The HVAC transformer

  Рет қаралды 110,820

grayfurnaceman

grayfurnaceman

12 жыл бұрын

I discuss the low voltage transformer design for heating and air conditioning systems. The 24v transformer is used on most residential and commercial systems for thermostat power.
This video is part of the heating and cooling series of training videos made to accompany my websites: www.graycoolingman.com and www.grayfurnaceman.com to pass on what I have learned in many years of service and repair. If you have suggestions or comments they are welcome.
If you are a homeowner looking to repair your own appliance, understand that the voltages can be lethal, the fuels are highly flammable and high pressures are used. Know your limits.

Пікірлер: 46
@randymarsh6564
@randymarsh6564 Жыл бұрын
Ok thanks. watched a bunch of videos but this helped me a lot. just little things like short to ground is something laymen like me can be ignorant to. Now i know. Thanks again.
@PBS-nm1uu
@PBS-nm1uu 6 жыл бұрын
great demo please keep them coming thanks !!!!
@madcyborg
@madcyborg 8 жыл бұрын
Thank You for clarifying VA.. good video.
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
Welcome GFM
@jb-ik8sj
@jb-ik8sj 7 жыл бұрын
ok. that clears things up. thank you so much
@brianellsworth4767
@brianellsworth4767 7 жыл бұрын
I lost neutral in my house. Some outlets 175 volts and some had 50 volts ..All my 120 volt primary transformers fried .. Good tip on the inline fuse....They can save from replacing transformer twice ..or until you find the cause...although it would not have saved me from a power company fault.
@bencmoreno
@bencmoreno 11 жыл бұрын
thank you...............
@geojor
@geojor 9 жыл бұрын
great, thanks...
@jkbrown5496
@jkbrown5496 5 жыл бұрын
So that's how they make a class 2 transformer current limited. They incorporate the fuse on the secondary side. Recently I dug into code for low voltage circuits, discovering the class 2 is considered inherently safe because of voltage and power, i.e., VA/wattage, design limitations and self limiting. (60VA for 12v, 96VA for 24v) A DC power supply can be designed that self limits the current, but I wondered how they did it with the transformers. Class 1 or 3 power supplies/circuits require inline fusing to limit overcurrent.
@mts7274
@mts7274 Жыл бұрын
7:25 ...actually, transformers WILL cause failure on the furnace side in a split system when they burn out. A sticking contactor on the outside AC unit can contribute to this, all while the outside unit will still operate.
@grayfurnaceman
@grayfurnaceman Жыл бұрын
A sticking contactor is what is causing the failure because the contactor is overdrawing from a failing armature. Overdraw of the circuit is not the fault of the transformer. The point is the transformer seldom fails. It is damaged by an overdraw of the circuit. When you find a failed transformer, you need to look farther to determine if there is something that caused it to fail. GFM
@achilles1373
@achilles1373 4 ай бұрын
I dont have an inline fuse on my system and we had the powerline running the the house from the pole catch on fire. Also something chewed the 24v wire going to the ac unit. I replaced the wire, checked all fuses, checked the contactor and capacitor and all is well. I am not getting 24v at the contactor. I believe I have a bad transformer
@grayfurnaceman
@grayfurnaceman 4 ай бұрын
Check voltage coming into the transformer. Then check voltage coming out. Voltage in, no voltage out, transformer failed. GFM
@SombraLocs
@SombraLocs 9 жыл бұрын
Where can you normally hook up a resettable fuse to troubleshoot a short? My Heat Pump doesn't have a fuse, but I want to install an inline fuse.
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
SombraLocs On the R wire. GFM
@EurekaRecycler
@EurekaRecycler 8 жыл бұрын
I have a forced air gas furnace, the 4 wire transformer is dead. The output wire are colored. I went to the hardware store and they said a "24VAC door bell transformer would work. They told me the output is non polarized so the 2 wires that go to the control board are not polarized and it did not matter which wire goes where. Is this true? Thank you
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
+EurekaRecycler Unless the bell transformer is 40 VA capacity, it will not work. Polarity is not a problem. GFM
@SombraLocs
@SombraLocs 9 жыл бұрын
Should I be reading 24 volts on both leads of the transformer coming out the 24 side? I am checking one leg to ground on the low voltage and reading 28 volts and I checked the other leg to ground and getting 0, but if i check both together i read 28 volts. will the common side of the transformer read 0 if i check it to ground?
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
SombraLocs The transformer should read voltage across the 2 terminals. The transformer usually has one side connected to the chassis of the unit. Hope this helps. GFM
@jsp146
@jsp146 9 жыл бұрын
I really enjoy your videos, they are on point and very informative. I teach an HVAC Class at a state prison in Texas. Under the circumstances I cannot access the web in my class, but I would really like to show your videos to my classes. However, I am able to take a flash drive in with me. Would you be willing to authorize the downloading and use of your videos as training aids in my class? Thank you very much for your consideration!
