How to Wire a 4 String PV Combiner Box - Combines Box Wiring for Your Solar Panels

  Рет қаралды 101,089

Ak Electric DIY

Ak Electric DIY

Жыл бұрын

This video is about solar dc combiner box.
in this video tutorial, I will show you solar panels string connection with Combiner Box.
Disclaimer
Video is for educational purpose only Copyright Disclaimer Under Section 107 of the Copyright Act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship, and research Fair use is a use permitted by copyright statute that might otherwise be infringing Non-profit, educational or personal use tips the balance in favor of fair use
Some photos in the video are downloaded from Google Image. The picture used in this video is protected by the Fair Use Law, section 107 used for commentary, criticism, news reporting, or education for transformative use.
Thank You
Other social links
Instagram:
/ ak.electricdiy
Facebook:
profile.php?...
tiktok:
tiktok.com/@akelectricdiy

Пікірлер: 61
@WiSeNhEiMeR-1369
@WiSeNhEiMeR-1369 7 ай бұрын
Thank You Ak-E-DIY, ... Very easy to UNDERSTAND COOP the WiSeNhEiMeR from Richmond, INDIANA ...
@milespraza3374
@milespraza3374 Жыл бұрын
amazing demonstration!
@fadzimeki1117
@fadzimeki1117 7 ай бұрын
Simple easy and understandable illustrations
@MrPmanshimba
@MrPmanshimba 5 ай бұрын
Yeah nice and neat.
@akelectricdiy
@akelectricdiy 5 ай бұрын
Thanks!
@LammiiDirribaa
@LammiiDirribaa 27 күн бұрын
@valramsingh8360
@valramsingh8360 Жыл бұрын
do a video with a large system using recombiner boxes..
@akelectricdiy
@akelectricdiy 7 ай бұрын
Ok, I will
@Boersenwunder-
@Boersenwunder- 5 ай бұрын
Hi! Have you ever heard of the Shoals Plug and Play cables / system? Can anyone judge whether it makes sense to use it? Although they seem to be a bit more expensive, they are extremely easy to use and no professional installer is required. Installation is also said to be very quick and more energy efficient than conventional cables... Some thoughts on it?
@crnibozur4312
@crnibozur4312 6 ай бұрын
Many mistakes in the video. Minus wire also shoud go through fuse, SPD comes after MCB....
@ahmedbencoussa3095
@ahmedbencoussa3095 14 күн бұрын
Hello, how to do it with 4 inverters ?
@PastorJamesAndrews
@PastorJamesAndrews 11 ай бұрын
Instead of going to “inverter in” could you also go to the “charge controller”, then from the “charge controller” to “inverter in”?
@khanyithegreat
@khanyithegreat 9 ай бұрын
some have built in charge controllers
@ratanvishwkarma369
@ratanvishwkarma369 7 ай бұрын
Correct
@raimonbawazir5449
@raimonbawazir5449 23 күн бұрын
thank you for this rich video. can I know the name of this software to draw?
@akelectricdiy
@akelectricdiy 23 күн бұрын
Kinemaster
@p5makersplace
@p5makersplace Жыл бұрын
Using this example, what is the voltage of each panel before series wiring? Also - what gauge wire would then be used on the output feed to the inverter?
@akelectricdiy
@akelectricdiy Жыл бұрын
Complete details in the next upcoming video. Thanks for your comments 🙂
@jfbaro2
@jfbaro2 Жыл бұрын
Is there a type of "combiner box" available that can primarily utilize power from solar panels (when sunlight is available) and supplement its output with grid power (as a secondary source) only when the solar current is insufficient to meet the required output?
@rarefruit2320
@rarefruit2320 6 ай бұрын
That’s the job of the charge controller
@Reels24720
@Reels24720 4 ай бұрын
Make use of string inverter
@ratishcreative5495
@ratishcreative5495 8 ай бұрын
What is the range of floting voltage in 20 pv string
@leehawkins1533
