Fault finding commercial street lighting columns

  Рет қаралды 50,666

Mike Page

Mike Page

Жыл бұрын

In this video i've been tasked with investigating an unknown fault on a commercial street lighting circuit, which literally tested my fault finding patience!
If you enjoy electrical content please subscribe to the channel and checkout my links below 👇
T R A D I F Y 📘
bit.ly/3plevjV
M Y W E B S I T E ⚡
residualcurrent.com/
M Y L O A D O U T 🛠️
residualcurrent.com/pages/loa...
B I G B O O T S D I S C O U N T 🥾
bigboots.co.uk/?ref=4s3760y77o - Use code RESIDUAL
U N I L I T E D I S C O U N T 🔦
unilite.co.uk/?ref=RESIDUAL - Use code RESIDUAL
J O I N T H E C H A N N E L 🤝
/ @residualcurrent
I N S T A G R A M 📷
/ residualcurrent
T I K T O K ♪
vm.tiktok.com/ZM86U2jjG/
The works carried out in the video and the opinions shared are my own, and not representative of the associates and companies in the video.
This content is purely for entertainment purposes and is in no way a "how to", tutorial or educational video.
Please consult an electrician when dealing with any electrical installations.
#electricianlife #electrical #electricalengineering

Пікірлер: 86
@jackstone7063
@jackstone7063 Жыл бұрын
Brilliant video mate 👍 Your the reason I'm going back to college at 28 to become an electrcian. You enthusiasms for the industry is infectious. Hope the videos keep coming 🙏
@edglue6138
@edglue6138 Жыл бұрын
He’s the man
@terrypark5886
@terrypark5886 Жыл бұрын
Memories, back in 1973 total of 6 x 70w sodium vapour lamps on 6 x lamp posts tripping a D16 amp mcb, time curve 320 amps at 0.4 s. Fault finding first lamp post swa clear, middle lamp post swa clear, final lamp post swa down, trace the fault sodium vapour lamp control gear transformer breaking down. The transformer a short circuit until the magnetic field builds ( inrush current) hence the mcb tripping. 1969 given great tips by a sparks born in the year 1910, first always suspect faulty components, second visual inspect 230/400v ( at the time 240/415 v ) supply cables and terminations, third megger out first, middle and last what ever your testing this save hours running around as a headless chicken. Also had faults caused by tree roots crushing the swa. Ducting collapsed the debris crushing the swa when heavy vehicles driving over the ground. As always great video.
@highgatehandyman6479
@highgatehandyman6479 Жыл бұрын
Love watching real world fault finding. Watching experienced sparkies in real world scenarios. Thanks for making the videos and sharing the knowledge
@peterc3228
@peterc3228 Жыл бұрын
My bet would be water ingress past one of the seals on the lamp lenses, which would cause condensation in the fitting, which would have been getting dried off as the sun heated it through the day, or condensation on the switch gear causing tracking (especially that one with the rusted terminal screw) as your IR readings were rising. Great channel, keep up the good work. All the best, Pete 👍
@three-phase562
@three-phase562 Жыл бұрын
Intermittent faults across long circuits like that are so time consuming. At least you now know to start at the other end of the circuit first if you have to go back. Look forward to more videos in the future👍👍
@wells3815
@wells3815 Жыл бұрын
With the way the fault tracked as you disconnected each leg, sounds like the initial fault might have been false due to isolators being on. Issue with such a long run of columns with no secondary fuses installed could be a fault on any of the luminaires and difficult to find. Noticed the cables coming down didn't have drip loops, if there is moisture getting into the column and into top of isolator could be the potential issue.
@pauliboo2
@pauliboo2 Жыл бұрын
This is a great video, don’t worry too much about what’s good for content, this is showing how daily funding goes for the apprentices watching.
@WillmannElectrical
@WillmannElectrical Жыл бұрын
Man I hate it when your fault finding and the fault disappears, its the weirdest feeling I JUST WANA BLOODY KNOW WHAT IT WAS 😂Cross your fingers and walk away - always good to be back on the tools 🤘
@sergiofernandez3725
@sergiofernandez3725 Жыл бұрын
I enjoyed the content. Good to see you in your element and thriving. I look forward to more videos Mike.
