EXTERNAL EARTH FAULT LOOP IMPEDANCE - 3 PHASE SUPPLY - AM2S/E

  Рет қаралды 52,386

eFIXX

eFIXX

2 жыл бұрын

A practical example showing how to test the external earth fault loop impedance for a three-phase supply.
Essential learning for apprentice electricians taking AM2S or AM2E assessment.
Filmed with Eddie Clemmens of Pegasus Electrical during installation of a Schneider Acti 9 distribution board.
=================================
🕐 TIME STAMPS 🕕
================================
================================
📍SUBSCRIBE TO THE CHANNEL eFIXX helps electricians, electrical contractors, building services engineers, and electrical apprentices. Watching our videos, you'll discover new products, explore new applications and find answers to your technical questions. So if you've been on the tools for years or just starting your electrical journey, we'll help you stay up to date with the latest regulations and developments in the electrical industry. hub.efixx.co.uk/youtube-subscr... ================================
📺 NEW TO THE EFIXX CHANNEL Watch our essential videos playlist hub.efixx.co.uk/essentials​
📺 CATCH UP ON THE LATEST VIDEOS hub.efixx.co.uk/latest​
📺 ELECTRICIANS' TOOL REVIEW hub.efixx.co.uk/tools​
========================================
eFIXX - EDDY CURRENT MERCH
Now available from an online retailer that doesn't do next day delivery. www.eddycurrent.store/
========================================
🔴 eFIXX LIVE Join us for our youtube live stream twice a month - features product sneak peeks, challenges, giveaways and live electrical banter.
NEXT STREAM HERE 👉hub.efixx.co.uk/next-live-stream​
Catch up on previous episodes 👉hub.efixx.co.uk/livestream​
================================
🆕 FREE CPD Learn about new applications, regulations and best practices with our FREE CPD modules. - New modules released every month covering everything from surge protection to lighting hub.efixx.co.uk/CPD​
================================
📝 APPRENTICE HUB If you're an electrical apprentice, retraining as an electrician or looking to refresh your knowledge, then please check out our apprentice hub. It contains thousands of multiple-choice questions to help prepare for electrical installation exams. hub.efixx.co.uk/apprentice​
================================
📩 eFIXX NEWSLETTER Sign up to find out about our live events, competitions and product giveaways. www.efixx.co.uk/sign-up​
================================
FOLLOW US on your favourite social networks for behind the scenes action, breaking news and competitions.
🟠 INSTAGRAM hub.efixx.co.uk/Instagram​
🔵 LINKEDIN hub.efixx.co.uk/linkedin​
🟣 FACEBOOK hub.efixx.co.uk/facebook​
🟡TWITTER hub.efixx.co.uk/twitter​
==================================
❌ This content on this channel is for electrical professionals.❌ ==================================
📹 Presented by
Gary Hayers - Editor eFIXX
===================================
#efixx #electricians

