How I Wire 2 Inverter To A Common Battery Bank.

  Рет қаралды 17,053

Bobby's Solar Homestead

Bobby's Solar Homestead

3 жыл бұрын

This is how I do this. It's not hard to set this up after you know a few things. This works well where you need more power off-grid than one inverter can push.

Пікірлер: 93
@DavidPozEnergy
@DavidPozEnergy 3 жыл бұрын
Thanks for taking the time to make drawings.
@bentleyjarrard885
@bentleyjarrard885 3 жыл бұрын
Good explanation. Bus Bars are the way to go when making multiple connections, much cleaner. You most likely mentioned this previously, a good source for bus bars is Midnight Solar. They seem to have a good selection for different types of situations.
@yankey4
@yankey4 3 жыл бұрын
Yes thank you!! God Bless..
@ChileExpatFamily
@ChileExpatFamily 3 жыл бұрын
Excellent explanation on how to. Thanks Bobby. Jim
@yankey4
@yankey4 3 жыл бұрын
Thanks brother. We where just looking how you guys are doing.
@NormanMcGregor
@NormanMcGregor 3 жыл бұрын
Good advice Bobby!
@seller559
@seller559 3 жыл бұрын
Well done. Thank you.
@lifeinfernglenvalley6088
@lifeinfernglenvalley6088 3 жыл бұрын
This is great! Very easy to understand! I am working on a off the grid style house and am just getting started on upgrading my solar, any thoughts on running the inverters into a regular fuse box and to house wiring?
@checkingoutgypsymike2075
@checkingoutgypsymike2075 3 жыл бұрын
Thanks for the videos.
@yankey4
@yankey4 3 жыл бұрын
Welcome. Hope this helped.. God Bless.
@user-nl7fz9fx3c
@user-nl7fz9fx3c 8 ай бұрын
And also I'll really like you to do a video on how you program the inverter after wiring the system. What are the things that need to be set on the inverter.. and am sorry if these questions are basic am just starting with solar installation and am trying to learn as much about it
@JOHNG104A
@JOHNG104A 4 ай бұрын
I have two inverters and two sheds each has it's own inverter and do not mix AC output, can I connect to the same battery bank for input volts to the inverter?
@yankey4
@yankey4 4 ай бұрын
Yes ! As long as the DC volts In for each is the same and the AC is not mixed. Your 100% fine I did this for 8 years. It's it's very common. Hope this helps. God Bless.
@rontech34
@rontech34 2 ай бұрын
Hello how many Amps should I charge a 24v 600ah Lipo4 battery bank ?
@TheOffGridTinyHouse
@TheOffGridTinyHouse 3 жыл бұрын
Good to know thanks brother :) God Bless
@yankey4
@yankey4 3 жыл бұрын
Welcome brother. PS Thanks for the water videos. Showed my buddy who's living in a small cabin. He could have running water year round.
@stefanchastain3031
@stefanchastain3031 2 ай бұрын
I'm trying to put 2 Power inverters on 1solar charge controller with 2 Battery that have 35ah each
@DIYwithBatteries
@DIYwithBatteries 3 жыл бұрын
Nice video Sir :)
@yankey4
@yankey4 3 жыл бұрын
Thank you!!!
@checkingoutgypsymike2075
@checkingoutgypsymike2075 3 жыл бұрын
I watched your video with your big solar array, and why they should be sized together for the different output's and shading zones. Very informative. I will be building im thinking 2 battery banks for a offgrid boondocking cargo trailer. Ill have enough room to put 4 panels on the roof, with a diy tilting frame. I don't think ill need to put them on seperate controls for shading, but want to make two banks for the weight issue. Ive watched a few videos on building banks, im thinking the bms and smart shunt will be the way i go for battery safety. I have 8 lifepo4 280ah 3.2 batteries coming, do you have any advice on if they should be/and how to wire the banks 12v banks and wire together for 24v? I am a newbie on solar and this will be my first build. So i don't want to waste money on going 2 12volt systems and controls if i should be building two boxes and wiring them as one with one set of charge controls for a 24v system. If that makes sense lol. I spent to much time watching videos, i had to take a break. But if i remember correctly all the systems were 12v i watched, and remember something about 24v being more efficient. Thanks if you have any suggestions, God bless brother!
