Inspecting a Gas Furnace with Certified Professional Inspector® Julie Erck

  Рет қаралды 17,234

International Association of Certified Home Inspectors (InterNACHI)

International Association of Certified Home Inspectors (InterNACHI)

Күн бұрын

Пікірлер: 53
@drossington
@drossington 2 жыл бұрын
I'm leaving teaching public school after 16 years and becoming a home inspector. Your videos have been super helpful. Thank you!
@internachi
@internachi 2 жыл бұрын
That is awesome! If you need anything, we're all on www.nachi.org/contact.htm
@luzmarinalarezvalledechall6740
@luzmarinalarezvalledechall6740 2 жыл бұрын
Great video, thanks, perfect comments. I just became a CPI, learning a lot from your videos, empowering women into this path.
@internachi
@internachi 2 жыл бұрын
Glad it was helpful!
@michaeloconnor9905
@michaeloconnor9905 2 жыл бұрын
I agree with Phil and also I would like to add that the gas MUST make a 90 degree turn into the appliance so that gravity can catch any condensate or debris and drop into the sediment trap. Theres no turn at this trap where gravity would properly cause debris or condensate to collect in the trap. It’s improper installation
@boby115
@boby115 2 жыл бұрын
Michael, I noticed the same thing 👍, I call that orientation of the sediment trap / drip leg.
@internachi
@internachi 2 жыл бұрын
Good catch.
@internachi
@internachi 2 жыл бұрын
Nice.
@carterbeck
@carterbeck 2 жыл бұрын
Great video Empowered Home Inspections and InterNACHI! Really like the walk through and sequence of proper function of the unit.
@julieerck9125
@julieerck9125 2 жыл бұрын
Thanks! Jacob is a talented videographer.
@internachi
@internachi 2 жыл бұрын
Thank you.
@How2Stu
@How2Stu 10 ай бұрын
Hey Julie, nice to meet you at the 2023 Convention.
@internachi
@internachi 6 ай бұрын
Thanks for watching our videos. Be sure to subscribe.
@Mel007ize
@Mel007ize 2 жыл бұрын
Knowledgeable and beautiful lady. Good job 👍
@internachi
@internachi 2 жыл бұрын
Thank you!
@tuvoca825
@tuvoca825 2 жыл бұрын
Thanks for posting and all your work to mentor newbies like me! Almost certified! Your videos are very helpful! This is above the visual only standards, as you said, but knowing what a basic inspection (beyond the standards) might entail may be helpful.
@julieerck9125
@julieerck9125 2 жыл бұрын
Welcome to home inspecting! It is fun and rewarding. When I go beyond the scope of a visual only home inspection, I am (mostly) consistent and I note it in my report.
@internachi
@internachi 2 жыл бұрын
Thank you.
@sidehustlers336
@sidehustlers336 Жыл бұрын
I learn so much in a short 20 minutes from you
@internachi
@internachi Жыл бұрын
She's a great inspector.
@user-nc9nz2om4m
@user-nc9nz2om4m 4 ай бұрын
Cracks on the hot surface igniter will usually cause a no gas/flame condition.
@internachi
@internachi 4 ай бұрын
Right.
@phillatshaw7219
@phillatshaw7219 2 жыл бұрын
Why didn’t you call out the sediment leg on the wrong side of the appliance fuel shutoff valve?
@julieerck9125
@julieerck9125 2 жыл бұрын
Good question. I look for the presence of the drip leg to be installed at any low point on the piping, not necessarily before or after the shut off valve. I will do more research and adjust my inspections accordingly. Thanks for the question.
@boby115
@boby115 2 жыл бұрын
Phil,it is preferred the shut-off valve proceed the drip leg but per the National Fuel code I do not believe it is required unless they made some recent changes but the drip leg is still installed wrong ,it's at the wrong orientation ( very little debris would be caught a In it's present orientation).👍🛠
@phillatshaw7219
@phillatshaw7219 2 жыл бұрын
Section G2419.3 in the 2018 IRC states the drip is to be readily accessible to permit cleansing or emptying and not subject to freezing. If it is installed prior to the appliance shutoff you would need to shutoff the main fuel shutoff to drain it. I guess that is acceptable by code just not very convenient. However G 2419.4 in the 2018 IRC states where a sediment trap is not incorporated as part of the appliance one must be installed downstream of the appliance shutoff valve. A sediment leg is meant to catch sediment and forces gas to change direction. A drip leg is meant to catch condensation and may also catch sediment, however a drip leg does not need to be located in a manner to force the gas to change direction.
@boby115
@boby115 2 жыл бұрын
