Fixing Ungrounded Outlets by Installing GFCI Outlets- Save THOUSANDS OF DOLLARS

  Рет қаралды 119,205

Morgan Inspection Services

Morgan Inspection Services

3 жыл бұрын

0:01:12 - The Purpose of Grounding
0:03:25 - How to Find the First Outlet in the Chain
0:11:06 - How to Install a GFCI Outlet
This video will show you step-by-step how to replace an ungrounded outlet with a GFCI-protected outlet. Most older homes have two-prong outlets instead of newer, safer three-prong outlets. There are also many older homes where three-prong outlets have been installed in place of the older two-prong outlets. A home’s electrical system in both of these situations is not as safe as newer, modern systems because there is no equipment ground. In this video, I will show you how you can make your home essentially as safe as if it were wired with a three-wire (grounded) system. You can do this at a fraction of the cost of rewiring your home. This video will show you step-by-step how to replace a standard ungrounded outlet with a GFCI-protected outlet. It will also show you how to find the first outlet in a daisy chain so that one GFCI can protect all other outlets downstream.
www.morganinspectionservices....

Пікірлер: 260
@user-if8bt9ts8j
@user-if8bt9ts8j Жыл бұрын
Incredible video! I am using this right now to correct my home built in 1962. No one tells you how to figure out which socket is the first in the chain, this does, which is invaluable! Thanks so much!
@morganinspectionservices3840
@morganinspectionservices3840 Жыл бұрын
Glad it helped
@plausibleg.3170
@plausibleg.3170 3 жыл бұрын
This is by far the best DIY video on the topic. Thanx, so much for your knowledge.
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
You're very welcome!
@JasonJFlippingLife
@JasonJFlippingLife 2 жыл бұрын
Really appreciate you taking the time to do a full explanation and wiring example.
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
You’re welcome. Glad it was helpful.
@Mrscrapiron5
@Mrscrapiron5 3 жыл бұрын
That label "no equipment ground" also needs to go on your GFCI outlet. You didn't point this out when you tested your outlet, but the ground light on your tester did not light because even though you have GFCI protection, that outlet is still ungrounded. So you are protected from electrocution, but sensitive stuff like computers and other electronics are NOT protected from damage due to no ground. Installing these GFCIs is a great way to make an old house a lot safer without spending many thousands of dollars to basically rewire the house (and then replace all the sheetrock and/or paneling you had to wreck to rewire). But it is not the same as having all grounded circuits.
@joerostkowski7313
@joerostkowski7313 2 жыл бұрын
The best way in an old house is to install a gfci breaker on your main panel. There expensive but worth it . Ps who uses power tools on outlets.
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Thanks,
@shockingguy
@shockingguy 2 жыл бұрын
@@joerostkowski7313 So where do you plug them in, your quantum power back
@vincentnguyen1603
@vincentnguyen1603 Жыл бұрын
Are all the outlets in the circuit going to be unprotected from damange to electronics or just the GFCI outlet that he put in the first outlet of the chain?
@tomsko863
@tomsko863 Жыл бұрын
@@vincentnguyen1603 The GFCI Outlet gives the same protection to every outlet away from the circuit breaker box as it has itself. What GFCI checks is to see that the current coming into it (HOT) is equal to the current leaving (NEUTRAL). So if the HOT is bringing in 10amps, but some outlet further up is dumping some amperage into a toddler (for example), the returning current going to the GFCI NEUTRAL will be less than 10 amps (9.95 amps for instance). Since those are not the same, the GFCI will trip.
@jpisty
@jpisty 3 жыл бұрын
This video explained the process way better than those highly funded channels like This Old Home. Thank you
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Thank you
@garycox3205
@garycox3205 2 жыл бұрын
Thanks, your best one to explain how fix that problem, be trying for 3 days .
@israeljo1443
@israeljo1443 3 жыл бұрын
It really help me a lot, now i know where to install the GFCIs - Thank you
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
You're welcome.
@vh448
@vh448 2 жыл бұрын
Great job, clearest explanation of GFCI.
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Thank you. Glad you enjoyed.
@maribelvallejo2008
@maribelvallejo2008 2 жыл бұрын
Thanks guy,very informative, I'm buying a house that is not grounded, and this helps.
@NightWind1157
@NightWind1157 3 жыл бұрын
Thank you so much for this! I purchased my home (built in 1950) last year. While three key outlets for AC and the refrigerator have been rewired with true grounds, there are several 3-prong receptacles in the house that test as not grounded. For the most part just knowing which is which is enough for me, but this is such an easy and inexpensive fix it's now going on my "to do" list!
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Well, I am glad I could help a little bit. It is pretty simple, and it will definitely make your home safer. Good luck with this future project.
@luminousfractal420
@luminousfractal420 Жыл бұрын
Be careful i had the same issue in this property (50's-60's concrete building) turned out there was one of the alternate systems which ruined my computer and multiple apple adapters. My computer died when voltage came through the fake ground in the outlet and found its way to the telegraph pole outside through my computers lan cable. Very fried board. Electrician said it was safe ....safe like this guys thing..wont kill you apparently but will ruin your equipment. Ive found 2 outlets in the whole house that have a true ground and dont return voltage from the negative down the earth cable. Only good for lightbulbs.
@padsgoo
@padsgoo 3 жыл бұрын
Thank you! This video helped me install my gfci correctly.
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Glad it helped!
@drancealot
@drancealot 3 жыл бұрын
Best one on this i've seen so far. thanks!
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Glad you liked it!
