HVACR: Refrigeration Service Call (Walk In Refrigerator Not Cooling) Compressor Not Starting/Working

  Рет қаралды 57,593

Jumper man Tech

Jumper man Tech

2 жыл бұрын

HVACR (Heating, Ventilation, Air Conditioning/Refrigeration) Refrigeration Emergency Service Call (Walk In Refrigerator Not Cooling/Walk In Refrigerator Not Working) Beer Cooler Not Working/Compressor Not Starting/Working/How To Check Compressor/How To Check Run Capacitor/How To Check Start Capacitor/Commercial Refrigeration/Walk In Cooler Troubleshooting
=================================================
LINKS TO PURCHASE:
Veto Pro Pac Tech Pac MC (Compact Tech Pac)
amzn.to/2ZGttI4
Fluke 902 FC HVAC True-RMS Clamp Meter
amzn.to/39wvwiK​​
Fieldpiece JL3KR4 HVACR Charge Kit (Digital Gauges/Probes)
amzn.to/3E4W0Fr
Milwaukee Cut 1 Dipped GLOVES L
amzn.to/3s8H18O​
Yellow Jacket 60613 Service ratchet Wrench
amzn.to/3E8iYeZ
=================================================
Walk-in refrigerators and freezers are very large, insulated, enclosed spaces used to store and/or display refrigerated or frozen food or other perishable goods. They are used primarily in the food service and food sales industry.
A Walk-in cooler is basically a large scale refrigerator - similar to what you have at home - except you can walk into this one! Every restaurant and fast food chain has a Walk-in cooler and it’s where they store all their refrigerated foods. Unlike a residential refrigerator though, a Walk-in cooler has a lot stronger refrigeration system that allows them to keep their food stored at optimal temperatures in order to meet certain FDA standards and to ensure that it passes local safety and food handling codes.
Businesses from a wide variety of market segments use Walk-in coolers from Floral Boutiques to Breweries to Medical Research Facilities. Walk-in boxes come in all shapes and sizes and depending on the business’s needs, a Walk-in box can come with a lot of unique add-ons and accessories such as thermometers and temperature alarms that monitor temperature inside the box. If a business needs more than just a Walk-in Cooler, they can order a Walk-in Freezer or a Walk-in Combo Box which features to sections inside the box, one cooler and one freezer section.
Walk-ins are constructed using panels. Walk-in Box panels easily lock into place via cam lock and can be installed right over most flooring’s (though you can purchase a Walk-in Box floor separately).
A typical Walk-in Box can range anywhere from thousands of dollars to tens of thousands of dollars depending on many factors such as size, horsepower of Refrigeration unit, add-ons, panel thickness, location (indoor and outdoor) etc.
=================================================
Follow me on instagram! @JumperManTech
For all inquiries E-mail JumperManTech@Gmail.com

Пікірлер: 97
@hecherr1121
@hecherr1121 8 ай бұрын
Thx for the confirmation. I've guessed from the start that it could be the capacitor when you mentioned that the compressor was trying to start. Right now, im in school for hvac and subscribed and definitely going to watch your service call videos to learn some more 😊.
@nicolerennie
@nicolerennie 2 жыл бұрын
fantastic job!! I really appreciate how thorough you are w your craft & make sure you do it RIGHT & CLEAN & WELL. TY JMT🌟
@JumpermanTech
@JumpermanTech Жыл бұрын
Thank you! Stay tuned for new videos every week🔧
@altralitycomforthvacr4337
@altralitycomforthvacr4337 Жыл бұрын
Love it man. I would be one of those guys to double check to make sure if the part is 100% bad but love your trouble shooting process
@salimlemdani
@salimlemdani 2 жыл бұрын
You too man. I was looking for this kind of explanation and demonstration that is very rare. Hope to see the video when you did the work on this unit. Well done bro.
@salimlemdani
@salimlemdani 2 жыл бұрын
Top man
@TheSlim2none
@TheSlim2none Жыл бұрын
Love those field piece probes a must for any real tech.
@wd8557
@wd8557 2 жыл бұрын
The proper and ( SAFE ) way to discharge a capacitor is to set your meter on D/C voltage and put your probes on cap, and It will slowly start to drain it. I won 50 bucks off a guy one time when I told him I could OHM out a capacitor and find out if it's good or not. He goes I don't give a fk who taught you refrigeration you can't ohm out a cap. So we go to his van he get's out a cap I take his meter set to DC and drain it. Then I go NOW I am going to set your meter to Ohms and use your 9 volt battery in your meter to charge this capacitor If it's good you will start to see the readings rise which it did because it was new. After he picked his jaw up off the ground and handed me 50 bucks he drove off highly upset.
