Hidden Dangers Of Water Heaters: How To Install Safely? | Talking Point | Full Episode

  Рет қаралды 266,517

CNA Insider

CNA Insider

Күн бұрын

Since 2014, all electrocution deaths at residential flats in Singapore were linked to water heaters. Besides electrocution, water heaters also pose fire and explosion risks to homeowners. From storage to instant water heaters, just how safe is our water heaters? Can they potentially kill us when we least expect it?
0:00 When water heaters turn deadly
2:22 How water heaters can kill
6:22 Different types of water heaters
7:15 How safe is my water heater?
9:35 Storage VS instant water heater
13:35 How my water heater caught fire
16:03 What it takes to install water heater safely
Watch more #TalkingPoint: • Talking Point | Full E...
About the show:
Talking Point investigates a current issue or event, offering different perspectives to local stories and revealing how it all affects you.
================================================
#CNAInsider #CNATalkingPoint #WaterHeater #Heater
For more, SUBSCRIBE to CNA INSIDER!
cna.asia/insideryoutubesub
Follow CNA INSIDER on:
Instagram: / cnainsider
Facebook: / cnainsider
Website: cna.asia/cnainsider

Пікірлер: 469
@anmolagrawal5358
@anmolagrawal5358 Жыл бұрын
Talking Point is one of the best investigative series out there on YT. Keep it up guys! Appreciate all this crucial information that often gets overlooked by a lot of us
@imranbecks
@imranbecks Жыл бұрын
That opening segment with the reenactment of the family that was killed by electrocution. I remember reading it in the news. So tragic. Imagine how traumatised the daughter was when she saw her father collapsing as well. Thankfully she was smart, probably noticed something wasn't right and did not reach in to her father, otherwise she would've been electrocuted as well. I cannot imagine the feelings she went through in the moment. The trauma she's going through now. Just sad.
@junlibunao211
@junlibunao211 Жыл бұрын
Ppppqppppp} pppppppppp
@justusgeorge4080
@justusgeorge4080 Жыл бұрын
Praying praying for the surviving wife who has to raise her children alone. May this tragedy help her come to the knowledge of salvation in Jesus Christ if she’s not a believer already. Praying for peace, strength, and financial support as long as she needs. In Jesus name amen.
@justusgeorge4080
@justusgeorge4080 Жыл бұрын
@@Emsyaz So says who? The Quran is not the continuation of the Gospels or the rest of the New Testament. The Quran cannot substantiate itself according to the Bible ( the whole of Jewish writing in the Old and New Testament.) There is no reference of the seal of the prophets in the Old and New Testament. It is a writing (the Quran) meant to connect itself to the greatness of the Lord but the writing is not from God but from another source. The end of time will reveal this. It is a good thing the end of time is coming soon. The Lord Jesus will not come to smash the graves of Christians but he will come to take them away instead. It is called the Rapture or Catching away. This will be the greatest proof that God favors Christianity and not Islam. Millions or Billions of Christians will suddenly disappear. Hopefully in your lifetime and then you will know what is the truth. I pray you will have conviction and will put your faith in Jesus Christ on that day.
@kylere795
@kylere795 Жыл бұрын
That wasn't the wife, that was the daughter
@mamamememoo
@mamamememoo Жыл бұрын
Guys pls take the debate outside of this lah. Not the right place to argue.
@noramaddy4409
@noramaddy4409 Жыл бұрын
This report has no doubt saved many lives because now people have been informed just how important it is to have water heaters and electrical work done only by a professionally trained installer. Who is checking the official standards are met in the building of new apartment and office blocks?
@kitsura
@kitsura Жыл бұрын
This one will be checked especially for HDB projects. All the add-ons like water heater are the dangerous one.
@dachee
@dachee Жыл бұрын
In my opinion, to protect innocent people, the sale of water heater should be regulated and sold only to licensed installer. The installation fee should be fixed by the appropriate authorities.
@kitsura
@kitsura Жыл бұрын
For all we know next time need to apply a permit to install water heaters. And the authorities will definitely charge a tidy admin fee for it.
@mrtechie6810
@mrtechie6810 Жыл бұрын
Better, inspection
@athenaqilin8354
@athenaqilin8354 Жыл бұрын
Yes, but the licensed plumber is charging $1100 per hour for labor. $6500 to install a Weil McLain heating system, not including equipment and parts.
@dachee
@dachee Жыл бұрын
@@athenaqilin8354In my opinion, It is important that fee for such licenced work be regulated and standardized to avoid overcharging.
@kitsura
@kitsura Жыл бұрын
@@athenaqilin8354 You should see how much a professional engineer charges for 1 signature. At least 5 figures.
@edwardlee7727
@edwardlee7727 Жыл бұрын
Really educational. For those who are renovating their houses, you never know if the ID is using licensed electrical or plumbing workers.
@faridsoc
@faridsoc Жыл бұрын
true.. worst is the charge you super high but using non license contractors..
@alexh9401
@alexh9401 Жыл бұрын
Most renovation electricians are not licensed, usually only the boss is licensed. I have seen joints by twisting and even disabling of earth wire😮
@kitsura
@kitsura Жыл бұрын
Most of them aren't, the shortcut way is to get a licensed one to inspect after installation. Like the person mentioned, 9/10 probably skip this step as well. Getting a licensed electrician (and likely plumber) is very expensive.