@kevinpearson4505
@kevinpearson4505 Жыл бұрын
Sweet video Mike. Yeah I’ve been sent to many strange street lighting faults. Just a little advice if I may. Though you had control of the circuit in terms of isolation I would also follow the Test before you touch practice. It’s a common standardised requirement on the rail which Ive adopted and practice daily on any electrical enclosures
@George_in_Howden
@George_in_Howden Жыл бұрын
Been retired for a while now I was a spark for just over 50 years the last 10 I worked maintenance in large buildings doing everything from changing a lamp, and running 200A three-phase supplies to large Appliances and High Voltage Switching. Loved working out fault finding. I like your style it reminds me a little of my younger days in contracting. There is nothing to beat using logical reasoning to create a plan instead of going on hunches. I would have split the circuit to narrow down the fault for speed. I also would have done a small schematic for any future problems or checked to see if there were any as-fitted drawings. You are a credit to the trade and a young man with a bright future keep up the good work.
@gedtierney374
@gedtierney374 8 ай бұрын
Agree with splitting circuit. The cutouts in those columns are awkward to work on. The cutouts where the double pole fuse carrier can be removed are much better and make testing the circuit easier.
@Evansallelectrical
@Evansallelectrical Жыл бұрын
Loving these sorts of videos mate, great content. Look forward to more of them! 🤜⚡️
@Sparks1Plumbers0
@Sparks1Plumbers0 Жыл бұрын
My boy... back on the tools. Sweet. 👍 Great little video. Love the fact you've got a camera guy, (is he also helping with the editing?)... so hopefully more content from here on in. Anyway great to see you back. Respect 💪👊
@garethhodson3896
@garethhodson3896 Жыл бұрын
Could it have been a pressure fault on one of the cut outs? A cable may have been trapped and when you removed the cover it was rectified
@julianblake4692
@julianblake4692 Жыл бұрын
Nice to see you back on the tools Mike 👍
@coltonmccarthy4353
@coltonmccarthy4353 Жыл бұрын
Great content, would love more troubleshooting videos
@stevecraft00
@stevecraft00 Жыл бұрын
Weirdest fault we had was in a 16 storey council residential block. A ring main served 16 sockets, one on each floor in the riser cupboards. Insulation resistance was bang down. This circuit also fed TV amps so we were keen to get it back on! We split the circuit but the fault still existed on both sides. It was only when we'd taken every socket off that the fault cleared. Turned out the sockets were too deep for the back boxes and the circuit had been wired in conduit passing through the sockets, so the sockets were pressing on the cables. The sockets were old power breaker rcd sockets which are now obselete and a non standard size. We worked out as a temp fix, plastic single to twin conversion patresses fitted perfectly over the back boxes. Fitted them all but it don't meet the spec for that building as they want it all metal. So the whole circuit is being rewired at some point.
@train4905
@train4905 Жыл бұрын
Well done,young man
@rattlehead85
@rattlehead85 Жыл бұрын
Look forward to more content mate.!! With the turn of the year comes the dreaded water ingress faults. Had loads of them where you turn up to find a breaker off…split circuitry to find no fault on cables. Test, reinstate and they all work to go back the following day to find the mcb off again 🤦🏻‍♂️😂😂. Control gear on the old type son T and MBF fittings can also cause issues which can be very inconsistent. Great stuff 🤘🏼🤘🏼
@Daniel.Dalziel
@Daniel.Dalziel Жыл бұрын
I hate them faults that you that get fixed or disappear whilst tracing it, can never be confident to tell the customer you definitely fixed it. Great video Mike, keep em coming 👌
@corymac
@corymac Жыл бұрын
So sick mannnnn, that cine work 😍
@SultansKitchen1
@SultansKitchen1 Жыл бұрын
Brilliant video mate, prefer these types to be honest. Great content.👍🏼
@seanthespark
@seanthespark Жыл бұрын
Nice to see you back on the tools again, hopefully more to come? 👍
@ashvanbro9329
@ashvanbro9329 Жыл бұрын
Best sparky video I seen in ages mate
@ashvanbro9329
@ashvanbro9329 Жыл бұрын
@@residualcurrent your welcome brother I'm sparky and gas inspector by trade
@adrianraith3831
@adrianraith3831 Жыл бұрын
Lamps on posts can be pretty vulnerable to weather damage (even if they are IP rated); wind can drive water in. One method I've used with some success is to disconnect the lamp at each post (all of them), leaving the cable intact. Test the cable right through, if it's clear then start adding back one light at a time (admittedly it can be time consuming and tedious this way). I've just been tracing a fault from an emergency lighting test, 12 maintained bulkheads over exit doors that "failed a 3hr test", and the supply was from "DB-2-7-4"; the 12 lights were actually 2 circuits of 6 (neither of which were related to DB-2-7-4).
