HVAC: LG MULTI V Heat Recovery Heat Pump Not Cooling/Not Heating (Error Code CH 42) Error Code CH43

  Рет қаралды 5,864

Jumper man Tech

Jumper man Tech

Күн бұрын

LG MULTI V Heat Recovery Heat Pump Not Cooling/Not Heating (Error Code CH 42) Error Code CH43 / LG Low Pressure Sensor Fault / LG High Pressure Sensor Fault / LG Multi V 4 Concealed Duct Preventive Maintenance (LG Air Handler Cleaning) LG HVAC Cleaning / LG HVAC Error Code / LG Multi V / LG Multi V Heat Pump / LG Multi V Heat Recovery Unit / LG HVAC Maintenance / LG HVAC Heat Pump / LG Heat Pump / HVAC Service Call: LG Multi V Not Heating Or Cooling (LG Wired Thermostat Keeps Turning OFF and ON) How To Check LG Thermostat / How To Test LG Thermostat / LG Premtc00u manual / LG Premtc00u Troubleshooting / LG PQRCVCL0QW Manual / LG PQRCVCL0QW Troubleshooting / LG MULTI V Not Heating Or Cooling (LG Error Code CH21) LG HVAC Troubleshooting / LG MULTI V 4 Error Code CH26 Repair (Inverter Compressor Overcurrent) LG MULTI V IV Compressor & Inverter Board Replacement (LG MULTI V 5 Repair) HVAC (Heating, Ventilation, Air Conditioning) Service Call: LG Multi V IV Error Code CH29 (Inverter Compressor Over Current) Error Code 291 / LG MULTI V 5 ERROR CODE CH29 - Outdoor Unit Inverter Compressor Over Current ( Outdoor Unit Inverter Compressor Fault Or Drive Fault) LG Troubleshooting / HVAC VRF VRV Training / LG MULT V Not Cooling (LG Multi V 5 Error Code CH26) VRF Troubleshooting/Repair / HVAC (Heating, Ventilation, Air Conditioning) / (LG Multi V 5 Error Code CH26/Error Code 261) LG Error Code CH21 / LG Error Code 211 / LG Error Code CH26 / LG Error Code 261 / LG Error Code CH29 / LG Error Code 291 / LG Error Code 21 / LG Error Code 211 / LG Error Code CH21 / LG HVAC Training / LG HVAC Troubleshooting / LG VRV / LG VRF / LG Heat Recovery Heat Pump / LG Heat Pump / #HVAC #LG #HEATPUMP #JUMPERMANTECH
GoPro HERO8 Black (Camera Used In This Video)
amzn.to/3q4FmEz
Veto Pro Pac TECH MC
amzn.to/3gURJyZ
Fluke 902 FC HVAC True-RMS Clamp Meter
amzn.to/39wvwiK​​
Fieldpiece ADK7 Deluxe Silicone Test Lead Kit
amzn.to/3VNYXDv
Klein Tools ET600 Megohmmeter Insulation Tester
amzn.to/409iNvu
Supco M500 Insulation Tester/Electronic Megohmmeter
amzn.to/42oy0ua
Fluke 1AC-A1-II VoltAlert Non-Contact Voltage Tester
amzn.to/3FcWElQ
Fieldpiece JL3KR4 HVACR Charge Kit (Digital Gauges/Probes)
amzn.to/3E4W0Fr
Fieldpiece SPK2 Folding Pocket In-Duct Thermometer
amzn.to/3mi8Fih
Fieldpiece SPK3 Folding ROD Dual Temperature Thermometer
amzn.to/3FbDufQ
Milwaukee M12 2-Tool Combo Kit 2598-22
amzn.to/3CtCRNC
Milwaukee Cut 1 Dipped GLOVES L
amzn.to/3s8H18O​
Milwaukee 2351-20 M12 LED Stick Light
amzn.to/3rVJKEK
Milwaukee 48-22-1985 Fastback Hawk Bill Folding Knife
amzn.to/3e53ygW
Milwaukee 48-22-1500 Fastback Compact Folding Utility Knife
amzn.to/3qazJkC
Milwaukee 48-22-4041 Iron Carbide Core Large-Looped Jobsite Scissors
amzn.to/32fxC6I
Milwaukee 4932459097 Billet Torpedo Level
amzn.to/30Dh6Nw
Milwaukee Wide Blade Magnetic Tape Measure 16 FT
amzn.to/3yEN7kL
