In this video I will show you step by step how to install an oven/range. We are going to be using a flexible metal pipe with a safety device. www.homedepot.com/p/BrassCraf...
Пікірлер: 24
@Samlol23_drrich Жыл бұрын
I dont know if you own all of the properties that you work on or someone else does, but if you are employed by someone else they should thank their lucky stars to have someone as talented as you. You probably save them hundreds of thousands a year because I wouldn't call what you do "maintenance " You're actually an HVAC tech, electrician, plumber, and speed queen repair tech all rolled into one. Well done as usual
@alexthehandyman3494 Жыл бұрын
Hello Samlo, as usual, very nice of you!!! Thank you so much!! It would be nice if only one of the properties was mine, LOL. Although the owners treat me very nice! I can not complain. Thank you again for your support.
@AnthonyW078 күн бұрын
A plumber that says 'wuh hoo', now who does that reming me of 😅. Great video.
@alexthehandyman34948 күн бұрын
LOL. Thanks for your comment!
@rpsmith Жыл бұрын
Another Great Video! Thanks Alex!
@gregorynolan38036 ай бұрын
Thank you, it was very informative!
@monicat.curenton41429 ай бұрын
Thank you
@jnal213 ай бұрын
Do you recommend the teflon paste over the yellow tape that comes in these kits?
@alexthehandyman34943 ай бұрын
Yes I do . It is double the seal. Double the chance to succeed .
@user-sz9ri9tw6b7 ай бұрын
Nice video. Maybe I missed it but what did you use to test for a gas leak? thanks RR
@AndreC2403 ай бұрын
Soapy water
@jefffree69909 ай бұрын
thanks but i'm confused about the hose used. It looks like you have a 1/2 in OD. But the link takes you yo one that is 5/8 OD, which would seem more appropriate for a large Stove w/ oven. Dont you have to consider what the BTU rating is and match the hose to it?
@alexthehandyman34949 ай бұрын
Hello Jeff, Good catch! However the total BTU for that Range/oven is 48,000 It has only 4 burners. The 1/2 OD flex line that I Installed is rated for 55000 BTU. So totally ok. But I get what you mean. If it was a double oven or bigger burners the 5/8 OD makes more sense. Thanks for your comment.
@R.Gee.Ell.8 ай бұрын
Why you didn’t put the white sealants on the yellow line connector?
@alexthehandyman34948 ай бұрын
Hello. Those connectors are flare connectors. They don’t get any Teflon paste or tape. The seal is at the flare not at the threads . (Metal to metal anything in between jeopardizes the seal )
@gregorynolan38036 ай бұрын
Good question, no tape/sealant on flare connections.
@willierussell13396 ай бұрын
Do you have to plug it up for the burners to come on?
@alexthehandyman34946 ай бұрын
Hello Willie. I’m trying to make sense out of your question. What do you mean? Plug what? What min on the video ? Marry Christmas !!
@Theloadedbarbell10 ай бұрын
Can you explain using a nipple and changing the fitting? I have received a used stove that uses a 5/8 OD hose but my gas line on the wall is 1/2 OD flare valve.
@alexthehandyman349410 ай бұрын
Hello Vanessa, 99.9 % of ranges come equipped with half in male pipe. If that the case on your new used one, just remove the 1/2 fittings and flex line from your old existing one. Look at min 3:01 of the video. It shows 1/2elbow, 1/2nipple, 1/2gas valve, and 1/2 pipe to 1/2 connector. If you buy a new 1/2 lines it will come with two connectors and flex line. That might be all you need. Or use the1/2 flex and connectors you already have and your old existing range and put them on the new (used one ) Just send me a picture of what it comes out of the wall, and I will tell you what you need. Also send me a picture of the range connector.
@martymarr83072 ай бұрын
I got a stove and the old hose doesnt fit the new one and i cant get it off should i just add an adapter
@alexthehandyman34942 ай бұрын
Yes just add an adapter. If your gas flex line is too old (10 yrs or more). I suggest you get a new one.
@brianroadnight78137 ай бұрын
Why did you fail to add a Union?
@alexthehandyman34947 ай бұрын
Hello Brian. You have to be more specific. And site the regulation number you are talking about. I understand a union on a furnace or boiler before the gas valve (as a control device). to be able to service or replace. but not on a range. Different application. The range has a shut off valve. Not a control gas valve .