How To Wire Your Main Wires For Sub-Panel Electrical Box For Home Garage Pole Barn

  Рет қаралды 95,760

TipsNNTricks

TipsNNTricks

Күн бұрын

Sub Panel: amzn.to/3t9MjRp
70 Amp Breaker: amzn.to/2PLCnPQ
20 Amp Breaker: amzn.to/3d3cO5w
Lineman's Pliers: amzn.to/322V5ov
My Gear:
Samsung S20+: amzn.to/3osxztR
GoPro 8: amzn.to/3hYnnqU
Wireless Microphone: amzn.to/2TY03yn
Mic: amzn.to/2x5dcII
DJI Mavic: amzn.to/2v4Icex
-----------------------------
UK Shoppers:
Camera Gear-
Samsung S20+: amzn.to/3pt8xvZ
GoPro 8: amzn.to/31cdZtS
Wireless Microphone: amzn.to/3aKFQmo
Mic: amzn.to/2x5wnSM
DJI Mavic Drone: amzn.to/2mCBpVN
______________________
India Shoppers
My Gear:
Mic: amzn.to/2vE4IdM
DJI Mavic: amzn.to/2tQZ3lp
Canon DSLR: amzn.to/2tQDjWF
__________________________
Head To:
My vlog videos: / bensbergfilms
______________________
Want to Buy a cup of coffee for me?
Thank you coffee keeps me making great videos:
Bitcoin Send Here: 1LoMfSUF9p9stdxPqHPnzE3EjcGWfodMMN
PayPal Address: Chrisbensberg@yahoo.com
Ripple XRP Here: rPVMhWBsfF9iMXYj3aAzJVkPDTFNSyWdKy
______________________
Instagram: / chrisbensberg
Like Me On Facebook: / cbensberg
Twitter: / chrisbensberg
______________________
Subscribe Here For More Amazing Videos
/ tipsnntricks
______________________
Thanks for watching.
God Bless
Business Only Please: diysavemoney@yahoo.com
______________________
In this video we show you how to wire your Main Wires to your Sub-Panel for your home, garage, or pole barn. In the next video we'll show you how to wire up your breakers etc. So make sure your subscribed so you don't miss that video. Thank you for your time and thank you for watching.
DISCLAIMER: This video and description contains affiliate links, which means that if you click on one of the product links, we’ll receive a small commission.
#SubPanel #Electrical #DIYHouse #TipsNNtricks

Пікірлер: 125
@jenniferharter1827
@jenniferharter1827 3 жыл бұрын
As of 7/27/2021 this video still has not been corrected. I appreciate that this video was made as it was the only instructional video I could find for this specific box, but in this video both the neutral and one of the hot wires are connected to the neutral bar. The neutral should be where the left hand hot wire is (parallel with the hot wire on the right) and the second hot wire should be connected to the other end of the hot circuit. In this case, the second hot wire connection should be all the way to the left and slightly above the right hand hot wire (if you install the box right-side-up it would be all the way to the right and slightly below the left hand hot wire).
@sergcamargo1343
@sergcamargo1343 2 жыл бұрын
I agree his ass gonna get shocked
@AaronBregg
@AaronBregg 2 жыл бұрын
@jennifer harter Make one for us rookies!
@RandomTechWZ
@RandomTechWZ 2 жыл бұрын
And now that one hot is too short to reach the correct location lol.
@jorgerios1420
@jorgerios1420 Жыл бұрын
They also installed it backwards, and flipped the whole panel around at the end 😂. Look at the breakers before and after
@icandreamstream
@icandreamstream 3 жыл бұрын
For future people watching they incorrectly connected the neutral and hot together on the neutral bus. They fixed it in their next video yet I don’t think they ever mentioned their huge and dangerous mistake. If you have one of these square D sub panels do not do what they did.
@phillipmccain7601
@phillipmccain7601 3 жыл бұрын
Agreed and 10-4 that
@reluctantprophet
@reluctantprophet 3 жыл бұрын
It’s also installed upside down...