Milwaukee Fine Pt. Markers Black
amzn.to/3e4fH5W
Streamlight 66604 MicroStream USB 250-Lumen Rechargable Pocket Flashlight
amzn.to/320XiEF
Klein Tools 11-in-1 Screwdriver / Nut Driver
amzn.to/3s3o8ql
Klein Tools 32561 Multi-Bit Screwdriver / Nut Driver 6-in-1
amzn.to/3e4ur4x
Klein Tools 32807MAG 7-in-1 Nut Driver, Magnetic Driver
amzn.to/321n4bW
Klein Tools 600-4 1/4-Inch Keystone Cushion-Grip Screwdriver
amzn.to/3J11hS1
Klein Tools 32581 4-in-1 Electronics Screwdriver Set
amzn.to/3yEj3WC
Klein Tools LLK12 L-Style Hex Key Caddy Set 12-Piece (Metric/Sae)
amzn.to/3yRUiGJ
Yellow Jacket 18975 Charge Tool
amzn.to/3J4pfvJ
Yellow Jacket 60613 Service ratchet Wrench
amzn.to/3E8iYeZ
Yellow Jacket 19173 5/16" Female Quick Couplers x 1/4" Male Flare
amzn.to/3q0TQ4M
Cooper Bussmann BP-FP-2 Cartridge Carded Fuse Puller
amzn.to/3e0USrY
Crescent 2 Pc. X6 4-in-1 Black Oxide Spline Ratcheting SAE Wrench Set
amzn.to/3qqKlw7
Crescent 4" Adjustable Cushion Grip Wrench
amzn.to/3J4qsmL
Knipex 09 08 240 SBA 9.5-Inch Insulated Ultra-High Leverage Lineman's Pliers (1000v)
amzn.to/30EQmw5
Knipex 09 11 240 9.5-Inch Ultra-High Leverage Lineman's Pliers with Fish Tape Puller and Crimper
amzn.to/3H9iYAu
KNIPEX Tools - Long Nose Pliers With Cutter, 1000V Insulated
amzn.to/3e3IEi7
KNIPEX Tools - Long Nose Pliers With Cutter
amzn.to/3gUSE2i
KNIPEX Tools 98 62 02, Flat Nose Plastic Pliers 1000V Insulated
amzn.to/3p6lFsZ
KNIPEX - 74 08 200 - High Leverage Diagonal Cutters, 1000V Insulated
amzn.to/3mh8K5U
KNIPEX - 74 01 200 Tools - High Leverage Diagonal Cutters
amzn.to/3F1VScb
KNIPEX Tools - Cobra QuickSet Pump Pliers, 1000V Insulated
amzn.to/3sftr5Q
KNIPEX Tools 3 Piece Cobra Pliers Set
amzn.to/3FbRwy7
KNIPEX Tools Pliers Wrench 3-Piece Set
amzn.to/3nnRLfW

Пікірлер: 91
@oldblueaccord2629
@oldblueaccord2629 2 ай бұрын
We love the shots of the NYC skyline. Thank you!
@JumpermanTech
@JumpermanTech 2 ай бұрын
Glad you do! It does look really nice. You're very welcome & thanks for watching🙏🔧⚡️🤙
@tschuuuls486
@tschuuuls486 2 ай бұрын
I just had a peek in the service manual. The unit should go into lockout when high pressure is >581PSI or low pressure
@tschuuuls486
@tschuuuls486 2 ай бұрын
The FW Update process looks a bit involved. You need "LG GSFS" access where you should find firmware updates. They need to flashed with a special dongle called "FLD2". Maybe they include changelogs and reference what has been fixed, not sure.
@tschuuuls486
@tschuuuls486 2 ай бұрын
And one more thing: The jumper settings right next to the display look like they are all set to off. This means it's running in compatibility mode for Gen2 indoor indoor units. If all indoor units are newer than 07/2016 jumper 3 should be set to on.
@oldblueaccord2629
@oldblueaccord2629 2 ай бұрын
@@tschuuuls486 Nice leg work on this.
@samakagi4239
@samakagi4239 2 ай бұрын
Thanks again for creating these video presentations. If you did add oil back to the system how would you determine the amount and would you use a pump? I study your work for my own benefit. Medic467, WA state.
