Installing a light fixture with a ground inside the electrical box will require a battery powered drill and a few other tools. Install a light fixture with a ground inside the electrical box with help from a foreman for Lighty Contractors in this free video clip.
Expert: Joshua Clement
Filmmaker: Nathanael Rittichier
Series Description: You always want to be as careful as possible when performing electrical repairs in your home. Find out about electrical repairs you can do on your own with help from a foreman for Lighty Contractors in this free video series.

Пікірлер: 112
@alexandermack1472
@alexandermack1472 2 жыл бұрын
Thanks for answering the question simply and clearly! God bless you.
@timmarrier
@timmarrier 2 жыл бұрын
Remember, something's only actually "grounded' when it's connected to a circuit equipment ground, meaning ultimately the home run wire/cable back to the panel where the circuit breaker is. If there's effectively no ground wire (or path) back to the panel, it's considered an ungrounded (2-wire) circuit and a GFCI must be used ahead of any device or fixture that requires or contains a factory-installed ground or ground connection. (nec 410.44, ex 2)
@JW-wu9vp
@JW-wu9vp 3 жыл бұрын
This is a nice and clear video. Thank you. I have a 70s house. I found a recessed fixture...no groundwire. The 2 wires I see are the same color.
@TheRottiemama2003
@TheRottiemama2003 4 жыл бұрын
Thanks you so much you answered the troubling question!!!!!
@nathanwinters1247
@nathanwinters1247 3 жыл бұрын
The real answer, if you come across a box with 2 wires, is to first test the box for ground, see if it's grounded, if not then you have to run a ground wire all the way to the house main ground. If the house isn't grounded at all, you have to establish a ground. Both can be huge jobs.
@fabulouspinkmk10
@fabulouspinkmk10 Жыл бұрын
Young man you did a fantastic job of communicating the steps in a simple and understanding way. Now every person
@fabulouspinkmk10
@fabulouspinkmk10 Жыл бұрын
can benefit from your post.👍👍
@troyd7464
@troyd7464 5 жыл бұрын
wood is not a conductor so how is the light grounded? confused
@robertgraham5619
@robertgraham5619 4 ай бұрын
Well done! Quick and to the point. Thank you.
@williamstar7225
@williamstar7225 4 жыл бұрын
How to install a fire hazard in your house: DIY Insurance Nightmare
@benitogonzalez8712
@benitogonzalez8712 2 жыл бұрын
Excellent teacher. Thank you
@trishgraham9697
@trishgraham9697 7 жыл бұрын
Thank you very much! We have an older house, and while a lot of it was fixed up or remodeled before we bought it the plumbing and electrical weren't. I was going crazy!! Thank you again!
@safinahmed775
@safinahmed775 3 жыл бұрын
Thanks so much for your great lesson.
@guillaumekircher18
@guillaumekircher18 2 жыл бұрын
Easy to use and effective
@justthequadtip2.08
@justthequadtip2.08 6 жыл бұрын
Thanks for the info!
@LilMtn0011
@LilMtn0011 2 жыл бұрын
Very clear. Just what I needed for my 1953 house. So, it doesn't matter if all the wires are touching and crossed at the end?
@Chentedann
@Chentedann 3 жыл бұрын
Thank you!!
@BrewerShettles
@BrewerShettles 3 жыл бұрын
At start of video, need to mention importance of making circuit COLD up front. Test that there is no power in wires.
@simplemindish
@simplemindish 4 жыл бұрын
Thanks man
@jamesgeorge5310
@jamesgeorge5310 10 жыл бұрын
This is sloppy. Wire wrapped around a screw (like the ground wire he attaches here) should be wrapped CLOCKWISE, so that the screw tightens it as it tightens.
@Eastbaypisces
@Eastbaypisces 5 жыл бұрын
Can you get that brace separate from the light or do you have to buy both together?
@mail06513
@mail06513 6 жыл бұрын
Interesting how everyone is criticizing this video, but does not say what the proper way of doing it. So what is the proper way of grounding the light fixture in this situation?
