How to connect Higher current Rating module with small capacity of inverter ?

  Рет қаралды 4,332

Solar Facts

Solar Facts

2 жыл бұрын

How to connect Higher current Rating
module with small capacity of inverter ? || अब हाई करंट के पैनल भी लगेंगे छोटे इनवर्टर पर |
#havells #canadiansolar
#Module compatibility #highercurrentmodule
Solarinverter #solarpanel #stringdesign #stringdeignofhighercurrentmodule
Solar
Safest
Smarter
Saur urja
Biljli Kaise bachaye
Solar se Bijli Kaise Bachaye
Benefits of Installing solar
Profitable solar
Solar k Fayede
Solar Lagane k Fayade
MCB
MCCB
ACB
AJB
ACDB
DCDB
Lighting Arrester
walkway
cable Tray
Solar Panel
Solar Inverter
Solar Cable
AC Cable
Follow me on -
Telegram- t.me/+uVOzUWjDk0tiNTBl
LinkedIn- / raman-kumar-666436141
Facebook - / solarfacts-37057195372...
solar structures
Solar panel mounting structure
Solar mounting structure
acdb and dcdb for solar system
acdb box price
dcdb box for solar system
dcdb box price
long rail solar structure
mini rail for solar panels
mini rail solar structure
solar mounting structures
solar panel structure
solar structure
solar structure types
types of mounting structures for solar panels
types of solar mounting structure
types of solar structure
mounting structure for solar panels
mono rail solar structure
solar acdb box
solar acdb dcdb box
solar dcdb box
solar mini rail
standing seam solar structure
tilted solar structure
acdb box for solar
dcdb box for solar
Video link -
1. How solar zero export works.- lnkd.in/evPgfuj2
2. What is Enphase microinverter ? // Microinverter & it’s step wise installation explanation. - lnkd.in/e3mr7HjF
3. Concept of Solar Inverter Overloading //Solar inveter overloading is right or wrong !!!! - lnkd.in/eDNXTc2z
4. What is Reactive Power ? // Why Industries Power Factory become poor after installing Solar! - lnkd.in/ei8S_d_m
5. What is CT? What is CT Ratio? How to select CT? - lnkd.in/eCkNRTtZ
6. How to check Current Transformers? - lnkd.in/eT5gc99e
7. Why Solar Systems are not Success with Zero Export device. // Precautionary Majors for Zero Export. - • Why Solar Systems are ...
8. How to design SolarEdge string // How to use SolarEdge string designing tool. - • How to design SolarEdg...
9. How to install solar panel // What is the right way to install solar panel. - • How to install solar p...
10. How to calculate string design for solar Inverter? -- lnkd.in/ekujjSpm
11. How to design stand alone solar system & Battery bank capacity - lnkd.in/exEYzYdD
12. What is surge protection device? // How to protect our system from surge? - • What is Surge Protecti...
13. What is Armoured cable? // what is the benefits of Armoured cable?- • What is Armoured cable...
14. Why Single Core Cable Comes with AL Armoured not with Steel? -- • Why Single Core Cable ...
15. How To Calculate Neutral Current? 3 Phase Neutral Current Calculation! Unbalance current calculation! - • How To Calculate Neutr...
16. What is Neutral Floating? // Why voltage increase // what happen if neutral breaks in a transformer. - • Video
17. Solar Power Plant Shadow Analysis ! // Shadow Calculations for Row Spacing.
• Solar Power Plant Shad...
18. What is 1000VDC and 1500VDC solar system.// Advantage and Disadvantage of 1500VDC Solar System - • What is 1000VDC and 15...
19. What is Netmetering and What is Gross metering. // Netmetering and Gross metering billing method. -- • What is Netmetering an...
20. What is PID (Potential Induced Degradation) ? Why PID Occurs in Solar Panel ? / How to check PID ? -- • What is PID (Potential...
21. How to select solar panel on technical basis ? // Best solar panel selection as per project. -- • How to select solar pa...
22. What Is Solar PERC Technology? // Mono PERC // Poly PERC. // Passivated Emitter and Rear Contact -- • What Is Solar PERC Tec...
23. How to Calculate size of Earting Conductor and Earthing Electrodes? // Earthing Calculation. -- • How to Calculate size ...
24. How Mismatch affect Solar Plant Generation?What are the causes of Mismatch losses ? -- • How Mismatch affect So...
25. Why Solar Energy Consume First ? // How Import and Export Works in Solar system ? -- • Why Solar Energy Consu...
26. What is P-Type and N-Type Semiconductor? // How Solar Cell Works? -- lnkd.in/e6Ydxc2P
27. Design your Solar Plant On your Own /Battery Selection and Sizing Calculation /Battery Calculation. -- • Design your Solar Plan...
28. How Lithium-Ion Batteries Are Cheaper Than Lead Acid? // C Rating of Battery // C-10, C-20 and C-5. -- • How Lithium-Ion Batter...
29. Comparison between string inverters vs micro inverter // Benefits of micro inverter. -- • Comparison between str...
L
For more information contact us 😊.
Name - Raman Kumar
Contact No- 9871073342