@jbdesignandconstruction
@jbdesignandconstruction 3 жыл бұрын
what they should’ve done is deleted this video and made a new one 🤦🏻‍♂️
@pl833
@pl833 2 жыл бұрын
Yeah the video I was like " no....no...no" .
@douglastheriaque5486
@douglastheriaque5486 2 жыл бұрын
Yes, absolutely
@Threshold2012
@Threshold2012 2 жыл бұрын
The older guy says "He was an electrical contractor in another state" Is that where he learned to land a Neutral and a Hot wire to the same buss? You may wonder why they didn't show a circuit test at the conclusion of the video! This video should be flagged for removal due to dangerous and incorrect procedure.
@rcud1
@rcud1 2 жыл бұрын
yeah, you put your hot onto the neutral lug that has plastic around it on 3 sides. The first hot lug is up to the left of that. I almost thought the same thing when I installed mine.
@MC-de6tf
@MC-de6tf Жыл бұрын
The layout on the panel can confuse you if you are not watching close or have not identified hots versus neutral bar it is possible to connect hots and neutral improperly.
@salehprohim9812
@salehprohim9812 2 жыл бұрын
Great video! Thank you!
@donl1410
@donl1410 2 жыл бұрын
Just don't do it like it's shown in the video.
@barrymclaughlin794
@barrymclaughlin794 2 жыл бұрын
This video shows the INCORRECT way to wire this panel, at 6:01 in the video you will see that both the Black (Hot) and the White (Neutral) are connected to the same bus bar. This video should be corrected or removed.
@bobbyj7806
@bobbyj7806 2 жыл бұрын
You clearly aren’t a Electrician
@FastEddieQ
@FastEddieQ Жыл бұрын
Appreciate your time
@aammiranda
@aammiranda 4 ай бұрын
Great video. Thank you
@destroyneverdie2698
@destroyneverdie2698 4 ай бұрын
Thank you so much for the video it definitely helped me out
@RustyPumpkinRanch
@RustyPumpkinRanch 2 жыл бұрын
I bet they got a surprise when they turned the power on, since they hooked the power to the neutral bar.
@RangerMorris
@RangerMorris Жыл бұрын
omg I was just thinking the same thing i was like wait a minute they hooked a hot to a natural omg can we say flash bang lol+
@EnriqueSanchez
@EnriqueSanchez Жыл бұрын
my words exactly
@tedyBear59
@tedyBear59 Жыл бұрын
He did not attach power to neutral bar. He used a black wire wraped in green tape for Id purposes. Its commonly done everywhere
@rongraham1730
@rongraham1730 Жыл бұрын
I thought it was just me😂. I just did one of these so I second guessed myself for a second.
@beaniril8870
@beaniril8870 Жыл бұрын
@@tedyBear59-​​⁠​⁠​⁠-that’s the ground wire. The white/neutral wire and a hot wire all clamped together in the neutral bus bar
@heroknaderi
@heroknaderi 3 жыл бұрын
I enjoyed it. Great job. (Oh the box seemed upside down when you were installing the breakers) I appreciate your time.😁😎👍
@LatrieceWilliams-oy9nc
@LatrieceWilliams-oy9nc Жыл бұрын
Yummy four I saw that's cool yeah always wanted to now what's important and what I should string
@Burtchiropracticrehabilitation
@Burtchiropracticrehabilitation Жыл бұрын
1. Box is upside down, the holes a ground bus bar used for attachment of the box 2. Neutral and hotwire on the same bus bar - hope there is no fire 3. Kudos for doing this box though. Hope these guys are safe
@kcuhc84
@kcuhc84 11 ай бұрын
It's also now code that the breaker "ON" must be up not down like here. The panel has been installed upside down. It would be fine if the breakers went east/west the "ON" can be either left or right.
@user-ko3kt3qs3o
@user-ko3kt3qs3o 5 ай бұрын
Neutral is separated from the hot wire it just looks like they are connected. I have the same box and the way he connected the wire are correct and yes the box is upside down.
