Greg and Joel explain how to install a proper grounding system for electric fence.

  Рет қаралды 30,590

Greg Judy Regenerative Rancher

Greg Judy Regenerative Rancher

4 ай бұрын

Greg and Joel explain how to install a proper grounding system for electric fence. Most electric fence problems are traced back to an improper grounding system. Take note here on how to install your own grounding system for years of excellent service.
Spring is right around the corner and if you have any fence building projects, you can get a 10% one-time discount from Powerflex Fence products by clicking on this link to automatically receive your own one-time discount of 10%: powerflexfence.com/judy10

Пікірлер: 50
@user-kv2pt4lu9y
@user-kv2pt4lu9y 4 ай бұрын
Great to have the interns explain tasks! The best test is having to teach a task, skill.
@danielb1877
@danielb1877 3 ай бұрын
Just had a car run through our fence, took out 150'. Was going to change the fence anyway. Previous owners had horses, but we are going to get a sheep operation going. So I appreciate these videos, Greg.
@alisonwestermann1875
@alisonwestermann1875 4 ай бұрын
These fencing videos have been so helpful, thanks!
@jacobmustain1181
@jacobmustain1181 4 ай бұрын
Just a recommendation, but i would highly advise using copper clad ground rods. the galvanized rod will corrode and the corrosion acts like insulation and will negate the conductivity of the rod. I am an electrical engineer and do consulting for power companies and have done ground studies and found many ground grids that used galvanized rods that have no conductivity.
@Schaapkraal
@Schaapkraal 4 ай бұрын
Isn't the fence wire being galvanized going to cause problems being connected to a copper clad earth rod?
@twatbuger
@twatbuger 3 ай бұрын
Galvanic corrosion
@charleswalters5284
@charleswalters5284 3 ай бұрын
Where i am, it's cooper or fail inspection and void warranties
@jacobmustain1181
@jacobmustain1181 3 ай бұрын
@@Schaapkraal that is a possibility and if you are using a galvaized wire you could use a tinned connector to to transition from galvanized to copper but its easier to clean a corroded connection above ground than to have a ground rod buried in the ground doing that's rusted and not conducting for the ground.
@thurlowfamilyfarm4628
@thurlowfamilyfarm4628 2 ай бұрын
you should not mix metals, if you use copper, the rod, connecting wire and clamps all have to be copper, and the same if its galvanized.
@lelocle4262
@lelocle4262 3 ай бұрын
I like these detailed, hands-on tutorials!
@francineclave2207
@francineclave2207 4 ай бұрын
I always learn useful things watching your channel!
@user-fv5ri7hj8s
@user-fv5ri7hj8s 4 ай бұрын
Great explanation on how to make tight ground connections. When that ground wire comes off the charger & runs through all the ground wires does it then become one of the ground wires on the post going all the way to the other ground rod you mentioned a mile away or does is laid on the ground or buried to that last ground rod? If it is one of the wires on the fence post which is it? I would assume it is the bottom wire because you wouldn't want the bottom wire hot because eventually weeds will short it out. Also on an alternating wire fence [hot strand ground strand] does the animal have to touch both a hot & ground strand together to receive a shock? On the fence we currently have the ground wire just runs to some ground rods near the charger so every strand on our fence is hot. Fence looks beautiful! You fellows inspire me! I really enjoy your videos & attention to showing details. I know it must take a lot more of your productive time to stop & film as your working. It does not go unnoticed!
@big-d7756
@big-d7756 3 ай бұрын
The ground rods only need to connect to charger. The Hot wires carry the charge and when something contacts it and is touching the ground/earth it will receive a shock. You can your ground rods a few feet apart and directly connect them together. I ran mine 12 feet apart beside the post for my gate both sides. And it works great.