@craigbare9792
@craigbare9792 2 жыл бұрын
@@morganinspectionservices3840 444
@genahowe4206
@genahowe4206 3 жыл бұрын
This was incredibly helpful to me. Thank you!
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
I’m glad I was able to help.
@josephharper7601
@josephharper7601 3 жыл бұрын
I saw a video where a guy replaced a 2 prong outlet with a 3 prong outlet, ALL he did was re hook the 2 wires to the new outlet and shoved it back in the box. IS THIS ok or not.
@thelanda1091
@thelanda1091 2 жыл бұрын
Thanks for this video. You just saved me a lot of cash. Wonderful work
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Glad it was helpful.
@davestewart6565
@davestewart6565 2 жыл бұрын
Super helpful, thank you for this!
@igfishing13
@igfishing13 2 жыл бұрын
Thanks much great teacher , just bought a house and really need to know these things
@Gfpm256
@Gfpm256 2 жыл бұрын
Very good on explaining . Thank you.
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Thank you and you’re welcome.
@johnurbanowicz9940
@johnurbanowicz9940 2 жыл бұрын
Thank you and that was very very helpful thank you for sharing with everybody out there 👍👍👍👍👍
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
You are welcome.
@elcubanito001
@elcubanito001 3 жыл бұрын
This is the most comprehensive video i have seen on this topic.
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Thanks. I appreciate the feedback. Hope it helps you.
@elcubanito001
@elcubanito001 3 жыл бұрын
@@morganinspectionservices3840 so what can i do if the house doesn’t have a ground cable in the walls? How to i protect against surge? If the first in the chain is GFCI’d will it shit off and prevent the others in the chain from power surging?
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
@@elcubanito001 First of all, I need to say the GFCI‘s are not designed to prevent or protect against electrical surges. The home grounding system is designed to dissipate electrical surges into the ground. GFCI’s are only designed to protect someone from being electrocuted if there is a ground fault due to a fault or damaged piece of equipment. If you properly install a GFCI-protected receptacle as the first receptacle in the “chain,“ it will protect all other receptacles that are supplied from the GFCI-protected receptacle. All of those receptacles will be protected even if there is no ground wire connected to the receptacles. I hope this answers your question.
@jimgill5706
@jimgill5706 3 жыл бұрын
Good video. Thanks.
@russwelday
@russwelday 3 жыл бұрын
Great video. I learned a lot.
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Glad it was helpful!
@vdsilva6806
@vdsilva6806 2 жыл бұрын
Thanks! Great video. Personally, I would also use a Klein screwdriver to assure that the line and load wires are well tightened.
@themacawbaby2368
@themacawbaby2368 2 жыл бұрын
Thank you so much. Now I can fix my own
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Glad I could help
@bravo3541
@bravo3541 2 жыл бұрын
Good job explaining gfcis
@josegomez534
@josegomez534 Жыл бұрын
Excellent video very well explained thanks. 👍
@morganinspectionservices3840
@morganinspectionservices3840 Жыл бұрын
Thank you.
@williekeener9604
@williekeener9604 3 жыл бұрын
You did a good job of keeping it simple for a diy’er. I wish you had gone a little further toward explaining why this is needed. One commenter mentioned that this does not solved the ungrounded aspect, but you correctly replied that it made it much safer. In my practice, lots of people have not figured out the original purpose of GFCI’s and as a result would be lost the first time that GFCI behind the dresser tripped and the iron didn’t work. Landlords can reduce their liability exposure by installing these. With the GFCI, that dirty or damaged appliance may not be grounded, but it won’t continue to run either. Hope someone saw a way to make the kids rooms safer!
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
I appreciate the feedback. If this video helps to just make one home a little bit safer, it will have been well worth my time.
@surferdude642
@surferdude642 3 жыл бұрын
Nicely done demo and explanation. I have a few comments. Since you have a metal box, wrap electrical tape around screws, other comments have also mentioned this. You need a "no equipment ground" label on the gfci receptacle also. Most importantly, since this room would like have computers, tv, etc. these shock prevention measures will not protect electronic devices. Surge protectors don't work without ground. Please use a manual screwdriver for attaching wires to receptacles. There are so few threads, it takes no time to make a tight connection. Btw most often the screws accept flat, philips, and square drive.
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Thanks for the feedback. You are correct.
@GOESCH77304
@GOESCH77304 2 ай бұрын
Thank you...nice & simple fix. Now go get the cover...lol. Great job. Thanks again
@morganinspectionservices3840
@morganinspectionservices3840 2 ай бұрын
Thanks for the feedback.
@franciscoortiz3575
@franciscoortiz3575 3 жыл бұрын
Great presentation
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Thank you!
@eddiesandoval34
@eddiesandoval34 Жыл бұрын
Thank u. Was wondering how I could. Protect my ungrounded outlets in my 1952 home
@bollmann4580
@bollmann4580 3 жыл бұрын
This video you tube save me a lot of money. Thank you.
@naelair
@naelair 2 жыл бұрын
Thank you!
@mikeray5311
@mikeray5311 Жыл бұрын
A very helpful video.
@morganinspectionservices3840
@morganinspectionservices3840 Жыл бұрын
Thank you for the feedback. Glad it was helpful.
@evrik78
@evrik78 2 жыл бұрын
Great video Mike!
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Thanks
@abrahamvaro5482
@abrahamvaro5482 3 жыл бұрын
Nice video,thanks
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Glad you liked it
@m.cortez6634
@m.cortez6634 3 жыл бұрын
Thank you
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
You're welcome
@whitetiger8652
@whitetiger8652 3 жыл бұрын
Nice job.
