How to control VFD with push button switch/ terminal control/wire control

  Рет қаралды 131,076

ATO Automation

5 жыл бұрын

Buy ATO VFD online: www.ato.com/single-phase-to-three-phase-vfd
This video shows single phase to three phase VFD to make the motor forward and reverse in terminal control mode(push button switch control/3 wire control).This method can start and stop the motor without approaching the VFD.
Parameter settings in the video: P0.3=1, P4.02=9, P4.08=2
Other basic settings video,kzfaq.info/get/bejne/qZykh7SVprzQmYE.html
AC Contactor link,www.ato.com/ac-contactors
Relay link,www.ato.com/electromagnetic-relays
Switching power supply link,www.ato.com/switching-power-supplies

Пікірлер: 54
@dilipdande134
@dilipdande134 3 жыл бұрын
Good job.. Thanks allot..legends
@nagarasud1441
@nagarasud1441 2 жыл бұрын
Thank you 👍
@mahmoodalam4122
@mahmoodalam4122 5 жыл бұрын
Very nice video
@glennedward2201
@glennedward2201 4 жыл бұрын
I’m thinking about using a relay turned on by my 120v side of circuit. Switch on triggers relay for 240v. Would be nice not to have several switches.
@madhurao4538
@madhurao4538 3 жыл бұрын
Thank you sir
@bookquotes5
@bookquotes5 4 жыл бұрын
Thanks brother !!! Respect from Karachi , Pakistan.. Can you guide us briefly about VFD basics
@marloulariego9674
@marloulariego9674 2 жыл бұрын
Is this also applicable for a 1.5 HP Single phase motor? Can i ask for the specifications for the items use in this video?
@MichealJana
@MichealJana 8 ай бұрын
nice work
@fredastaire6156
@fredastaire6156 Жыл бұрын
Great video! Is there a such thing as using a wireless remote control for this set up?
@markzalavari1780
@markzalavari1780 4 жыл бұрын
Hi! How to wirelessly remote controll frequency?
@fojlerabbikhan2060
@fojlerabbikhan2060 5 жыл бұрын
Nice
@jaykesapalaran7001
@jaykesapalaran7001 Жыл бұрын
good tutorial, PLEASE CREAT A VIDEO HOW TO PROGRAM COMMAND IN SOFT STARTER AND VFD,🇵🇭🇵🇭🇵🇭❤
@drakon1300
@drakon1300 Жыл бұрын
I just bought a model EM15-sp1s1-1d5 /1ph 120v ac input -1.5kw 1ph/3ph 0~220v ac 7a output vfd for my wood lathe. this video shows a vfd with different terminals then the one I got and not sure which terminals to use for forward - reverse .. none of the terminals are labeled for. rev. or X ...
@runbou3485
@runbou3485 Жыл бұрын
អរគុណបង🙏
@ele4853
@ele4853 4 жыл бұрын
is your "switch" (green button switch) momentarily on or it "toggles" between on and off at each press?
@ATOcom
@ATOcom 4 жыл бұрын
In the video, the green button at 2:07 is a self-locking button (it is always ON after being pressed), and the green button on the rear control box is an auto-reset button (ON when pressed, and OFF when not pressed).
@ele4853
@ele4853 4 жыл бұрын
@@ATOcom OK so the one on the 2:07min. is a ON/OFF normally open and the "Green and White" on the yellow box are Momentarily Normally Open. What is the rate of amperage and voltage for the switches on the yellow box? Thanks in advance.
@vfgrfbgrb
@vfgrfbgrb 3 жыл бұрын
@@ATOcom don't understand schmetic so t1 t3 from contacter connected to vfd
@ioannisgalanos7911
@ioannisgalanos7911 3 жыл бұрын
Hello, can i start any frequency inverter with single phase? My motor is three phase. My inverter is a RM5G. I supose must change some settings.
@ATOcom
@ATOcom 3 жыл бұрын
I did not know the model you are using; but this has a dedicated VFD, such as ATO 1-phase input to 3-phase output VFD, www.ato.com/single-phase-to-three-phase-vfd
