No video

How to Calculate Chord Forces And Professional Engineering Insight

  Рет қаралды 6,052

Kestävä

Kestävä

Күн бұрын

Part 3 of our FULL BUILDING design example. We tackle calculating, engineering, and designing our diaphragm chords. This is a full wood / tilt-up design example under seismic design criteria. I also discuss some insight on what the professional engineering field is like and what to expect.
Imagine what 5000 engineers can accomplish collectively... lets find out together.
👇 SUBSCRIBE TO KESTÄVÄ ENGINEERING’S KZfaq CHANNEL 👇
/ @kestava_engineering
👇School of PE Affiliate Link for those Wanting More Material!👇
www.schoolofpe...
For business inquiries email: kestavallc@gmail.com
Connect with me on LinkedIn 👇
/ richard-racz-pe-620b1792
If you Want to Tip Through Brave Browser - I'm a Verified Creator! 👇
(I am not affiliated or receive compensation from Brave)
.
.
.
.
.
.
.
.
.
Disclaimers: Richard Racz, P.E. does not hold the title "structural engineer". Any claim of it in the videos or descriptions is unintentional and is superseded by the title "civil engineer" in the states of MA and OR.
The Kestävä KZfaq page is intended for informational purposes only. Nothing contained in, or provided through, this KZfaq page is intended to constitute advice, or to serve as a substitute for the advice of an engineering professional. Any reliance you place on such information is strictly at your own risk.
Under no circumstances will Kestävä be responsible or liable in any way for any content, including but not limited to, any errors or omissions in the content, or for any loss or damage of any kind incurred as a result of any content communicated on this KZfaq page.
#seismicdesign #structuralengineering #kestavaengineering

