How to run 3 phase motor on single phase supply / single phase to 3 phase converter / 3 phase wiring

  Рет қаралды 242,457

Electro Academy

Electro Academy

2 жыл бұрын

How to run #3_phase_motor with #single_phase_power supply.
Working principle of #3_phase_induction_motor with #single_phase_motor_connection is explained here, with fine animation work.
If you do not have a #single_phase_to_3_phase_converter, this method can be used to run a #3_phase_motor by connecting a matching capacitor as shown in this video.
How ever this method should only be for test purposes of a 3 phase motor or for operating for short periods of time, when 3 phase power is not available.
If you intend to run it for extended periods, it's best to go for a different option with #3_phase_motor_connection.
If this video is helpful, please subscribe the channel.
Thank you.
#capacitor_start_capacitor_run_motor #singlephase_induction_motor #3_phase_wiring #working_principle_of_3_phase_induction_motor #motorstarter #3_phase_to_single_phase_converter #home_wiring #3_phase_wiring
#dol_starter

Пікірлер: 119
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Hi everyone, Just a kind request to the viewers and professionals who can afford to sponsor or fund this channel, mainly for the benefit of the viewers all over the world.🌎🗺✈ It will also definitely be a motivation for me, to continue this channel with good explanatory educational videos for all of you. You can contribute by being a Sponsor of this channel using the following link, patreon.com/ElectroAcademy I made this request six months ago, but no one has come forward to help this channel yet.🤔💔 I know, many have become patrons of entertainment channels mainly, but look forward to seeing at least some supporters who understand the value of an educational channel like this. If you are not willing to visit a particular website for help, please contact me via email, sudarshan78@gmail.com Your kind gesture will be most welcome..!❤❤❤ Thanks and Best regards. Sudarshan, Creator of Electro Academy Channel.
@andersemanuel
@andersemanuel 8 ай бұрын
This was the BEST presentation! With the windings shown it is easy to remember what one is actually doing. Thank you so much ❤❤
@ElectroAcademyEA
@ElectroAcademyEA 8 ай бұрын
Thank you
@selfmade128
@selfmade128 4 ай бұрын
This was the most straightforward and well explained and demonstrated example I have seen on YT! Great work, thanks!
@ElectroAcademyEA
@ElectroAcademyEA 4 ай бұрын
Thank you
@BaljinderSingh-pn1mm
@BaljinderSingh-pn1mm 6 ай бұрын
Sir your explanation way so simple to understand thank you ji 🙏
@ElectroAcademyEA
@ElectroAcademyEA 5 ай бұрын
Thank you
@Walkercolt1
@Walkercolt1 Жыл бұрын
I ran a three phase motor off single phase 220 volt AC (actually 250 volt) for nearly thirty years with a ROTORY contactor that was 1930's vintage, just like the 230 volt 3-phase Westinghouse motor on the Quincy 7 1/2 HP (? maybe 10 HP) two-stage three-cylinder air compressor with a 90 or 110 gallon ASTME tank I got used from a filling station, and sold a few years ago for twenty times what I paid for it to a fiberglas shop, and the buyer thought he STOLE it compared to a new compressor! He'd have to have bought an EPA "compliant" screw compressor new and HAD it installed. HE could install my old Quincy outside in a shed legally. I had never connected the water intercooler, but he did and it was fine. Mine wasn't a delta three-phase, it was a "star" three phase. I DID have to replace the "RUN" capacitor which bulged and leaked from age-a $120 item and while I was into it I replaced the three Vee-belts that were twice my age. It was an induction run repulsion motor that made the electric meter "JERK" violently when each pole of the motor passed, but it will probably run until 2134 when I think it was built in 1934! Yes, a modern Toshiba or Baldor could save some electricity, at the expense of motor-life. You don't get anything for free in life. I used to pump it up to 175 psi and shut it down and "run off the tank" all evening, and sometimes the next day! Oh, yeah, I forgot I had to re-build the second stage compressor early on-the poppet valves stuck and snapped, but I think it was about $50 to fix it from Quincy Parts, and no harder to fix than a lawnmower.