@goatofdeath
@goatofdeath 4 жыл бұрын
One way to do it is you would pigtail the ground screw to either a wirecap or push-in connector and then combine both the incoming ground and the light ground with that pig tail in the wirecap or push-in connector. That would bond all three grounds together.
@allthethings7226
@allthethings7226 4 жыл бұрын
@@goatofdeath there was no incoming ground that is the problem
@goatofdeath
@goatofdeath 4 жыл бұрын
The wire coming in to it is a 12/2 which carries ground. I can see the ground off the incoming wire in the video. Now if it’s not hooked up to anything on the other side that’s a separate grounding/bonding problem.
@MARIAREY5
@MARIAREY5 3 жыл бұрын
Hey man I’m installing a ring camera but I don’t have a ground cable coming out from my wall either so should I do the same as the video ?
@williamkell9856
@williamkell9856 6 жыл бұрын
The proper way to ground all the metal in this box is to connect the bare equipment grounding conductor to the metal light bracket. One method this can be done using a 6" long piece of stranded #14 with green insulation. Connect it to the EGC of the Romex cable with a wire nut. The use a crimp fork tongue (or ring tongue) crimp lug to connect the new grounding pigtail to the lighting brackets. I would also use a crimp lug on the EGC of the fixture. These should be secured under the green EGC screw. I would then replace the to metal mounting screws with non conductive type screws. Or they must also be grounded.
@williamkell9856
@williamkell9856 6 жыл бұрын
I'm also a licensed electrician. I watched this video closely and the bare equipment ground conductor from the incoming Romex cable in the top doesn't appear to be connected anywhere. He didn't even address the connection of that wire. This drives electricians crazy.
@alwaystruth4872
@alwaystruth4872 5 жыл бұрын
I have a question. Do I need the fixture plate for a ground? Or can I hook up my ground coming out of my house (3 wire) directly into my light fixture ground wires (2 grounds for dual motion sensor). And just skip right past the ground screw in fixture plate?
@thenextgen1able
@thenextgen1able 5 жыл бұрын
@@alwaystruth4872 You can safely do that
@poetnk
@poetnk 4 жыл бұрын
I think that was supposed to be for demonstration purposes in case you are working on an old house project that only runs 2 wires and no ground. It doesn't help that the rest of the video is also unsafe.
@CountryBlessingz
@CountryBlessingz 4 жыл бұрын
Greetings. Does this work with ceiling fan? The mobile home doesn't have a ground wire coming from ceiling although the ceiling fan came with a ground wire..???
@Nero0
@Nero0 3 жыл бұрын
I have the opposite problem with a Philips Hue Impress; there's a grounding wire coming from the box, but nothing obvious to connect it to in the light fixture 😂👈🏻
@HyperKicker
@HyperKicker 5 жыл бұрын
Thank you, your video helped me, I have no electrical experience. God bless you.
@kenmcf
@kenmcf 3 жыл бұрын
I have the same situation right now. There is no ground wire available in the circuit. The old light I pulled had a green screw to attache the ground wire to on the support bracket. My thinking is...if the box is metal...the ground wire will send the charge to the box..but no place else as the box is not connected somehow to the "earth ground" system or wire. Since My box is plastic...my understanding is...you cannot get electrocuted by touching it if the ground wire is attached to it....I suppose the purpose at least for me is to keep the ground wire out of the way....since its a ceiling light I don't think it will be too dangerous...but for sure....if part of the light is metal...and its hot...you could get a jolt there I am assuming...so for me I will always just turn off the circuit/light and test including the light body frame it if I ever need to change bulbs or something.
@danielsdesigns1
@danielsdesigns1 6 жыл бұрын
Can this be done in a bathroom
@lloydharr8597
@lloydharr8597 7 жыл бұрын
The ground wire out of the Romex needed to be connected to the light ground wire. A pigtail to the ground screw and tie them all together with a wire nut.