@user-ko3kt3qs3o
@user-ko3kt3qs3o 5 ай бұрын
********** Sorry he did connect the hot to the NEUTRAL WTF
@thedailyveteran3101
@thedailyveteran3101 Жыл бұрын
The box is upside down in the beginning. Note the breakers put in. Then note breakers at end. Wonder if when box was turned around if they had some short wires? Reason I noticed it. I have same box. The word Top is engraved inside the back
@TipsNNTricks
@TipsNNTricks Жыл бұрын
Correct, we noticed that and turned it around:)
@thedailyveteran3101
@thedailyveteran3101 Жыл бұрын
@@TipsNNTricksdid it tooo. Lol
@tedyBear59
@tedyBear59 2 жыл бұрын
Great video, right to the point. Thank you Sir
@cpt8424
@cpt8424 Жыл бұрын
It's actually not. This is extremely dangerous how they did this. Copy this method and you will probably die before you have a chance to to praise anyone else's errors and shortcomings
@WaywardZombie
@WaywardZombie Ай бұрын
hope they used a breaker before that panel because that hot n neutral tied together is a dead short
@jerrtheripper1349
@jerrtheripper1349 3 ай бұрын
Wow 😮
@tomg9476
@tomg9476 11 ай бұрын
Yeah, that whole wiring to the neutral bar twice thing got me. Also, the box is upside, so that should’ve been my first clue..
@capnleux
@capnleux 11 ай бұрын
Why not use the lugs?
@phillipmccain7601
@phillipmccain7601 3 жыл бұрын
Why did u put your white parallel to your hot wire this is not right power is on the bottom and Top screw
@jbdesignandconstruction
@jbdesignandconstruction 3 жыл бұрын
Yikes! Could’ve been avoided had he installed it the right way by that I mean not installing it upside down .
@icandreamstream
@icandreamstream 3 жыл бұрын
I just bought this box and was like “wait wtf are they doing!?”
@phillipmccain7601
@phillipmccain7601 3 жыл бұрын
@@icandreamstream yeah I bet when they turned on power they found out real quick that That shit was wired wrong 😑 kinda like a boom 💥 sound idk 🤷‍♂️
@phillipmccain7601
@phillipmccain7601 3 жыл бұрын
@@jbdesignandconstruction yeah some ppl just dumb
@DanielTeague-pr1js
@DanielTeague-pr1js Жыл бұрын
How is this video even still up!!! Totally wired it WRONG !!!
@AA828
@AA828 Ай бұрын
I totally agree.
@bubbleslovebird4974
@bubbleslovebird4974 9 ай бұрын
I only have one hot to connect to it. How do i connect the other side? Ps. Im not electrician savvy but i did catch that mistake.
@GadgetMan777
@GadgetMan777 6 ай бұрын
Was wondering the same. I have heard you can jump them but not sure
@joyceattaway9081
@joyceattaway9081 3 жыл бұрын
you do not put the white neutral to the hot bus bar !!
@Threshold2012
@Threshold2012 2 жыл бұрын
I know what you are saying, but actually they put the White wire where it should be, and the Hot wire on the Neutral buss.
@BruceDuffus
@BruceDuffus Жыл бұрын
The white wire is on the neutral bus, but it should go where they put the first hot wire - the big terminal on the left of the neutral bus.
@mrc9953
@mrc9953 2 жыл бұрын
No one ever includes the install of the breaking in the main panel and wiring the conductors...
@UwwBlake
@UwwBlake 4 ай бұрын
I have a sub panel in my garage like this. I wish there was a cover that actually covered up the breaker switches... not the greatest design.
@JDStaffylover
@JDStaffylover Жыл бұрын
Per Code you must drive a ground rod for a sub panel in a separate building.
@johnrudd4809
@johnrudd4809 3 жыл бұрын
If I was TipsNNTricks I would pull this down.