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
Shane Pritchard No problem. Go for it. Tell them its a great profession that needs good people. GFM
@arivaldiv4078
@arivaldiv4078 7 жыл бұрын
Furnace man how many thermostats can one transformer power?????
@RalphsHeating
@RalphsHeating 7 жыл бұрын
Are the white and black on the HV side actually interchangeable? Or it the white some how tied to the body or if reversed will it not operate properly or safely? Thanks
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
They are interchangeable. White is not connected to the chassis of the transformer. The only reason for the different colors is if there is a fuse integral to the transformer, it will be on the black side. GFM
@RalphsHeating
@RalphsHeating 7 жыл бұрын
Thanks Good to know.
@jeremymass2770
@jeremymass2770 5 жыл бұрын
I was swapping thermostats and I think I hit the blue to red wire. Would that smoke the transformer?
@grayfurnaceman
@grayfurnaceman 5 жыл бұрын
I can't be sure as the color code is not always followed. Generally, if the blue is used as common it will blow the fuse in the transformer. GFM
@zakiization
@zakiization 10 жыл бұрын
my air conditioner is under 220v and i want to use a thermostat Nest that work with 24v, so what should i do to get both wired without damage, thank you.
@aol11
@aol11 Жыл бұрын
I noticed a humming coming from my transformer when the furnace is off. It is warm to the touch even when the furnace has been off for a long time. Is this normal? This is happening just after 3 doors down our neighbor installed a Tesla charger. My duplex and the one next door keeps burning circuit boards in the water heater also would these be connected?
@grayfurnaceman
@grayfurnaceman Жыл бұрын
The transformer hum is common. I won't say it's normal, but unless it is is loud enough to be a problem, it's ok. I can't see where a vehicle charger could affect other locations. I have one in my garage and it has no effect on anything. GFM
@Pretzel114
@Pretzel114 10 жыл бұрын
Hey GFM, Thanks for the video and explaining the Volt Amps that helped out a lot. I wanted to ask, if you could replace a 40VA with a 60VA if that is all you had in your truck at the time or if it needs to be the exact match? Thanks for your help.
@grayfurnaceman
@grayfurnaceman 10 жыл бұрын
Bigger will work, smaller may not. GFM
@Pretzel114
@Pretzel114 10 жыл бұрын
grayfurnaceman Thanks for the response I appreciate it. Take care.
@greatestcantor
@greatestcantor 9 жыл бұрын
Thanks for the posting Did you ever hear of grounding the neutral on a on the output side for boilers?
@grayfurnaceman
@grayfurnaceman 9 жыл бұрын
eel1452 If there are any unions between the boiler and the piping, it should be grounded. GFM
@greatestcantor
@greatestcantor 9 жыл бұрын
I'm talking about taking one of the wires from the 24 volts and bonding it to the box thereby creating forced polarity?
@jb-ik8sj
@jb-ik8sj 7 жыл бұрын
my unit is a 240v system. how do I wire the 240 tap with one wire? this system has no return and only a ground. I have one leg from L1 going to the 240v tap so my com is ground. and my 24v side only puts out 11 volts. so do I hook up the L1 leg and a leg from say T1 or T2 to the 240v tap? thanks. I'm stumped on this one
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
The primary of the transformer is just wired to each side of the 240 volt power source. The use of a common does not mean it is ground. GFM
@macster1457
@macster1457 7 жыл бұрын
I have a transformer that I can wire either as 16v or 24v. how do i wire it for 24v?
@grayfurnaceman
@grayfurnaceman 7 жыл бұрын
There should be a listing on the side of the transformer with color codes. One line will be common and the color code should tell which to use. GFM
@bardinkurtis
@bardinkurtis 8 жыл бұрын
on heat pumps what are the 2 24 volt wires hooked up to usually?
@grayfurnaceman
@grayfurnaceman 8 жыл бұрын
+kurtis bardic Lots of stuff. Contactor, reversing valve, defrost board are some places. This probably does not answer your question, but there is no "usually". I have been meaning to make up some wiring diagrams that are commonly used in heat pumps, but have not completed it yet. GFM
@bardinkurtis
@bardinkurtis 8 жыл бұрын
+grayfurnaceman that actually helps a lot your the man! im a instant subscriber😆 hopefully you can get to that soon
How to replace a transformer (without burning up the new one)
8:56
grayfurnaceman
Рет қаралды 405 М.
Harley Quinn lost the Joker forever!!!#Harley Quinn #joker
00:19
Harley Quinn with the Joker
Рет қаралды 27 МЛН
Get 10 Mega Boxes OR 60 Starr Drops!!
01:39
Brawl Stars
Рет қаралды 15 МЛН
The Fundamentals of Control Transformers  Part 1
7:29
rawhidejim
Рет қаралды 154 М.
Blown transformer and low voltage short.
14:45
HVAC GUY
Рет қаралды 33 М.
10 Incredible Homemade Inventions Which Are On Another Level
13:15
Creation Holic
Рет қаралды 96 М.
Understanding HVAC Schematics - 1
8:01
Ron Walker
Рет қаралды 538 М.
HVAC more about SPST, SPDT and SPNO-SPNC relays
4:47
DrZarkloff
Рет қаралды 252 М.
This Car Brand is Shutting Down Production (Do Not Buy)
10:32
Scotty Kilmer
Рет қаралды 96 М.
How to Find a Short (HVAC)
32:06
Word of Advice TV
Рет қаралды 730 М.
Harley Quinn lost the Joker forever!!!#Harley Quinn #joker
00:19
Harley Quinn with the Joker
Рет қаралды 27 МЛН