@ksy6177
@ksy6177 Жыл бұрын
Wtf i was just thinking about this few days during my home renov. I must see this. Coincidence
@IAmThe_RA
@IAmThe_RA Жыл бұрын
Even some licensed pros do a poor job, I have seen many. If your hands are good learn the trade yourself. Being an electronics engineer, I would not trust any other person to wire my home be it a licensed electrician or an electrical engineer.
@cybergod77
@cybergod77 Жыл бұрын
Excellent education on this matter. I feel authorities should impose penalties on unlicensed plumbers and electricians
@Time4Peace
@Time4Peace Жыл бұрын
For electrical installation of water heater, there are at least conditions to consider: 1. Minimum standards for installation of both storage and non-storage heaters to be well communicated to water heater vendors and their contractors. 2. Qualified electricians to do the installation. Requiring a qualified electrician for every installation, while still highly recommended, may not be the most practical measure, given their availability and costs. As many of the shop contractors specialize in such installation and are almost doing it everyday, they are in a position to comply if the minimum standards are clearly communicated with penalties for non-compliance laid out. Surely something can and must be done to reduce the number of death by electrocution from water heaters.
@duck_that_quacks
@duck_that_quacks Жыл бұрын
If the Residual Current Device/GFCI (one of the BIG breakers) is working correctly, it can detect leakage of current from live to ground, and it will automatically trip in these cases, protecting the user.
@IAmThe_RA
@IAmThe_RA Жыл бұрын
@@duck_that_quacks RCBO
@Time4Peace
@Time4Peace Жыл бұрын
@@duck_that_quacks You are right. But it's always go to have additional precautions. When appliances are added beyond capacity, circuit breakers often get tampered with and that line of defense may get breached.
@lzh4950
@lzh4950 Жыл бұрын
@@duck_that_quacks Read that the house where the electrocution occurred was built (in the mid-70s) back when residual current devices weren't needed as higher-current appliances e.g. water heaters, A/C were less common back then
@peterpan9785
@peterpan9785 Жыл бұрын
This is like the best programme ever its informative, and educational and not to mention Steve as the host is the perfect match - i wonder why Insider has so little views/likes . .
@zekt98arius
@zekt98arius Жыл бұрын
there could be people holding off because of negative perceptions from various troll and disparaging comments left on CNA's or even Straits Times' postings
@pyt6631
@pyt6631 Жыл бұрын
​@@zekt98arius u've verbalised my thoughts eloquently. Some of those troll (or genuine) replies can be quite abusive in nature too.
@tayboonl
@tayboonl Жыл бұрын
I learnt so much from this episode ! I was most impressed that the demonstration of the vast dangers by using electrical cabling that cannot support water heaters. Thanks to everyone whom produced this !
@truth.speaker
@truth.speaker Жыл бұрын
The sad thing is that the apartment was relatively new looking. Could it be that a licensed electrician was saving money by using substandard cable? We have no idea who installed it.
@muhammadkhalilbinabdullate6183
@muhammadkhalilbinabdullate6183 Жыл бұрын
Brilliant, informative and direct. Thank you for doing this episode. 👏
@raymondlow393
@raymondlow393 Жыл бұрын
So besides telling the public to only engage licensed electricians and water heater installation technicians to carry out the job for their homes, what other steps have the government taken to prevent more of such accidents fatal or otherwise from happening ? What kind of penalties is in place if an unlicensed electrician is caught doing electrical installation works for home owners cos if I can remember, there hasn't been any unlicensed electricians being hauled to court for carrying out electrical works. Had I not watched this video, I won't even know of all these potential danger of having a water heater at home, and I am very sure 9 out of ten families are not aware of this too. Thank you very much Steve Chia for sharing this very useful and valuable knowledge with this video.
@RayMak
@RayMak Жыл бұрын
A video we never knew we needed
@kirie-8524
@kirie-8524 Жыл бұрын
Excellent documentary as usual, always interesting and relevant topics to learn more about.
@theunraveler
@theunraveler Жыл бұрын
Good job, really informative!
@simplyleo644
@simplyleo644 Жыл бұрын
Thank you Steven Chia! I've always enjoyed your episodes as they are so educational and close to our daily life. Look forward to you next episode :)
@owenchuarbx
@owenchuarbx Жыл бұрын
As a electrician in training. This is pretty educational. Thanks again
@MissesWitch
@MissesWitch Жыл бұрын
I love that conversation at the end, It's so eye-opening
@lzh4950
@lzh4950 Жыл бұрын
Reminds me when 1 of my university's profs observed that EEE was lacking students, & I was advised by family not to study it as its seen as a more 'sunset' industry (probably as electrician might be seen as a more 'manual' or blue-collar career) that could have more undercutting by workers from developing countries with lower costs of living
@AlvinLee007
@AlvinLee007 Жыл бұрын
Thank you for doing this, Steven.
@owl77
@owl77 Жыл бұрын
I seem a few storage heater didn't connect to the pressure release valve but I made sure mine did.
