 3 жыл бұрын
I have a question maybe someone can help me i bought a new electric dryer and the guy that installed it said that my 240 line does not give enough power to run the dryer correctly can someone please help me to see if i can fix the issue
@TheSuraj03
@TheSuraj03 3 жыл бұрын
He may be referring to the main panel and the wire feeding power to it, if your service was installed a long time ago, it is probably rated for like 100amp and is already maxed out in terms of capacity.. It may need to be upgraded in order to supply power to your dryer safely.
@ZiggyTheHamster
@ZiggyTheHamster 3 жыл бұрын
The dryer installer is probably not an electrician or even familiar with electrical work - someone familiar with electrical would have told you something actionable like the outlet not being the proper rating or type. New dryers come with NEMA 14-30 plugs (with 4 prongs), but typically will allow changing to a NEMA 10-30 plug (with 3 prongs) for older installations. The manual will say, and there's a plug conversion kit at your local home center if so. Both of these can deliver 30 amps, so it's not a matter of not having enough power (actually current), but rather not having a dedicated equipment ground. If the dryer instead has a NEMA 14-50 plug, then it requires 40 or 50A, and you'll need to upgrade your dryer's circuit. This would be weird for a dryer, but an electric range would use this type of plug. If you bought the most powerful dryer you could, maybe it requires a 14-50, but otherwise, it should be a 14-30 and probably allows using a 10-30. I can't imagine how it's possible (dryers have been 30A devices forever), but if you have a NEMA 10-20 outlet, you'll also have to upgrade the circuit (because it can only deliver 20A and your dryer needs more). The 10-20 has two angled prongs and one straight prong, and the 10-30 has two angled prongs and one L shaped prong. A 14-30 has a round prong, two straight prongs, and an L-shaped prong. If it's a matter of needing to throw on a 10-30 plug, then I don't know why the installer wouldn't have the ability to do that. It's meant to be easy enough for an end user to do.
@PedroGarcia-zf8zg
@PedroGarcia-zf8zg 3 жыл бұрын
@@ZiggyTheHamster thanks for the info.
@lostsands7587
@lostsands7587 3 жыл бұрын
If you want some more help join the discord, we have a ton of electricians you can pull knowledge from.
@chrisluvsnicole
@chrisluvsnicole 3 жыл бұрын
This was literally my 3rd call today lol 😆... I'm an electrician in Nashville Tennessee. Had to watch this one!
@ElectricianU
@ElectricianU 3 жыл бұрын
Nice!! I actually knew that ahead of time and made this 100% for you, only. IT WORKED! 😎
@sku32956
@sku32956 3 жыл бұрын
I have been doing research on a whole panel surge protection ,I called 5 supple houses none carry them no demand .I called my electrician he says they are worth less lighting does something different every time jumping from cable over to power ,many ways ,The only one he says are good are the ones the power company will install charge a monthly fee .Good luck on a pay out from a warranty claim .
@YehudaKatz1
@YehudaKatz1 3 жыл бұрын
I was always told the surge protector should be as close to the infeed of the panel as possible - if you put it at the bottom in a top-fed panel, you just added an extra foot. Thoughts?
@ElectricianU
@ElectricianU 3 жыл бұрын
Depends on what type you're talking about. They one I have in the top (Plug On Neutral Style) needs to be at the top, closest to the main breaker. But any that have leads (like the HEPD80) just need to have short lead length because of the size of the conductors and the impedance that adds up as the conductors increase in length. The real issue with let-through voltage is from the panel's bus to the device through the leads. The bus offers such less impedance (because of how thick/large of a conductor it is) that anywhere on the bus is generally fine. But when it changes over to the breaker, to screw on terminals, then the path changes to tiny little conductors on their way to the SPD device, this is the weak link in the chain of effectiveness. I've read through all of the literature from both of these products and neither says anything about it needing to be installed near the main, but they all talk about lead length in the warranty section.
@YehudaKatz1
@YehudaKatz1 3 жыл бұрын
@@ElectricianU so if you are installing one with leads at the bottom (as you did), would you want to install the breaker in the bottom-most slot?
@thomashybiske5399
@thomashybiske5399 3 жыл бұрын
When a surge enters through your mains, it propagates down the voltage rails in microseconds. Whether you install the connecting breaker at the top or at the bottom is immaterial. What matters is getting the surge ie. voltage spike off the rails and to ground with as short a lead as possible. Lead length adds inductance. Lightning is not 60Hz, but contains many different and high frequencies. The higher the higher the frequency, the more those long leads look like a big resistor, preventing that portion of the surge from being quenched. So place the surge suppressor anywhere in the panel, but plan its location based on the Neutral and Ground bus bar location so the leads from the suppressor are as short as possible.
@SwingboyPA
@SwingboyPA Жыл бұрын
@@thomashybiske5399 YES. This is important.
@neilbrookins8428
@neilbrookins8428 3 жыл бұрын
It’s interesting you used a 20 amp breaker. I bought a SPD from Eaton and it requires a 50 amp breaker. Seems like a smaller breaker would significantly reduce the surge suppression abilities.
@RJ-ej1nr
@RJ-ej1nr 3 жыл бұрын
The question can also be made for connecting via direct bus wiring as that has no branch circuit breaker at all, and it's load side of the main, not line side which he talked about at 2:08. But SPD performance is not the only factor for that, having to either work hot or turn off the main might be a tradeoff you don't want to make. With the breaker install, HEPD80 instructions say, "connect ... to a maximum of 30A ... breaker". As for why 20A versus 30A, good question, maybe he didn't have 30A handy?