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Thanks!
@will2dmax1
@will2dmax1 Жыл бұрын
We have one of these in the bathroom, does that provide ground to everything in there like the vanity lights, plus, everyone of our outlets were replaced with one of these
@unreal2005
@unreal2005 2 жыл бұрын
Noticed there was some shiners poking out from the screws. Would wrapping electrical tape around it fix the issue of accidental wire to wire contact.
@bretmoore6828
@bretmoore6828 2 жыл бұрын
Thanks.
@artcontreras6866
@artcontreras6866 2 ай бұрын
thank you sir !!
@morganinspectionservices3840
@morganinspectionservices3840 2 ай бұрын
Most welcome!
@g-rocks6548
@g-rocks6548 3 жыл бұрын
When inspecting your outlets, always check both receptacles in the duplex. I've had it where the top outlet was correct and then there was a hot/grd reverse on the bottom due to too long terminal screw pigtails.
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Good advice!
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Great advice. Thanks.
@gmarcomontes
@gmarcomontes Жыл бұрын
Nice video, what about when you want to install a motion detection light switch that requires to be grounded?
@morganinspectionservices3840
@morganinspectionservices3840 Жыл бұрын
If something requires grounding, then this method will obviously not work. If the box is metal, and if conduit was used then you can use a pigtail from the receptacle’s ground screw directly to the box to ground it. Otherwise, you have no choice but to run new wire or at least a ground wire from the panel box to the receptacle you need to ground.
@michaelkaiser1864
@michaelkaiser1864 3 жыл бұрын
Thanks for this. FWIW, I always tape the lugs when its all tight. Just paranoid lol.
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Great tip!
@Jorge-Molina
@Jorge-Molina 3 ай бұрын
It is not as safe without grounding, as the GFCI will only trip when a person touches the outlet or connected equipment. On the other hand, with a ground connection, the GFCI cuts off the power one thousand seconds after the bypass occurs through the ground wire. Thus, when the person touches the elements, they will be previously de-energized.
@morganinspectionservices3840
@morganinspectionservices3840 3 ай бұрын
You are 100% correct. It is not as safe as an outlet that is grounded, because power will have already been shut off to a grounded outlet while an outlet protected by a GFCI will not lose power until someone touches it, and creates the “ground fault.” However, an ungrounded outlet protected by a GFCI is MUCH safer than a simple ungrounded outlet.
@humbertosrperez
@humbertosrperez 2 жыл бұрын
Awesome
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Thank you
@craigjackson5492
@craigjackson5492 3 жыл бұрын
protect yourself and your family from electrical hazards
@11ORTIZ11
@11ORTIZ11 3 жыл бұрын
Thanks for the video. The wiring in my house is aluminum, do they make gfci outlets for aluminum like they do ordinary outlets and switches? Thanks!
@billhollin49
@billhollin49 3 жыл бұрын
Suggest contacting a licensed electrician for appropriate corrective measures. There is a way to safely use the aluminum wiring. Each device has to be protected. Do some research. I am not an electrician, but I’m privy to information in my business. Again, contact licensed electrician.
@virtuallyrealistic
@virtuallyrealistic 3 жыл бұрын
Look for outlets and switches that are labeled CU/AL. As it copper (CU) or aluminum. These days lots of devices are labeled for this use.
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
They must be labeled "CU/AL" in order to be used with aluminum wiring.
@peacefrog0521
@peacefrog0521 3 жыл бұрын
@ 7:00 Don’t know if you’re aware, but for “back-stabbed” wires into a receptacle, you don’t necessarily need to cut them to remove them. You can either wiggle them until they come out, or they may be held in place by the screw (even though they are not wrapped around the screw). By removing them in either of these ways, you save yourself from having to lose limited available wire length, and you don’t need to strip (as they will already be stripped). If neither of these is the case, of course, then you’d need to cut. If you manage to get them out just by wiggling, definitely DO NOT just reinsert them. The retention will be very poor. In fact most recommend NOT using these back-stabs at all, unless they are held in place by tightening the screw (rather than just depending on spring force for retention). P.S. I’m also not a licensed electrician. (But I’ve watched plenty of them in KZfaq.)
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
I am aware of that. I was just trying to speed things up a little. I should have at least mentioned that there are various ways to disconnect the wires. Thanks for the feedback.
@donf3739
@donf3739 3 жыл бұрын
The receptacles I have, have a hole next to the back-stab hole that you can push a nail or something into to release the spring. That aside, avoid using those ridiculous back-stab holes at all costs. They're not reliable. One comes loose and everything downstream goes out. They're obviously made for quick, slipshod operations like manufactured housing operations, not for people like us, who have to live with them.
@peacefrog0521
@peacefrog0521 3 жыл бұрын
@@donf3739 Agree 110% on not using the spring-loaded backstabs. I do like what this guy does at 11:35 in lieu of wrapping the conductor around the screw. Bill @ Sparky Channel typically does the same. (But I’d probably still use a manual screwdriver.)
@donf3739
@donf3739 3 жыл бұрын
@@peacefrog0521 Yes, I like to have control of how tight to tighten it. I believe the author concurred with that later also.
@andrep.r.hammond4819
@andrep.r.hammond4819 2 жыл бұрын
So called "backstabbed" receptacles are ok for low wattage loads, but for appliances like electric fireplace or heaters with1250 watt load then they tend to heat up and melt the plastic, so please use the screw terminals.