@3stringsmusic
@3stringsmusic Жыл бұрын
I once had my water heater sharing the same circuit for kitchen sockets and lights and I didn’t even know that was not the proper way for water heater to be installed until HDB came by my unit to inspect. All thanks to my reno subcontractors who was also a plumber😪
@kakiayam60
@kakiayam60 Жыл бұрын
So informative, thank you
@chaozhouzi1984
@chaozhouzi1984 Жыл бұрын
There are errors being presented as facts. Storage water heater has protection against overheating so pressure buildup is not due to this. 2 DP switches for the storage heater does not equate 2 energy source buildup to cause the fire. Pressure relief valve need to test for functionality and not just to ensure drain pipe is not plugged. LEW test for earth bonding, resistivity value of more than 1Ω and LEW claimed it is too high which is incorrect assumption without calculating the impedance. Steve your heater wiring of 1.5mm² may not be undersized ask your LEW to check against the conductor table in SS638. Please check against the correct table. Mr Wang stated water heater draws a current of 14 to 20A. He needs to clarify that he is referring to storage heater and not single point instant heater, subsequent images show man showering using instant heater. The cable used to demo it heating up, he neglect to state cable is undersized.
@mrtechie6810
@mrtechie6810 Жыл бұрын
Good comment. Our storage heater is only 10 amperes (at 240V).
@aiqinhai1
@aiqinhai1 Жыл бұрын
Thank you Steve for doing this episode.
@jchock7503
@jchock7503 Жыл бұрын
The useful revelation that I learnt from this very educational video is that the big tank water heater uses a current much higher than 13 amps which then causes the typical 13 amp house socket and wire to overheat and which then causes short circuit and electrocution of the user.
@sankarayavoo7460
@sankarayavoo7460 Жыл бұрын
Thanks for this video. I'm going to rewire my heaters to new cables. It's not complacency, but just that we sometimes take everything in 'Singapore' as safe. The wear and tear is what we tend to forget.
@jchock7503
@jchock7503 Жыл бұрын
Usually the small wall installed water heater also has its own safety electrical circuit called a ELCB ( Electric Leakage Circuit Breaker) that comes with a small test button on the water heater itself. The person using the water heater from time to time must check that this circuit breaker is working by first switching on the power and then pressing that small button to trip (stop) the electricity supply to the heater. This is an additional safety circuit on top of the RCCB ( Residual Current Circuit Breaker) found in the main electrical board/box of the house or apartment which must also be tested on a regular basis to make sure it is working.
@AutisticMorty
@AutisticMorty Жыл бұрын
Very informative. Thanks for sharing.
@isarayyanmd
@isarayyanmd Жыл бұрын
This is very useful. Thank you for showing this. Great content for awareness. Brunei fan
@obbie1osias467
@obbie1osias467 Жыл бұрын
Following the instruction manual on how to install the water heater will ensure the safety of the installation. Even licensed plumbers and electricians would sometimes consult the installation instruction to make sure that the minimum standard is followed. I've installed several Stiebel Eltron tankless water heaters and found no ensuing problems after many years of use.
@kakaisingsit9808
@kakaisingsit9808 Жыл бұрын
Truly an eye opener
@franciscoroche183
@franciscoroche183 Жыл бұрын
Thanks very informative
@athenaqilin8354
@athenaqilin8354 Жыл бұрын
Just the same, there had been flooding in Texas, some homes have basement, avoid going into basement when flooded as electrical current maybe in the water.
@Alex-qj1xz
@Alex-qj1xz Жыл бұрын
Muito bom material. Gostei dos detalhes!
@ohissitzai
@ohissitzai Жыл бұрын
Insightful series!!! Better be safe than sorry
@rodpettet2819
@rodpettet2819 Жыл бұрын
We purchased a new condominium from a developer in Cebu, Philippines. The first time I had a shower I felt a tingling sensation when I touched the main tap. I spent a lifetime working in the electrical, electronic industry and instantly knew what it was. The development 'electrician' found the condo wasn't bonded to earth or ground. We could have both easily died. ELB should be mandated in all Asian countries.
@stargazeronesixseven
@stargazeronesixseven Жыл бұрын
🙏 Remembered this tragic news of 2020 ... Deepest condolences to the families & friends of the Departed ... May the Departed be blessed to a Better World & Realm ... One of the best gifts are to buy Good & Safe Water Heaters for those still using old & not certified water heaters! Luckily , water heaters are easy to change as they already have the electrical & water pipings installed! Please do ask the water heater supplier to call in their qualified technicians to install the water heater for us to play safe! 🙏 Thank You So Much CNA for highlighting this very important social safety reminder about the dangers of electrocution from badly made water heaters! 🙏
@djangocc3315
@djangocc3315 Жыл бұрын
Very interesting, gives me thoughts now as am close to building my bunglow house in the Philippines
@theonghantan862
@theonghantan862 Жыл бұрын
I m so thanksfull for reminding us Great vedio🎉🎉🎉❤❤❤
@calebwee328
@calebwee328 Жыл бұрын
When the plumber said unlicensed people may not understand the pressure release valve, I felt his "oh no"
@suannasabrinapereira8091
@suannasabrinapereira8091 Жыл бұрын
Oh.... Great information
@tanbenjamin2733
@tanbenjamin2733 Жыл бұрын
Always check the water that comes out from the tank, whether it is clear or contains rust particles. If rust is detected, is a tell tale sign of tank leak. When replacing a water heater, ensure the 15amp electrical 2.5mm cable is safe (flexible) and not stiff. Safety pressure valve(copper) must be new n check rust regularly.