@Eddy63
@Eddy63 2 ай бұрын
Beautiful Skyline... Film the repair please ... Excellent vid JMT ... Thx
@ronnym1977
@ronnym1977 2 ай бұрын
Jumper Man Tech, you really know your trade, and I really enjoy your videos.
@mwdub02
@mwdub02 2 ай бұрын
Gotta add PVE oil buddy, also gotta have a magnetic solenoid to open that solenoid when you braze so you won’t plug the upper and lower EEVs. Good luck on this one, it’ll be a bit of a headache.
@JumpermanTech
@JumpermanTech 2 ай бұрын
Thank you for the advice! Def a headache. I see it needs PVE oil and a viscosity of 80 but no other information. Tech support just said to call my parts provider and there is only one and they don't answer emails or phone calls. Is there something you recommend? Thank you. Thanks for watching & commenting! 🙏🔧⚡️
@mwdub02
@mwdub02 2 ай бұрын
@@JumpermanTech you should get it from Klima NY or NJ, I got it from their NJ branch last month. I work on these systems everyday so I deal with them a lot. I can’t stress enough about flowing nitro and opening solenoids with the CPS magnets though. Good luck and let me know if you need help with any questions.
@mwdub02
@mwdub02 2 ай бұрын
The oil is FVC68D that’s viscosity of 68, you can find at the supply house website. I don’t know why they told you 80.
@JumpermanTech
@JumpermanTech 2 ай бұрын
@mwdub02 @mwdub02 Correct. Klima is the only distributor and they have poor communication. Never answer the phone and it takes a long time to hear back from email. When we need parts, it's right away and it's sad they are just not avaliable unless the building stocks up on things. Thank you for your advice! I have solenoid magnets and appreciate the info!
@JumpermanTech
@JumpermanTech 2 ай бұрын
@mwdub02 @mwdub02 Thank you for that info! Idk why they said that either and wouldn't allow me to talk to tech support as I wasn't on site during the time of the call. I did some research online and found that exact oil. I picked up 32oz earlier today from a local HVAC supplier. Really appreciate it brother. I always run nitro when brazing. That creates so much damage in these systems. Changing the compressor, inverter board and adding some oil tomorrow in hopes to get them going. I fixed the leak the other day but the compressor failed mechanically even though it checked out electrically. We don't have a new solenoid valve and I told them to wait for the parts but they need it asap and are willing to pay to see what happens so I'll do my best. Thank you for watching & commenting! 🔧⚡️
@HVACK
@HVACK 2 ай бұрын
Think of the bright side..... you don't need to condemn the building this time. LOL
@JumpermanTech
@JumpermanTech 2 ай бұрын
Next time 😂😂 Thanks for watching!
@wolfpack7598
@wolfpack7598 2 ай бұрын
I used to believe in everything made, LG. (Life’s Good). Thought they were so.. energy efficient, all & everything! Hmm. Seems.. lots of possible poor design, faulty parts/boards, etc. & from where.. (China)!? But.. No in-side Maintenance Certainly doesn’t help anything, either!! Great Vid. Jumper Man Tech.👍
@F12255
@F12255 2 ай бұрын
Just saw your truck on the service road of the LIE today by lefrak 💪
@JumpermanTech
@JumpermanTech 2 ай бұрын
Haha that's awesome. Queens get the money! 😂🔧⚡️ Say hello next time & stay tuned for new videos every week! Enjoy your weekend brother 🤙
@F12255
@F12255 2 ай бұрын
@JumpermanTech will do bro. I was trying but i was in the middle lane on the 495. love the videos. keep up.the good work! 💪🏽
@RoaddogRoaddog
@RoaddogRoaddog 2 ай бұрын
Awesome troubleshooting
@JumpermanTech
@JumpermanTech 2 ай бұрын
Thank you my friend! Thanks for watching 🙏🔧⚡️
@brad6566
@brad6566 2 ай бұрын
Very thorough job! Nice
@JumpermanTech
@JumpermanTech 2 ай бұрын
Thank you! Stay tuned for new videos every week🙏🔧⚡️
@aus_aircon_ref_mech6671
@aus_aircon_ref_mech6671 2 ай бұрын
Great video!!! Overtime 🥹🥹🥹. Great leak find! Had one of those hard to reach leaks on a Daikin VRV. Hate VRV’s because they are always installed by your local plumber 🤩🤩🤩🫣🫣🫣who knows NOTHING about HVAC-R. Looking forward to the repair video.