@keithharrington8715
@keithharrington8715 2 жыл бұрын
Every day is a chance to learn something new. Read through the comments and many people question many things..... Is the panel mounted up-side down? Can you mount the breakers so off is up? Was th panel marked. "THIS END UP"? Did he physically get the wires in the correct place? Does the building require a seperate ground rod and ground wire? What about a building disconnect switch near or on the outside of the building? This may vary based on your local building department. Another videoer got a permit for his "pole bar" as an "agricultural building" which added extra wiring requirements based on NEC 547 (I BELIEVE). Specific wires or conduits based on expected animals housed/stored there. The building department or your local Electricians are great esources to get everything correct. Inspectors go from jobs items to job site and see many different ways it was done and your locals may have solved a problem last week that do not even know you have. Take care and be safe.
@joekirkendall1345
@joekirkendall1345 2 жыл бұрын
No way... I clicked on this vid for a similar project at my house and recognized the voice! Great work guys! Great video! :-)
@johndavies2949
@johndavies2949 9 ай бұрын
You have your panel upside down. Code violation. On a circuit breaker the handle on the breaker must be down in the off position.
@CarlosCastro-ij7nb
@CarlosCastro-ij7nb 2 жыл бұрын
Please Please Do not connect the black hot wire on the right next to the white (incorrect) it should be connected to the far right of this particular panel! This video should be removed before someone gets hurt or cause serious damage to your home. Did like the video very much on instructions on how to install but needs correction if haven’t already!
@Barnabus33
@Barnabus33 2 жыл бұрын
glad someone pointed this out
@donl1410
@donl1410 2 жыл бұрын
Should have been titled, "How NOT To Wire Your Main Wires For Sub-Panel Electrical Box For Home Garage Pole Barn." Totally rookie errors for "dad" being an electrician.. As soon as that 70 amp breaker in the house "blew" they should have reshot the entire episode. I guess KZfaq doesn't protect us from negligent activity, just "naughty" subjects... Panel was initially installed upside down. Ungrounded phase conductor and neutral (grounded conductor) landed on neutral bar. Where is the GEC and Grrounding electrodes? Never was addressed.
@KevinCoop1
@KevinCoop1 2 жыл бұрын
No grounding electrode conductor or electrode? Violation of NEC!
@KevinCoop1
@KevinCoop1 Жыл бұрын
10 months ago I commented that there should be a ground rod (grounding electrode) connected to this panels ground bar as required in Article 250. No comment from anyone! If you do not test the rod to prove 25 ohms or less resistance, then you are required to install two ground rods. The ground rods are for the purpose of sending lightning to Earth, not ground fault in any way.
@alanperez14
@alanperez14 2 жыл бұрын
Take this video down. Yall got it wrong in this video
@jerrynonofbss2588
@jerrynonofbss2588 2 жыл бұрын
To the viewers, don't do as they say and do. Skip this video if you don't want to burn your house down! I can't believe this video is still up. They need to be fact-checked. Also, spend $80 bucks and get a permit to do it, it's worth it if you don't know what you are doing.
@ricksnow8036
@ricksnow8036 Жыл бұрын
Why is this video still up? Hot wired into neutral bar. Boom.
@Baasicstuff
@Baasicstuff 7 ай бұрын
Why is this video still up? 171 thousand subs and you just showed everyone the wrong way to do this. Unbelievable. 72 thousand views....$700 really dude WTF?
@jbear83
@jbear83 11 ай бұрын
I’m glad I’m not the only one who caught they wired it wrong. If you don’t know 100% what you’re doing, DON’T do it. Call a professional, that’s what they are trained for.
@cakeismtrader4227
@cakeismtrader4227 Жыл бұрын
Better have got it inspected and approved by local electrical safety authority
@ronaldtreitner1460
@ronaldtreitner1460 2 жыл бұрын
Among the other things wrong with this, isn't the box upside down.
@kevinmach730
@kevinmach730 2 жыл бұрын
It definitely is- I think that may have been what confused him in incorrectly connecting the neutral and hot to the same conductor.