@jhill4071
@jhill4071 3 жыл бұрын
Highly unlikly but if I pulled a receptacle cover and found a metal box I would check it to see if It was usable for a ground. This is also a good time to review the amp load on the circuit. The general consensus is that one should try to keep the load on a 12 gage 20-Amp circuit breaker to the area of 16 Amps.
@kevinlyman1
@kevinlyman1 2 жыл бұрын
How does one check to see if a metal box is suitable for a ground? This is my exact situation with a home from the 50's and I'm installing GFCIs in each of the kid's rooms but they also have metal outlet boxes.
@heftyjay1
@heftyjay1 2 жыл бұрын
@@kevinlyman1 Yes I'd like to know as well...can a receptacle (duplex) be made grounded by running a suitable wire from the grounding post ON THE RECEPTACLE to a grounding screw attached to THE METAL HOUSING the receptacle is mounted in? Thanks
@m.n.3490
@m.n.3490 Жыл бұрын
If my outlet is within 6 feet of water source (bath, kitchen, laundry), and is ungrounded, and I put in a GFCI, will I pass a rental inspection?
@tedlahm5740
@tedlahm5740 9 ай бұрын
Looking down in the basement/crawl space we could locate the beginning outlet? comment please
@morganinspectionservices3840
@morganinspectionservices3840 9 ай бұрын
I’m not sure what you’re asking here, but if I’m guessing correctly, yes, it is possible that the beginning outlet or the first outlet in the daisychain could be located in the basement.
@portiarobin
@portiarobin 3 жыл бұрын
After changing the first outlet in circuit to a gfci the other outlet down the circuit should I add a gound wire and screw when I change them?
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Unless the receptacle is installed in a grounded metal box, installing a ground wire will not help. Any receptacle must be grounded back to the panel in order for the a ground wire to do any good.
@WatcherMonkey
@WatcherMonkey 2 жыл бұрын
6:50-6:54 I’m the same way! I’d check, double check, I’d get side tracked. Then, check again! It doesn’t hurt to constantly check. Because what’s in that wall hurts even more!
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Good advice
@JamesTaylor-nw6ul
@JamesTaylor-nw6ul 2 жыл бұрын
So what kind of lights do you get on a plug-in tester? And what happens when you push the test and reset buttons?
@robertspeer8340
@robertspeer8340 3 жыл бұрын
Easy way to remember which wire goes to what is Brass goes Black, and silver goes to white. Green is either green or brass and is bare.
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Thanks. That is a good way to remember.
@teedee9903
@teedee9903 2 жыл бұрын
@@morganinspectionservices3840 , I always remember the movie that came out the year I was born (1947 ) named Black Gold. Good movie which has saved me from shock many times when wiring :)
@luminousfractal420
@luminousfractal420 Жыл бұрын
Ive got red, white, black, green, striped green, blue and brown in my house 😂 gotta love labourers who can do electrics huh. 🤦 Landlords an idiot.
@michaelleddy3701
@michaelleddy3701 Жыл бұрын
Whenever I come across the in and out wiring I like to take apart and pig tail them .
@jstins
@jstins 3 жыл бұрын
If it’s only a 2 prong outlet, do you still need to put both the labels on the downstream ones?
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
There is no need to put the ungrounded outlet label. It wouldn't hurt to put the "GFCI protected" label though.
@heftyjay1
@heftyjay1 2 жыл бұрын
I see that is a Milwaukee M12 but what is it called? It is not a full-size drill driver. Is it called a MINI? Please let us know...I want to get one!
@jimreilly6933
@jimreilly6933 2 жыл бұрын
I normally place a green Robertson driver head in my drill ! It is safer than the flat and more reliable.
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Thanks for the info.
@jaypayne957
@jaypayne957 Жыл бұрын
Are there any videos on KZfaq showing how to rewire a house?
@citrinwarren6073
@citrinwarren6073 3 жыл бұрын
If my rooms are ungrounded, do I need a GFI in each room? Thanks. Citrine Warren Sr. Severn MD.
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
It al depends on how the house was wired. You need a GFCI at the start of each circuit - wherever the circuit starts. This may be one per room, but it is possible to have multiple rooms on one circuit. It will require some investigating to determine this.
@IIIgemini
@IIIgemini 2 жыл бұрын
I'm guessing the panel was a panel with circuit breakers...? Will this also work with the old screw in fuse panels?
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Sure. The circuit doesn't care if its fed from breakers or fuses, so it does not matter at all.
@salvadorgalvan5024
@salvadorgalvan5024 2 жыл бұрын
I have only one that reads open ground. If I replace just that one with a GFI will it work ?
@okaro6595
@okaro6595 2 жыл бұрын
First, is it an old home with originally two prong outlets? Then you can use the GFCI method. If it is a new home with just somehow broken ground then that is not an option. Note the GFCI does not fix the open ground.
@JosephSmith72
@JosephSmith72 3 жыл бұрын
Good job Mike, we get it, you did this as quickly as possible and explained it coherently. I may be wrong but correct me if I am but is it not NEC code now to wrap all electrical outlets with black tape before installing inside the box, or is it just the non GFCI outlets? Thanks in advance Mike.
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Yes, I should have wrapped the outlet with tape before putting it back into the wall. Thanks.
@thomasmarable6818
@thomasmarable6818 3 жыл бұрын
There is no code that says an outlet has to be wrap with tape.
@Kuya_Raf143
@Kuya_Raf143 3 жыл бұрын
Didn't mentioned to wrap by electrical tape "but" for safety reason peace.