@checkingoutgypsymike2075
@checkingoutgypsymike2075 3 жыл бұрын
For clarification. I will be putting a pvc pipe system on roof around the solar array frame for shower water, washing clothes, dishes ect. If im not parked near a flowing water source, ill be taking water jugs and a battery bank with a pump and filter for water collection instead of hooking up trailer and moving to it to fill the 40 gallon pipe storage system. It may turn out it'll be easier to just have a agm battery for that, instead of un hooking a bank, but will still be making two banks for the weight issues. If i have a failure in one bank of any kind it'd be nice to still have one working if say a controller or shunt went down.
@yankey4
@yankey4 3 жыл бұрын
@@checkingoutgypsymike2075 Will you email me at yank_1978ATyahoo.com ? I can help beater there..
@edt6133
@edt6133 3 жыл бұрын
Thanks Bobby Great video! Just wonder if you can have enough solar to power 240 volt motor?
@yankey4
@yankey4 3 жыл бұрын
Yes why not. I run all kinds of stuff from solar. 90% of my 120 volt loads run 24/7 off-grid. Thanks and God Bless.
@tcgauldin
@tcgauldin 3 жыл бұрын
Thanks Bobby. Wouldn’t it still be the same amount of power going into the battery regardless of how the PV is wired. If it is all going to one charge controller or two or three charge controllers for that matter, isn’t all of the power flowing to the same common battery? The exception would be as you noted , if different sized PV existed and wired to different charge controllers.
@yankey4
@yankey4 3 жыл бұрын
Yes your right. But as you know. This is just needed when you have different sized PV going to one bank. It's not ever the best thing to mix PV. On the same CC. Unless the electric values are all the exact same of the PV. If not the lower value panel will pull the rest of them down to it. Seen this happen where guys had 255 watt PV mods and a 245 watt mod on the same CC. He just had 2 of the 245 and 6 of the 255. The max he could get ever was 245. That's with ice and temps of 15F.. At that temps there should have been his max PV going in. But max we could see was the 245. In the case he had 2020 watts of PV. on a average sunny day he would see max 1400 ish watts or so. When we removed the 245 out of the setup. He was getting 1350 + watts on a average sunny day. That's just one that I can recall this min. But seens all kinds of things like this. That one too where so close in watts and Volts. You would think it woulf not been that big of a deal but it was. When we got him a new CC and added those 245 guys on that one he was seeing 400 ish watts from them a day. So just by this few sets his power had gone up about 500 watts + and hr.. That's a crap load of power when your trying to live 100% off-grid. Sorry for all this LOL.. Hope that helps..
@muzurukialexander2964
@muzurukialexander2964 2 жыл бұрын
That's good 👏👏👏👏👏
@mariofsantana3952
@mariofsantana3952 15 күн бұрын
Hi, how are you drawing power from parallel Inverters out of your Power Center in your RV if you have a 30 amp panel? Thank you, Mario
@yankey4
@yankey4 14 күн бұрын
This was in my old home. I was running 1/2 the house on one inviter and 1/2 on the second one..
@offgridwanabe
@offgridwanabe 3 жыл бұрын
Question Bobby are the bus bars in each pic the same bus bars. Some guys say the ripple effect will happen but I never found that.
@yankey4
@yankey4 3 жыл бұрын
Yes sir !! Nailed it!! LOL But yes I have not ever had a bit of trouble running them. Maybe back when using lead batts and they where low on charge. Not with lipos. God Bless brother.
@AGhostInTheMachine
@AGhostInTheMachine 3 жыл бұрын
Can you describe ripple effect and what the concern is?