@ssifr3331
@ssifr3331 Жыл бұрын
I have heard of water storage exploding but this is actually the first time I've heard of water heater electrocution. A few years ago, my parents wanted to install electric water heater because they're old and taking cold water bath makes them feel uncomfortable and boiling water in the stove just to take a bath is cumbersome. I opposed that and recommended a gas water heater because electric water heater will need a lot of maintenance, I'm glad I said that. Now, time to check my water heater, jeebus.
@IAmThe_RA
@IAmThe_RA 7 ай бұрын
Being an electronic engineer I am more scared of gas or anything that can explode. Of course I understand your point of view. I don't even trust electricians as not everyone of them takes pride in their job. I wired my own home and everything is a bit of overkilled. Here they suggest the wire size for water circuit is 2.5mm² which is acceptable given that th water heater requires less than 20A but I wire mine with 6mm² which can handle up to 40A current. 😅
@eagleeatsmonkey3621
@eagleeatsmonkey3621 Жыл бұрын
omg ... thanks for the info
@jaggerdoos7592
@jaggerdoos7592 Жыл бұрын
Wow!!!u even became an assistant to an electrician!!!Very informative video !!
@DJNicShogun
@DJNicShogun Жыл бұрын
Very informative episode more needs to be done such as trusted water heater installation contact numbers for contractors
@Ort935
@Ort935 Жыл бұрын
Hope for next is how choose , extension, what cable gauge, lengths, type appliances to use.
@tssnmm
@tssnmm Жыл бұрын
Omg I rmbr that tragedy and it rrly made me uncomfortable cos you wouldn't rrly think much abt being electrocuted by your water heater. I'm glad this episode exists so we would be more aware
@bokbokeh
@bokbokeh Жыл бұрын
This is incredible! Keep them coming!
@johncford3957
@johncford3957 Жыл бұрын
Our water heaters in North America are usually in a utility room , basement , or in the U S south in the attics. I have never heard of anyone getting electrocuted in the shower , also the cabling you are using is way to light for 20 amps at 240 volts.
@eisenklad
@eisenklad Жыл бұрын
using lower gauge/thinner cables is how some electrician save money. i've seen it done to a heated food display unit. the wire from the mains went into a splitter to make sure the wires dont contact each other. but the wires from the splitter to the thermostat and wires joined to the heating elements cables are of 2 sizes too small. as a result, they lasted a week before melting their insulation. having two switches to a single water heater doesnt mean the heater gets double the power. it can draw more current if there's a fault in the heater/wiring. the wife was faster thinking in that case to switch the circuit breaker off. in a fire, switch off the power and gas. you smell gas, shut off any flame and mains power. there's a reason why there's a breaker under your electricity meter outside of apartment. here's another thing to take note of, older HDBs have thinner cables, the circuits design is 15Amps while current new homes is 20Amps and 25-30 amps for high power devices(AC units/ovens/fridges). if you are moving into a 30-40yr old HDB. check the home wiring, either from prev owners or getting an electrician. my current home is 40yrs old, turning on circular Fluorescent lights causes brownout due to how old the circuits are and it has caused my desktop PC to crash.
@lzh4950
@lzh4950 Жыл бұрын
My old house meanwhile is probably 1 of the minority with a 15A power point in the laundry yard (so the pins are circular instead of rectangular) for older washing machines, but newer ones draw 13A instead & thus use the more common rectangular 3-pin plug (BS1363). So when my family changed to a newer washing machine, we had to change to a 15A plug too
@burberryman508
@burberryman508 Жыл бұрын
Thanks to this episode, steve. I almost got a cheap installer to install my water heater.
@andyhooutdoors
@andyhooutdoors Жыл бұрын
I just feel that a law should be passed making it mandatory for contractors to engage only licensed electricians and plumbers. But then I wonder if this might be possible at all considering that only a small percentage are licensed?
@marvint480
@marvint480 Жыл бұрын
But it isn’t. License workers aren’t valued in our society because EMA haven’t done enough to regulate Non-license workers with sufficient protection or penalties.
@franklee8032
@franklee8032 Жыл бұрын
EMA should make installation information freely available, instead of hiding it in a black box.
@marvint480
@marvint480 Жыл бұрын
@@franklee8032 what do you mean by freely available? This itself is a trade that requires years of education and experience.
@slowcyclist4324
@slowcyclist4324 Жыл бұрын
@@franklee8032 the information is freely available. The ability to properly apply it though, that’s an entirely different matters. And that’s where regulations and certification comes in.
@franklee8032
@franklee8032 Жыл бұрын
@@slowcyclist4324 You mean information like the one provided here? www.ema.gov.sg/Electrical_Safety.aspx The link above does not provide information such as wire gauge sizing guide, grounding resistance, fuse/breaker sizing information, and so on. Actually electricity is not a difficult topic to understand, especially in a residential setting.