@jamomeara1894
@jamomeara1894 2 жыл бұрын
@@morganinspectionservices3840 what is the rationale for taping?
@jacygardner2242
@jacygardner2242 2 жыл бұрын
@@jamomeara1894 it helps keep it from arcing to or from wires, box, stud etc... an extra safety device if you will. Nothing wrong with being too careful!
@thomasgerrald1859
@thomasgerrald1859 3 жыл бұрын
So I understand that this makes things safer but does this protect the electronics too? I have a relatively expensive computer that I want to put in the room where I have this issue, but not if it will mess my computer up in case of power outages or say lightning strikes, maybe I'm not fully understanding. Any help is appreciated, thanks!
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
GFCIs are designed to protect people from electrocution. They do nothing to protect connected equipment. By the same token, grounding the receptacles don't protect equipment. About the only way to protect equipment is with the home's grounding system (ground rod and grounding electrode conductor) and surge protectors.
@okaro6595
@okaro6595 2 жыл бұрын
If lightning strikes the wires your equipment will be toast no matter what. It is the grounding of the neutral that protects against voltage induced by lightning. Computers do not mind being ungrounded. There may be problems with equipment you connect the computer. Ideally you should use WiFi. In any case do connections powered down. Ungrounded computers put about half the mains voltage to the case and you may feel this if you touch it and something grounded. (not recommended), the current is just 0.5 mA so it is not dangerous on a working computer.
@newlinclark5937
@newlinclark5937 2 жыл бұрын
Was it necessary to install a ground wire to the GFCI and to the box
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
The box was not grounded, so connecting a ground would not have helped.
@arizonaaerialproductions6390
@arizonaaerialproductions6390 10 ай бұрын
It still shows and open ground due to no ground back to the panel. It protects the other outlets, but no ground. If a ground was present the middle light and the light on the right would be on indicating a true grounded outlet...
@m.n.3490
@m.n.3490 Жыл бұрын
I pulled out an old electric outlet, to replace it with a GFCI. I accidentally touched some part of the old outlet while removing it on the metal box, and saw a small spark. (I thought the fuse was out, but maybe I had the wrong fuse out). Now, I am reading 14 volts from hot to neutral, and from hot to the metal box(ground). I've pulled every fuse in the panel, and still see 14 volts! Note, the outlet was working fine before my accident (although the hot/neutral were reversed). What did I do break when that old receptacle sparked? Did I burn/short a wire, or junction? How do I find the problem. I cannot use continuity tests since I have 14 volts present. Help!
@luminousfractal420
@luminousfractal420 Жыл бұрын
14v seems an odd number...have you unplugged all your wall wart chargers etc? If theyve linked all the ground lines together maybe theres something else in the circuit discharging power. Not much takes 14v...main suspect to me would be a computer monitor as they use odd voltages. Perhaps a laptop with a 14v battery is plugged in someplace? May be active because the circuit isnt correct....just throwing some options im no electrician.
@m.n.3490
@m.n.3490 Жыл бұрын
@@luminousfractal420 Hi. There could have been a laptop plugged in on the 1st, or 2nd floor. I ended up installing the gfci, and this was a basement Outlet, and it is working fine. Gfci even tests properly, and has ground. I thought it the gfci would not be grounded, as I did not see any green or bare copper wire in the receptacle. But, the GFCI does test as having a ground also. This is an old house built around 1928, and a few of the other gfcis that I thought were lacking a ground, actually tested good for a ground also. I think there are ground wires going to the water pipes, which are galvanized steel. So the ground system might well be all tied together. One other thing I noticed after all this, I was replacing some incandescent bulbs with LED bulbs in the basement also, and they all seem to work fine except for on one bulb outlet. The incandescent bulb was working fine, but when I tried to put an LED in it flickered and then would not stay on. I tested that led in other lamp fixtures and it worked well everywhere else. So, I ended up leaving the incandescent bulb in, and and it still works fine. It got me wondering if maybe that bulb fixture was on the same line as the GFCI that I just put in, or, wondering why else would an incandescent bulb work in a lamp fixture, but not an LED?
@babyboinews6896
@babyboinews6896 2 жыл бұрын
@morgan inspection services, I noticed you didn't run a ground wire off the GFCI. Do you have to run one? Reason being, I've seen people run one off the GFCI to the box in the wall outlet box, if its metal.
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
The whole point of the video was to show how to make the receptacle safe if there is no ground available. In this case, since the metal box was not grounded, running a ground wire from the ground screw to the box would not have helped..
@babyboinews6896
@babyboinews6896 2 жыл бұрын
@@morganinspectionservices3840 I'm confused because other videos show the box not grounded but they ran a ground wire from the box to the GFCI my question is would that help or not
@USArmy91222
@USArmy91222 2 жыл бұрын
@@babyboinews6896 no expert here but i believe only if the box is grounded would it benefit you to run a ground wire from the box to the GFCI..otherwise it would provide no help
@babyboinews6896
@babyboinews6896 2 жыл бұрын
@@USArmy91222 and by that you mean it should be a metal box to be grounded right
@USArmy91222
@USArmy91222 2 жыл бұрын
@@babyboinews6896 yes, my house was built in the 50's and has all metal boxes..a simple way to tell if your box is grounded is to get a inexpensive tester..put the red lead of the tester into the smaller slot of the outlet and take the black lead and just touch the screw that holds the cover in place..if you get a reading 110v it's grounded..