@yankey4
@yankey4 3 жыл бұрын
@@AGhostInTheMachine From what I know it's this in short and from what I know. May not be right on this. It's when one inverter is pulling a lot of amps and the next one is left with out the amps its needing to do it's job. That's from what I recall.
@yankey4
@yankey4 3 жыл бұрын
This is way you keep the inverters the same size. Also size your battery bank to handle the max loads you can place. I do 120%. So If I know I need to do 4500 watts. Than I size the bank to do like 14KW or more. Even knowing that can't ever happy. Like to have LOADS of head room ..
@offgridwanabe
@offgridwanabe 3 жыл бұрын
@@AGhostInTheMachine As the story goes having 2 inverters on the same battery causes the ripple effect. Ripple is wasted power, and has many undesirable effects in a DC circuit: it heats components, causes noise and distortion, and may cause digital circuits to operate improperly. ... Ripple may be reduced by an electronic filter, and eliminated by a voltage regulator. Or capacitors
@MeironEgger
@MeironEgger Жыл бұрын
Just to make sure I got it right- so if I have for example two inverters of 1500w each, that allows me to use , let’s say, a 2000w appliances?
@yankey4
@yankey4 Жыл бұрын
NO !! This will allow them to both run off the same battery Bank! The AC side will not be tide together. You can do that with high-end inverters. But not the one's that you just plug in an appliance directly to ! Hope this helps some. God Bless
@rajiabdulrahman5646
@rajiabdulrahman5646 2 жыл бұрын
Nice short tutorial. My question goes thus: which among the inverters are we gonna connect the output wire/ load wires to. Or are we connecting the output on just one of the inverters
@yankey4
@yankey4 2 жыл бұрын
That all depends on the inviters. Some you can parallel the out put and some you can't. Mine have a coms board in them. So they can work as a master and slave for the out put. Hope this helps some.
@rajiabdulrahman5646
@rajiabdulrahman5646 2 жыл бұрын
@@yankey4 thank you, the information is helpful. And what type of inverter did you use for your tutorials
@yankey4
@yankey4 2 жыл бұрын
@@rajiabdulrahman5646 I have Mpp Solar inviters. They are 5 years old. Don't think there made now. Mpp Solar still makes and sells a lot. Just maybe not the one's i am running. You can find them on Ebay here.. www.ebay.com/itm/274722868943?epid=10044157048&hash=item3ff6c24ecf:g:QL8AAOSwcU5fvcOT&mkcid=1&mkrid=711-53200-19255-0&siteid=0&campid=5338672413&toolid=11800&mkevt=1 You can shop around for what fits you. But don't buy if not from maximumsolar_usmaximumsolar_us. There are a LOT of fakes. This is the lace that Mpp Solar sells now.. Hope this helps. God Bless
@fisherus
@fisherus 3 жыл бұрын
Bobby, shouldn't the positive and negative cables between the buss bars and battery be equal in length?
@yankey4
@yankey4 3 жыл бұрын
LOL hahaha you kill me. I am cracking up LOL. But YES :) LOL Thanks Needed that today. God Bless brother.
@fisherus
@fisherus 3 жыл бұрын
@@yankey4 Glad to fill your cup full of shits and giggles, brother, yee-haa!
@tawnya0627
@tawnya0627 3 жыл бұрын
Bobby, can I use two different charge controllers? Like a 12 volt AIMS and a 24 volt Outback?
@yankey4
@yankey4 3 жыл бұрын
If your bank is 12 volts and your CC are Mppt CC then it would work but not PWM..
@yankey4
@yankey4 3 жыл бұрын
24 volts or 48 volts This is not what matters its that your CC are Mppt and work with the bank you have.
@tawnya0627
@tawnya0627 3 жыл бұрын
@@yankey4 My battery bank is 24V. One charge controller is an Outback Flex60 and the other is an AIMS 12V. I should have realized that wouldn't work. Thank you, Bobby! (Both CC are MPPT)
@yankey4
@yankey4 3 жыл бұрын
@@tawnya0627 Glad I could help. God Bless.