@stevenlim9640
@stevenlim9640 Жыл бұрын
you are right, 90% water heater electricians are old, or low-educated, unqualified, improperly trained to install water heater, but sg gov just keeps quiet. i twice asked gov town council to recommend electrician repair heater i one instance, they were not cheap, in another instance, i saw the two 50yo uneducated singaporean uncles did the installation, i told myself i do not want to see them again, they used thin copper wires, 40core, to cut cost, not the 70core and cut time, cut corner! so angry !
@pyt6631
@pyt6631 Жыл бұрын
Stuff related to renovation/repairs are generally a very grey area. While regulations are in place, from the homeowner standpoint we may also be none the wiser whether the contractor is legitimate or not. Even for fire rated doors (supposedly a regulated thing) homeowners may also not know whether the label is legit , personally I did not receive the label..
@Indpendent01
@Indpendent01 Жыл бұрын
My 20gallon 120v hot water heater was installed on 240v power and finally failed after 1.5 years in operation. The hot water just stopped one day. Now working with original installers, which are just plumbers, to rectify the situation with a proper 240v hot water heater. All the wiring at least looks proper gauge though.
@efaizariff3145
@efaizariff3145 6 ай бұрын
The same things happened in Malaysia. A Japanese couple was electrocuted due to ELCB malfunction. RCCB with 10mA leakage breaker is a must.
@That7Days79
@That7Days79 Жыл бұрын
Water heater storage tanks now are installed with pressure relief valve.
@samasan7027
@samasan7027 Жыл бұрын
Previous my renovation contractor used poor quality wire to install my water heater . Keep on shut down after use a while . Handyman noticed is poor quality wire issue.
@chiakum
@chiakum Жыл бұрын
I was distracted by Steven driving his good old merc! :-D
@fidelcatsro6948
@fidelcatsro6948 Жыл бұрын
im more afraid of technical faults appearing in over 40 yr old mercedes benzes..
@ladyartemis3232
@ladyartemis3232 Жыл бұрын
We've been using our water heater for 14 years. It was manually installed by my father who is an electrician in the Philippines but I'll ask him to check it again cause this gave me anxiety
@clementihammock7572
@clementihammock7572 Жыл бұрын
Steve, next documentary should be Lipo Battery. 😁
@arjelarshed
@arjelarshed Жыл бұрын
it's happened in Malaysia last year too when a husband and wife were electrocuted due to a water heater in Cameron Highlands
@Cheejyg
@Cheejyg Жыл бұрын
Why didn't the 13A fuse break when the water heater is drawing 14A-20A?
@Haikalemyrse
@Haikalemyrse Жыл бұрын
This is really educational . I hope Malaysia also has this kind of story to tell their people
@Haikalemyrse
@Haikalemyrse Жыл бұрын
@Muhammed Ibrahim Md-Vladislav Mah Bayu is individual channel...aku pun tengok channel dia..what i try to meant is national prime media like Tv3 astro ke apa... CNA is a Singapore national news brand...
@Haikalemyrse
@Haikalemyrse Жыл бұрын
@Muhammed Ibrahim Md-Vladislav dlu...skrg xde dah...tv now penuh dgn drama hiburan tk berfaedah
@IAmThe_RA
@IAmThe_RA Жыл бұрын
@Muhammed Ibrahim Md-Vladislav I'd recommend 10mm2
@fidelcatsro6948
@fidelcatsro6948 Жыл бұрын
plenty of cases there too..
@Haikalemyrse
@Haikalemyrse Жыл бұрын
@@fidelcatsro6948 definitely
@rzkysyz
@rzkysyz Жыл бұрын
Ha! A licensed electrician and plumber. Sounds like a pipe dream here in Indonesia. But nice info. Wished I knew this when I was building my house.
@harryklass1252
@harryklass1252 Жыл бұрын
good information in this video. Me, i use a gas heater.
@s._3560
@s._3560 Жыл бұрын
Not only that, street lights also have electrocuted people in Singapore. Please look into that as well.
@kobeleonard148
@kobeleonard148 Жыл бұрын
Now the question is why do you need a water heater in a tropical country that got same temperature all year long 😂
@GGgoldspear
@GGgoldspear Жыл бұрын
I feel that the regulatory authorities have to check and make sure ALL renovation installers need to check and give a certificate of good condition on electrical works...including the use of good quality wires and ECBs. For the vast majority of people this I not easy to check or understand. So just like the use of Gas connections and the need for a certified person to check and give a go ahead...the electrical works must also be checked by HDB approved, independent certified checkers....
@ellee2937
@ellee2937 Жыл бұрын
U didn’t ask after how many years should change house wiring? Or water heaters? Thanks for interesting & educational topic 👍🏻
@pcno2832
@pcno2832 Жыл бұрын
3:48 I would expect either the fuse or breaker to trip if enough current was leaking to make the earth wire live; I wonder if the earth connection itself was a bit weak. Maybe a ribbon-style cord would be less prone to this kind of leakage, since the wires would be running parallel instead of twisted together. One other thing that has compromised earth connections in recent years has been the use of plastic piping. With metal piping and fixtures, nearly all the plumbing had its own connection to the earth despite any wiring shortcomings, but now the that path would be intermittent, depending on whether the plastic pipes are full at the time. The metal water main in my father's house was replaced with plastic a while back and the installers just left the earth clamp hanging, effectively de-grounding the wiring of the whole house. It was only when I went to sell the place, after my father had died, that I noticed this condition and installed a grounding rod to restore the connection to the earth.