@luminousfractal420
@luminousfractal420 Жыл бұрын
I love british sockets and wiring more everyday 😂
@Llquiquell
@Llquiquell 2 жыл бұрын
So does this pritect all the outlets in the house? Or would this need to be done to every room?
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
One GFCI will protect all of the receptacles downstream of it on the same circuit. You would have to install enough GFCI receptacles so that all other receptacles in the home are protected.
@okaro6595
@okaro6595 2 жыл бұрын
It protects the outlets downstream that is you need at least as many GFCIs as there are breakers but remember there is no rule that you need to change every outlet. If there are locations where you do not need the third prong you can leave them alone. (assuming there is no illegally installed three prong outlet)
@shootnguns6075
@shootnguns6075 3 жыл бұрын
I noticed that you used a 20 amp GFCI outlet, could you have used a 15 amp GFCI outlet or is there a particular reason why you used a 20 amp GFCI outlet? Thanks
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
No. There would be no problem using a 15-amp outlet. I used a 20-amp outlet because there was #12 wire running to the outlet.
@craigjackson5492
@craigjackson5492 3 жыл бұрын
get your gfci outlets installed for 2o21
@daytona3926
@daytona3926 Жыл бұрын
Can you trip the ones not ground wire?
@morganinspectionservices3840
@morganinspectionservices3840 Жыл бұрын
The normal receptacle tester with a little push button to test the GFCI will not trip one that is not grounded, but the built-in test button on the outlet will test and trip the GFCI outlet.
@teamsilva7563
@teamsilva7563 7 ай бұрын
Will this strategy pass a code inspection?
@morganinspectionservices3840
@morganinspectionservices3840 7 ай бұрын
It depends. Code enforcement people realize that doing this is much safer than leaving the outlets ungrounded and unprotected, so in some places they will work with you and be happy for any safety upgrades that you do. Is it completely up to today’s electrical code? No. I would suggest you talk to the code enforcement people in your city and see what they say about it.
@chrisbrown6804
@chrisbrown6804 3 жыл бұрын
I just tried this, all 5 outlets on the circuit have only 2 wires connected to them, none of mine have 4 wires so it was impossible for me to find the beginning outlet to install a gfci, any suggestions or is it something im missing?
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
You’re sure that all those outlets are on the same circuit? It’s unusual that five outlets on the same circuit would be wired without daisychaining them together. If that is the case, then you will have to install a GFCI outlet at each of those five locations. Another option would be to install a GFCI breaker, and that would accomplish the same thing - and would be much quicker to do. You would have to do some research to see exactly what’s required to install a GFCI breaker, but it’s not too difficult.
@chrisbrown6804
@chrisbrown6804 3 жыл бұрын
@@morganinspectionservices3840 yes they are all on the same circuit, when I kill the breaker, all 5 of them had no power
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
@@chrisbrown6804 Then they are likely all tied together in a junction box somewhere. I think the previous solution I gave yesterday is likely the best way to add the GFCI protection.
@cliffkinsel6295
@cliffkinsel6295 8 ай бұрын
what happens if you push the test button and it does not trip . is that because there is no ground
@morganinspectionservices3840
@morganinspectionservices3840 8 ай бұрын
Great question. If you are pushing the test button on the receptacle itself, it should trip regardless of whether it’s grounded or not. If this is what you are pushing, and it is not tripping, then there is a problem that needs to be found and corrected. If you have a separate receptacle tester with built-in GFCI tester, and you’re pushing that button, then that button will not trip a GFCI receptacle that is not grounded.
@andyru1232
@andyru1232 Жыл бұрын
Can you cite the code that requires this protection? I'm in a similar situation with a home I'm buying and would like to be able to specifically call out the code to the sellers
@morganinspectionservices3840
@morganinspectionservices3840 Жыл бұрын
I would not say that the NEC requires this protection, but it permits this protection. It allows a GFCI-protected receptacle to be installed where there is no equipment ground. Due to grandfathering, the NEC does not require things like this to be installed to bring a house up to modern codes/standards. However, the NEC does permit such installation, and this installation will make a home safer. I am a home inspector, and as such, I regularly call out as a deficiency the lack of grounds on receptacles. While the NEC does not require a house to be brought up to current codes, and a home inspection cannot enforce/require the same, we still call it out as a deficiency. Section 406.4(D)(2) of the NEC covers what is required when a three-prong receptacle is installed in place of an ungrounded (two-prong) receptacle.
@vando4949
@vando4949 3 жыл бұрын
what if there are only one black and one white instead of 2 blk. and 2 wht. like your. Please reply, thanks very much.
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
If there is only one black and one white wire, then that is either the last outlet in the daisychain, or it is fed directly from a breaker, which is unlikely. At any rate, you just need to connect the black and white wire as described in the video to the screws labeled “line.“ If you are trying to protect multiple outlets with a GFCI, and this is the one you found, then you need to keep looking because this one will definitely not be the first one in the daisy chain.
@kvdgadj
@kvdgadj 3 жыл бұрын
Is a line and load for a light switch?
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
"Line" is where the wires supplying power to the outlet are connected. "Load" is where the outlets are connected that you want to protect with the GFCI. Lights are not normally protected by GFCIs.
@vicvera8949
@vicvera8949 2 жыл бұрын
No Black tape on the GFCI outlet?
@muhamadomar2040
@muhamadomar2040 Жыл бұрын
Can i change all the outlet with gfci thk
@morganinspectionservices3840
@morganinspectionservices3840 Жыл бұрын
Yes. You can. That is no problem. It just is not normally necessary. If the outlets are tied together (daisy chained), then one GFCI can protect several standard outlets.