@edglue6138
@edglue6138 Жыл бұрын
Love those disappearing faults. Great vid bro
@Sparkyt552
@Sparkyt552 Жыл бұрын
Bro your content is so sick!im a domestic sparky and I really want to get into commercial!i lm so lost watching your videos because there’s so much more to learn 😅keep up the vids man
@Mike_5
@Mike_5 Жыл бұрын
Great video and the fault is probably caused by smokers told they cannot smoke next to the doors of the building so have found a way to knobble the outside lighting
@ChrisSibley.
@ChrisSibley. Жыл бұрын
I work in streetlighting and the SWA work in those columns were appalling! If i left anything like that at work I'd get the sack!🤣
@MrImATarget
@MrImATarget Жыл бұрын
Interesting video. Always a shame when you can`t put your hand on a definite fault. I don`t like those double pole breakers as we get problems with them quite a lot of the time. I use a telescopic pole with a home made photocell cover made out of a piece of 4" ducting to cover higher up photocells.
@MOTO_LEW
@MOTO_LEW Жыл бұрын
He’s back 🔥🔥🔥🔥
@whatevernamegoeshere3644
@whatevernamegoeshere3644 Жыл бұрын
Life hack: Those lamp posts can fit a 9mm socket most of the time, so give your wrists a holiday and use any driver instead of those garbage cross keys. Some are slightly smaller so keep an 8mm on you or an imperial that's under 9mm. When we had to inspect like 200 of these, they were lifesavers
@jimm533
@jimm533 Жыл бұрын
I've just started 2391 so this video is mint mate 👍
@morganarmstrong967
@morganarmstrong967 Жыл бұрын
That tester looks exactly the same as my Kyoritsu 6516. Does it give a dielectric absorption rating reading when using insulation resistance? There is a table somewhere that tells you what the results mean with regards to drit/water ingress. Even in the case of brittle windings on 3 phase motors etc. Its a super cool function I have used a few times during preventative maintenance to find failing equipment.
@projectp8401
@projectp8401 Жыл бұрын
Nice work guys , wishing to working over there in the UK, I'm currently in the PV solar . If you need a handy man I would love the job and I'm very eager to learn from you the masters of the trade
@JayTheSparky
@JayTheSparky Жыл бұрын
Would enjoy seeing a review of the tester mate. I’m a Kewtech man myself I’ve had my KT64 for about 10 years now! Still going strong and was second hand when I got it! Always calibrates and gives sound readings. I’ve got a Megger 1731 but genuinely prefer my Kewtech so easy to use and navigate.
@JayTheSparky
@JayTheSparky Жыл бұрын
@@residualcurrent Definitely mate, love all the RCD times on one page too so handy 🤜🏻👌🏻
@andyneipert2527
@andyneipert2527 Жыл бұрын
Those are sum cool looking street lights you are working on
@ruhulali8129
@ruhulali8129 Жыл бұрын
Hi mate, were you testing L&N combined to CPC when insulation resistance testing to avoid the lamps in circuit or testing all three combinations but just testing at 240V?.
@ForTheBirbs
@ForTheBirbs Жыл бұрын
Fantastic seeing you back on the tools Mikey and looking so excited! Have a look at Ryan's RSD Electrical YT channel from Glasgow for some shocking street column nightmares.
@ForTheBirbs
@ForTheBirbs Жыл бұрын
Awesome
@siondavies2908
@siondavies2908 Жыл бұрын
Great video Mike. We have all been there with those types of faults that we never find 👍🏼
@malcolmcroll7556
@malcolmcroll7556 Жыл бұрын
i must say you do know your job ,i like what you do down to earth ;;
@TheYohtube
@TheYohtube Жыл бұрын
Been there before, chasing a low IR that eventually disappears, very frustrating.