@dachee
@dachee Жыл бұрын
It was mentioned that the handyman plugged up the pressure relief outlet. This is an unfounded accusation!
@xJayteee
@xJayteee Жыл бұрын
My question is this. I've always wondered what's the point of a Fuse in the 3 pin plug? Fuses generally are meant to prevent this kind of things no ? Once current draw exceeds 13amps , it's supposed to break internally , severing the connection and preventing a short . In this scenario , the wires already fused and connected to each other and STILL the fuse did not do anything when it is supposed to when the current draw exceeded 13amps.
@lucretius8050
@lucretius8050 Жыл бұрын
I believe those 3 pin installs purposefully bypass the fuses, water heaters will to draw more than 13A so the standard usage would have already cause trips. Additionally it is likely RCCB was also bypassed for the first case as electrocution by leakage didn't trip the breaker causing subsequent electrocution.
@xJayteee
@xJayteee Жыл бұрын
@@lucretius8050 RCCB yes , Higher chance of getting bypassed by 'electricians' , 3 pin plugs however no. In the test that is shown in the video where he launches a extreme load test , You can see the fuse is still in the plug and yet the plug overheated to the point where even the wires melted which means the fuse did NOTHING to stop it. I've had multiple melted plugs before and this question has always confused me as to WHY is the fuse not preventing anything. Only when melt until short circuit then the breaker trips ? A fire would've started before it trips.
@lucretius8050
@lucretius8050 Жыл бұрын
​@@xJayteee​From my knowledge the fuse should have tripped (or maybe i just have poor knowledge), melted cables can also be caused by frayed core wire, poor quality, using thin cables to over extend, cable wear, poor connection which does not actually increase the actual load. It is melting cause it can't hold 13A load so it is "breaking" before the fuse.
@kelvinlee7226
@kelvinlee7226 Жыл бұрын
In some cases, there are electricians that would just wound copper wires where the fuse should be. This bypasses the safety features of the fuse. In some cases, the wires were under-gauged, being unable to even carry 13 amps in the first place. So wires giving up (burning) before the fuse gave way. (you can see this in the check the electrician in the video did with the ohm-meter, and got the resistance reading) I've done solar work as a hobby, I have an EE background, but for serious work, I'd still bring in a license electrician any day, pays to be safe. In some cases, an unlicensed electricians could also invalidate your insurance policy, so makes sense to get a proper electrician and plumber to sort your devices out. Stay safe folks.
@xJayteee
@xJayteee Жыл бұрын
@@kelvinlee7226 Probably then . Idk. I've tried some experiments , trying to overload the plug so I can try to get the fuse to pop but was to no avail .I ran a 18amp load through , and the plastic around the pins melted before the fuse did anything so I still don't understand what the purpose of it is. If you're willing to share , years back I wanted to try solar power as well. But I couldn't figure out how to connect it to the grid power so I could switch inbetween grid and solar. So I had to run a inverter from my powerbank , to my inverter and connect it to a 3 pin plug to my select few appliances. Can you share how you ran it along with the grid?
@mrtechie6810
@mrtechie6810 Жыл бұрын
Permanent high current installations should be directly wired. If the plug is loose in the socket, or corroded, it will heat up, even at lower currents. The fuse offers no protection against this. Nor does it protect against loose wires nor any bad contact -- that will overheat and cause fire. All connections should be inspected, and the loop tested for low resistance or checked under load with an infrared camera to verify there is nothing overheating.
@xonx209
@xonx209 Жыл бұрын
Checking with an infrared camera is a good idea, not just for water heater, but all electrical wires and outlets. You don't need to be an electrician to do this since using infrared camera is not dangerous.
@kelvinteoh9058
@kelvinteoh9058 11 ай бұрын
Hi Steven, I recently received a letter from HDB informing about plans to upgrade flats with older electrical systems to those with RCCBs. This was due to the case where a family of 3 were electrocuted from an incorrectly wired water heater. I went back to read the judges verdict and was surprised that the flat had already been upgraded with an RCCB during the HUP to add a utility room in the kitchen. Unfortunately, the RCCB only served the utility room. Although not clear, the report seemed imply that the electrician had only routed wires from the RCCB protected circuit to the utility room, essentially creating a distribution box with a dual electrical system. This was in 2003 after RCCBs were mandated in all new HDB flats. I am not sure if the EMA has electrical codes requiring newly installed RCCB must cover the entire electrical system rather than just a single circuit, so cannot comment if any rule was broken by the electrician. I wrote to EMA to enquire about the possibiliy of my home electrical system being upgraded as my home is fitted with an ELCB which predates the RCCB, and wanted to know if we would be included in this upgrading programme. Sadly, I was informed that we were not included as the RCCB is merely a renamed ELCB. EMA is not completely wrong of course because the original ELCB, which is a voltage sensing device that detects voltage leakage through the ground wire, whereas the RCCB, which was first called the current-operated ELCB was renamed to prevent confusion amongst electricians. However they differ drastically in operation and should not be confused with each other. Whilst RCCBs can detect any leakage in current (either through a short circuit in groung wiring or an alternative ground return such as through an object or person during an electrocution) the ELCB is severly limited to just leakage through the ground wire (which modern appliances tend to lack). Perhaps Talking Point could explore this topic further in your next episode? It is likely that a larger percentage of homes are currently installed with less protective ELCBs than RCCBs.