@HappyLacrosse-wg5mq
@HappyLacrosse-wg5mq 4 ай бұрын
Superb and fantastic explanation and can understand very easily. Thank you very much
@ElectroAcademyEA
@ElectroAcademyEA 4 ай бұрын
Thank you 👍
@iikmubarakachmad3054
@iikmubarakachmad3054 11 ай бұрын
Thank You this is very useful knowledge for our needs in the countryside
@ElectroAcademyEA
@ElectroAcademyEA 11 ай бұрын
Thank you
@peterrhodes5663
@peterrhodes5663 11 ай бұрын
I use that basic circuit on my milling machine. What is shown won't have much starting torque, and you'll need a start capacitor of up to 8 times the value of that run one momentarily connected in parallel with it. Also don't expect to get the rated output of the motor, because if you monitor the actual voltage across each phase, only the one between phase and neutral will be correct. One of the others will be higher, and the third lower, and the values will vary, depending on the load that is being driven. The start capacitor has the maximum number of starts/hour written on it. Exceeding that will produce magic smoke, and the necessity for a trip to the capacitor shop. Mine doesn't use that fancy relay, and uses old power factor correction capacitors for the run function.
@ElectroAcademyEA
@ElectroAcademyEA 11 ай бұрын
Thank you
@GroovyG0
@GroovyG0 Жыл бұрын
From 3'54" rubbish - the overload relay does not detect zero current through T3 or anywhere else. The relay is designed to trip when all 3 lines are overloaded. When marginal overcurrent flows only through 2 lines, the thermal conditions for tripping are not satisfied and the relay will not trip. This is why, when using a 3 pole overload relay on a single phase motor, the load current must be taken through all 3 poles as illustrated.
@TheMannuz
@TheMannuz Жыл бұрын
Most overload relays will trip after a while if the load is extremely unbalanced but not overloaded. It could run for several days without any issues but suddenly it will trip.
@donaldroot8035
@donaldroot8035 11 ай бұрын
Some overload relays also include phase loss protection. That is why it is proper to wire it as shown in the video.
@MuttMuttOutdoors
@MuttMuttOutdoors Жыл бұрын
I was once at a shop that a guy had built and setup but only had 220 single phase power available because it was in a residential area. He was able to start and run 3 phase motors on 220 without a capacitor. It's a bit spooky but he would wrap a rope around the pulley and pull start the motor. Once it's running over a certain RPM it will run on 220 single/split phase so pulling the rope like starting a lawn mower would get the RPM up and then throwing the breaker once it was spinning would get it up to about full speed. Also once a single motor was running he was able to take the 3rd leg and use that to start other electrical motors that were 3 phase without using the pull start method. So he had multiple 3 phase motors setup on equipment with a line that linked the 3rd leg of each one together and starting up the shop from cold was a process of starting one motor with a rope and then just throwing the switch on anything else he wanted to run. An added bit of information that I can not confirm was that he would often leave them running for weeks on end even if he wasn't doing anything and his power bill was next to nothing because of the setup. From what I was told the power company came out to check things as his bills were often abnormally low and they thought he was stealing power before the meter somehow. They pulled the meter and it all shut off however. The theory was that because he had a residential meter it wasn't able to handle what he was doing with it and there was some sort of odd ripple feedback or something of that nature which prevented the meter from properly reading the power use because of the 3 phase setup where the 3rd leg was connected between multiple motors. Again I can not confirm this but I don't have any reason to think he was lying about it. I am also doubting that modern meters would have the same issues but the power company opted not to change it because they would have had a major cost to them with little gained return.
@billrobert3226
@billrobert3226 11 ай бұрын
I've heard many happy stories of bad meters giving the customer a discount!
@MuttMuttOutdoors
@MuttMuttOutdoors 11 ай бұрын
@@billrobert3226 Yeah, the old school mechanical ones can be messed up using a big magnet from an old speaker. I am sure the new ones have other things that will cause issue with them as well since they can either use shunts or CT clamps. I personally use CT clamps on my lines for my own personal meter.
@stangatus7550
@stangatus7550 3 ай бұрын
Without a capacitor, this is what you should do. Using a pulley...
@landlordnation
@landlordnation 10 ай бұрын
Good Job! I learned something today!
@ElectroAcademyEA
@ElectroAcademyEA 10 ай бұрын
Thank you
@MervynPartin
@MervynPartin Жыл бұрын
Some 3 phase motors use star/delta starters to achieve soft start and to reduce starting current.
@kalyananaramansantanam6006
@kalyananaramansantanam6006 Жыл бұрын
fantastic, the presentation is really super.
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Thank you
@atseaeto4119
@atseaeto4119 2 жыл бұрын
Thank you!
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Thank you.