@FastEddieQ
@FastEddieQ Жыл бұрын
But, please correct the only mistake you made connecting your first hot wire to neutral! Otherwise excellent video👍
@brutally_honest
@brutally_honest Жыл бұрын
wft is going on, is this still wrong?? it looks right to me, I cant figure out if Im stupid or if this was changed. WTF is going on with this video I want to wire my panel tomorrow!! very confusing, the comments. 😅
@FastEddieQ
@FastEddieQ Жыл бұрын
@@brutally_honest yes it is wrong, electrical panel is up side down, but by code it’s still ok, specially if it is place outside under the elements of Mother Nature, but if panel is installed inside it doesn’t necessarily has to be upside down… as far as wiring goes, he installed the main neutral wire to the neutral bar instead of the neutral main slot and then he installed a main hot to the neutral slot, this is wrong… the first hot he installed should’ve have been installed above the neutral main slot the rest was fine.
@FastEddieQ
@FastEddieQ Жыл бұрын
@@brutally_honest in other words where he installed the main hot coming in, this is where your main neutral wire goes, then in this case, above the main neutral slot, there is two more slots were the two main hot go in, hope this helps
@brutally_honest
@brutally_honest Жыл бұрын
@@FastEddieQ I saw that the panel was upside down, and then in the final shot its turned over.. also confusing, like is this the same panel?!! Crazy this is the only video explaining how to wire these things.. I'm going to wire mine and make a video of it so it will be clear, once and for all.
@brutally_honest
@brutally_honest Жыл бұрын
@@FastEddieQ ohh yes i see now he installed the hot to the neutral 🤦🏽‍♂ good catch.
@RedPillLife1966
@RedPillLife1966 2 жыл бұрын
How to burn your house down in 9 minutes and 33 seconds or less.
@2004niteshift
@2004niteshift 2 жыл бұрын
he incorrectly connected the neutral and hot together on the neutral bus
@haboud7051
@haboud7051 7 ай бұрын
Very dangerous, got both neutral and live wire connected together.
@cakeismtrader4227
@cakeismtrader4227 Жыл бұрын
This is so wrong take this video down before others get hurt
@m3thid
@m3thid 3 жыл бұрын
The hot and neutral connections are not right, see the other comments! Delete this video!
@Jat0ne
@Jat0ne 7 ай бұрын
For real!?
@mathieuchenier9551
@mathieuchenier9551 2 жыл бұрын
Thought I was crazy but the comments proved me right. For the love of pete, don't connect your hot wire to the neutral bar...
@adamortega914
@adamortega914 3 ай бұрын
Ain't no way
@beaniril8870
@beaniril8870 Жыл бұрын
The funny thing here is these two clowns sound like they really know what they were doing. Neutral bus bar and live wire together?
@ZPDSurvival
@ZPDSurvival 2 жыл бұрын
Very Dangerous.
@itzBiscuitsB
@itzBiscuitsB 5 ай бұрын
ya ummmm CAUTION folks
@norsk54472
@norsk54472 Жыл бұрын
do a continuity check first
@thomasharman7079
@thomasharman7079 2 жыл бұрын
They should not go near anything electrical !
@paulflores4331
@paulflores4331 2 жыл бұрын
Where the hell is part 2?????
@cakeismtrader4227
@cakeismtrader4227 Жыл бұрын
They didn’t get that far
@3636054
@3636054 Жыл бұрын
As Monty Python (John Cleese) would say, "Let's not worry about WHO killed WHO."
@constantbrousseau7758
@constantbrousseau7758 21 күн бұрын
It’s also not legal because the panel was mounted upside down. Lol😂
@jbdesignandconstruction
@jbdesignandconstruction 3 жыл бұрын
Do not turn it on!!
@everettogden8132
@everettogden8132 2 жыл бұрын
You should really delete this video because of the incorrect install, dangerous.
@keltecshooter
@keltecshooter Жыл бұрын
The most bassakward video ever, this is a dangerous video and should be taken down
@robsp32
@robsp32 2 жыл бұрын
What the hell? I followed these instructions and now my shed burned to the ground.
@stanloos552
@stanloos552 10 ай бұрын
You hooked your first hot wire to the neutral lug. Don't do a video if you don't know what your doing!
