Class 26 | How to design sprinkler system? NFPA 13

  Рет қаралды 3,545

Irfan CFPS

Irfan CFPS

Күн бұрын

"In this comprehensive video, I am going to explain how to design a wet sprinkler system for an Hospital building.
By the end of this tutorial, you will feel confident in your ability to design sprinkler systems for any commercial building.
I'll provide detailed steps based on my experience, ensuring you won't regret investing your time in watching this.
After completing this video, you'll likely have learned everything you need to know about sprinkler system design."
Wet pipe sprinkler system : • Class 3 | Wet pipe spr...
Pipe schedule method : • Class 15 | Pipe schedu...
Area / Density curves : • Class 16 | Hydraulic C...
Sprinkler system components : • Class 11 | Sprinkler S...
Hydraulic calculations : • Step 1 | Hydraulic Cal...
: • Step 2 |Hydraulic Calc...
: • Step 3 |Hydraulic Calc...
: • Step 4 |Hydraulic Calc...
: • Step 5 |Hydraulic Calc...
: • Step 6 |Hydraulic Calc...
: • Step 7 |Hydraulic Calc...
: • Step 8 |Hydraulic Calc...
: • Step 9 |Hydraulic Calc...
: • Step 10 |Hydraulic Cal...
: • Step 11 |Hydraulic Cal...
Your queries:-
irfancfps
irfan cfps
nfpa 13
nfpa13
sprinkler design
design sprinkler
nfpa 13 sprinkler system design
nfpa standards
nfpa 13 training videos
how to design sprinkler system
how to design a sprinkler system
sprinkler system design
design sprinklers
sprinkler designing
designing sprinkler system
fire sprinkler design
designing sprinklers
procedure to design sprinkler system
designing sprinkler system as per nfpa
sprinkler design as per nfpa 13
nfpa13 design
#fireprotection #fire #firefighting #firefighter #nfpa