@kennethalovera2976
@kennethalovera2976 Ай бұрын
Damn bro thanks for the tip. gonna try me to score 50 bucks as well
@jsnxng7578
@jsnxng7578 11 ай бұрын
Hey jumperman great videos I’m currently at the tail end of my HVACR program and I have to say your videos are very help and gives a good insight on what day to day service calls look like. Thanks
@eduardoruiz6482
@eduardoruiz6482 10 ай бұрын
Same here
@sauceghandi2799
@sauceghandi2799 9 ай бұрын
I just started my program but im excited
@betenacity8238
@betenacity8238 2 ай бұрын
Same here 💪🏽🙌🏼👌🏽
@binyammamo6454
@binyammamo6454 Ай бұрын
You are really good man. I watch this several time.
@keorapetsefoli9652
@keorapetsefoli9652 7 ай бұрын
Good job with fault finding, and you are right wires not looking good. Wiring must be neat and easy to follow. Please share your follow up video links.. Thank you.
@beaut9206
@beaut9206 Жыл бұрын
Watched this video in my tech school. Thank you for sharing.
@izzybell11
@izzybell11 2 жыл бұрын
Interesting and helpful video. Great job as always.
@JumpermanTech
@JumpermanTech 2 жыл бұрын
Thank you! Appreciate your comment & support 🙌🔧⚡
@DavidMartin-yr9ym
@DavidMartin-yr9ym 2 жыл бұрын
You the man bro keep knocking them down
@JumpermanTech
@JumpermanTech Жыл бұрын
Thank you! Stay tuned for new videos every week🔧⚡️
@BLOODSWEATXXXSTEEL
@BLOODSWEATXXXSTEEL 11 ай бұрын
Nice work and great integrity
@blessingmasiyaw3984
@blessingmasiyaw3984 Жыл бұрын
Thank you for the videos Jumperman Tech , i would some videos on BMS 💯
@leonardhannah1045
@leonardhannah1045 Жыл бұрын
Good details in describing everything
@resurgensix
@resurgensix Ай бұрын
Always great content my man!
@JumpermanTech
@JumpermanTech Ай бұрын
Thank you brother! Stay tuned for new videos every week🔧⚡️🤙
@musakavalci9470
@musakavalci9470 2 жыл бұрын
As always excellent content
@JumpermanTech
@JumpermanTech 2 жыл бұрын
Thank you Musa! Appreciate you! 🙌🔧⚡
@dangerhellbender3245
@dangerhellbender3245 Жыл бұрын
I like your get it down right work. Thanks for sharing
@JumpermanTech
@JumpermanTech Жыл бұрын
Thank you! Stay tuned for new videos every week🔧
@davidchsw
@davidchsw 2 жыл бұрын
Good video. When you have a potential relay there should be a bleed resister on the start capacity.
@JumpermanTech
@JumpermanTech Жыл бұрын
💯 safety first! Thank you! Stay tuned for new videos every week🔧
@thesilentonevictor
@thesilentonevictor 2 жыл бұрын
Great work tech 👍
@JumpermanTech
@JumpermanTech 2 жыл бұрын
Thank you dude! Appreciate it🤙🔧⚡
@HICDIY
@HICDIY Жыл бұрын
Great job my friend lots to learn share ...❤
@danielsaldana4663
@danielsaldana4663 4 ай бұрын
Right on man great job
@carlosemmanuelgarciabrito791
@carlosemmanuelgarciabrito791 2 жыл бұрын
Nice and precise good work
@JumpermanTech
@JumpermanTech 2 жыл бұрын
Thank you! Appreciate the feedback🙏 Stay tuned for new videos every week 🔧⚡
@mikedavis6023
@mikedavis6023 10 ай бұрын
Very informative
@Eddy63
@Eddy63 2 жыл бұрын
Good vid ... Thx for posting ...
@JumpermanTech
@JumpermanTech 2 жыл бұрын
Thank you Eddy! Appreciate the comment🙏 Stay tuned for new videos every week 🔧⚡
@mansourramzey7711
@mansourramzey7711 2 жыл бұрын
Great video
@JumpermanTech
@JumpermanTech 2 жыл бұрын
Thank you! Appreciate the feedback🙏Stay tuned for new videos every week 🔧⚡
@timcastilo6962
@timcastilo6962 2 жыл бұрын
Should have slugged some refrigerant in it to keep their food cold till the next weekday then come back and do a leak search
@erickglo436
@erickglo436 Жыл бұрын
That’s probably what he did off camera. It’s illegal to do that if you know there’s a leak in the system.