@JumpermanTech
@JumpermanTech 2 ай бұрын
Thank you brother! Leaks can be hard to find. Especially in places like the one found. Luckily but unluckily it was so large so I could actually hear it. I hear that! Not a fan of VRV's either. Over complicated and constant issues. Local plumber haha stay tuned for the follow up video this Saturday! Stay safe out there & thanks for watching 🔧⚡️
@bohanger6315
@bohanger6315 2 ай бұрын
I ran into this a couple times, decided I wouldnt get that brazed up without damaging the valve internals. Just order the valve or use a third party 208v in a real pinch. Might as well add a shrader in there for future work so you can isolate the condenser.
@johnwalker890
@johnwalker890 2 ай бұрын
Good job Jumper.......
@JumpermanTech
@JumpermanTech 2 ай бұрын
Thank you!! 🙏🔧⚡️
@closg1930
@closg1930 Ай бұрын
Lol 🤣 you know you been hvacing too long when you can smell it
@joshuabest100
@joshuabest100 2 ай бұрын
Haha the way you said "thats oil"
@JumpermanTech
@JumpermanTech 2 ай бұрын
😂😂😂 New York style. Thanks for watching! 🙏🔧⚡️
@bmillwood6666
@bmillwood6666 2 ай бұрын
A building like that should have a set of compressors on stand by as well as sensor kits and inverter boards.
@npakkonen
@npakkonen 2 ай бұрын
Excellent diagnostics. Just on monday we changed the compressor on a Mitsubishi city multi. But we don’t have such beautiful views.😂😂
@jrh86
@jrh86 2 ай бұрын
Superb video thank's again lads 💯👍👍👍
@JumpermanTech
@JumpermanTech 2 ай бұрын
Thank you brother! Much appreciated 🙏🔧⚡️🤙
@oldmetalguy4577
@oldmetalguy4577 2 ай бұрын
The LG cash cows!
@JumpermanTech
@JumpermanTech 2 ай бұрын
💯💯💯 Facts! Thanks for watching🔧⚡️
@stevencossaboon3237
@stevencossaboon3237 2 ай бұрын
Nice work Jumper man.
@JumpermanTech
@JumpermanTech 2 ай бұрын
Thank you very much!! 🙏🔧⚡️🤙
@dimaslespier2688
@dimaslespier2688 2 ай бұрын
Bru I feel sorry for those people who invested all that money in a top of the line VRV system thinking they were doing the right thing? All to have a mickkey mouse company install it such a shame. And yes it alway recommended to replace the inverter board with those compressors as that board is the contactor!
@oldblueaccord2629
@oldblueaccord2629 2 ай бұрын
I think here in TN they see all that oil and just replace the whole unit. We dont have troubleshooters. Billy bob puts a new unit on his back and climbs up 10 stoires....few hook ups this that and badda bing badda bang its in the bag as they say in New Yawk.
@topshorter5492
@topshorter5492 2 ай бұрын
The sun is going down 😂
@JumpermanTech
@JumpermanTech 2 ай бұрын
The sun is going down while the bank account is going up 😎🤙🔧⚡️ Thanks for watching!
@andyreyes6464
@andyreyes6464 2 ай бұрын
good job my man
@JumpermanTech
@JumpermanTech 2 ай бұрын
Thank you brother! Thanks for watching 🔧⚡️
@wolfpack7598
@wolfpack7598 2 ай бұрын
P.S. Additional Comment. I’ve seen introduction booklets from China, example (for a VCR, etc.) where the instructions, literally ended halfway thru. the instructions! Buying some of their electronics also. Either cheap made & don’t even include chargers (the other half of the system) when selling, lol. Ugh! Geese..
@zekenzy6486
@zekenzy6486 2 ай бұрын
Great video. Thank you for sharing. Have a nice weekend. What is name apps you're using on phone ? is the apps work for all brand VRF unit ?
@jorgeuribe4512
@jorgeuribe4512 2 ай бұрын
What do you mean license torch operator and fire guard license?
@JumpermanTech
@JumpermanTech 2 ай бұрын
For New York City you need to have two licenses from the fire department. F60 (Torch use of flammable gases) & G60 (Fire guard). Both need to be on site and both need to have the licenses to perform any hot work such as brazing or soldering. Thanks for watching!