@lorenrasmussen338
@lorenrasmussen338 Жыл бұрын
I just use a cheap small single phase motor with a coupler to a larger 3 phase motor as a converter…. Avoids huge current surges and voltage drops. Most power tools can tolerate slight power factor errors
@BaljinderSingh-pn1mm
@BaljinderSingh-pn1mm 6 ай бұрын
I subscribed your channel sir
@ElectroAcademyEA
@ElectroAcademyEA 5 ай бұрын
Thank you
@hughleyton693
@hughleyton693 11 ай бұрын
Yes, correct, you can drive a 3-phase motor using a Capacitor like that. . . . BUT the value of the Capacitor will only be correct for one size of motor and also for only one specific speed or Power output on that motor.. . . These days, it would be better to get a VFD drive unit, which can change single-phase to 3-phase.
@congerthomas1812
@congerthomas1812 Жыл бұрын
Thanks,have heard of it but never seen one.
@fiazshah8289
@fiazshah8289 Ай бұрын
so lovely
@ElectroAcademyEA
@ElectroAcademyEA Ай бұрын
Thank you
@jensschroder8214
@jensschroder8214 Жыл бұрын
also works with split phase 120 volts AC = 240 volts between the two phases instead of the neutral wire.
@Voltechs-Tv
@Voltechs-Tv 11 ай бұрын
Nice bro... Continue good work.. ❤❤
@ElectroAcademyEA
@ElectroAcademyEA 11 ай бұрын
Thank you
@petertyrrell6690
@petertyrrell6690 Жыл бұрын
Great video, thanks. You can start a 3 phase motor connected as you describe by momentarily connecting a heavy wattage resistance (I forget the resistance value) across where you have your capacitor. The motor will run, and is generates the third phase at its unconnected terminal. You now have a rotary converter, and you csn connect a normal 3 phase motor and its control circuit to your rotary converter.
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Thank you
@firealarmapprentice4517
@firealarmapprentice4517 6 ай бұрын
That would not be a good idea.What it sounds like is you are trying to current limit a field with resistance but I can certainly assure you it will not run safely
@petertyrrell6690
@petertyrrell6690 6 ай бұрын
@@firealarmapprentice4517 The resistance is only in circuit for a fraction of a second. Anyway, I have actually used this method of starting a three phase motor, it works, although my motor was under no load. I built a rotary converter.
@firealarmapprentice4517
@firealarmapprentice4517 6 ай бұрын
So if you get a 3phase motor to "spin" on single phase its Great BUT... The single phase is 180 degrees out of phase, but the windings are 120 degrees out of phase. It would be like driving a car where the passenger wheel is turning left and the driver wheel is turning slight right.@@petertyrrell6690
@MBaihaki
@MBaihaki 11 ай бұрын
Yes, this will run as a splt phase motor, but only at a very reduced output.
@sheriffdeen175
@sheriffdeen175 Жыл бұрын
Thankfully sir
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Thank you
@assassinlexx1993
@assassinlexx1993 Жыл бұрын
Vfd is the way to go. You can make a small air compressor produce high volume of air. For air tools.
@bonnylasu7665
@bonnylasu7665 11 ай бұрын
Sir thank you very much. I'm very interested
@ElectroAcademyEA
@ElectroAcademyEA 11 ай бұрын
Thank you
@christianwuethrich2222
@christianwuethrich2222 Жыл бұрын
The problem is that the phase shift between two phases of the 3phase is 120 ° but between the red and the black it is 180 °. So it may turn but it is far from optimal.
@mikechiodetti4482
@mikechiodetti4482 Жыл бұрын
Wow! I'd like to see that.
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Thank you
@MIKSTV-gb6rx
@MIKSTV-gb6rx 3 ай бұрын
thank you and God bless you
@ElectroAcademyEA
@ElectroAcademyEA 3 ай бұрын
Thank you
@ariedekker7350
@ariedekker7350 Жыл бұрын
What I miss are the control of the voltages on the motor terminals. These should be nearly equal across the three points with a running motor.
@tamilamuthanthangavel5568
@tamilamuthanthangavel5568 Жыл бұрын
Excellent sir 5hp motor full load current 9 Amps Please tell me capacitor rating
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
This is 3.8 kW motor. For 230 V AC supply, use 275 Microfarad 440 Volt capacitor. Please do this only for testing purposes. Continuous running is not recommended. Thank you.
@edimichaelchannel1162
@edimichaelchannel1162 11 ай бұрын
this is in my exam on my 5th year in Electrical engineering!😂
@ElectroAcademyEA
@ElectroAcademyEA 11 ай бұрын
Thanks for the comment
@BaljinderSingh-pn1mm
@BaljinderSingh-pn1mm 6 ай бұрын
And also shared your channel
@ElectroAcademyEA
@ElectroAcademyEA 5 ай бұрын
Thank you 👍
@patil9919
@patil9919 Жыл бұрын
👍✌️👌👌👌👌🤗
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Thank you
@davey2k12
@davey2k12 Жыл бұрын
That's same as my old air compressor setup 😂
@paulusgnome
@paulusgnome Жыл бұрын
I have done this before, on a tyre-changing machine, but wouldn't recommend it unless there was no other option. If you can afford it, a small VSD running off the single-phase supply is a much nicer option.