@randyk2904
@randyk2904 3 жыл бұрын
Can you use different size inverters
@yankey4
@yankey4 3 жыл бұрын
Yes
@hoosiersolarpower974
@hoosiersolarpower974 2 жыл бұрын
Hi Bobby is this considered daisy chaining
@yankey4
@yankey4 2 жыл бұрын
Not that I know. I would think that's where 2 inviters where stacked for more out put.
@zulqikhan592
@zulqikhan592 Жыл бұрын
Can I install the busbar for this issue
@yankey4
@yankey4 Жыл бұрын
Yes it's a smart thing to do. Sorry this comment did not show up. I just found it in spam. Sorry about that. If I can help let me know..
@jeffwerchan724
@jeffwerchan724 9 ай бұрын
👍
@zulqikhan592
@zulqikhan592 Жыл бұрын
Hi Bobby I have 15kv solar system installed.5kv 3 inverter with one power bank but there is issue on 2 inverter.every time 2 inverter beep for overvoltage busbar
@yankey4
@yankey4 Жыл бұрын
Don't think it will help sounds like a setting or trouble with inverter. Or how you have it wired.. I Use buss bars for my 2 inviters.
@zulqikhan592
@zulqikhan592 Жыл бұрын
Thanks for reply bobby sound is not issue.issue is inverter go to shutdown and on screen showing overvoltage busbar.we do the inverter reset
@yankey4
@yankey4 Жыл бұрын
@@zulqikhan592 Sorry I was using my phone to send last reply. Not saying it's a sound thing. It sounds like to me that you have a bad inverter. Or your wiring is not right.
@zulqikhan592
@zulqikhan592 Жыл бұрын
Issues in inverter u said right 👍👍👍
@zulqikhan592
@zulqikhan592 Жыл бұрын
Thanks dear
@birdmann144
@birdmann144 2 жыл бұрын
Can you put two inverter to one combiner box?
@yankey4
@yankey4 2 жыл бұрын
yes
@birdmann144
@birdmann144 2 жыл бұрын
@@yankey4 does both inverters have to be the same? I have one hybrid the other not hybrid, both 3000W
@yankey4
@yankey4 2 жыл бұрын
@@birdmann144 Brother Email me and Phone # at Yank_1978ATyahoo.com. I will help you beater like that. God Bless
@kylecampbell6953
@kylecampbell6953 Жыл бұрын
Does it matter if they are different size inverters?
@yankey4
@yankey4 Жыл бұрын
nope not at all. Just use the appropriate wire size and Breakers.
@kylecampbell6953
@kylecampbell6953 Жыл бұрын
@Bobby's Solar Homestead cool, so can I do more the inverters? I bought a portable classroom and want to wire a couple of them to the breaker box that's on the building so I can have power on all the outlets in the building. Do you think that's possible?
@yankey4
@yankey4 Жыл бұрын
@@kylecampbell6953 No you can't have 2 inviters feeding into one braker box. You can but there is a LOT more to this. But if you don't know how to do it you will blow up one or both. Best way to do this is to have 2 braker box. One for each inviters out put. The DC in put from the battery back can be the same as long as they have the same input DC volts..
@kylecampbell6953
@kylecampbell6953 Жыл бұрын
I wish I could show you a picture but it has the 2 hot poles that come down to the busbars/breakers. I can't do one inverter on the left pole and then another on the right?
@yankey4
@yankey4 Жыл бұрын
@@kylecampbell6953 Yes if there not at all combine.. Email me at Yank_1978(AT)Yahoo.com a phone # if in the us and I will call ..