@mathman0101
@mathman0101 Жыл бұрын
Frustrating I suspect moisture ingress and those covers for the cables don’t look water tight either. Anyway any luck on the boddingtons insulated inspection mirrors are they in stock on loadout?
@stevedebbiemoore
@stevedebbiemoore Жыл бұрын
Nice one, just goes to show that things aren't as straight forward as you think. Imo definitely think it's damp as the IR rises slowly then clears. Compressed cables sometimes give the same thing but the rise is fairly rapid. Also see this in damp motors but a couple of blasts at 1000v generally clears that 😂
@stevedebbiemoore
@stevedebbiemoore Жыл бұрын
@@residualcurrent 😂
@johnhoward2104
@johnhoward2104 Жыл бұрын
I had a similar one. Customer had used an IP rated inline joint to connect an outdoor light. The RCD would occasionally trip. Tested the cct and found an intermittent fault - devils to find when it's in clear mode. Turned out rain water was in the inline joint because he hadn't sealed it properly, and the fault appeared only when the wind blew hard enough to move the joint and short the connections. The frequency of ads is annoying and distracting.
@ionutth4895
@ionutth4895 Жыл бұрын
hey man where do you think i could learn more about electrics to get better? i work as an electrician building panels (not UK) but the school i went to was short and didnt teach a lot, any manuals you would recommend that i can find online? i have tons of manuals that teach formulas and engineering but none that teaches fault finding, all the complete testing procedures EICR and what are they for and so on, for example i was watching artisan electrics a few days ago where they tried to install a TESLA wall battery that needed a secondary TT earth electrode for when main is off and they argued about the section of the PE then read something in a manual they had with schematics and recommandations but i couldnt find such manual online
@rondo122
@rondo122 Жыл бұрын
such good content, perfect reasoning and methodology: it shows you are a very good technician/electrician! thank you for sharing with us!
@markr452
@markr452 Жыл бұрын
Really good 👍
@ShalomBrother
@ShalomBrother Жыл бұрын
Did you go in each lamp first and flick them all off?
@ia4387
@ia4387 Жыл бұрын
Great video here. Could you explain more about how to wire the manual override in a future video please. Keep up the great work.
@user-ln7of9gs4s
@user-ln7of9gs4s Жыл бұрын
Plus one.
@johncanty2847
@johncanty2847 Жыл бұрын
My guess would be moisture in the terminals or maybe a pinched sheathing on a termination? Nice video mate 👍🏼
@jamiesugrimm
@jamiesugrimm Жыл бұрын
pinched sheathing on a termination wouldn't cause a breaker to trip though would it?
@Goodwithwood69
@Goodwithwood69 3 ай бұрын
14:00 made me wince!
@ettselectricalservices9428
@ettselectricalservices9428 Жыл бұрын
Hey Mike…. Nice watch! For future reference standard photocells always fail in the ‘ON’ position 🙂 (But not part night they fail both open and closed…) Keep up the content!! 👌🏼
@ettselectricalservices9428
@ettselectricalservices9428 Жыл бұрын
Surprised the heads are on 32a breakers? 😮
@jamiej779
@jamiej779 Жыл бұрын
Great Vlog mate what make is your orange Hi-Viz and do you sell them ?
@carlgrooby4083
@carlgrooby4083 Жыл бұрын
We’ve all had faults like that with no answer, all you can do is work methodically through
@Ben-zn8pe
@Ben-zn8pe Жыл бұрын
I sometimes use a single straight from the breaker and put it in A1 to override the photocell
@MrWHITTERS8
@MrWHITTERS8 Жыл бұрын
I found the camera settings a bit difficult to watch. When you blur the background, sometimes it was blurring your hand and equipment, other times it was blurring your face. It couldn't see the Impedance readings on the meter. Perhaps try a different video effect.
@crim7ind
@crim7ind Жыл бұрын
What coat is that? Is it worth the purchase?
@tiheneagabriel6548
@tiheneagabriel6548 Жыл бұрын
what is the other key switch doing?
@ethianwebb
@ethianwebb Жыл бұрын
when are you going to restock the veto bags on your shop?