@stangaloski4208
@stangaloski4208 8 ай бұрын
It's illegal? Really?
@aidanc3049
@aidanc3049 8 ай бұрын
​@stangaloski4208 its most definitely illegal in Europe anyway as if you know its leaking you might aswel vent refrigerant out to atmosphere
@JustinBurito
@JustinBurito 4 ай бұрын
In the United States it needs to exceed a leak rate for it to need to be condemned
@DABOSSnova
@DABOSSnova Ай бұрын
Ur not supposed to do dat goofy
@mattalexander8919
@mattalexander8919 2 жыл бұрын
Nice Video, I enjoyed it. But seriously?? A light with a cord and plug.
@JumpermanTech
@JumpermanTech 2 жыл бұрын
Thank you! Haha I always use the M12 cordless drop light but it went missing so I went with the cord! Lol. Hate using a cord😂 Stay tuned for new videos every week 🔧⚡
@gedyx
@gedyx 10 ай бұрын
Hey Boss excellent breakdown, i have a question, I'm studying for a test which type of cartridge fuse used in a industrial refrigeration one time fuse, time delay fuse, tube fuse with reset or plug fuse with reset?
@wasimedoo7994
@wasimedoo7994 2 жыл бұрын
Nice job
@JumpermanTech
@JumpermanTech Жыл бұрын
Thank you! Stay tuned for new videos every week🔧⚡️
@Artisan.HVACR1
@Artisan.HVACR1 2 жыл бұрын
I noticed at the 4:22 time stamp you stated even though the system was marked as R-12, it was actually using R-134a. I understand that your reasoning for that statement was the phaseout of R-12 many years ago. However, if that system was actually using R-134a as you stated, it should have been CLEARLY remarked by the contractor that did the work with R-134a identifiers to indicate a refrigerant retrofit took place on the system. That is standard procedure for all refrigerant retrofits. Since that wasn't done, many technicians would think that was an old R-12 system that never went through a retrofit. Also, the low pressure switch setpoints would tell a technician if the cut-in and differential setpoints were set on the correct setpoints for the refrigerant type being used. I would look at those setpoints to see if they were truly set up for R-134a or if the setpoints were set up for R-12 pressure/temperature. That system could just be an old system that has stood the test of time and still has R-12 in it. I use the phrase "stood the test of time" until now that you were dispatched on to this service call where it has obviously finally shut down.
@LC-qi5ff
@LC-qi5ff 8 ай бұрын
Very good points
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 жыл бұрын
Are they using a boiler for heat add for the loop? Anytime i work on a coaxial system i always do a quick backflush, unless its glycol. It takes a few minutes and very little amount of tools ( i don't disagree with your methods at all ) that unit needs some help
@amfmechanicbowlingcommunit5048
@amfmechanicbowlingcommunit5048 Жыл бұрын
I am interested in learning more about this walk in freezers. I like the way you explained it. What of brad and kind of tools you use to check the high and low on the compressor?
@MariosACandRefrigeration
@MariosACandRefrigeration 2 жыл бұрын
Those compressors are not cheap to put a titen 2.60 $ instead of usa hd for $6.00 I would not take the chance.thanks for the vid,keep posting.
@marcushahn6750
@marcushahn6750 Жыл бұрын
To the wall next fly please and thank you
@rocker8692
@rocker8692 2 ай бұрын
Jumper man,are jumper man tech cause you are a master jump roper?
@jonstevens7032
@jonstevens7032 9 ай бұрын
I would have fixed it on the spot.. Id have found the leak, fixed the leak, reclaimed the system, and recharged it. No need for a second service call.
@delrey-p
@delrey-p 4 ай бұрын
Most people would reclaim it then repair and recharge it instead of repairing it, reclaiming it then recharging it.
@citricdemon
@citricdemon Ай бұрын
If it were me, I'm built different, so it wouldn't be problem
@robertpeters9438
@robertpeters9438 Жыл бұрын
You need to cover or remove the food products below.
@JumpermanTech
@JumpermanTech Жыл бұрын
Good advice. Thank you! Stay tuned for new videos every week🔧⚡️
@rishijagnarine1806
@rishijagnarine1806 4 ай бұрын
What refrigerant was that system using?
@hg2.
@hg2. Жыл бұрын
I didn't see the link in the description for the follow-up video.
@JumpermanTech
@JumpermanTech Жыл бұрын
Thanks for pointing that out & for watching! Stay tuned for new videos every week🔧⚡️ Follow up video link (Refrigerant Leak Repair) kzfaq.info/get/bejne/bdl5drdqkpbScYU.html
@mahrez5244
@mahrez5244 Жыл бұрын
Nice man , i wanna put my foot in a field may i work with you couple times for free just to learn more ?
