No video

Fluke 1507 Motor Insulation and low ohm Testing

  Рет қаралды 199,839

LUNORTEK

LUNORTEK

6 жыл бұрын

May 2020:
Hi,
I feel my channel is going off topic and I want to keep doing what I love the most (electronics), but to make new and better videos I need to get some new gear for my private electronics lab. This will cost me some money so I would be very grateful for everey donation I can get so I can keep posting new Electronics videos!
Thank you!
If you want to donate click this link:
www.paypal.com...
Testing the insulation Megging and Low Ohm testing windings on a old three phase Siemens electric motor Fluke 1507 Insulation Tester aka, Megger.
This Motor got too low readings on the insulation test and need to be refurbished.
The readings should be at min. 1G ohm, but a good motor reads 5G ohms plus. And the readings should be more constant and not climb in value this slow ( as shown on my video).
And note, the one minute test and ten minute test should be subtracted and NOT divided!! :)
Please Like, Comment and Subscribe to my channel :)

Пікірлер
Insulation Testing Fluke-1507 - Fluke Fridays - Episode 106
8:02
Fridays With Brandon
Рет қаралды 63 М.
Megohmmeters (Full Lecture)
16:19
Jim Pytel
Рет қаралды 109 М.
娜美这是在浪费食物 #路飞#海贼王
00:20
路飞与唐舞桐
Рет қаралды 6 МЛН
小丑把天使丢游泳池里#short #angel #clown
00:15
Super Beauty team
Рет қаралды 48 МЛН
Checking Windings in a 9 Lead 3 Phase Motor
7:55
AmateurHour
Рет қаралды 293 М.
How to Test Wire Insulation Using a Megohmeter
6:11
R.C. Worst & Co., Inc.
Рет қаралды 235 М.
Understanding STAR-DELTA Starter !
6:05
Lesics
Рет қаралды 8 МЛН
How to perform a “Loss of Insulation” test using a Fluke 1587FC
10:52
Ms.A The Shop Teacher
Рет қаралды 128 М.
Motor Control 101
15:59
Eaton
Рет қаралды 2 МЛН
What is the Difference between VFD and Soft Starter?
7:30
RealPars
Рет қаралды 2,4 МЛН
娜美这是在浪费食物 #路飞#海贼王
00:20
路飞与唐舞桐
Рет қаралды 6 МЛН