@shawnnn3
@shawnnn3 3 жыл бұрын
What Busbars do you recommend? Or USE. Please email site address Thanks Good video Bobby
@rontech34
@rontech34 8 ай бұрын
Question I have 2 PowMr 24v hybrid inverters 3000w each I have 24v 600ah Lipo4 battery bank can I connect both inverters to the 1 battery bank? But can I connect 4000w solar panels to 1 Inverter to charge the batteries ? The reason why because I don't want to split the panels in half and run another set of wires from my roof down to the garage it's to much work
@yankey4
@yankey4 8 ай бұрын
Yes !00% that is fine. You do not need solar on both inviters. As long as your inviter can take 400 watts of PV it's fine. You can run them both off the same Bat bank. Just can't combine the AC out put of them. With that some can be AC combine. Like mine have 2 PCB bords I can install. This will then combine there AC out put. Hope this helps some..
@rontech34
@rontech34 8 ай бұрын
@@yankey4 each inverter has its own AC output but they are not combined they are separate going to a sub panel on separate legs L1 and L2 but will both be pulling from same battery bank is that ok?
@yankey4
@yankey4 8 ай бұрын
@@rontech34 Yes 100% is fine! That L1 and L2 is cool. I dune that a lot.
@rontech34
@rontech34 8 ай бұрын
@@yankey4 Thank you
@yankey4
@yankey4 8 ай бұрын
@@rontech34 Your welcome my friend. Best of luck! God Bless
@checkingoutgypsymike2075
@checkingoutgypsymike2075 3 жыл бұрын
5:57 you said if we want to add another charge controller to the system, we put up another set of solar panels and wire to number 2 controller. Did you mean to say if we want to add another set of panels? Probably is an obvious misspeak, but i don't know enough to be sure lol. And im guessing if you meant another set of solar panels, and wire them to number 2 controller you'll want to make sure the controller is able to handle the extra volts? Not trying to be a smart butt, im just trying to learn from your videos for my knowledge bank!!
@yankey4
@yankey4 3 жыл бұрын
Right each CC must have it's own set of solar. It's own set of wires from the solar to the CC..
Parallel Inverters - Double the Power Hack!   Part1
18:27
knurlgnar24
Рет қаралды 512 М.
▶️ 2 inverter connect one battery full power 1100 + 1100= 2200w
9:45
electric science trick
Рет қаралды 84 М.
DAD LEFT HIS OLD SOCKS ON THE COUCH…😱😂
00:24
JULI_PROETO
Рет қаралды 16 МЛН
Fast and Furious: New Zealand 🚗
00:29
How Ridiculous
Рет қаралды 24 МЛН
A teacher captured the cutest moment at the nursery #shorts
00:33
Fabiosa Stories
Рет қаралды 40 МЛН
How Many Batteries For a 3000W Inverter?
6:09
Cleversolarpower by Nick
Рет қаралды 819 М.
How To Wire Multiple Charge Controllers To One Battery Bank
11:06
Bobby's Solar Homestead
Рет қаралды 60 М.
Off Grid Solar Power System Battery Bank Sizing! You MUST Do This!
12:13
Country Living Experience: A Homesteading Journey
Рет қаралды 153 М.
How to Wire Multiple Solar Charge Controllers into a DIY Camper Electrical System
10:27
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 218 М.
How to Charge Batteries in Parallel With Different Capacity
8:22
Cleversolarpower by Nick
Рет қаралды 81 М.
Growatt Inverters Parallel Connection
8:49
EcoHouseThailand
Рет қаралды 37 М.
AMP HOURS EXPLAINED (amp hours vs watt hours)
10:59
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 891 М.
Top 10 Beginner Mistakes When Building a DIY Solar System
17:39
DIY Solar Power with Will Prowse
Рет қаралды 1 МЛН
БАТЯ И ТЁЩА😂#shorts
0:58
BATEK_OFFICIAL
Рет қаралды 4,4 МЛН
Stay on your way 🛤️✨
0:34
A4
Рет қаралды 16 МЛН
Czn Burak vs Argenby Which sigma is better?
0:19
ARGEN
Рет қаралды 11 МЛН
Притворилась БЕРЕМЕННОЙ 😱 #shorts
1:00
Лаборатория Разрушителя
Рет қаралды 4,8 МЛН