@ElectricianU
@ElectricianU 3 жыл бұрын
The device is what's being protected by the 20amp breaker, not anything else. The only reason for the breaker is to protect the device, it has nothing to do with the surges or the breaker would be nuisance tripping constantly. The manufacturer's sticker says to protect with up to a 2-pole 30 so I'm protecting the device to it's manufacturer nameplate rating, just like we'd do with a motor or appliance. An SPD is not taking the impact of the entire load in a surge, it's balancing the impact through the SPD, the load, and depending on the type of surge - the utility system, and earth.
@neilbrookins8428
@neilbrookins8428 3 жыл бұрын
@@ElectricianU how do you think the SPD is doing it’s protective work? It clearly is taking an abnormally high voltage that it senses on the 1 or 2 hot wires and passing that energy onto the ground wire. This means that the power/energy is indeed passing through the breakers during the brief moment that the surge is occurring. Now, if there are other surge strips at various points of usage, then they are also doing the same thing and passing current from the hot wire to the ground wire throughout the house at various points. But to say that the SPD is not passing the surge energy through the breaker is incorrect. The path order would be breaker to SPD to ground.
@jakesully5402
@jakesully5402 3 жыл бұрын
@@neilbrookins8428 breakers are designed to perform protection under normal use. The surge protection device is considered a load. It consumes energy to simply sit there and await surges. Then it actually (hopefully) performs upon a surge, but the breaker itself does nothing to help absorb the surge. Hope that helps !!!
@Arieeeee
@Arieeeee 2 жыл бұрын
@@neilbrookins8428 Whole House surge protectors handle 40,000 Amps for a split second. If the breaker's purpose had anything to do with protecting the system and not the device, do you really think it would matter if it was 20 amps or 50 amps when we're talking about 40,000 amps?
@eldstgilmorbarboydodellatb4413
@eldstgilmorbarboydodellatb4413 2 жыл бұрын
💚💚💚💚 bookmark/notes: the SC s cig to the work , license plate off car and under box ….ect….tbc….-g-b, bot
@KevinBenecke
@KevinBenecke 2 жыл бұрын
That let through voltage is why you still need the surge protector you have at your devices because they'll catch the let through voltage that is left for further protection at the device(s). One thing you didn't mention in the video is if it matters where the circuit breaker feeding the surge protector goes. Can it go anywhere there is an opening? Or does it go at the top most circuit breaker openings?
@miguelmartinez-kr7ps
@miguelmartinez-kr7ps 2 жыл бұрын
He did mention, he said put it as close as want to reduce the lead lengths. Not sure why he still put his near the the top far from the device after saying that. I guess for aesthetic reasons and maybe the length isn't an issue since it's close already
@gielectric626
@gielectric626 Жыл бұрын
Q: Do these newer surge protectors in homes protect the entire electrical system on the load side of the homes Hydro meter? Even if the panel it’s installed into is a sub panel, or fed from a splitter box and is in parallel with other panels, both fed from a common supply? What about protection of circuits with an AFCI or GFCI breakers or receptacles connected? Thanks for any help you might have.
@jasonbalmaceda6579
@jasonbalmaceda6579 Жыл бұрын
WHAT WOULD KLEIN TOOLS SAY ABOUT YOU USING THE LINEMANS PLIERS AS A HAMMER
@booradlly
@booradlly 3 жыл бұрын
“I’m not going to tap this on The line side of my main breaker, that’s just silly”. Could you explain this, why is that silly ? Wouldn’t that protect against surges from the grid ?
@SwingboyPA
@SwingboyPA Жыл бұрын
Yep. Good question.
@fishyhobby3697
@fishyhobby3697 2 жыл бұрын
Why doesn't square d qo have a dual purpose breaker and surge protector like Siemens? QO top of line.. whatever
@kevindillon358
@kevindillon358 3 жыл бұрын
Disclaimer: I am not an electrician, so I apologize if my terminology is wrong. Question for Dustin or any electricians lurking in the comments: I believe this device works by monitoring line voltage and bleeding it off to neutral if there is an excess (please let me know if that is incorrect). So, since this is the service entrance and neutral and ground are bonded, what is to stop an excessive voltage (lightning strike or whatever) that is bled to neutral by this device from traveling through the neutral bus, through the bonding jumper, through the grounding system and "back-feeding" into the house and potentially the chassis of a metal appliance or something? Is there not potential for getting shocked if you happened to be holding such an appliance when that happened?
@eduardoig17
@eduardoig17 2 жыл бұрын
The music in the background was a little trippy. I thought I was going crazy hearing music that was not there
@crimsontide202
@crimsontide202 6 ай бұрын
You mention to keep the leads as short as possible, but then mention it's ok to place your breaker any place on the buss bar to keep those leads short. Wouldn't the buss bar itself be considered a lead length? In other words, wouldn't it be best to place the breaker as close to the line entrance as possible? Thank you...
How to Replace an Electrical Service Panel (PART 2)
11:07
Electrician U
Рет қаралды 298 М.
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 60 МЛН
ЧУТЬ НЕ УТОНУЛ #shorts
00:27
Паша Осадчий
Рет қаралды 9 МЛН
Protecting My Whole Home From Electrical Surge
23:47
Electric Pro Academy
Рет қаралды 66 М.
Installing an FS140 Siemens Surge Protector
16:56
abrelectric
Рет қаралды 69 М.
Why Do We Bond at the Service Panel and Not a Subpanel?
19:46
Electrician U
Рет қаралды 1,1 МЛН
Arc-Fault, Ground-Fault, and Dual-Function Circuit Breakers Explained
19:51
Why Do We BOND Neutral & Ground in ELECTRICAL SERVICE PANELS?
17:05
Electrician U
Рет қаралды 877 М.