@darbats
@darbats 4 жыл бұрын
I have an air compressor 10hp. Can the VFD run the motor without the Red, White, Green buttons?
@ATOcom
@ATOcom 4 жыл бұрын
Yes, you can choose the control method: panel control, terminal control, modbus-RTU control, analog control.
@aymansaad7429
@aymansaad7429 2 жыл бұрын
Good work I have a drive like this It doesn't work A message on screen p. Off No apply for programming how can I do
@tettehphilipkwei3905
@tettehphilipkwei3905 6 ай бұрын
Please you need to show us step by step where all wires a connected practically cause people may not be familiar with some circuit diagram
@DemiFlower1010
@DemiFlower1010 3 жыл бұрын
Hi i just purchased a GK3000 single phase in and out for my 3hp lathe motor. Do you have a similar scamatic for me to use so I can make a enclosure to use. The only difference I need is I want to put a variable knob on the lathe and I want to use a joystick up for forward and down for reverse. Please if you can send me a scamatic.
@ATOcom
@ATOcom 3 жыл бұрын
Is this video what you want? kzfaq.info/get/bejne/irCjgZSYvJ7MhoU.html
@DemiFlower1010
@DemiFlower1010 3 жыл бұрын
@@ATOcom yes this helps but I have other questions not answered yet, this video is still for 3phase correct? I have single phase in and out. Am I gonna need the dc converter? And what about a scamatic for a joystick for forward and reverse control?
@ATOcom
@ATOcom 3 жыл бұрын
@@DemiFlower1010 1. Yes, the video is applicable to all GK3000-2S series (including single-phase output, three-phase output VFD), but it should be reminded that single-phase motors are not suitable for long-term operation below 80% of the rated speed because single The centrifugal switch of the phase motor will not be cut off at low speed, leading to the risk of burning the motor. 2. At present, the forward and reverse rotation of the motor can only be controlled by button, panel, and modbus communication. You can use the VFD in combination with the two videos you see. 3. What is your purpose of using DC converter? 4. If you encounter more troubles, please contact our after-sales team, www.ato.com/contactus
@DemiFlower1010
@DemiFlower1010 3 жыл бұрын
@@ATOcom I'm not interested in the dc converter I just keep seeing it in most the videos. I purchased this for my lathe as I said it's 3hp motor. So if I set this up like I see in those couple videos how long are you saying my motor Will last? And why would single phase input and output vfd control be made if its no good for your motor? Should I return it and purchase a single phase in and 3phase out and get a 3phase motor instead? I idid not know these were not good for single phase motors or I would not of purchased. Because On a lathe I'll probably be using the lathe speed less than 80 percent speed all the time so my motor will not last long your saying correct?
@ATOcom
@ATOcom 3 жыл бұрын
@@DemiFlower1010 1. The low-speed operation time of each brand of single-phase motor is different, which depends on its heat dissipation performance and the separation speed of the centrifugal switch. 2. Single-phase input & output VFD is suitable for single-phase motors that do not run at low speed for a long time, to adjust speed or reduce the impact of the motor on the power grid. 3. If your motor has a long-term use speed lower than 80% of the rated speed without matching the reducer, I suggest that you purchase a three-phase motor and use it with a single-phase input to three-phase output VFD (when running at low speeds, Note that the motor can dissipate heat in time)