Пікірлер: 27
@mariagonzalezbracho2315
@mariagonzalezbracho2315 Жыл бұрын
Eres asombroso explicando todo esta muy bueno
@jeffreycastillo32
@jeffreycastillo32 2 жыл бұрын
I would love to see more kestava construction! Keep up the good work!!
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
Thanks for the feedback Jeff! Will do! - and i got your email and am writing a response back now!
@CavernYogi
@CavernYogi 5 ай бұрын
Great video w/ insights to application that really helped me understand the process and implementation!
@narathipkhanhansuk9469
@narathipkhanhansuk9469 2 жыл бұрын
Thank you 🙏 Rich. I really appreciate your help.
@user-ds7op9wn8w
@user-ds7op9wn8w Ай бұрын
Hi! This is some great stuff. I did my chord reinforcement for previous projects in the composite deck itself. What I was looking for is for a condition where lateral system is braced frames but spaced throughout buildings rather than at the perimeter walls. Wondering if we would place our chord reinforcement at braced frames.
@bilalelshal7939
@bilalelshal7939 2 жыл бұрын
Great content. I liked the detailing much
@josephhoffmayer5180
@josephhoffmayer5180 2 жыл бұрын
Move away from block out panels and look to using a steel channel ledger topped with a wood nailer. The channel is easier to weld together at panel joints using steel cover plates, rather than welding special rebar to angle iron that has to fit in the knockout pockets. The channel can also provide wall tie support in lieu of using hold downs. And bolting the channel to the concrete is better at vertical load and horizontal shear transfer to the concrete than wood is. Just a suggestion.
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
Joseph I love the idea - I'm new to tilts so this was the path given to me. I'll suggest something like this moving forward to consider! thank you!
@Ins.Yuk.Muh.MertUstun
@Ins.Yuk.Muh.MertUstun 4 ай бұрын
Hello. Thank you for this video. I want to know how drag struts (collectors) members transfer forces to vertical members. Could you please explain it?
@palestinianyouth1962
@palestinianyouth1962 2 жыл бұрын
Great work my man, I love your channel. I have a job that have irregular diaphragm (we have to introduce transfer diaphragm,etc). There is a detailed example peper online by R. Terry Malone, I ouldn't follow the concept of the unit shears shown in the little squares, and the sign convention). It would be very helpful I think if you could study it and go over it and explain it. You do great job explaining things, I honestly think it woulf be a good and unique content that is massively needed, since not any videos about that is posted also many engineers don't know how to handle it, so hopefully will pay back with more views :)
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
Hell yeah Palestinian Youth! ill check out the paper!
@QuickQuestionEngineering
@QuickQuestionEngineering 2 жыл бұрын
Great content Rich! To transfer the load (the chord tensile force) from the roof deck to the tilt-up panels, would you then use a continuous angle with post installed anchors at a certain spacing? If the deck is wood, maybe a ledger? I’d imagine the anchor spacing would have to be really tight in the middle (highest moment) and larger towards the edges.
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
great detailing questions QQE! it depends on how your roof framing is oriented. the connections your questioning are more for out of plane anchorage of the walls to the diaphragm. the ledger connection is another great point, and is used when joists run parallel with the panels. and lastly, depending on your seismic design criteria, you have sub-diaphragm design you need to look at. always a bunch more to do for a real building, and you are asking all the right questions!
@user-vz5kb8qf8x
@user-vz5kb8qf8x 7 ай бұрын
Can you do one for collector forces including determining from ETABS section cut ??
@Kestava_Engineering
@Kestava_Engineering 7 ай бұрын
im not an ETABS guy. I want to learn it but im no good at the moment!
@robertmarmaduke9721
@robertmarmaduke9721 2 жыл бұрын
Figure out how to offer CEUs and you'd have 4.52M subscribers. I'm stunned nobody has figured this CEU on YT franchise yet. Good stuff on this Full Building Design series.
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
BRO - thats the idea i like to hear!
@krispe2512
@krispe2512 2 жыл бұрын
For wood framing, wouldn't the floor decking help with this deflection and reduce the tension experienced by the chord? Other than a double 2x4 top plate what else would reduce the tension load.
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
yes absolutely! there is tensial strength that you could rely on from the deck and double top plate in wood construction
@luisdelcid7051
@luisdelcid7051 2 ай бұрын
In a rectangular building with CM and CR in the geometricial center is it fair to assume and only analyze the diafragm in it's most demanding section (longer side) given that this will provide the critical chord forces?
@Kestava_Engineering
@Kestava_Engineering Ай бұрын
that is true - however even a perfectly symmetric structure still requires a 5% eccentricity added to the analysis per code
@aboudeh21
@aboudeh21 Жыл бұрын
I thought the seismic force should be considered as a concentrated load on the center of mass of the building
@Kestava_Engineering
@Kestava_Engineering 11 ай бұрын
thats if you are designing a rigid diaphragm!
@aboudeh21
@aboudeh21 11 ай бұрын
@@Kestava_Engineering so in rigid diaphragm we don't have to design chords and collectors ?
@Mauleflyer100rv
@Mauleflyer100rv Жыл бұрын
The chord is typically a continuous deck support angle. Not done as this video suggests.
@Kestava_Engineering
@Kestava_Engineering Жыл бұрын
I have seen the angle before! I have not done a ton of tilt projects and for those that I have seen its been done with chords in the actual tilt up panels. where do you see this mostly? Im always trying to expand my detailing knowledge!
Designing Engineered Wood Diaphragm Systems
56:07
APA – The Engineered Wood Association
Рет қаралды 1 М.
Flexible Diaphragm Chord Demand
10:12
Tonatiuh Rodriguez Nikl
Рет қаралды 4,2 М.
Prank vs Prank #shorts
00:28
Mr DegrEE
Рет қаралды 10 МЛН
Underwater Challenge 😱
00:37
Topper Guild
Рет қаралды 37 МЛН
Or is Harriet Quinn good? #cosplay#joker #Harriet Quinn
00:20
佐助与鸣人
Рет қаралды 7 МЛН
Diaphragm Design Forces
9:46
Tonatiuh Rodriguez Nikl
Рет қаралды 5 М.
PE Seismic Review: How to Calculate Chord and Collector Forces
19:31
Best Structural Wood Design Books
6:39
Mat Picardal
Рет қаралды 21 М.
How to Design a Weld For TORSIONAL Loads | Civil PE Exam Prep
12:53
How much load can a timber post actually carry?
8:57
The Engineering Hub
Рет қаралды 768 М.
A tale as old as time #engineering #architect #construction
0:12
Prank vs Prank #shorts
00:28
Mr DegrEE