Пікірлер: 30
@Quirov
@Quirov 4 ай бұрын
Thank you Sir for sharing ur expertise!!..ur passion as a professor keeps our hopes high..😂..
@irfancfps
@irfancfps 4 ай бұрын
Please do share with others so that they could also benefit from this
@Atoz-xh4xc
@Atoz-xh4xc 4 ай бұрын
Very help full information whenever i watch your videos i learn something new from your videos so please keep making videos thanks alot ❤
@irfancfps
@irfancfps 4 ай бұрын
Most welcome. Please do share with others so that they could benefit from this
@zeek4967
@zeek4967 2 ай бұрын
Very helpful lecture. Thank you for uploading.... ❤
@irfancfps
@irfancfps 2 ай бұрын
Most welcome. Please do share with others
@gokulnaathmallinathan6993
@gokulnaathmallinathan6993 3 ай бұрын
Thank you for posting videos in English. You have done a great job 👍 All the best!
@irfancfps
@irfancfps 3 ай бұрын
Thanks. Please do share with others so that they can also benefit from these videos.
@theholyquran755
@theholyquran755 4 ай бұрын
Thank you brother Irfan . Very helpful as usual , It would be great if you can take a real example step by step or make a real time video so we can discuss with you the design issues. Interactive live video if possible with a small project supported with autocad work.
@irfancfps
@irfancfps 4 ай бұрын
If u carefully see the video u will be able to prepare the sprinkler system design. I don’t think there is any need of other video since it covers everything including real time example building. Autocad work cannot be explained since it will take months to complete
@mdtutulhasan9079
@mdtutulhasan9079 4 ай бұрын
You are doing well. Keep it up brother
@irfancfps
@irfancfps 4 ай бұрын
Thank you so much. Please do share with others as well so that they can benefit from my videos
@nadeemmushan7545
@nadeemmushan7545 3 ай бұрын
Sir where should i start to learn about hazrad classification and ..do u have video from day 1 of your teaching ..pls let me know
@irfancfps
@irfancfps 3 ай бұрын
U can search on my youtube channel "irfancfps". Playlists available in sequence class by class..and also if you want to learn about hazard classification, Please check this video : kzfaq.info/get/bejne/ibaGZK1quqyyn58.htmlfeature=shared
@WALKPROJECTS-jd3kw
@WALKPROJECTS-jd3kw 2 ай бұрын
How do we size the sprinklers pipes for an extra hazard occupancy using hydraulic method. Since we cannot use the pipe schedule method.
@irfancfps
@irfancfps 2 ай бұрын
Nice question. Pipe sizing Has to be concluded based on hydraulic calculations… but initially we put the sizes based on pipe schedule (OH) and then will be verified using hydraulic calculations. Is it clear? Or any doubt let me know
@WALKPROJECTS-jd3kw
@WALKPROJECTS-jd3kw 2 ай бұрын
@irfancfps thank you so much irfan, i have been racking my head for this,. This is very helpful. Can i use extra hazard occupancy or class IV storage occupancy for an alcoholic beverage/drinks storage warehouse of over 5120sqm
@tarekfathy6827
@tarekfathy6827 2 ай бұрын
Great job Irfan
@irfancfps
@irfancfps 2 ай бұрын
Thank you. Please do share with others
@tarekfathy6827
@tarekfathy6827 2 ай бұрын
What is the max number of sprinklers per header or riser
@irfancfps
@irfancfps 2 ай бұрын
I believe there is no limit.
@turkfire
@turkfire 3 ай бұрын
Thanks a lot
@irfancfps
@irfancfps 3 ай бұрын
Most welcome. Please share with others as well so that they can benefit as well.
@ibrahimn.j.4943
@ibrahimn.j.4943 Ай бұрын
Thanks, Eng. Irfan. Do we have to have a check alarm valve at every ZCV? Also, for the hydraulic calculations do we only need to do it for the most remote area? I mean the code requires we put a plate at every ZCV, assuming I have several floors/zones, the plate for hydraulic calculation will it be showing same calculation for that most remote area, or gonna demonstrate the hydraulics design calculation for remote area of that floor/zone only?
@irfancfps
@irfancfps Ай бұрын
No need check valve but…. If provided no issue..
@irfancfps
@irfancfps Ай бұрын
Hydraulic calculations will be done considering hydraulically most demanding area and most remotest area only…
@ibrahimn.j.4943
@ibrahimn.j.4943 Ай бұрын
@@irfancfps so I will have the hydraulic design plate on all ZCV showing same information (of that most remote area in the building)
@ibrahimn.j.4943
@ibrahimn.j.4943 10 күн бұрын
@@irfancfps So when alarm check valve are required? In a building of multiple floors, is there a minimum?
@Atoz-xh4xc
@Atoz-xh4xc 4 ай бұрын
If possible please make some videos in hindi or urdu language thank alot ❤
@irfancfps
@irfancfps 4 ай бұрын
Sure
Class 3 | Elite fire Sprinkler system calculations
29:55
Irfan CFPS
Рет қаралды 1,9 М.
If Barbie came to life! 💝
00:37
Meow-some! Reacts
Рет қаралды 76 МЛН
managed to catch #tiktok
00:16
Анастасия Тарасова
Рет қаралды 46 МЛН
Мы сделали гигантские сухарики!  #большаяеда
00:44
Fire Sprinkler system | Firefighting lesson 6
13:56
AMJ Engineering
Рет қаралды 296 М.
Hydraulic Calculations For Fire Sprinkler Systems
35:24
H. Machacon Mechanical Engineering
Рет қаралды 35 М.
15 - Fire pipe, sprinklers system design, using pipe schedule method of NFPA 13.
44:03
NC Engineering & Technology
Рет қаралды 17 М.
Class 2 | NFPA 72 | Fire Alarm System Basics
20:28
Irfan CFPS
Рет қаралды 1,8 М.
If Barbie came to life! 💝
00:37
Meow-some! Reacts
Рет қаралды 76 МЛН