@shecook62
@shecook62 7 жыл бұрын
I just put up a vanity light exactly like this. Only there is no way to turn off the lights. It's hardwired. The old single light that was on a ceramic base, had a pull chain to turn it on and off. Is there a way to install an on/off toggle switch to the base, or switch out the light screw that has the on/off pull chain?
@mikelisacarb
@mikelisacarb 6 жыл бұрын
Just bought one of these to convert my pull chain light to a switched light.www.amazon.com/gp/product/B015E7DTW4/ref=ask_ql_qh_dp_hza
@Hhhhhgggihgdd
@Hhhhhgggihgdd 2 жыл бұрын
What if I do have a ground wire coming out of the box but don't have a ground wire coming out of my wood light fixture ?
@sjr7822
@sjr7822 8 жыл бұрын
so, you don't bring the two copper wires together, I was wonder how I was going to get two copper wires pigtailed, underneath that little short green screw- I still don't know
@wolfepack999
@wolfepack999 3 ай бұрын
Where is your circuit ground wire connected? It doesn't look like you connected the circuit ground wire to the box or fixture.
@imfoolish438
@imfoolish438 2 жыл бұрын
So whats the copper wire for?
@frankarango4071
@frankarango4071 4 жыл бұрын
Sloppy. The comments below have better tips and correct how-to. Thank you people who comment with the right way of doing things.
@alwaystruth4872
@alwaystruth4872 5 жыл бұрын
I have a question. Do I need the fixture plate for a ground? Or can I hook up my ground coming out of my house (3 wire) directly into my light fixture ground wires (2 grounds for dual motion sensor). And just skip right past the ground screw in fixture plate?
@poetnk
@poetnk 4 жыл бұрын
You should always ground the metal box as well as the fixture in the event it gets touched by a hot wire.
@BreeFirstTV
@BreeFirstTV 5 жыл бұрын
Awesome. Thanks
@jefflanoka
@jefflanoka 5 жыл бұрын
I put up led. Light fixture, there was a bare wire for ground, but no green screw on bracket, the box in the ceiling had black,white and one completely bare wire, am I supposed to hook up the bare wire from light to the bare wire in the box?
@rinati75
@rinati75 5 жыл бұрын
Operations Management Yes.
@kosmossee4596
@kosmossee4596 4 жыл бұрын
@@rinati75 what's happens if a plug and switch dont have ground. Just black and white wire no ground how do u groud it
@stoneyj1a1
@stoneyj1a1 5 жыл бұрын
How is that now grounded?
@noname2577
@noname2577 4 жыл бұрын
Agreeable Dragon It’s not. This video is giving out dangerous advice.
@Eastbaypisces
@Eastbaypisces 4 жыл бұрын
If there is no ground such as k&t wiring in box, how u ground it then?
@rinati75
@rinati75 4 жыл бұрын
Brad S www.hunker.com/13414348/how-to-ground-an-electrical-outlet-with-no-grounding-wire
@williamkell9856
@williamkell9856 6 жыл бұрын
The last 2 daisy chained (power loops in and out to two fixtures) metal fixtures I worked on the first fixture all the bare grounds were twisted together but there was no pigtail to ground the fixture from the bundle of distribution equipment grounds. It was ungrounded but the second fixture the person grounded the fixture properly. Two different houses the DIY electrician left the first fixture ungrounded. Why? Because he's not a license electrician. If a licenced electrician doesn't ground things properly he will eventually be sued. You can count on that.
@2wyce
@2wyce 9 жыл бұрын
What's the ground connected to? Nothing? That looks dangerous...
@ruthless12street
@ruthless12street 4 жыл бұрын
Brian B ground isn’t supposed to be hooked up to anything but metal
@williamkell9856
@williamkell9856 6 жыл бұрын
All metal that might become live by an electrical system must be grounded. If a fixture is metal it must be grounded. Once the neutral leaves the main panel it must not be grounded or it floats. If a light switch has a green ground screw and you connect the bare ground wire to it, then the metal light switch box is grounded through the the metal mounting screws. This is not just some opinion. It's a fact. Grounding through the 2 mounting screws has been lab tested by UL. I would say about 20% of metal boxes and fixtures are not grounded. I had one call where a lady said the metal switch boxes in her garage were shocking her grand children. Folks..this is serious stuff and very dangerous.
