Greenstar junior pin holed plate heat exchanger

  Рет қаралды 1,036

The Mental Gas man

The Mental Gas man

Күн бұрын

Little video on how to measure and test an NTC sensor , these readings can be checked against the relevant ntc sensor chart or readings obtained from the manufacturers
Heating and Boiler repair specialists in West Midlands
www.3tgas.co.uk
0800 9997870
Instagram the_mental_gas_man
MENTalk mental health advocate
www.MENTalk.online
Baxi ,Worcester Bosch , Viessmann, vaillant, ATAG, main , megaflo, ferroli, Ravenheat, navien , grundfos, wilo, Heatgeek, Intergas , talon , heatrae sadia , adey, boiler repairs , boiler servicing, central heating , boiler installation, new boilers , power flushing , vdi2035, magna clean , adey chemicals , faulty pumps , faulty pcb’s , diverter valves , balancing , efficiently , gas engineers

Пікірлер: 10
@charliewillis8527
@charliewillis8527 Жыл бұрын
Great video but I would have changed the prv as well had it a few times saves you going back
@joncoke8208
@joncoke8208 2 жыл бұрын
Great video another way to test is just isolate cold to boiler
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 жыл бұрын
I prefer to isolate at stop tap if mixer taps in property , to eliminate cold passing back up hot pipe which I’ve had quite a few times
@stewartharrod1706
@stewartharrod1706 2 жыл бұрын
Why does the pressure go up if the heat exchanger is pin holed Sorry if uts a daft question Bit new to all this 🙂
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 жыл бұрын
@@stewartharrod1706 if the plate heat exchanger is pin holes the cold main supplying the boiler will be a great pressure than the ch system , so it will pass through into the heating circuit causing the pressure to rise up
@stewartharrod1706
@stewartharrod1706 2 жыл бұрын
@@thementalgasman3tgasmainte317 💯❤ awesome thanks bro
@lazylady81
@lazylady81 2 жыл бұрын
So you need to remove pipe work to slide out plate?
@thementalgasman3tgasmainte317
@thementalgasman3tgasmainte317 2 жыл бұрын
Yes buddy slide cold out the way and the plate will come out
@brianmayne6513
@brianmayne6513 2 жыл бұрын
Another good video. I know the Greenstar provides loads of repair work but they are one of the worst boilers ever made.
Vaillant ecotec plus pin holed heat exchanger @thementalgasman3tgasmainte317
32:32
Glowworm Flexicom Repair
8:59
HeatingGeek
Рет қаралды 37 М.
Получилось у Миланы?😂
00:13
ХАБИБ
Рет қаралды 4 МЛН
HOW TO CLEAN - Plate Heat Exchanger - What’s Inside
18:09
Allen Hart
Рет қаралды 94 М.
It’s a Peterbilt thing
16:00
Farming Fixing & Fabricating
Рет қаралды 10 М.
Greenstar 30i EA fault 227 @thementalgasman3tgasmainte317
8:45
The Mental Gas man
Рет қаралды 15 М.
Testing a gas valve on a Worcester Bosch & setting it up in service mode
3:54
CP Utility Solutions
Рет қаралды 28 М.
Demolishing a house
39:46
Andrew Camarata
Рет қаралды 290 М.
How To Remove A Worcester Bosch Plate Heat Exchanger...Quickly!!
14:33
Blue Bulldog Plumbing
Рет қаралды 6 М.
Goodman Hole In Heat Exchanger
9:29
Michigan Heating Guy
Рет қаралды 80 М.