@paulmiller8970
@paulmiller8970 3 жыл бұрын
How do you have a home inspection license. A GFCI does not make it safe to install 3 prong outlet without a ground
@okaro6595
@okaro6595 3 жыл бұрын
NEC disagrees.
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
I'm sorry but it sounds like you need to study up some on electrical issues. A GFCI makes ungrounded outlets much safer than with no GFCI.
@TK-cl1jm
@TK-cl1jm 2 жыл бұрын
Incorrect. It won't protect your equipment, but it will protect you.
@luminousfractal420
@luminousfractal420 Жыл бұрын
@@morganinspectionservices3840 much safer but applies all the protection of a true ground?
@morganinspectionservices3840
@morganinspectionservices3840 Жыл бұрын
@@luminousfractal420 The person above who said “it won’t protect your equipment” does not understand the purpose of the ground wire. It’s ONLY purpose is to protect people. It does not protect equipment. The home’s grounding electrode system protects equipment. I would certainly prefer to have my home’s receptacles grounded than to use the method I show in this video, but this method does make the home much safer than doing nothing.
@tedlahm5740
@tedlahm5740 9 ай бұрын
Hand held polarity tester (GFCI button) will not work on this ungrounded circuit. comment please
@morganinspectionservices3840
@morganinspectionservices3840 9 ай бұрын
That is very correct. A handheld tester (three light tester) with a GFCI test button will not work on an ungrounded receptacle. You must use the test button that is built into the receptacle itself. The reason it will not work is because the button on the handheld tester utilizes the ground wire on the receptacle to create a “ground fault.“ Without the ground wire, pushing this button does nothing.
@tedlahm5740
@tedlahm5740 9 ай бұрын
@@morganinspectionservices3840 Yet the test button on the GFCI (ungrounded circuit) Does function. comment please
@dougpenrod8867
@dougpenrod8867 2 ай бұрын
Since was mtal boxes i wouldve tape around it
@Candificent85
@Candificent85 3 жыл бұрын
Does this prevent a appliance or TV from getting fried or electrocution?
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
GFCIs do not protect appliances. They are designed to prevent electrocutions.
@okaro6595
@okaro6595 2 жыл бұрын
TVs typically are double insulated so they do not care of the protective grounding. Computers use grounding. You should be careful if ypou connect a computer to a TV with this. Do not plug when the computer is running. Computers generate voltage on the case. This is about half the mains voltage and if it is not grounded you can feel that if you touch it and something grounded (in general not a good idea) but it is not dangerous. The current is about 0.5 mA.
@gjrp18
@gjrp18 3 жыл бұрын
Will that work even without ground line?
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
Yes. The whole purpose of the video is to show how to make ungrounded outlets safer by installing a GFCI outlet.
@robertgarcia584
@robertgarcia584 3 жыл бұрын
In my experience the GFCI outlets will not work correctly without a ground. You still need to provide a good ground to the GFCI in order to protect the loaded circuit that follows. If you try to test that GFCI without a ground with a GFCI tester, the tester will not only show that it is wired incorrectly but that GFCI will not trip/reset after being shorted. Thus making GFCI having no more purpose than a regular ungrounded outlet. It is, after all called a GROUND FAULT CIRCUIT INTERUPTOR after all.
@nova31337
@nova31337 3 жыл бұрын
@@robertgarcia584 Read the instructions when you buy one. It says connect to grounding wire (only if there is a grounding wire). It does not say the unit can't be used. The GFCI receptacle looks at stray voltage on both the ground and the neutral lines, so it will interrupt if there is an imbalance between the hot and neutral as well.
@enrico5232
@enrico5232 2 жыл бұрын
I give you 3000 like
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Thank you.
@adamkrol6428
@adamkrol6428 3 жыл бұрын
Isn’t it supposed to have two lights on the right side
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Are you asking about the tester having two lights or what?
@bryanl1977
@bryanl1977 2 жыл бұрын
Only if the outlet is grounded. It's still not grounded, just ground fault protected. As commented by others, he also needed to apply a "no equipment ground" to the GFCI outlet cover plate.
@Wunderpus-photogenicus
@Wunderpus-photogenicus 3 жыл бұрын
Question: My Tesla car charger (for 120V) would not work if the outlet is not grounded. Now, since a GFCI outlet basically is as safe as if it is grounded, would the Tesla charger work on a GFCI outlet since it is also considered grounded?
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
The outlet is safer because it is GFCI protected, but it is still not grounded. I have never dealt with tesla chargers, but if they do not work if the outlet is not grounded, then it will still not work even with the GFCI.
@joerostkowski7313
@joerostkowski7313 2 жыл бұрын
Would be better if you explained line and load side of a gfci! Any one knows how to screw but line and load is what confusing for newbies
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Thanks. A video with a better explanation of line and load is coming soon.
@j.r.moparman2764
@j.r.moparman2764 2 жыл бұрын
Take the "L" off of 'LINE' and first two letters then are 'IN' (INcoming) power. L 'O' A D side of GFCI = 'O' utgoing power. Is how I can remember the electricity " IN " & " O " (Out) .
@billhollin49
@billhollin49 3 жыл бұрын
Tape around terminals
@jamomeara1894
@jamomeara1894 2 жыл бұрын
I’ve read not to do this as it’s not necessary. What is your rationale for taping?