Пікірлер: 49
@sathyaprasad1411
@sathyaprasad1411 4 ай бұрын
,,👌👌👌👏👏👏👍👍👍👍
@Amazingsolar7753
@Amazingsolar7753 2 жыл бұрын
Very informative video
@solarfacts4242
@solarfacts4242 2 жыл бұрын
Thanks 🙏
@ramdhaniyadav2338
@ramdhaniyadav2338 2 жыл бұрын
Very well explained!! Thank you🙏🙏
@solarfacts4242
@solarfacts4242 2 жыл бұрын
Thank you sir
@sourabhsharma9985
@sourabhsharma9985 2 жыл бұрын
Love to see that how basic KCL can solve the bigger problem,very nice vedio sir.
@solarfacts4242
@solarfacts4242 2 жыл бұрын
Thanks Sourabh
@amardeepsingh1984
@amardeepsingh1984 2 жыл бұрын
well explained
@solarfacts4242
@solarfacts4242 2 жыл бұрын
Thanks 🙏
@neutral6778
@neutral6778 2 жыл бұрын
Very informative sir
@solarfacts4242
@solarfacts4242 2 жыл бұрын
Thanks
@technopower1298
@technopower1298 2 жыл бұрын
Good work sir , i too was designing 5kw with cs and finding the same issue, but now its all clear all thanks to you.
@solarfacts4242
@solarfacts4242 2 жыл бұрын
Thanks 🙏
@siddharthsrinet9022
@siddharthsrinet9022 2 жыл бұрын
👍👍👍👍
@solarfacts4242
@solarfacts4242 2 жыл бұрын
Thanks
@pgmakwana
@pgmakwana 11 ай бұрын
Sir jo baord pe write karke rakhte ho vo value Barbara dikhti nahi he so write big so we under stand better
@solarfacts4242
@solarfacts4242 11 ай бұрын
Please rotate your phone I am sure it will be visible
@harikrishnankr9150
@harikrishnankr9150 2 жыл бұрын
😍😍
@solarfacts4242
@solarfacts4242 2 жыл бұрын
Thanks 🙏
@user-bj6eo2ke9x
@user-bj6eo2ke9x 10 ай бұрын
Hello sir. Good Explanation. But if MC4 burn or damage of any positive or negative end will cause a dangerous situation for the inverter at peak load. Isn't it? Please explain
@solarfacts4242
@solarfacts4242 9 ай бұрын
Actually in this case both the MPPT Are working parallel it’s not working individually
@siddharthsrinet9022
@siddharthsrinet9022 2 жыл бұрын
Bhai kabhi transformer less aur transformer wale inverter me diffrence wala vedio banao
@solarfacts4242
@solarfacts4242 2 жыл бұрын
Sure
@gnaneshwarsamal7176
@gnaneshwarsamal7176 2 жыл бұрын
if you are using 2 MMPT means than you can select parallel operation mode
@solarfacts4242
@solarfacts4242 Жыл бұрын
Yes
@pramodshah1830
@pramodshah1830 7 ай бұрын
Mere question hai ki. Mppt agar ak hai inverter me 100kw le delta me. Or usme 8 string de rahe hai smb me each having 16 amp. How will mppt work than. Multiple string but only 1 mppt in imverter?
@saifsyedmohammad3769
@saifsyedmohammad3769 Жыл бұрын
I have 15 panels of 335 W panels in series with a total voltage of 520V. My inverter supports 1000V Voc. I have a 550 W panel with a slightly higher current rating lying around. Can I connect this single panel in series will all other 15 panels ?
@solarfacts4242
@solarfacts4242 Жыл бұрын
You can but due to miss match your 550 watt panel will also work as a 335 watt panel
@saifsyedmohammad3769
@saifsyedmohammad3769 Жыл бұрын
Help Please !I have 15 panels of 335 W panels in series with a total voltage of 520V. My inverter supports 1000V Voc. I have a 550 W panel with a slightly higher current rating lying around. Can I connect this single panel in series will all other 15 panels ?
@solarfacts4242
@solarfacts4242 Жыл бұрын
You can but due to miss match your 550 watt panel will also work as a 335 watt panel
