@arthurcharron2010
@arthurcharron2010 2 жыл бұрын
Good Base Of Knowledge you guys. I really Enjoyed Hearing this
@BuildingPointMANA
@BuildingPointMANA 2 жыл бұрын
Thank you Arthur, there is a lot of content here and we appreciate hearing your feedback, please let us know if there is a topic we have not yet covered that you would like to hear more about and we will create that content as well.
@bwilliams00111
@bwilliams00111 Жыл бұрын
Whats the most accurate way to set up? I always set up right on top of a control point and shoot to another. Accuracy is the most important to me, more important then time.
@danieldanieldadada
@danieldanieldadada 3 ай бұрын
What if it takes a thousand years to be accurate?
@khalidhashemi1181
@khalidhashemi1181 3 жыл бұрын
What's the best way to make secondary control points and what's the best way to make them as accurate as possible so its all accurate
@BuildingPointMANA
@BuildingPointMANA 3 жыл бұрын
Khalid, thank you for this question. There are a few ways honestly but we will share one of our favorite to make them accurate and easy. First of all setup your system on the project or site. Shoot a resection to at least two of your known control points (more if possible) and once you have an acceptable "Setup", use the Measure/Collect mode to mark out and collect your new Building or Secondary Control Points. Use these terms to help differentiate the Site Control Points from the other control points just in case a verification need arises. Upon doing this the point can be named and marked as a Control Point giving the point icon the triangle symbol in the point circle on FieldLink. If you have any follow up questions please let us know.
@khalidhashemi1181
@khalidhashemi1181 3 жыл бұрын
Thanks for replying do i have take face 1 reading and face 2 readings and average the coordinates out? Also when shooting temporary control point what are the best practices to follow for a good and accurate set up. Appreciate your help you guys are great
@yavuzcinar6487
@yavuzcinar6487 3 жыл бұрын
Thanks a lot
@BuildingPointMANA
@BuildingPointMANA 3 жыл бұрын
Thank you, we are happy to hear that this video helped you. Please feel free to let us know if there is another topic you would like for us to cover.
@khalidhashemi1181
@khalidhashemi1181 3 жыл бұрын
Grt vid
@BuildingPointMANA
@BuildingPointMANA 3 жыл бұрын
Thank you, we appreciate hearing that our content is helpful.
Connected Workflow Webinar - Construction Layout, Office to Field and Back-BuildingPoint Mid-America
46:02
BuildingPoint Mid-America & North-Atlantic
Рет қаралды 859
BPMA Webinar  - Trimble Field Link  Software Data Collection with a Robotic Total Station
51:18
BuildingPoint Mid-America & North-Atlantic
Рет қаралды 2,5 М.
Kind Waiter's Gesture to Homeless Boy #shorts
00:32
I migliori trucchetti di Fabiosa
Рет қаралды 12 МЛН
Offset and Elevation Layout with Robotic Total Station
19:59
Ironworker Survey and Layout
Рет қаралды 34 М.
Establishing Control Points ,Traverse
20:49
Finchley College
Рет қаралды 60 М.
Grid or Ground - Trimble software scale factor interpretation
1:01:48
Michael Karavanov
Рет қаралды 2 М.
Total Station Backsight Error
25:21
Surveying With Robert
Рет қаралды 13 М.
Control Point Tutorial: CONTROL POINT AND TOOL LOCATION BEST PRACTICES
18:34
Siteworks SPS930 Total Station Set Up 1
19:38
SITECH Intermountain
Рет қаралды 4,4 М.
Planning Your Survey Control Network
19:14
The 3rd Dimension
Рет қаралды 3 М.
Siteworks Resectioning Arbitrary   SPS930
14:07
SITECH Intermountain
Рет қаралды 1 М.
Should I leveled my total station on next station when traversing?
56:37
Michael Karavanov
Рет қаралды 2,6 М.
Construction Surveying and Site Layout with Robotics Total Stations
49:33