@leehawkins1533 Жыл бұрын
You said it was parallel but you connected as a series string
@ssoffshore5111
@ssoffshore5111 Жыл бұрын
Its parallel at the combiner box
@ericyapi7182
@ericyapi7182 Жыл бұрын
Why only the + cables go to Into the fuses when we have to use the + polarity and - polarity fuses in the junction box?
@MrPmanshimba
@MrPmanshimba 5 ай бұрын
I believe that the Fuse he is using are not 2 pole fuses so that's why.
@internationalbusiness5877
@internationalbusiness5877 22 күн бұрын
What I learned today is that, 1 fuse is 15A and 6 panels parallel-connected to 1 strings is equivalent to 8A x 6 = 48A. Which will overload the fuse and blow if we connect it like your diagram shows.
@gunnerjoe53
@gunnerjoe53 2 күн бұрын
I think there series strings coming in so only 8-11 amps per string.
@AmanKhan-hf6pj
@AmanKhan-hf6pj 3 ай бұрын
Kya Nitrox 6 kw k liye agar do string lagayen to Kya Dono barabar panels k hony chahiye ? Matlab agar aik string 9 panels. Aur dosra 3 panels. ho to Kya Hoga?
@akelectricdiy
@akelectricdiy 3 ай бұрын
Please share with me inverter and solar panels nameplate picture
@AmanKhan-hf6pj
@AmanKhan-hf6pj 3 ай бұрын
@@akelectricdiy Nitrox 6 kw new model hai. Aur JA Solar 545w k 9 panels aik string lagi hoi hai.
@rekedek
@rekedek Жыл бұрын
Can you explain to me why you connect all the (-) and (+) ,except the first (+), together and then conect them with a black (-) cable to the combiner box and in the meantime draw a red (+) cable of the first (+). Instead of connecting separately all the (-) of the panels together and connect them with a black (-) cable to the combiner box and all the (+) together and connect them tο the combiner box with a red (+) solar cable?
@akelectricdiy
@akelectricdiy Жыл бұрын
• All pv strings connected in series The series circuit definition states that a series circuit is a path where the current flows from one component to another through a single path. • In these types of series circuits, the negative terminal of the component is connected with the positive terminal and vice versa.
@rekedek
@rekedek Жыл бұрын
@@akelectricdiy Thanks for your response
@rongray4118
@rongray4118 5 ай бұрын
No mention of size of array/amps/volt/watts...
@rintomarambadjawa5904
@rintomarambadjawa5904 4 ай бұрын
Untuk outputnya dapat brp
@khaleddhr6238
@khaleddhr6238 Жыл бұрын
If i want to use this diagram some times and change all (pv1,pv2,pv3,pv4) to series to use it and return again to first diagram ,How to do that without adding new solar panels?
@sale666
@sale666 9 ай бұрын
This is a series connection looking at the panels... the only thing that makes it parallel is the bus bur.. you should than connect each string to its own fuse and than from the fuse to its own breaker per string... assuming your inverter handles 4 separate strings in
@jmonteen
@jmonteen 10 ай бұрын
What is a Nutrial busbar?
@Digitronix-vb6qm
@Digitronix-vb6qm 2 ай бұрын
neutral bar, its a spelling error
@Digitronix-vb6qm
@Digitronix-vb6qm 2 ай бұрын
its for the negative connections of the PV Panels
@larrymiller7128
@larrymiller7128 Жыл бұрын
If my inverter only has max open voltage of 150, how to I run 16 of 320 w 39 open voltage panels
@akelectricdiy
@akelectricdiy Жыл бұрын
Please send me an inverter name plate picture
@brianimpellizzeri325
@brianimpellizzeri325 8 ай бұрын
3 series max VOC of 117. Parallel depends on ISC and max amps of weakest link in the string. Wire is 30A.
@rintomarambadjawa5904
@rintomarambadjawa5904 4 ай бұрын
Bang,untuk panel surya thin film arus bolang balik,pake pv brpa lembar agar dapat arus ac 220🙏?