@adam10532
@adam10532 3 жыл бұрын
What do you do with the ground wire that's coming out of the house just Tuck it in and don't connect to anything?
@wildjc1
@wildjc1 2 жыл бұрын
I have the same question...
@janewilson444
@janewilson444 Жыл бұрын
This video was just to demonstrate what to do if you don't have a ground wire coming out of the house.
@haleylynne1768
@haleylynne1768 3 жыл бұрын
Our house was built in 63 and our entire home Is wired like this no grounds exactly like this. This is older home style wiring when grounds weren’t a thing. Now they want ground on everything for protection. Some of us can’t afford to rewire an entire home. As long as wiring isn’t freyed to touch the box you should be fine in theory. Same for fans as long as there is no fraying or wires touching the electrical box to pose a current you should in theory be fine. Get remotes for fans so you don’t have to touch the pull strings and I doubt anyone Should be touching their light fixtures anyways
@miked5106
@miked5106 8 ай бұрын
the mounting screws weren't even aligned. the light was cockeyed.
@BrewerShettles
@BrewerShettles 3 жыл бұрын
Very sloppy adding GND wire to screw - wrapping it counterclockwise, when running the drill, the wire becomes a mess. Wrap it clockwise in the direction of tightening the screw.
@williamkell9856
@williamkell9856 6 жыл бұрын
As a Licensed electrical Contractor and Professional Engineer, grounding in residential homes (especially older ones) is one of the the things that upsets me the most. I believe amateurs think because a light or receptacle works and he installed it....maybe he thinks it's done right? Just because a light or receptacle is working that they just installed doesn't mean it was done to meet all the NEC requirements and is safe. In my opinion, proper grounding is a common issue and is dangerous if not done correctly..
@kkh2149
@kkh2149 4 жыл бұрын
I have a new home and the electrical box on the ceiling for my chandelier has no ground wire just the live and neutral wires. The chandelier came with a mounting plate that had a ground wire attached to the ground screw but the light itself has no ground wire just the neutral and live wire. How do I ground this!?
@saddad6601
@saddad6601 3 жыл бұрын
I tried to do it like this guy and I died. So, now that I’m dead I realize I should NOT have followed these instructions. Thanks e-how and thank you soulless ginger.
@nicoleemerson2655
@nicoleemerson2655 2 жыл бұрын
what do I do if my lighting fiture is antique and does NOT have the ground wire (it only has white and black) - and I DO have the ground wire in the ceiling - do I just screw the ground wire from ceiling into the grounding screw in box?
@tonpear5909
@tonpear5909 4 жыл бұрын
Douchebeard states this demo shows "how to hook up a fixture when there's no ground in the electrical box". There is no correct way to do exactly as he states. The correct way is to bring a ground in, which costs money and time, but right is right. Then Douchebeard proceeds to work on a setup that HAS a perfectly good ground wire just dangling in the box. He concludes that somehow the fixture will be magically grounded by wrapping its ground wire (counterclockwise, like an idiot would do) around a screw. That screw is bonded to several metal parts (OK) but then that metal assembly is attached to...... fucking *wood* studs. In the instance of a short to hot in this type of installation the homeowner would be LUCKY if the loose ground lead was pressed hard enough against the inside of the box (and only if a *metal* box) to conduct enough current to trip the circuit breaker. They would be less lucky to touch the lamp if the ground was open and even less lucky if the ground was touching enough to conduct current (heat) but not enough to trip the breaker. As bad as wood is at conducting electricity, it's very good at burning.
@timmarrier
@timmarrier 2 жыл бұрын
Wrong, you are required to GFCI protect grounded (3-wire) light fixtures installed on ungrounded (2-wire) circuits. See NEC 410.44 exception #2.