@marvinbaier3627
@marvinbaier3627 4 ай бұрын
Thanks for the video! All the questions I asked is given in a future video! You all the best. I’m so excited you got your fencing project is complete. We are getting snow now. Crazy weather. I need to check but as of last night we got 2 inches of rain starting on Sunday evening so that’s about 4 inches of moisture in 2 weeks. Seeing the grass there it really looks great. The animals going to do back flips see new pasture.
@dsulli7383
@dsulli7383 3 ай бұрын
He started getting paranoid about revealing the location of his solar panel. And ended the video! lol
@cpt.moroni3092
@cpt.moroni3092 3 ай бұрын
Looks good and I’m learning a lot. Can’t wait to see you for grazing school in May.
@forcesfarming8511
@forcesfarming8511 4 ай бұрын
8:08 I’ve used Patriot fencers for a few years. Solid little things.
@newlifetv121
@newlifetv121 3 ай бұрын
Thanks for sharing. I enjoyed watching.
@WheretheJones
@WheretheJones 3 ай бұрын
We buried our 50 - 8' grounding rods in our grounding grid for Florida's sandy soil but we heavily sealed all the connections.
@gregjudyregenerativerancher
@gregjudyregenerativerancher 3 ай бұрын
That is one heck of a grounding system!
@michaelsallee7534
@michaelsallee7534 4 ай бұрын
makes me want to rebuild my grounding system
@michaelsallee7534
@michaelsallee7534 4 ай бұрын
Joel you agree with my old sows ... a year after decommissioning the hot wire ... they knew it was still hot
@Kathleen67.
@Kathleen67. 3 ай бұрын
Great tips
@dougkuykendall1547
@dougkuykendall1547 3 ай бұрын
If I understand correctly, the way you have this perimeter fence setup to work in conjunction with your temporary fencing, only the high tensile will ground back to the Energizer. In regard to any cattle, sheep, etc touching a temporary wire, they must ground through the ground back to the Energizer. I read many questions regarding the grounding of a good system. May I suggest more input on the subject? Perhaps a video answering questions you have received... following a format such as yourself, Jan, and all the guts chiming and giving their ideas!
@accessiblenow
@accessiblenow 4 ай бұрын
Good tech lesson
@benjaminbrewer2154
@benjaminbrewer2154 4 ай бұрын
The Patriot SG1000 is 1.0 joules or 1.3 stored joules.
@kevinburke5592
@kevinburke5592 4 ай бұрын
Novice question here. About how long would you say it took for the total fencing job? Man hours. I waiting on hearing from a landlord about a 90 acre lease that I estimated would take 15 man days to fence in.
@nicholasmacinnis1486
@nicholasmacinnis1486 4 ай бұрын
Good lesson, just learned something. I’ve been attaching ground rods using insulated wire and every couple months the connection corrodes. Will you attach any additional ground rods to the ground wires you’ve put along the perimeter
@BandanazX
@BandanazX 2 ай бұрын
If you are going to touch an electric fence, use the back of your hand so that you don't grab onto it and possibly can't let go.
@alanblyde8502
@alanblyde8502 Ай бұрын
It’s a pulse you’ll soon enough let go that’s for sure
@matthewmatiasek1777
@matthewmatiasek1777 4 ай бұрын
If I’m following is one of your wires neutral or is it tied into the ground. I have a fence line that’s 6 strand with 2 neutral and trying to decide if I want to make those negative
@OBFARMS
@OBFARMS 3 ай бұрын
I think I need more ground rods in the dirt...
@tysonanderson9550
@tysonanderson9550 Ай бұрын
Where can I find your Video on installing the Energizer and solar panels?
@tt-kn6wn
@tt-kn6wn 23 күн бұрын
Thanks for the vid. Please, how far should the first ground stake be from the energizer (which is near the fence about 50 metres from the house)? Further, can the wire connecting the earthing rods present a jolt if touched (that is, must the wire be insulated)?
@gregjudyregenerativerancher
@gregjudyregenerativerancher 22 күн бұрын
10 feet from the charger is where first ground rod should be located. You can use plain galvanized hitensile wire to connect all the ground rods.