@kennethlobo4420
@kennethlobo4420 2 ай бұрын
Pls post the follow up video.❤
@ayoutubewatcher7009
@ayoutubewatcher7009 2 ай бұрын
Why would you change the compressor and inverter board for a leak? Pull it out, drain it and refill to factory amount..
@sherwinalvarez7365
@sherwinalvarez7365 2 ай бұрын
Oh yeah?
@JumpermanTech
@JumpermanTech 2 ай бұрын
Most likely the unit failed due to the leak and loss of oil. Came back for the following visit to fix the leak & the compressor failed mechanically even though it checked out electrically. Locked rotor. Now it's double the work. Thanks for watching🔧⚡️
@JumpermanTech
@JumpermanTech 2 ай бұрын
@sherwinalvarez7365 Should have replaced the compressor while the gas was out. We fixed the leak and the compressor failed mechanically enough though it checked out electrically. Locked rotor 🤦‍♂️ considering how many compressor failures there have been here, not surprised. Should've replaced it but it was worth a shot to start it up since it checked out electrically. Thanks for watching! 🤙🔧⚡️
@tschuuuls486
@tschuuuls486 2 ай бұрын
I would've thought the system would lock itself out long before oil becomes a problem. You might want to check with your LG Tool if there are Firmware Updates available for those machines. According to LGs marketing the Multi V should even have oil level sensors to make sure this doesn't happen. EDIT: Maybe the previous company disabled oil level sensing or something?
@JumpermanTech
@JumpermanTech 2 ай бұрын
@tschuuuls486 I agree with you. Everytime there's an error, in house engineers reset the units which isn't good so that maybe played a role but if the low pressure or high pressure sensor is open, nothing should start and protect the compressor. Yes, there is an oil sensor built in the compressor and has 2 wires. That should have protected the compressor too, but it didn't. Definitely something needs to be checked here and dive deeper into what happened here. What good are all these safeties if they aren't protecting what it should? Thanks for watching & your comment! Stay tuned for new videos every week 🔧⚡️
@thesilentonevictor
@thesilentonevictor 2 ай бұрын
Supertech job jmt
@JumpermanTech
@JumpermanTech 2 ай бұрын
Thank you brother!! Thanks for watching🙏🔧⚡️
@mansourramzey7711
@mansourramzey7711 2 ай бұрын
Using the torch needs to be licensed? I thought if an ac technician is licensed, he can use torch.....
@JumpermanTech
@JumpermanTech 2 ай бұрын
Yes, you need a license from the NYC fire department for "Torch use of flammable gases" & "fire guard". Both the torch operator and fire guard need both licenses. A licensed HVAC usually means having your EPA Section 608 Universal license but that has nothing to do with hot work. Usually you also need a hot work permit from the fire department but many don't do that. Thanks for watching! 🔧⚡️
@austinkraus756
@austinkraus756 2 ай бұрын
What app or website is that to look up the error codes?
@JumpermanTech
@JumpermanTech 2 ай бұрын
"LG HVAC SERVICE-BUSINESS" app. Its a MUST to have when working on any type of LG units. Thanks for watching! 🔧⚡️
@commenter5469
@commenter5469 2 ай бұрын
You using megger wrong. When you holding that button - you should run 1 minutes and 10 minutes tests. It is not for testing whether motor failed, but for the maintenance records, to monitor and/or predicting when motor going to fail. To test whether motor or circuit has failed - you press test button for 1-2 seconds, and device will do it automatically.
@oldblueaccord2629
@oldblueaccord2629 2 ай бұрын
I dont think those hand helds can go the 10 mins.
@commenter5469
@commenter5469 2 ай бұрын
@@oldblueaccord2629 They do. There’s even the “hold button”. Just need to make sure that batteries are fresh.
@oldblueaccord2629
@oldblueaccord2629 2 ай бұрын
The problem with motor prediction is you need the new installed numbers to compare to the current numbers so that test doenst mean much otherwise. It told him the windings were ok, proceed.
@commenter5469
@commenter5469 2 ай бұрын
@@oldblueaccord2629 Well - he was holding the button, and that’s not how regular “quick test” is done.