@ethianwebb
@ethianwebb Жыл бұрын
@@residualcurrent it was the VETO PRO PAC TECH PAC Blackout 👍👍
@highgatehandyman6479
@highgatehandyman6479 Жыл бұрын
Nice video.
@stuartthespark
@stuartthespark Жыл бұрын
Did you jump in the picker and do a visual inspection of the lamps, could be a damaged seal.
@stuartthespark
@stuartthespark Жыл бұрын
@@residualcurrent looking forward to follow up, I wonder if the continues IR test, somehow dried out the the fault giving you good readings at the end of the job. You've proven that the cable is ok, terminations are ok'ish. Bet you a klien screwdriver it's a fault on the lamp side, water ingress. Enjoyed your logical approach.
@1992Craigster
@1992Craigster Жыл бұрын
Good Vid Mikey, good to see you getting site work again, where you been hiding? 😁 @rsdelectrial might spot the fault, hes always in lampposts.
@ASour1170
@ASour1170 Жыл бұрын
Nice jacket. Any chance of a link? Would appreciate links to your work fits in future video descriptions😁
@garethhodson3896
@garethhodson3896 Жыл бұрын
Where did you get your jacket from? ❤
@Vblxy7
@Vblxy7 Жыл бұрын
Did you have to go back there?
Жыл бұрын
Good Very good 👍
@skyemac8
@skyemac8 Жыл бұрын
Sometimes just taking it apart then reconnecting is all it needs.
@alaiyahakeem717
@alaiyahakeem717 Жыл бұрын
Wait guys is this where they Always on street light
@brianhewitt8618
@brianhewitt8618 Жыл бұрын
👍
@Si6Si6
@Si6Si6 Жыл бұрын
👍🏻
@zjzozn
@zjzozn Жыл бұрын
⚠️ Complaint: please can you stop making so watchable great vlogs…. I’m trying to get some work done!!! ⚠️🌈🤣
@8skellerns
@8skellerns Жыл бұрын
So many of your fault finding techniques are used in copper telecoms when finding faults in cables through numerous joints. Sadly copper telecoms are a dying career now that fibre is replacing it. :(
@kristiangoransson6104
@kristiangoransson6104 Жыл бұрын
You guys are really spoiled with room in your enclosures, our would most lightly be cramped in one a third of the size.
Commercial electrical fault finding
33:50
Mike Page
Рет қаралды 18 М.
Swapping out an HPS for an LED street light
13:06
Bobsdecline - Lineman blogger
Рет қаралды 31 М.
格斗裁判暴力执法!#fighting #shorts
00:15
武林之巅
Рет қаралды 91 МЛН
СҰЛТАН СҮЛЕЙМАНДАР | bayGUYS
24:46
bayGUYS
Рет қаралды 774 М.
Super sport🤯
00:15
Lexa_Merin
Рет қаралды 20 МЛН
What's in my van 2024? - Electricians Van Tour
25:41
Mike Page
Рет қаралды 10 М.
Revealing costs UK electrics - Pricing a Rewire together
11:06
N Bundy Electrical
Рет қаралды 54 М.
Street Light Panel Wiring fully automatic circuit  #PowerConnection #Controllingcircuit
4:19
RR Tech Guru (Learning Platform)
Рет қаралды 9 М.
Underground cable laying for street light
7:46
Rashid iqubal
Рет қаралды 6 М.
Fault Finding an Electrical Lighting Circuit - Expert Electricians Top Tips
32:39
Does Current Flow Through The Neutral Wire?
7:41
eFIXX
Рет қаралды 321 М.
My first STREET LIGHT change | Nagy Weekly
12:13
Thomas Nagy
Рет қаралды 78 М.
Electrical sub-main installation with the boys
44:14
Mike Page
Рет қаралды 18 М.
5 НЕЛЕГАЛЬНЫХ гаджетов, за которые вас посадят
0:59
Кибер Андерсон
Рет қаралды 941 М.
Will the battery emit smoke if it rotates rapidly?
0:11
Meaningful Cartoons 183
Рет қаралды 1,5 МЛН
wyłącznik
0:50
Panele Fotowoltaiczne
Рет қаралды 23 МЛН