Brook Hale of His Way Manufacturing replaces a sensor type regulator with a standard type regulator on a John Deere 200 LC Main Hydraulic Pump. Visit www.hwmpumps.com or call 877-651-8473 to find out more about HWM excavator components has to offer!

Пікірлер: 35
@tekingzvlog
@tekingzvlog 2 жыл бұрын
this is very helpful content.on how to replace regulator excavator pump,thumbs up to you sir..
@brookhale9677
@brookhale9677 9 жыл бұрын
Good eyes Butcher! I am not a mechanic, I am the owner of this company. The man is the video is me! Cheers-
@Goldinton
@Goldinton 7 жыл бұрын
Brook Hale can a Kobelco SK120-3 be machanical if we change its regulator to machanical?
@saynotoracism8613
@saynotoracism8613 3 жыл бұрын
I need a job sir from Africa
@jamesthornton1867
@jamesthornton1867 7 жыл бұрын
thank you for the educational video
@sammyblezz542
@sammyblezz542 4 жыл бұрын
My 330 dl hydraulic system is not work even after fixing a new pump
@stevenjbutcher
@stevenjbutcher 9 жыл бұрын
Great Video, Thank You! However you want to be pulling down those M10 Capscrews in "X" Pattern, not square like in the video!
@cEr5ey
@cEr5ey 3 жыл бұрын
Thanks from Russia!
@satyendranishad4117
@satyendranishad4117 5 жыл бұрын
Sir hydraulic service all work video upload kijiye
@lavanyamoola2135
@lavanyamoola2135 4 жыл бұрын
Regulator o ring kit of jaxis 120
@sacariaspiedras5376
@sacariaspiedras5376 4 жыл бұрын
I need regulator of k3v112dt?????
@mouathelhadj4873
@mouathelhadj4873 4 жыл бұрын
thank you sir
@machinerytrader5526
@machinerytrader5526 2 жыл бұрын
sir giveus the reviews about the sinocmp regulators
@Goldinton
@Goldinton 7 жыл бұрын
can a kobelco SK120-3 be machanical if we change the regulator .
@gomanje2001
@gomanje2001 7 жыл бұрын
Goldinton it's already mechanical. Kobelco 120-3 use kawasaki K3v63. this pump normally don't use the proprtional solenoid valve fixed on it. but. Kobelco sk120-5 have kawasaki K3v63 bdt pump. this pump look defrant from out side but rotary group inside is same as old version of K3v63. this pump well not work with out psv solenoid valve
@Goldinton
@Goldinton 7 жыл бұрын
Walid Elmahdy im no expart but sk120-3 hydraulic is having a lot of problems after some guy by passed it without compiter.. worked well for 4 months n now dead. so i tot it must be due to electrical powerd solenoid valves thats r all around the pump n valve boxs . any suggestions?
@gomanje2001
@gomanje2001 7 жыл бұрын
Goldinton contact me in kobelcoeg@gmail.com
@Goldinton
@Goldinton 7 жыл бұрын
wil mail u
@gomanje2001
@gomanje2001 7 жыл бұрын
did you used Han Dok parts. before I need to know your opinion about Han Dok . if you please
@bruce3338
@bruce3338 7 жыл бұрын
Hi. I'm sorry I have no idea about Handok. I just know they are from KOREA. By the way, have you heard "KJC (Kukje hydraulic)"? Their quality of parts is pretty good. They are also spare parts maker from KOREA.
@gomanje2001
@gomanje2001 7 жыл бұрын
kjc not good enough compared with flutek or Han Dok
@bruce3338
@bruce3338 7 жыл бұрын
Thank you for reply. I see. I've found each country have different reputation for spare parts maker. My Iranian mechanic friend told me JIC is quite famous in Iran. I think it is depends on market share of each spare parts maker in the country.
@hidraminanaut9944
@hidraminanaut9944 7 жыл бұрын
we for more than 15 years use handok parts, they perform better than the similar replace ment brands
@muhammadyanto9148
@muhammadyanto9148 5 жыл бұрын
kawasaki part only
@ziaudin1156
@ziaudin1156 8 жыл бұрын
sir my excavater pump work after 2clok atumathic slow what problem
@gomanje2001
@gomanje2001 7 жыл бұрын
Zia Udin pump internal leake. observe hydraulic temperature. if it's hot so it's internal leake
@gulabk65
@gulabk65 6 жыл бұрын
Walid Elmahdy very
@user-zj7cx1mh2y
@user-zj7cx1mh2y 4 жыл бұрын
классный канал
@ellyweking4135
@ellyweking4135 6 жыл бұрын
Mnta petunjuk permasaalan buka baket tdk bisa
@adegalendio4417
@adegalendio4417 5 жыл бұрын
Elly Weking ,,ad beberapa maslah penyebab rot silinder baket tidak berfungsi,, 1-jamet spul cv 2-joistik 3-seal piston dll
@lendellkatwaroo7371
@lendellkatwaroo7371 7 жыл бұрын
Sir, in this case the customer requested to change the electronic regulator to a manual regulator, so in effect the machine would have been converted from an electronic to a manual hydraulic function? can this be done for a HITACHI ex 200-2 electronically regulated pump/controlled pump so as to avoid frequent changing of sensors etc. as these machines begin giving a lot of trouble at their age.
@muhammadfiaz7140
@muhammadfiaz7140 5 жыл бұрын
How to adjust of regulatre hydrulic pump cat m315
How to Install a Hydraulic Pump on an Excavator
9:36
RFE Distribution
Рет қаралды 1,2 МЛН
Excavator Main Hydraulic Pump Receiving Pressure & Flow Rate Test
2:22
RFE Distribution
Рет қаралды 308 М.
마시멜로우로 체감되는 요즘 물가
00:20
진영민yeongmin
Рет қаралды 33 МЛН
Задержи дыхание дольше всех!
00:42
Аришнев
Рет қаралды 2,1 МЛН
DAD LEFT HIS OLD SOCKS ON THE COUCH…😱😂
00:24
JULI_PROETO
Рет қаралды 15 МЛН
Does size matter? BEACH EDITION
00:32
Mini Katana
Рет қаралды 20 МЛН
REXROTH LOAD SENSING DRF DFR PUMP CONTROL EXPLAINED PART 1
10:48
Palyado Walang Lakas Check Engine SUMITOMO SH210-6
8:04
MECHANIC DONG TEAM
Рет қаралды 6 М.
İş Makinaları Hidrolik Sistem Eğitimleri
3:59
Yücel Kılıçkaplan
Рет қаралды 1,6 МЛН
Regulación Rexroth A4VG
5:02
Jesus Mota
Рет қаралды 626 М.
Excavator Swing Bearing Replacement
6:45
skadill
Рет қаралды 1,8 МЛН
Pressure Compensated Pump Adjustments - Part 1
8:34
LunchBox Sessions
Рет қаралды 666 М.
Little Stick Stops The Excavator Dead In Its Tracks!
23:20
letsdig18
Рет қаралды 104 М.
HYDRAULIC PUMP IN 3D
3:33
MadBursa
Рет қаралды 890 М.
Мотоцикл за 10 000 рублей!!! 😳 до конца
0:29
Дарина Мяу
Рет қаралды 1,5 МЛН
Сравнил два перфоратора🤯
0:29
FilmBytes
Рет қаралды 1,3 МЛН
STAGE12 200CC FL-R EN ACTION 🧡🧡
0:49
MAXISCOOT
Рет қаралды 19 МЛН