@IAmThe_RA
@IAmThe_RA 7 ай бұрын
Water heater circuit must be required to protected by an RCBO.
@ohmteam7
@ohmteam7 Жыл бұрын
should make a habit of checking home RCCB or ELCB at home main circuit breaker box. provide protection against electric shocks or leakage.
@kgpcodes
@kgpcodes Жыл бұрын
I use touch screen & the right circuit breaker. I think you can have an inline circuit breaker called RCBO for this. This is required by Australian standard. They lose license without doing this.
@supeskrim
@supeskrim Жыл бұрын
No, if you have proper grounding and RCD (some old folks call it ELCB) circiuit properly installed in your hose/building. I am very surprised if SG don't have that safety requirement for new building/house. In AU they have DOUBLE RCD requirement for every new build. You need to fire/sue your whatever ministry in charge. Usually you install RCD before MCB to save cost because RCD cost 3-5 times as much as MCB fuse.
@stevenlim9640
@stevenlim9640 Жыл бұрын
you are right, 90% water heater electricians are old, or low-educated, unqualified, improperly trained to install water heater, but sg gov just keeps quiet. i twice asked gov town council to recommend electrician repair heater i one instance, they were not cheap, 75yo, and he came and 'bundle and twist to tie-up' the three colour wires in just 5minute and after he left, it burst with a pop sound and fire smoky smell ! i was so angry but town conucil insisted nothing to do with them they dont take any responsibility... i had to find private again
@kun1477
@kun1477 Жыл бұрын
this happen more than 1 time in singapore.... i bath with cold water for 20years
@dchan93
@dchan93 Жыл бұрын
Lol
@rosalynnchow5057
@rosalynnchow5057 Жыл бұрын
It will boost your immune system and improve metabolic rate.
@rosalynnchow5057
@rosalynnchow5057 Жыл бұрын
@@Emsyaz I been taking cold showers.
@jamesyap3562
@jamesyap3562 Жыл бұрын
Water heater sellers usually include installation as a package. When they suppressed contractors labor charges, there's where things go wrong.. Wire size and required water piping will be skimmed off to cover cost. If the resident can find their own qualified contractors, whatever charges imposed is nothing when safety and long term solutions is in question. Installation is less than 5% of the heater purchased and customers usually pay up. As mentioned in the video, qualified contractors are not easily available or their schedule is too packed to entertain immediate attention. Better yet. shop owners must bundled all the wires, piping and circuit diagrams for proper installation. For my personal instant unit, my RCD is one foot away from the heater. The heater unit itself (consumers must know) also has a CB but the additional RCD is rated at 3mA. Lastly, don't buy metal cased instant heaters, metal shrouded flexible hose and metal shower units. to reduce electrocution risk. Children are prone to splash the unit with water during bathing time. Plastic casing is best.
@franklee8032
@franklee8032 Жыл бұрын
Rather than monopolise the market by turning safe electrical installation into a black box, the authorities should make the information needed for safe installation free and widely available so that customers can protect ourselves from shoddy electricians, licensed or not.
@Samlowkiapeng1888
@Samlowkiapeng1888 Жыл бұрын
Information is always free and available. Not many people even know you check EMA for whether a worker is licensed
@MrNamesNoMore
@MrNamesNoMore Жыл бұрын
But licensed electrician always charge a limb and a leg, thinking that it is tok cai tao day. I was once quoted $500 to change 1 water heater + wiring, when the material cost is at most $200.
@amateurcraft
@amateurcraft Жыл бұрын
I hired my ID to handle everything. Now i am scare whether they got the license electrician to do the proper job or not.
@P53eud0nym05
@P53eud0nym05 Жыл бұрын
No way to know. High chance ID will hire unlicensed cos cheap but jack up the cost & claim its licensed so more expensive. My aircon was leaking so ID sent his contractor down. ID charged me a certain amount. Later contractor sent receipt to me. I found out ID almost doubled the fee! Called him to demand & explanation & after hours of delays, he claimed his admin staff sent wrong invoice. Ya right! 🙄 If the aircon contractor didn’t send me the receipt, my ID would happily inflate the cost & act blur!
@ezekielk.3629
@ezekielk.3629 Жыл бұрын
You shouldn't have let the ID handle everything and even if they handle everything it must be communicated via a clear channel for every installation and official invoices of the job must be handed over before & after completion of works. For e.g. my home electric fitting and works are all done up by certified electricians that have done past projects for both commercial & home.
@ezekielk.3629
@ezekielk.3629 Жыл бұрын
@@P53eud0nym05 luckily my AC Contractor was a referral by my ID not direct hired by the ID to do the AC works
@kitsura
@kitsura Жыл бұрын
@@P53eud0nym05 IDs are glorified main-con. Their main job is to con ppl of money. A real architecture firm will have proper project managers and site foreman overseeing the entire project. Do you think the Sheng Siong owner and other GCB landlords have to worry about whether their electrical or plumbing is handled by a licensed personnel? The lawsuit and claims would more than cancel out their earnings if they try to cut corners.