@dirt5547
@dirt5547 Ай бұрын
If you would like to learn something about refrigeration, you can ask.
@richardharmon874
@richardharmon874 2 жыл бұрын
Why no 409a?
@Face426
@Face426 Жыл бұрын
I got freezer room but it does not go less than 10 degrees.
@WIINNER1040
@WIINNER1040 3 ай бұрын
Jump man where you located
@shine-cg9uf
@shine-cg9uf 2 жыл бұрын
💪🇺🇸👍❄
@JumpermanTech
@JumpermanTech 2 жыл бұрын
Thank you! 🙏🙌🇺🇲🔧⚡
@LuchambeeLuchambee
@LuchambeeLuchambee 8 ай бұрын
What's the cost of job like that
@primetime758
@primetime758 2 жыл бұрын
Just a question have you been doing this long? or are you a rookie
@harryschrysan3183
@harryschrysan3183 26 күн бұрын
I recon that both caps got destroyed because of the compressor was short cycling constantly.
@jyphc1679
@jyphc1679 2 жыл бұрын
You should use R422B is compatible with R 22 mineral oil. R134A is POE OIL
@JumpermanTech
@JumpermanTech 2 жыл бұрын
This was not a R22 system. It was a R12 system and the replacement is R134a👍Thanks for watching!
@rolandgirouard5914
@rolandgirouard5914 2 жыл бұрын
@@JumpermanTech only with an oil change kiddo. If you're not replacing the oil then you should use 209 and not 134
@MrAtlasJude
@MrAtlasJude 6 ай бұрын
0:01 light switch
@bxnorris2002
@bxnorris2002 Жыл бұрын
after hours heading to a wine cellar not working, first time working on one 😅
@JumpermanTech
@JumpermanTech Жыл бұрын
Just another day in paradise 🥂😂 Stay tuned for new videos every week🔧
@nielsdaemen
@nielsdaemen 8 ай бұрын
Follow up on this?
@monchichipower6334
@monchichipower6334 4 ай бұрын
Prefer jobs that are routine This industry it’s always a different thing
@elconodetumai13
@elconodetumai13 Жыл бұрын
134a
@simplybuyer1
@simplybuyer1 6 ай бұрын
What can you earn as a technician
@richardharmon874
@richardharmon874 2 жыл бұрын
Where was leak.i bet it was on evap
@Brad-ns1no
@Brad-ns1no 3 ай бұрын
The last thing a tech should do is open up the system, even to just hook up a probe
@citricdemon
@citricdemon Ай бұрын
Yeah, unless that's what the problem is. Then it should be the first thing.
@KobeOverLebronAllDay
@KobeOverLebronAllDay 2 жыл бұрын
you should never discharge a start cap like that...use your meter or a resistor.
@gabrielmendoza9165
@gabrielmendoza9165 Жыл бұрын
Checking pressures is not the first thing you should do buddy
@walkingoverabridgeman2729
@walkingoverabridgeman2729 Жыл бұрын
Real techs don’t use shitwaukee tools
@lonewolf-sd2ko
@lonewolf-sd2ko Ай бұрын
Should have top off with refrigerant . Full siteglass. 134 a tefrigerant. Discharged the compacitor with a screw driver on both terminals.
Walk in Freezer service call  (electric defrost explained)
27:37
HVACR VIDEOS
Рет қаралды 233 М.
Каха и суп
00:39
К-Media
Рет қаралды 2,9 МЛН
Вечный ДВИГАТЕЛЬ!⚙️ #shorts
00:27
Гараж 54
Рет қаралды 14 МЛН
孩子多的烦恼?#火影忍者 #家庭 #佐助
00:31
火影忍者一家
Рет қаралды 49 МЛН
HVACR Refrigeration Cycle Training! Superheat and Subcooling!
10:01
AC Service Tech LLC
Рет қаралды 174 М.
You're wasting money on heating! Use your A/C!
17:11
Tech Ingredients
Рет қаралды 312 М.
WALK IN FREEZER WITH TOO MUCH FROST
14:52
HVACR VIDEOS
Рет қаралды 460 М.
How a Supermarket Refrigeration System Works
8:45
HVACR Career Connect NY
Рет қаралды 58 М.
Walk-In Cooler Warm and Compressor Is HOT
12:26
HVACR Survival
Рет қаралды 14 М.
Late night walk in freezer call
17:12
HVACR VIDEOS
Рет қаралды 371 М.