@ILoveKittys78
@ILoveKittys78 2 ай бұрын
😻💚💜💚
@JumpermanTech
@JumpermanTech 2 ай бұрын
🩷🔧⚡️
@emadmansour7259
@emadmansour7259 2 ай бұрын
Next time isolate the condenser from the ball valve
@genewheeler6320
@genewheeler6320 2 ай бұрын
Those units seem like garbage
@JumpermanTech
@JumpermanTech 2 ай бұрын
They are not so great and come with a lot of problems but there is no maintenance for the indoor units connected to these outdoor units. Definitely playing a huge role as well. Thanks for watching! 🔧⚡️
@Adeadcop702
@Adeadcop702 2 ай бұрын
The girlfriend calling is so real
@chris66b55
@chris66b55 2 ай бұрын
Low Pressure, here we go!
@JumpermanTech
@JumpermanTech 2 ай бұрын
Here we go!! 💰🤙🔧⚡️
@JumpermanTech
@JumpermanTech 2 ай бұрын
Thanks for watching!
@Rodj12341
@Rodj12341 2 ай бұрын
The troubleshooting steps for CH42/43 are very misleading. They should of made one of the reasons that the unit ran out of refrigerant and to check pressures before assuming the low/high pressure sensor is bad. Though just because all of the refrigerant leaked out, doesn't mean that the compressor needs changed. We had an EEV leak out of its head completely and the compressors still ran fine after replacing the EEV and recharging, though that was on a system with more than one outdoor unit connected together. When trying to find a leak on the ODU side, it's best to close off the service valves and connect your guages to the ports inside the unit(Not where the service valves are) so that way you do not waste nitrogen on the indoor unit piping.
@oldblueaccord2629
@oldblueaccord2629 2 ай бұрын
It ran all the oil out of it...thats never a good sign.
@tschuuuls486
@tschuuuls486 2 ай бұрын
I looked this up and the unit thought the hp/lp pressure sensor failed and it didn't run out of refrigerant. The board will calculate superheat etc. to cross-vaidate the sensors. Unit thought the sensor died, ran the compressor and killed itself. There are seperate error codes for hp, lp/loss of charge. Sounds like a critical firmware bug to me.
@Rodj12341
@Rodj12341 2 ай бұрын
@@tschuuuls486 Yeah, that's one thing I've noticed during slow refrigerant leaks that it continues to try running, even with all IDU's at fully open EEV(1350 steps), and it doesn't error out until it gets critically low. There is an error for low refrigerant pressures(CH 35), but I've never seen it go off on this error before something else happens from low pressures.
@tschuuuls486
@tschuuuls486 2 ай бұрын
​@@Rodj12341 This sounds very broken. I'm not a tech at all just was curious. You could look into "LG GSFS" where you should find firmware updates. They need to flashed with a special dongle called "FLD2". Maybe they include changelogs and reference those issues?
@benkuxhouse787
@benkuxhouse787 2 ай бұрын
God that looks miserable
@JumpermanTech
@JumpermanTech 2 ай бұрын
Oh it's a nightmare 😂🔧⚡️
@JumpermanTech
@JumpermanTech 2 ай бұрын
Thanks for watching! 🔧⚡️
@hellhound-si5oz
@hellhound-si5oz 2 ай бұрын
Yes, I know that smell and it's not nice
@JumpermanTech
@JumpermanTech 2 ай бұрын
💯💯💯 Facts! Thanks for watching 🤙🔧⚡️
FREE Solar Heating & Air Conditioning Is Finally Here...
21:08
The DIY HVAC Guy
Рет қаралды 986 М.
Пройди игру и получи 5 чупа-чупсов (2024)
00:49
Екатерина Ковалева
Рет қаралды 4 МЛН
Challenge matching picture with Alfredo Larin family! 😁
00:21
BigSchool
Рет қаралды 43 МЛН
Чёрная ДЫРА 🕳️ | WICSUR #shorts
00:49
Бискас
Рет қаралды 6 МЛН
Schoolboy Runaway в реальной жизни🤣@onLI_gAmeS
00:31
МишАня
Рет қаралды 3,7 МЛН
THE AC KEEPS TRIPPING THE BREAKER
35:03
HVACR VIDEOS
Рет қаралды 510 М.
Why is Everyone Talking about Heat Pumps?
9:15
JerryRigEverything
Рет қаралды 527 М.
Typical HVAC unit LEAKING refrigerant & How I Fixed it.
17:37
Quality HVACR
Рет қаралды 39 М.
Пройди игру и получи 5 чупа-чупсов (2024)
00:49
Екатерина Ковалева
Рет қаралды 4 МЛН