@Jason-wc3fh
@Jason-wc3fh 8 ай бұрын
You mean VFD?
@markmonson573
@markmonson573 8 ай бұрын
@@Jason-wc3fh A Variable Speed Drive aka a Variable Frequency Drive. Same beast by a slightly different name.
@jeremyallard7015
@jeremyallard7015 11 ай бұрын
Gone seem to be the days of swapping two live connections in order to get the motor rotating correctly. Is the single phase operation covered in the IEEE Regs?
@ElectroAcademyEA
@ElectroAcademyEA 11 ай бұрын
Thanks for your comment
@hk4400
@hk4400 Жыл бұрын
👍
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Thank you
@NyambeKennedy-pq3dd
@NyambeKennedy-pq3dd 9 ай бұрын
@ElectroAcademyEA
@ElectroAcademyEA 9 ай бұрын
Thank you
@miker252
@miker252 Жыл бұрын
How does this affect the motor efficiency? Do you need to increase the fuse and overload amp ratings?
@ElectroAcademyEA
@ElectroAcademyEA 11 ай бұрын
We recommed this method for testing purposes of a 3 phase motor and short period running of it. If you intend to run it continuously, best option is to go for a single phase to 3 phase converter.
@firewoodsteel
@firewoodsteel 2 ай бұрын
Would it be better to use 2 phase or 1 line and neutral?
@smithno41
@smithno41 Жыл бұрын
Nowadays you get a VFD that has single phase input and three phase output.
@miker252
@miker252 Жыл бұрын
Plus you have the advantage of a soft start.
@reamer1363
@reamer1363 Жыл бұрын
And watch the lights in the house diminish to nothing LMAO
@randallsnell5767
@randallsnell5767 Жыл бұрын
It may turn, but try to use it.
@Ratridez
@Ratridez 11 ай бұрын
I bought a digital phase converter
@GerardoAlitjr
@GerardoAlitjr 2 күн бұрын
Only if the motor itself is running.
@mithunsarker5090
@mithunsarker5090 Жыл бұрын
In this method, does it possible to continuous run a motor? If possible, what is the maximum motor power???
@jensschroder8214
@jensschroder8214 Жыл бұрын
the engine continues to run with reduced power
@sonnypillarina6056
@sonnypillarina6056 8 ай бұрын
What capasitor i use in 3 phase motor to single phase 220v? 3 phase motor specs.. Y DELTA 346-480/200-280V. 1.40/2.45 A COS♤ 0.80 0.55KW. 3400. 1/min. 60hz
@ivodepin3494
@ivodepin3494 Жыл бұрын
Traduzione in italiano?
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
puoi usare i sottotitoli tradotti. selezionare le impostazioni, contrassegnate come una ruota dentata sullo schermo. quindi seleziona i sottotitoli. quindi seleziona la traduzione automatica. nell'elenco delle lingue selezionare italiano. ottieni i sottotitoli in italiano.
@Ddiizhsjsabv
@Ddiizhsjsabv 4 ай бұрын
Is it starter capacitor or run capacitor?
@ruelaguirre8096
@ruelaguirre8096 3 ай бұрын
I think it is run capacitor..
@hanson8092
@hanson8092 3 ай бұрын
If for start capacitor, its only for single phase motor
@erickmotieri2748
@erickmotieri2748 Жыл бұрын
25hp motor tell me the capacitor rating. Sir
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
25 hp means it is fairly a large motor with 18.5 kW power rating. For testing purposes, you can use 1300 microfarad, 400 V capacitor. Large motors like these, are not recomended for continuous running on load with this method.
@user-vh6qy5yu5h
@user-vh6qy5yu5h 8 ай бұрын
electric chair :-)
@erickmotieri2748
@erickmotieri2748 Жыл бұрын
Add the start, stop button
@cetocoquinto4704
@cetocoquinto4704 Жыл бұрын
Just buy a single phase to 3 phase VFD
@wangaui
@wangaui Жыл бұрын
Spot on
@jacquesdebruyn6748
@jacquesdebruyn6748 Жыл бұрын
Pretty sure I'd be cheaper to just go buy a single phase motor then....