@fidelcatsro6948
@fidelcatsro6948 Жыл бұрын
they will alibaba with your licence ID ..
@simonlinser8286
@simonlinser8286 Жыл бұрын
water is a poor conductor of electricity unless it has some amount of salts in it, pure water at least is not a good conductor. most tap water at least in the US is not very conductive, but with the 7 to 14 amp draw of the water heater, it's still likely to conduct some current through the water...
@drans2007
@drans2007 Жыл бұрын
I don't know if its available in Singapore, in Taiwan they sometimes use LPG to heat the water, its instant heater but uses gas.
@dereth
@dereth Жыл бұрын
Very informative! Hmm... how about Gas Water Heaters? Any information on those?
@leodass
@leodass Жыл бұрын
Better safe than sorry!
@BenyaminLimanto
@BenyaminLimanto Жыл бұрын
Electro boom should be hosting this video..
@fidelcatsro6948
@fidelcatsro6948 Жыл бұрын
yes that fella is a walking Nikola Tesla (Menthol Lights)
@markangelocaban915
@markangelocaban915 Жыл бұрын
Heaters are equipped with thermostat to prevent over temperature.
@minyuan86
@minyuan86 Жыл бұрын
I once get a license electrician to my house to install some new points. he got his bangala to some over and install... after that the bangala just take some photos for his boss to approve is that legal?
@jeromeheah
@jeromeheah 11 ай бұрын
how long should i heat up the water tank, how to know the water in it aleady heated up and ready to shower?
@skyfeelan
@skyfeelan Жыл бұрын
8:27 I was glad I watched technology connection channel so I understand how RCCB work lol
@p-niel5328
@p-niel5328 Жыл бұрын
Install a GFCI connected to your water heater to solve water heater fault issue.
@30mAkills
@30mAkills Жыл бұрын
Yearly meggering will definitely avoid these types of tragedies which are caused by insulation failure.
@BBme
@BBme Жыл бұрын
As an engineer, the installation is still not satisfactory and still a shock hazard. This is the major difference between hands on engineer and pub licence electrician and plumber. It's sad to say, the ones who really hands on are those foreign workers and the licensed person just look. Lots of things must use hands to check or done but they just only using sight to check.
@goodhealthishappiness
@goodhealthishappiness Жыл бұрын
16:24 nice name
@lbcck2527
@lbcck2527 Жыл бұрын
I just watched this video and there is mentioned that water heater current is between 14 to 20 amps. Here is where I am confused, why 1. does the 13amp fuse in the plug not blow out ? 2. the ELCB (earth leakage circuit breaker) does not trip ? Here, the 2 "fail safe" mechanisms typically installed in our flats have themselves failed and killed the occupants.
@darren424242
@darren424242 Жыл бұрын
The time a fuse takes to blow depends on how much of an overload there is, the higher the overload the faster it blows. A small overload will still blow the fuse eventually. An ELCB/RCCB will only trip when there is an earth leakage fault, it will not trip for an overload fault. A CB is the device that protects against overload faults so that is why you typically use both in an electrical installation. A RCBO combines both earth leakage and overload protection into a single device.
@bowlampar
@bowlampar Жыл бұрын
Water heater consumed large amount of electric current, it should be installed in a dry storage room preferably far away from bathroom or wet surrounding. Spend a bit more on pipe extension is better than losing your life trying to save a few bucks.
@impactodelsurenterprise2440
@impactodelsurenterprise2440 Жыл бұрын
Schools should make it mandatory to under how electricity works in general and what should be done in case of accidents like this.
A simple water heater is more clever than it seems
22:52
Technology Connections
Рет қаралды 1,9 МЛН
你们会选择哪一辆呢#short #angel #clown
00:20
Super Beauty team
Рет қаралды 19 МЛН
Became invisible for one day!  #funny #wednesday #memes
00:25
Watch Me
Рет қаралды 52 МЛН
Жайдарман | Туған күн 2024 | Алматы
2:22:55
Jaidarman OFFICIAL / JCI
Рет қаралды 1,7 МЛН
How Healthy Are Durians, Really? | Talking Point | Full Episode
23:24
Burnout - When does work start feeling pointless? | DW Documentary
51:56
DW Documentary
Рет қаралды 1 МЛН
Indian Elections: Last Week Tonight with John Oliver (HBO)
23:25
LastWeekTonight
Рет қаралды 3,8 МЛН
The Most Confusing Part of the Power Grid
22:07
Practical Engineering
Рет қаралды 1,3 МЛН
How the Titanic Was Found
22:19
neo
Рет қаралды 539 М.
How Safe Are Our Vegetables? | Talking Point | Episode 43
22:21
CNA Insider
Рет қаралды 124 М.
The Missing Cryptoqueen: Dead or Alive? - BBC World Service Documentaries
53:54
BBC World Service
Рет қаралды 1,6 МЛН
你们会选择哪一辆呢#short #angel #clown
00:20
Super Beauty team
Рет қаралды 19 МЛН