@ricardoh3178
@ricardoh3178 2 жыл бұрын
What’s the proper way of doing this. Do I take the ground wire from the fixture and wrap it around the screw with extra length at the end then connect that to the ground wire to the house?
@timmarrier
@timmarrier 2 жыл бұрын
@@ricardoh3178 If you mean the ground screw on the fixture bracket, then yes. If you mean the screw in the box, then also yes, although if there's a 'house' ground in the box it should already be wrapped around or pigtailed to the box's ground screw. If not, do that too...if so, connect your fixture ground to the grounding wirenut. That way all grounds are connected (equipotential). Technically the largest awg size ground in the box is supposed to ground the box. Many fixtures come with a smaller ground wire, this can ground the fixture bracket (if supplied, if used, and if it has a green ground screw), and I usually wrap it with length left over to put in the wirenut with the other grounds. Confusing enough? :)
@ricardoh3178
@ricardoh3178 2 жыл бұрын
@@timmarrier sorry, yes I meant the fixture bracket. Yes there is a house ground. If I don’t have another piece of copper to do the pigtail, can I take a piece from the fixture ground since it’s really long?
@timmarrier
@timmarrier 2 жыл бұрын
@@ricardoh3178 Sure, any grounding is better than no grounding. Most lighting manufacturer's instructions usually say to ground the bracket using the ground screw, however the NEC allows the machine screws used to secure the bracket to ground it too, provided it's a metal box that's grounded (to the equipment/circuit ground, or 'house' ground).
@ricardoh3178
@ricardoh3178 2 жыл бұрын
@@timmarrier ok thanks, appreciate it.
@melvinlara-falcone2362
@melvinlara-falcone2362 Жыл бұрын
I hope my videos help DIY out there that’s what I do for a living remodel houses pipes furnaces electrical water heaters furnace drywall flooring porch those on my trades so is it easy to flip houses and make money
@kng2bishop
@kng2bishop 6 жыл бұрын
Scary, light isn't grounded. Kudos for trying to help but that box needs to be grounded.
@jonnyblaze6567
@jonnyblaze6567 9 жыл бұрын
What duck happen to the ground wire
@jamesturner6949
@jamesturner6949 7 жыл бұрын
bad information here - EVERYTHING should be grounded
@tonybanner2982
@tonybanner2982 5 жыл бұрын
This is wrong do not do this if there was pipe going back to breaker box from the light fxicture it would be ok provided the light fixture box is metal as well ,in the breaker box these hard metal pipes the conduit is grounded to the ground bus bar witch in turn the ground bus bar is grounded to a stake in the ground out side with a wire thus creating a true ground from the ligth fixture to the ground outside through the metal pipe hence the Conduit,,,in this example his fixture box is platic there no where for a short or ground to travel if the fixture shorts
@TheDabovich
@TheDabovich 10 жыл бұрын
Thanks mate. Principles are good and it helped me out. Forget about the people 'splitting hairs' in the other comments.
@ButtmanAtHeart
@ButtmanAtHeart Жыл бұрын
Splitting hairs? The point of a ground wire is to give electricity a path to the… ground…. In case of a short. If there is no path to ground for the electricity to travel too it will back feed through the rest of the circuit and destroy any thing attached to it and or cause a fire. Grounding is very important. This is not a path to the ground the way this guy did it. Im not even an electrician and i can tell you this video is wrong
@andrecharette4243
@andrecharette4243 7 жыл бұрын
Wrong
@firstpageforfree3601
@firstpageforfree3601 3 жыл бұрын
Your ground wire is not connected to anything
@LA-Creative
@LA-Creative 3 жыл бұрын
Think this video should be pulled down because it’s dangerous. His solution doesn’t ground the fixture (he would need to find the existing ground wire and connect it to the new system), his wiring is not neatly done and he waits until the end of the video to tell people to turn off the breaker before touching the wires (that could kill people).