@mohanmachinerymart4551
@mohanmachinerymart4551 2 жыл бұрын
hello sir yeh parallel mode har invertor mai hota hai
@solarfacts4242
@solarfacts4242 2 жыл бұрын
No but this is in Havells
@utkarsh329
@utkarsh329 11 ай бұрын
but in Y-connector case only one string making then this will not make use of 2 MPPT (if shadow on 1 panel then whole system down)
@solarfacts4242
@solarfacts4242 11 ай бұрын
Yes this will be problem
@MR_SOLAR_BABA
@MR_SOLAR_BABA 2 жыл бұрын
It is dangerous practice, suppose one mppt stops working connector may burn or damaged to the inverter.
@solarfacts4242
@solarfacts4242 9 ай бұрын
Sir actually both tha MPPT is working in parallel mode if there is any problem with one MPPT both will not work
@solarfacts4242
@solarfacts4242 9 ай бұрын
So there is no problem
@poorvadityainfrasolutions5186
@poorvadityainfrasolutions5186 Жыл бұрын
How to connect if inverter have only single mppt
@solarfacts4242
@solarfacts4242 Жыл бұрын
then not possible
@ptkgupta
@ptkgupta 2 жыл бұрын
Problem: 540Wp/IMP: 12.9A Using Y connectors, we We are unable to overload the inverter as only 1 string can be connected per MPPT. Any suggestions. Can you suggest some good inverters with 30A+ MPPTs in 50 to 100KW range.
@solarfacts4242
@solarfacts4242 Жыл бұрын
for 50 and 100 Kw you can get high rating of MPPT
@karkar5360
@karkar5360 10 ай бұрын
The 17 amp will not divide into as you said.8.5 +8.5 by Y connectors You are wrong make it correct .
@solarfacts4242
@solarfacts4242 9 ай бұрын
Sorry but in this case both the mppt will work in parallel mode and equal amount of current will flow
@CoolDude-vc2fl
@CoolDude-vc2fl 16 күн бұрын
MPPT can not share a string.
@solarfacts4242
@solarfacts4242 16 күн бұрын
It can and I have done at multiple sites
@yasirkazi9703
@yasirkazi9703 2 жыл бұрын
Can you please confirm that the current through the y connector gets divided equally? Also, does the inverter manufacturer allow us to use this? Technically it looks feasible. But the manufacturer should also approve it so that it helps in case of claiming warranty.
@solarfacts4242
@solarfacts4242 2 жыл бұрын
Yes this is approved by Havells
@sachinwadje3948
@sachinwadje3948 2 жыл бұрын
Not agreed with last point explain by you at evening or in morning voltage not get affected only current generation is lower So in case of renewsys 400wp module we can used two separate string Benefit of using two separate string is in case of failure of other string at least half generation is continue other thing nicely explain by you
@solarfacts4242
@solarfacts4242 2 жыл бұрын
ok
Looks realistic #tiktok
00:22
Анастасия Тарасова
Рет қаралды 105 МЛН
What it feels like cleaning up after a toddler.
00:40
Daniel LaBelle
Рет қаралды 70 МЛН
What is the difference between Neutral, Grounding and Earthing ?
15:02
Net metering  Import vs Export  the Problem & connection Problem
21:38
Sustainable Every Day
Рет қаралды 132 М.
How a Variable Air Volume VAV System Works
16:54
MEP Academy
Рет қаралды 102 М.
How Bugatti's New Electric Motor Bends Physics
9:25
Ziroth
Рет қаралды 76 М.
2. What Makes Redis Special? | Redis Internals
22:04
Arpit Bhayani
Рет қаралды 35 М.
Looks realistic #tiktok
00:22
Анастасия Тарасова
Рет қаралды 105 МЛН