@treybrake7516
@treybrake7516 3 ай бұрын
I’m afraid your 120 watt panel is not going to be enough. I started with a 120 for my 12000i chargers and it would not keep the battery up. Found a good deal on some 230 watt panels, way over kill but fixed my issue. Just make sure your charge controller is big enough to handle a panel that big. Also another thing I learned the hard way, put a quick disconnect between your panel and your charge controller. Make sure the power from the panel is disconnected before you take the battery off the controller. You can fry the controller otherwise
@gregjudyregenerativerancher
@gregjudyregenerativerancher 3 ай бұрын
I bought a 180 watt panel. Thanks for the tip on the other items!!!
@philipwickline5761
@philipwickline5761 3 ай бұрын
Why does your ground wire have a charge on it?
@gregjudyregenerativerancher
@gregjudyregenerativerancher 3 ай бұрын
@philipwickline5761 if you hold your fence tester in the air, 2-3 inches from your hot wire, you will get a similar reading.
@danielb1877
@danielb1877 3 ай бұрын
@@philipwickline5761 Induction.
@markpennella
@markpennella Ай бұрын
How do you have one grounding wire a mile from the other 5 grounding rounds?
@benjaminbrewer2154
@benjaminbrewer2154 4 ай бұрын
Is it a bad practice to make the ground looped, both ends terminated at the charger, other than using double the wire. (If one wire should fail was my novice idea).
@JonathonYoder-qe5un
@JonathonYoder-qe5un 3 ай бұрын
Hey Joel, instead of beating and beating and beating and buggering up the rod tops, you could try this next time. 1: Use a shovel to dig a hole as deep as is handy. At least 3 inches. 2: Fill the hole with water. 3: Push the rod in as far as you can by hand. Should go several inches. 4: Pull the rod back out and allow water to enter the rod hole, then repeat the process, working the rod in and out until your rod is as deep as is easy to do. 5: Finish driving with a sledge hammer. There's a better than good chance that you will be amazed at how well that works. I have used this method many times over the years. Rocky soils would probably pose and issue though.
@Enlightn76
@Enlightn76 3 ай бұрын
This is the way. Make your own mud!
@robscott553
@robscott553 3 ай бұрын
Are you using the same gauge wire for connecting the ground rods as the high tensile fence?
@robscott553
@robscott553 3 ай бұрын
Oops. Should have listened all the way through before asking my question. 🤣🤣
@davidpeightal4918
@davidpeightal4918 2 ай бұрын
Man. These are not for idiots like me. One of the fence wires was a ground wire. ? And I gathered that maybe it is hooked to ground rods somewhere else on the farm? Six, six foot rods again? Will that work for goats? And I have no clue why we are running the last few feet of (on the ground) ground wire through insulated cable. Maybe in case they use the steel post for the charger? But why would that matter if it is a ground wire on another grounding post? And why tie it in so far from the box?
Expert Tips For Your Electric Fence!
9:28
Farm Learning with Tim Thompson
Рет қаралды 19 М.
Building hi-tensile fence from beginning to end.
29:39
Greg Judy Regenerative Rancher
Рет қаралды 125 М.
Red❤️+Green💚=
00:38
ISSEI / いっせい
Рет қаралды 85 МЛН
Finger Heart - Fancy Refill (Inside Out Animation)
00:30
FASH
Рет қаралды 27 МЛН
The Easiest Way To Drive Grounding Rods
6:45
Practical Home Projects
Рет қаралды 176 М.
Electric Fencing Ep. 3: Ground Systems
6:56
Frontier District
Рет қаралды 28 М.
How does an Electric Fence system work?
2:44
JVA Electric Fencing
Рет қаралды 43 М.
Greg and Joel explain how to build your own economical electric fence gate from scratch.
18:47
Installing an earth Rod - New TT Supply
30:36
Residual Electrical
Рет қаралды 44 М.
Earthing vs. grounding
7:06
Paul Saladino MD
Рет қаралды 92 М.
Building an electric fence gate from scratch, step by step.
23:16
Greg Judy Regenerative Rancher
Рет қаралды 52 М.
How To Dig The Perfect Post Hole
16:26
SWI Fence
Рет қаралды 364 М.