Пікірлер: 51
@efixx
@efixx 2 жыл бұрын
More on the Acti 9 distribution board - RCBO's with no fly lead -kzfaq.info/get/bejne/m5tkqMeQqK_adYk.html
@ericthekingthekingtheking4842
@ericthekingthekingtheking4842 2 жыл бұрын
Them linked out earth blocks are a great idea to stop conductors being put back in and out, loose connections and the likes, nice video Gaz
@sugardaddyxxx
@sugardaddyxxx 2 жыл бұрын
I’m taking this guy is new to testing, I was thinking your on the wrong setting, 2 lead high, glad your there to guide him through, keep up the good work as always. 👍🏽
@paulspargo-thompson446
@paulspargo-thompson446 2 жыл бұрын
Great video as usual. Obviously you are a knowledgeable guy. Your poor guy was bricking it.
@DLpTheRockStar
@DLpTheRockStar Жыл бұрын
You can do a 2 lead hi test even though there are rcd’s in the board cause the board is off. This is the second video i’ve seen now you saying this now!
@robertwilliamson3934
@robertwilliamson3934 2 жыл бұрын
Poor Ed looks like a real world spark who would have believed you if you told him it was Friday instead of Wednesday lol
@aaplumbingheating6645
@aaplumbingheating6645 2 жыл бұрын
THANK YOU FOR EXPLAINING ,WILL HELP ME IN MY EXAM|.
@wastemanboss
@wastemanboss 2 жыл бұрын
Those MET bars are good. Any idea where i can get them from
@kingofthetrowel1725
@kingofthetrowel1725 2 жыл бұрын
Nice one gaz 👍👍
@RichardArblaster
@RichardArblaster 2 жыл бұрын
Great video 😎
@SpartanMJO12
@SpartanMJO12 2 жыл бұрын
Didn't expect to see Doncaster Cables - just down the road from me, they are!
@elangor2849
@elangor2849 2 жыл бұрын
I first time seeing that kind of test.
@o04n7h0n90o
@o04n7h0n90o 2 жыл бұрын
Where can you buy those MET blocks and all the labels???
@martinelectrician5637
@martinelectrician5637 2 жыл бұрын
Good video! Megger😍
@sam04019491
@sam04019491 2 жыл бұрын
Where did you get that earth bar from?
@Wroe
@Wroe Ай бұрын
So, what should be done if the reading is above 0.35 ohm? Should we contact the DNO? Would this make MCB's operating devices inoperable?
@KlusterYogo
@KlusterYogo Жыл бұрын
Any idea what brand that MET is? can't find it anywhere!!
@TheManLab7
@TheManLab7 Жыл бұрын
I never realised there were 3 different types of AM2. When I did mine back in day, it was just called AM2. Could somebody tell me the difference between the other 2 different types of AM2?
@gkbailey540
@gkbailey540 Жыл бұрын
AM2 is done by people who have done the electrical route not via an apprenticeship AM2s is for apprentices AM2E is for experienced workers, so they must have worked in the electrical industry for 5 years to be able to do the AM2E
@TheYohtube
@TheYohtube 2 жыл бұрын
3 pole or 4 pole main switch at the DB on a 3 phase installation...worth a discussion in a future video?
@arcadia1701e
@arcadia1701e 2 жыл бұрын
Must be 4 pole unless you have a very specific reason for a 3 pole.
@TheYohtube
@TheYohtube 2 жыл бұрын
Yes I always fit 4 pole but I see many boards with 3 ,pole units fitted.
@SME_Ste
@SME_Ste 2 жыл бұрын
Never seen the point of using a 3 pole isolator personally.
@travoltasbiplane1551
@travoltasbiplane1551 2 жыл бұрын
@@arcadia1701e according to who?
@ELECTRICLIFE4U
@ELECTRICLIFE4U Жыл бұрын
👍👍👍👍👍
@sockitz.splatez
@sockitz.splatez 2 жыл бұрын
👍
@jonerasmus9399
@jonerasmus9399 Жыл бұрын
Awesome video. Is this test usually done within the boundary of property or outside (on the councils side ) , please clarify . Cheers
@ovidiuroman1979
@ovidiuroman1979 Жыл бұрын
AND L-N WHEN WE MUST USE.I HAVE A METREL 3125 MI BT,AND I AM CORIOUS.THANK YOU
@Dog-whisperer7494
@Dog-whisperer7494 2 жыл бұрын
Good job done there , but he did make a view mistakes , so give him a slap on the wrist 😂 ok he did sound a bit nervous . Fantastic video as always Gaz 👍👍❤️
@jamescarver6275
@jamescarver6275 2 жыл бұрын