@JonathanGarcia-qn3ue
@JonathanGarcia-qn3ue 7 жыл бұрын
this ligth fixture is grounded to nothing, this guy is definitely not an electrician .
@pingkanmutiara8142
@pingkanmutiara8142 7 жыл бұрын
Jonathan Garcia hgxf ytdfffggghhgouyg? 66/76+9+06YAA)
@jimmyleesmith384
@jimmyleesmith384 7 жыл бұрын
so what do i do with the ground wire on a new fixture when i have a house that only has 2 wire wiring?
@poetnk
@poetnk 4 жыл бұрын
@@jimmyleesmith384 Do not connect the ground. That will prevent the metal box from being energized in the event of a short. It's actually safer to simply not have a ground. Ultimately the real solution is to run new romex to the fixtures. Can be very expensive, especially if your panel has no ground bus bar.
@kosmossee4596
@kosmossee4596 4 жыл бұрын
@@poetnk what if plug and wire and switch only has two wire black and white no around....and has to install a plug or switch do u ground it or just leave no ground connected
@ericstin5191
@ericstin5191 4 жыл бұрын
@@poetnk So do you cap off the ground wire on a new fixture if there is no ground wire to attach it to?
@jonnyblaze6567
@jonnyblaze6567 9 жыл бұрын
What the fuck
@cornsronald3710
@cornsronald3710 7 жыл бұрын
You should go to woodprix website if you'd like to make it yourself m8s.
@MrWaterbugdesign
@MrWaterbugdesign Жыл бұрын
Holy crap...he didn't connect the ground (bare wire in Romex) to anything. Connecting the light ground to the screw does nothing at all. That light is not grounded. 911 Likes???? 406k views = how many homes with ungrounded lights???
@SubtIeShot
@SubtIeShot 2 жыл бұрын
This is so bad lmao
@pierluigicolotto9570
@pierluigicolotto9570 7 жыл бұрын
If you want to build it yourself just google for 'woodprix' . I know you'll find good solutions for your idea.
@rinati75
@rinati75 5 жыл бұрын
I don't know how this video came up since I blocked the user. So I reported him because if you follow his instructions, you're risking a serious injury and possibly death.
@BrewerShettles
@BrewerShettles 3 жыл бұрын
you're only blocking for yourself not for others
Most Common DIYer Electrical Mistake - Don't Let This Be You!
10:41
Everyday Home Repairs
Рет қаралды 3,7 МЛН
OMG😳 #tiktok #shorts #potapova_blog
00:58
Potapova_blog
Рет қаралды 4,2 МЛН
Wait for the last one! 👀
00:28
Josh Horton
Рет қаралды 129 МЛН
When You Get Ran Over By A Car...
00:15
Jojo Sim
Рет қаралды 12 МЛН
BIGGEST Mistakes DIYers Make When Connecting Wires Together | How To
13:07
Avoid These Common Light Fixture Wiring Issues
5:53
Everyday Home Repairs
Рет қаралды 201 М.
How To Install A Bathroom Light Fixture
5:28
Making Manzanita
Рет қаралды 150 М.
I Discovered This Hidden Wiring Trick In An Old Forum!
9:24
LRN2DIY
Рет қаралды 384 М.
How To Ground And Bond A Metal Electrical Box
12:21
Why Not DIY
Рет қаралды 175 М.
How to Connect Ground Wires in Light Fixtures
2:06
ExpertVillage Leaf Group
Рет қаралды 156 М.
How To Wire A Light Fixture With Red Black And White Wires
4:01
Conquerall Electrical
Рет қаралды 216 М.
Installing a Light Fixture without a Ground
5:36
Ethan Wingsit
Рет қаралды 98 М.
Дела семейные...
0:59
Это смешно!
Рет қаралды 4,6 МЛН
小丑刚回来,上面到底是谁? #小丑#shorts  #天使
0:24
好人小丑
Рет қаралды 3,1 МЛН
Domino lego #cute #china #construction #train
0:35
construction toy
Рет қаралды 29 МЛН