@akelectricdiy
@akelectricdiy 4 ай бұрын
In the series string, solar panels voltage is added, and the current remains the same. In parallel string connection, solar panels voltage remaining the same, and current adding this depends on your system
@sunjayjay240
@sunjayjay240 Жыл бұрын
can u show different Voltages per string what wil be addition
@Solar-Sigma
@Solar-Sigma Жыл бұрын
In this scene in the video, the current and voltage of each string should be consistent.
@mosfet500
@mosfet500 Жыл бұрын
Won't work, series voltage is too high for charge controllers in off grid apps. Running long strings is best with microinverters or SolarEdge optimizers in intertie apps.
@charliewatts6895
@charliewatts6895 Жыл бұрын
Agree. Assuming each panel is 25 volts VDC (conservatively), that's 150 volts per string x 4, or 600 volts. That's packing a wallop, and well above any controller (Just the first string along would exceed capability for my off-grid controller). For safety reasons, it's not recommended that 100 volts VDC be exceeded. VDC at the level can kill.
@user-xb2of4sr9q
@user-xb2of4sr9q Жыл бұрын
I have solar panels that are rated 540w My vmpp is 40.5 v I’m aiming to connect them to an inverter that runs a motor for water pumping I will use 64 panels so they can provide 34kw. So I’m using 4 strings each with 16 panels in series If i add up the volts in one string i will end up with 650dcv is that dangerous? Also what do you suggest?
@user-xb2of4sr9q
@user-xb2of4sr9q Жыл бұрын
And also mine is on grid Thanks
@mosfet500
@mosfet500 Жыл бұрын
@@user-xb2of4sr9q According to what you are saying each of your modules puts out 64/34k = 531.3 watts. I think there might be something wrong in your calculations. Microinverters, that is an inverter on each module, run high voltages as the string voltage is the sum of each module. If you're are feeding an inverter or charger controller that runs low voltages you have to make your bank something like 2 modules in series connect in parallel, that is 2 S x 16p, that will give your a total voltage of~81V .according to your VMPP of 40.5 V.
@stefanstosic8379
@stefanstosic8379 Жыл бұрын
@@charliewatts6895 Voltage does not add up across parallel connections, it's the current that increases, isn't it so?
@hlkdmegmailcom
@hlkdmegmailcom Жыл бұрын
I guess, 2 x series panels will only need one Fuse and the rest remain the same? How to calculate the size of FUSE, SPD, DC Breaker? Great video ❤
@akelectricdiy
@akelectricdiy Жыл бұрын
Please wait for the next upcoming video
@Worldsunlightsolarproducts
@Worldsunlightsolarproducts 11 ай бұрын
2 PV strings will need 4Pcs fuses.
PV Combinerbox - step by step DIY tutorial
29:01
Easypowerwall
Рет қаралды 7 М.
Series VS Parallel! A Beginner's Guide for Solar Panel Connections - With Basic Diagrams!
12:36
Jasonoid - Solar Power, Batteries, and More!
Рет қаралды 482 М.
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 62 МЛН
Как бесплатно замутить iphone 15 pro max
00:59
ЖЕЛЕЗНЫЙ КОРОЛЬ
Рет қаралды 6 МЛН
DEFINITELY NOT HAPPENING ON MY WATCH! 😒
00:12
Laro Benz
Рет қаралды 61 МЛН
COMO MONTAR CUADRO DE PROTECCIONES FOTOVOLTAICAS - INVERSORES MONOFÁSICOS
11:22
ENERGY SAVING SOLUTIONS
Рет қаралды 196 М.
How to wire a solar combiner box or pass through box
13:57
EnergyUME
Рет қаралды 35 М.
How to wire different sizes of solar panels together
12:05
EnergyUME
Рет қаралды 103 М.
How to install a Solar DC PV combiner box - 3 String Input 3 String Output
4:31
Surge Protective Device - LSP
Рет қаралды 824
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 62 МЛН