@makojuicedaniel9307
@makojuicedaniel9307 2 жыл бұрын
No one wants to show where ot hooks into tge main box
@tankbrook
@tankbrook 2 жыл бұрын
are you trying to kill someone????? please take this down. you wired the hot in the neutral bar
@fizwin1
@fizwin1 2 жыл бұрын
This is the messiest video I have ever watched. I installed the exact same panel years ago and of course mine looks nothing like this... We know they wired it wrong, and why would you NOT use the main lug for the Neutral? That should have caught your mistake right away!!!. Sorry guys thumbs down. Take this video down.
@cakeismtrader4227
@cakeismtrader4227 2 жыл бұрын
Dangerous Wired that wrong don’t do it like this he has hot and neutral on same bus 🤦🏽‍♂️ and box is upside down 🤦🏽‍♂️
@cakeismtrader4227
@cakeismtrader4227 2 жыл бұрын
I wonder what the out come of this was ? Probably felt dead and alive at the same time for a few seconds.
@FastEddieQ
@FastEddieQ Жыл бұрын
It doesn’t matter if sub-panel is upside down, unless it is outside then yes otherwise the only problem I see is a wiring mistake… please correct me if I’m wrong.
@cakeismtrader4227
@cakeismtrader4227 Жыл бұрын
@@FastEddieQ that’s right but it’s not recommended unless you have no other option also need 30min fire wall and so much distance around panel
@FastEddieQ
@FastEddieQ Жыл бұрын
10/4
@richardschumacher7072
@richardschumacher7072 2 жыл бұрын
Should be taken off , trying to be respectful but this is very dangerous to leave posted!!!!!!
@richardschumacher7072
@richardschumacher7072 2 жыл бұрын
Box upside down that should be a clue , please remove this garbage!!!!!!
@foxbmd15
@foxbmd15 3 ай бұрын
Prolly should be making videos if you don’t know what your doing your going to kill somebody looking for information that your giving improperly this is wired completely wrong nobody do what they did
How To Install a Sub Panel Start to Finish!
31:44
Benjamin Sahlstrom
Рет қаралды 2,3 МЛН
How to Install a Subpanel
15:35
Got It Made
Рет қаралды 1,4 МЛН
Опасность фирменной зарядки Apple
00:57
SuperCrastan
Рет қаралды 12 МЛН
ОБЯЗАТЕЛЬНО СОВЕРШАЙТЕ ДОБРО!❤❤❤
00:45
小宇宙竟然尿裤子!#小丑#家庭#搞笑
00:26
家庭搞笑日记
Рет қаралды 18 МЛН
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,3 МЛН
Why I Failed my detached garage rough In Electrical Inspection
19:59
Justin's Project
Рет қаралды 189 М.
10 Common Mistakes DIYers Make In Circuit Breaker Boxes
13:55
LRN2DIY
Рет қаралды 2,3 МЛН
Installing a Sub Panel for Heater & Welder + 50amps in the Garage
17:42
How To Wire A Sub Panel - VERY DETAILED INSTALLATION! Start To Finish
49:02
The Excellent Laborer
Рет қаралды 474 М.
How to Install and Wire a Sub Panel
35:23
SgtDonovan
Рет қаралды 1,3 МЛН
Sub Panel Install - Start to Finish - Outbuilding | Shop | Barn | Garage
21:05
Can You Install a Sub Panel On a 120v Circuit - Discussion & In-Use Example
8:04
BYD U8 танковый разворот
1:00
YOUR NEW AUTO
Рет қаралды 3,8 МЛН
Inside out 2 hard color game
0:14
Nazar family
Рет қаралды 16 МЛН
¡Toro cerril en Useras! (¡Espectacular!) #toros #useres #bull
0:19
Multi Toros
Рет қаралды 18 МЛН
Dad thought daughter wanted his food #shorts
0:10
The Nixon Fam
Рет қаралды 30 МЛН
😳 Это ПРЕВРАЩАЕТ всё в ПИЦЦУ !
0:28
Настя, это где?
Рет қаралды 8 МЛН
Misti Ke Gadi Ke Niche Billi 🐱😻 | mistihappylifestyle #shorts #viral #funny #comedy #cute #cat
0:19