@tedlahm5740
@tedlahm5740 9 ай бұрын
All outlets in the chain are wired in parallel. comment please
@morganinspectionservices3840
@morganinspectionservices3840 9 ай бұрын
Yes, all outlets in a daisychain are wired in parallel. All outlets in every house/building are always wired in parallel. If they were not wired in parallel, the 120 V would be divided up among the outlets based on the loads that were running on those outlets. Only by wiring in parallel will you have 120 V at each outlet.
@KevinJones-pj8kx
@KevinJones-pj8kx 3 жыл бұрын
You should also wrap electrical tape around the outlet covering the terminals
@brianreinhardt4050
@brianreinhardt4050 3 жыл бұрын
Please cite where in the NEC it says to do so...Karen.
@Jason-bt8dn
@Jason-bt8dn 3 жыл бұрын
@@brianreinhardt4050 It doesn't but it's good to have should you box be metal.
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
Not a bad idea, but not required as far as I know.
@JohnSmith-kc3yj
@JohnSmith-kc3yj 3 жыл бұрын
Where did you learn this from ??? Other people on youtube I am a retired electrian So why spend the money for a GFCI outlet when a normal outlet will work The ground isn't hooked up on the GFCI anyway When replacing a old outlet with no ground Take a short wire and connect were the white hooks to it if you have the extra space on the outlet and run this to the ground screw At lease you will have a grounded outlet and your test light will work right I did this to my whole house This is probably as legal as your GFCI deal but you will have a grounded outlet
@morganinspectionservices3840
@morganinspectionservices3840 2 жыл бұрын
If the metal box is not grounded, connecting a ground wire will not ground the outlet. If it were that easy to ground outlet, that would sure be nice.
@craigjackson5492
@craigjackson5492 3 жыл бұрын
call your electrician
@martinmercerjr8615
@martinmercerjr8615 3 жыл бұрын
Why don’t they make labels to match the outlets. I don’t like the blue stickers . It stands out
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
I suppose they don't want the labels to match the outlets because they want them to stand out an be obvious.
@mikegee3991
@mikegee3991 2 жыл бұрын
The outlets I got from amazon were white with black lettering and small. you can also just buy the labels from ebay and they're also white with black lettering.
@dmoua02
@dmoua02 3 жыл бұрын
GFCI outlet DOES NOT make a non-grounded circuit grounded!
@morganinspectionservices3840
@morganinspectionservices3840 3 жыл бұрын
You are absolutely correct, but a GFCI outlet makes a non-grounded outlet a lot safer than it was.
@donbushek
@donbushek 2 жыл бұрын
He never said it did!
@michaelgrant7663
@michaelgrant7663 Жыл бұрын
I was told any electrician worth his spit doesn't use those quick connections because they're not very reliable
@metalhalide4043
@metalhalide4043 3 жыл бұрын
An ungrounded outlet will not protect anything plugged into that outlet against voltage spikes which needs ground path, wire that old will have bad insulation and is fire hazard, do not be cheap rewire it..
@okaro6595
@okaro6595 3 жыл бұрын
Grounding has nothing to do with voltage spikes. It is use for personal protection in case of an equipment failure.
@metalhalide4043
@metalhalide4043 3 жыл бұрын
@@okaro6595 Lightning and surge protection devices work by routing voltage surges and spikes away from the electrical components they are protecting and dispersing it to a ground plane, such as the earth or a copper pipe inside of a building. Every grounding system therefore consists of two main components: the protection device that routes the damaging signals and the ground connection the signals are routed to. It is important that both components are in place and properly utilized. One without the other, or one properly implemented with the other improperly implemented, is the same as no surge protection system at all.
@okaro6595
@okaro6595 3 жыл бұрын
@@metalhalide4043 Surge protectors have varistors between each wire pair so they work also without grounding. Maybe they work better with grounding. Now there are some issues in running computer ungrounded. Plug your peripherals on the same power strip so it levels the potentials. If one wants to be extra sure one an use WiFi instead of Ethernet. Do not connect it to TV. Instead use other ways to stream like Chromecast. However many people use computers ungrounded without any problems
How Many Ground Fault Circuit Interrupters On One Breaker
15:59
Why Not DIY
Рет қаралды 189 М.
5 ways ways to fix an "open ground" UPDATED Video in description!!
14:56
Electrical Code Coach
Рет қаралды 169 М.
Tom & Jerry !! 😂😂
00:59
Tibo InShape
Рет қаралды 59 МЛН
Вечный ДВИГАТЕЛЬ!⚙️ #shorts
00:27
Гараж 54
Рет қаралды 12 МЛН
Did you believe it was real? #tiktok
00:25
Анастасия Тарасова
Рет қаралды 13 МЛН
How to Wire a GFCI Outlet without a Ground Wire in an Older Home.
12:36
Electrical Tips
Рет қаралды 252 М.
People Are Adding Deadly Hacks to Outlets
8:54
LRN2DIY
Рет қаралды 1,1 МЛН
How To Replace An Outlet | Ungrounded to Grounded
9:20
Aaron Fixes Stuff
Рет қаралды 520 М.
Does a GFCI Outlet Still Provide Protection Without A Ground Wire?
6:36
Everyday Home Repairs
Рет қаралды 281 М.
How to Wire a GFCI Outlet - What's Line vs Load? - Electrical Wiring 101
8:50
Stop Using Regular Electrical Outlets, USE THESE INSTEAD!
21:17
KERF How To
Рет қаралды 10 М.
3 Weird Ways to Ground a Two-Prong Electrical Outlet
7:18
Top Homeowner
Рет қаралды 95 М.