@wangaui
@wangaui Жыл бұрын
@jacquesdebruyn6748 not always practical as single phase motors are larger a larger frame size than 3 phase for the same power output so if its going on a flange it will be to big to fit
@cetocoquinto4704
@cetocoquinto4704 Жыл бұрын
@@wangaui correct..i recently did this on a 3 phase lathe we only have single phase source. If you put single phase motor it will surely not fit hahaha more expensive job.
@mick1gallagher
@mick1gallagher Жыл бұрын
There's a good reason why you have single phase and three phase
@leftylou6070
@leftylou6070 11 ай бұрын
I'm not even gonna watch this and tell you to use a phase converter to operate a 3ph motor with 1ph power.
@ElectroAcademyEA
@ElectroAcademyEA 11 ай бұрын
Thanks for your comment
@HughCStevenson1
@HughCStevenson1 Жыл бұрын
This is apallingly misleading. I am an EE and have designed motor drives. What is the 3 ph voltage L-L? What is the single phase voltage L-N? How much power can you expect from the 3 ph motor? (not much!). How much starting torque, for a compressor, say (a common 3 ph application). Basically so simplistic as to be worthless and potentially dangerous. And why the speech synthesis? Struggled with microfarad!
@pauljanssen7594
@pauljanssen7594 Жыл бұрын
This will not startup of 3-phase motor under load cheapest way of doing called a pony motor
@williamfowler616
@williamfowler616 Жыл бұрын
All motors are three phase, the reason for capacitors.
@user-so3vf7rg8d
@user-so3vf7rg8d 5 ай бұрын
Connecting single phase to a 3 phase motor. That motor will loose 30% of its efficiency.
@timh.2137
@timh.2137 11 ай бұрын
Could you have possibly made this any more confusing?
@ElectroAcademyEA
@ElectroAcademyEA 11 ай бұрын
Thanks for your comment
@bahn5ee
@bahn5ee Жыл бұрын
Sorry but this concept is kind of nonsense, it wouldn't even turn over. Just use single phase motor, is more efficient. By the way you cannot start 3 phase motor without star delta switch unless you run it just with star connection with less power.
@Henning_S.
@Henning_S. Жыл бұрын
@bahn5ee you can also start 3 phase motors in delta configuration but they draw a lot of current so you do it only with small motors. Here in Germany you have to use a star-delta switch for motors above 6kW to avoid a voltage drop in the local energy grid. So your neighbors don't notice their lights getting dim for a split second while you are starting the motor...
@khokonpiru4552
@khokonpiru4552 11 ай бұрын
Fake
@ElectroAcademyEA
@ElectroAcademyEA 11 ай бұрын
Thanks for your comment
@ptv1250
@ptv1250 5 ай бұрын
Can you help with diagram on how to connect 1 phase 240v motor with two capacitors and reverse?
@wasimedoo7994
@wasimedoo7994 Жыл бұрын
What is the biggest size of motor can run single phase and you were saying 70 uf capacitor for 1kw so 3kw by 70 with be 210uf am I correct thanks please let me know
@Henning_S.
@Henning_S. Жыл бұрын
Yes it will work for a 3kW Motor, but not for continuous operation, it will get pretty warm... It will also have a relatively low torque when starting and less power output overall. So it is no replacement for 3phase power, it will work for small motors with no load at startup and manually variable load at operation, but not for most motors with a fixed load... So for example you can use it to power a bench grinder, but probably not for an air compressor or pressure washer ... If you don't want to lose power, the better option is to buy a VFD if you just have 1-2 3phase motors. If you have multiple motors it may be cheaper to buy a rotary converter... Of course, if you live in Europe the cheapest option is to just install a 3phase outlet (CEE), basically every domestic household already has 3phase power...
I Can't Believe We Did This...
00:38
Stokes Twins
Рет қаралды 116 МЛН
Now THIS is entertainment! 🤣
00:59
America's Got Talent
Рет қаралды 33 МЛН
Sizing a capacitor for PF correction
36:54
Serge Levesque
Рет қаралды 35 М.
Connecting a 3 phase motor with 1 phase Power with Diagram
6:56
Overcurrent, Overload, Short Circuit, and Ground Fault
6:54
Dave Gordon
Рет қаралды 825 М.
How 3 Phase Transformers Work - why we need them
24:24
The Engineering Mindset
Рет қаралды 450 М.
Understanding STAR-DELTA Starter !
6:05
Lesics
Рет қаралды 8 МЛН
Star Delta Starter Power wiring Explained Practically by @TheElectricalGuy
13:13
How To Convert DC to AC | Direct current Inverting | 3D Animation
9:38
How to run three phase motor with single phase Supply | Easy Explanation with Animation
3:01