@joaotuga7181
@joaotuga7181 4 ай бұрын
Please what are the specifications of the contactor and relay?
@ATOcom
@ATOcom 4 ай бұрын
Thank you for your inquiry sir. The specs of the contactor: 32A, 4 Pole, NO. For the relay, check out here: www.ato.com/electromagnetic-relay-dpdt-12-24-110-220v-coils
@user-wk9fy4si8y
@user-wk9fy4si8y 4 ай бұрын
can you give me full circuit diagram pls
@pv.inteless
@pv.inteless 5 жыл бұрын
Can i have your schematic diagram !
@alikhalaf805
@alikhalaf805 4 жыл бұрын
Why not use rela 220v ac allowance rela 24 v dc I am waiting for your answer, please
@ATOcom
@ATOcom 4 жыл бұрын
24VDC is a safe voltage and 220VAC is a dangerous voltage. In the application of automation equipment, the safe voltage is usually used to control the dangerous voltage.
@alikhalaf805
@alikhalaf805 4 жыл бұрын
@@ATOcom Thanks a lot for clarification. I am very grateful
@ATOcom
@ATOcom 4 жыл бұрын
@@alikhalaf805 : )
@rolandiansillano3068
@rolandiansillano3068 2 жыл бұрын
Hi sir can you give me idea how to run motor with vfd 10 hz to 50hz repeatedly
@ATOcom
@ATOcom 2 жыл бұрын
You mean run at 10Hz for a while, then run at 50Hz for a while, and so on? 1. You can use VFD two-stage speed control mode + 2 time relays, and connect a group of multi-function terminals after each time. 2. You can use PLC to build control logic to activate a certain speed at regular intervals. VFD can choose multi-speed control or directly control VFD frequency by Modbus communication. ATO VFD multi-speed control mode link, kzfaq.info/get/bejne/q8B7prOYyKiWkWw.html
@shreelaser4685
@shreelaser4685 Жыл бұрын
how can we control vfd using only limit switch
@judemanoharan1863
@judemanoharan1863 3 жыл бұрын
Please send the credit wiring details
@camron2674
@camron2674 5 жыл бұрын
I know the objective of the video was to get remote push buttons to control VFD. So I assumed you entered the other parameters like voltage and hertz before this video was recorded...?
@ATOcom
@ATOcom 5 жыл бұрын
YES.
@PTinvest
@PTinvest 2 жыл бұрын
What role of the relay
@ATOcom
@ATOcom 2 жыл бұрын
Low voltage control high voltage
@sambamurthy883
@sambamurthy883 2 жыл бұрын
Saft stater control wireing diagram plz make video sir
@ATOcom
@ATOcom 2 жыл бұрын
This video, kzfaq.info/get/bejne/fdGDopR1tKisnIE.html
@jackb3232
@jackb3232 4 жыл бұрын
That's smps is little overpowered,😉
@ATOcom
@ATOcom 4 жыл бұрын
:)
@Devanfarm
@Devanfarm 3 жыл бұрын
motor connection must be STAR or DELTA
@ATOcom
@ATOcom 3 жыл бұрын
all ok
КАРМАНЧИК 2 СЕЗОН 7 СЕРИЯ ФИНАЛ
21:37
Inter Production
Рет қаралды 528 М.
БОЛЬШОЙ ПЕТУШОК #shorts
00:21
Паша Осадчий
Рет қаралды 9 МЛН
Who has won ?? 😀 #shortvideo #lizzyisaeva
00:24
Lizzy Isaeva
Рет қаралды 27 МЛН
ROCK PAPER SCISSOR! (55 MLN SUBS!) feat @PANDAGIRLOFFICIAL #shorts
00:31
OZON РАЗБИЛИ 3 КОМПЬЮТЕРА
0:57
Кинг Комп Shorts
Рет қаралды 1,4 МЛН
Спутниковый телефон #обзор #товары
0:35
Product show
Рет қаралды 2,2 МЛН
Simple maintenance. #leddisplay #ledscreen #ledwall #ledmodule #ledinstallation
0:19
LED Screen Factory-EagerLED
Рет қаралды 27 МЛН
Easy Art with AR Drawing App - Step by step for Beginners
0:27
Melli Art School
Рет қаралды 8 МЛН
Mastering Picture Editing: Zoom Tools Tutorial
0:52
Photoo Edit
Рет қаралды 503 М.