Probably been doing the job faultlessly for 30 years. Gary comes along and he turns into a nervous wreck!
@jollyfinequality9865
@jollyfinequality9865 2 жыл бұрын
To be fair Sean, you've made a mistake in your comment 'a view mistakes' just goes to show, we all make them 😉 (and that doesn't exclude me) #just saying
@luketaylor2846
@luketaylor2846 Жыл бұрын
Another wanting to know who make the MET's
@abssend11
@abssend11 8 ай бұрын
What about PSSC ? Surely that’s going to be higher than PEFC 😮
@farmersteve129
@farmersteve129 2 жыл бұрын
That earth link bar really ought to be secured with security bits to discourage removal.
@travoltasbiplane1551
@travoltasbiplane1551 2 жыл бұрын
The earthing conductor itself also wouldn't normally be secured with security bits... It will have a label saying don't remove though... There's only so far you can go to keep the terminally stupid stealing oxygen...
@electricalstuff259
@electricalstuff259 2 жыл бұрын
0:20 Ed needs to get himself a bigger pozi...
@piotrlobacz
@piotrlobacz Жыл бұрын
With all this pressure for only skilled people carying out live tests our professional spark who makes final connections doesn't look to be very familiar with basic initial verification stuff. Sure he should be doing this work? Makes me wonder how many new installs initial verification he skipped?😂
@glenwoofit
@glenwoofit 2 жыл бұрын
FAILED. You didn't zero your leads out first... Saying that I'm a Fluke man so not sure if your test gear has 4 wire compensation. With fluke you zero every time Espicaly when doing Ze, PSC, EFLI and every little ohm matters..... I now wait for a scolding about not knowing my test equipment, lol
@Ten_Pence
@Ten_Pence 2 жыл бұрын
you don't null leads on a zs or ze test its not a low ohm reading..
@glenwoofit
@glenwoofit 2 жыл бұрын
@@Ten_Pence Its vitally important on Ze, Zs, PSC to zero your leads as your measuring less than an Ohm for Ze also the reading given during the zeroing will tell you about the condition of your leads. And the connections they are making. Many times I've zeroed the leads and found the zero reading high compared to previous times and I've found I've needed to remedy that before I do the test. If your testing in the hundreds or thousands of Ohms 0.4 Ohm lead resistance doesn't matter but that would make your TNC-S reading 0.75 Ohms therefore you'd think the Ze was too high... I Zero my leads Every time I change the test. And I think that was a common sense requirment on my 2391 Test.
@MT_T991
@MT_T991 2 жыл бұрын
@@glenwoofit not at all as you are measuring at a higher voltage. Most meter won't / can't null on a ze
@Ten_Pence
@Ten_Pence 2 жыл бұрын
@@glenwoofit no you're incorrect.. I've been doing this quite a few years sir... if ever your over your max ze or zs you can certainly check your lead resistance but on this test you don't have to null your leads.. you're just wasting your time... The NICEIC have never pulled me up on testing this way as a QS...
@MT_T991
@MT_T991 2 жыл бұрын
@@Ten_Pence someone needs to consider ohm's law that will clear up his confusion
Bro be careful where you drop the ball  #learnfromkhaby  #comedy
00:19
Khaby. Lame
Рет қаралды 38 МЛН
Did you find it?! 🤔✨✍️ #funnyart
00:11
Artistomg
Рет қаралды 120 МЛН
Are ELECTRIC CAR chargers EASY to install?
5:04
eFIXX
Рет қаралды 60 М.
3 Phase Ze and PFC measurement. Prospective fault current and test sheet input .
15:54
QR code 11 -- Earth fault loop impedence test on a lighting circuit (Zs)
3:40
Power up all cell phones.
0:17
JL FUNNY SHORTS
Рет қаралды 48 МЛН
Дени против умной колонки😁
0:40
Deni & Mani
Рет қаралды 8 МЛН
What percentage of charge is on your phone now? #entertainment
0:14
Apple, как вас уделал Тюменский бренд CaseGuru? Конец удивил #caseguru #кейсгуру #наушники
0:54
CaseGuru / Наушники / Пылесосы / Смарт-часы /
Рет қаралды 4,4 МЛН