@@phillatshaw7219 , consumer Natural Gas is considered dry gas by today's standards. When I started working for the natural gas utility industry back in 1983 the gas wasn't purified and as clean as today's gas. That being said horizontal drip legs are becoming something of a dinosaur . Occasionally some utilities put them on the outlet of the gas meter in areas with warm climates but in my opinion the chances of collecting water nowadays would be rare. Sediment traps ( Direction changing ) are required for all stationary gas appliances and equipment/ I believe by all manufacturers ( the exclusion would be gas dryers,gas ranges ,cooktops, gaslights, decorative gas logs and grills). Some states and municipalities prohibit the use of sediment traps on outdoor equipment subject to freezing temperatures but I feel these states and municipalities are wrong and causing more Danger due to debris and unlikely water entering the gas control ( as a matter of fact Generac generators come with a built-in sediment trap). It's not uncommon for codes such as IRC, NFPA 54 GAMA & the AGA to contradict one another. It's like putting 4 attorneys in the same room and coming up with 5 different opinions. My suggestion is to do whatever your local code enforcement Authority requires.
@internachi
@internachi 2 жыл бұрын
Good question. Thanks for posting.
@jamespatterson1433
@jamespatterson1433 Жыл бұрын
Great job I certainly learned somethings there. Thank you
@internachi
@internachi Жыл бұрын
Thanks for watching the video and for replying.
@orangeblossomhomeinspectio432
@orangeblossomhomeinspectio432 2 жыл бұрын
I'm going to use this for my template comment observations!! EXCELLENT content!!! One question... is the smoke detector required? I rarely see it. Thank you, Mrs.Erck!!! John Grimaldi CMI and InterNACHI Home Inspector Mentor
@julieerck9125
@julieerck9125 2 жыл бұрын
Thank you! Glad it is helpful. I check with local building codes for smoke detector requirements as they vary with individual authorities having jurisdiction.
@internachi
@internachi 2 жыл бұрын
Yep.
@jon10231
@jon10231 2 жыл бұрын
Smoke detector requirements are found in the ICC-IRC. You can look up online for the local jurisdiction, I doubt they would have amended them out, but maybe, added in other locations that are not in the IRC like an attic.
@gregschwartz6886
@gregschwartz6886 2 жыл бұрын
I would look at taking a look at the earthquake straps on the water heater. Do they need them in her area?
@julieerck9125
@julieerck9125 2 жыл бұрын
Good eye.. The UPC requires water heaters in seismic zones 3 and 4 to be anchored or strapped to resist horizontal displacement due to earthquake motion. This location was in a zone 1. That will be in my inspection of the water heater.
@internachi
@internachi 2 жыл бұрын
Thank you.
@johnathanrobello271
@johnathanrobello271 4 ай бұрын
Vibration isolators between plenum and furnace or furnace duct? Or is the plenum a part of the duct system 🤷‍♂️
@internachi
@internachi 3 ай бұрын
Correct. Good point.
@smacleod69
@smacleod69 Жыл бұрын
Furnace doesn't need combustion air because it has the fresh air intake to the burners.
@internachi
@internachi Жыл бұрын
I appreciate that! Thanks for watching. I teach free online classes for inspectors at www.nachi.org/webinars. Free, online, and open to everyone.
@hotshotryder5624
@hotshotryder5624 2 жыл бұрын
That is not CSST that is a gas appliance flex supply line.
@boby115
@boby115 2 жыл бұрын
HSR,you are correct that is an appliance connector and not csst. If it were yellow csst she would then be dealing with bonding to the electrical panel's grounding rod.👍🛠
@internachi
@internachi 2 жыл бұрын
Right.
@internachi
@internachi 2 жыл бұрын
Thanks.
@user-cf2px2ko8y
@user-cf2px2ko8y 10 ай бұрын
A link with the checklist would have been nice.
@internachi
@internachi 6 ай бұрын
The checklist is on www.nachi.org/home-inspection-checklist.htm
@user-cf2px2ko8y
@user-cf2px2ko8y 6 ай бұрын
​@@internachiThank you!
@Real_Rob_Reels
@Real_Rob_Reels 10 ай бұрын
What about checking voltage with a multimeter?
@internachi
@internachi 6 ай бұрын
That could be done, but it's up to each inspector to exceed the standards of practice.
@Real_Rob_Reels
@Real_Rob_Reels 6 ай бұрын
i think that's standard practice.
@johnsonjay60
@johnsonjay60 4 ай бұрын
Yourl are just looking no instruments? Just notes? Lol This is not an inspection this is someone pointing at things.. "we cant determine that" !? 😅
@internachi
@internachi 3 ай бұрын
A home inspection is a visual-only observation.
Inspecting a Water Heater with Julie Erck, CPI
3:01
International Association of Certified Home Inspectors (InterNACHI)
Рет қаралды 3,2 М.
Performing a Home Inspection with InterNACHI® Certified Professional Inspector CPI® Jim Krumm.
1:05:03
International Association of Certified Home Inspectors (InterNACHI)
Рет қаралды 747 М.
Parenting hacks and gadgets against mosquitoes 🦟👶
00:21
Let's GLOW!
Рет қаралды 13 МЛН
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Паша Осадчий
Рет қаралды 1,1 МЛН
Lehanga 🤣 #comedy #funny
00:31
Micky Makeover
Рет қаралды 29 МЛН
Чёрная ДЫРА 🕳️ | WICSUR #shorts
00:49
Бискас
Рет қаралды 4,8 МЛН
Tips on Inspecting Furnaces with CPI Lon Henderson
32:03
International Association of Certified Home Inspectors (InterNACHI)
Рет қаралды 22 М.
"Inspecting HVAC Systems for Home Inspectors" Webinar with Eric Grubbs
1:52:59
International Association of Certified Home Inspectors (InterNACHI)
Рет қаралды 20 М.
No Heating Service Call Trane Gas Furnace wait for it ....
10:02
Anti DIY HVAC
Рет қаралды 100 М.
80% vs 90%+ Condensing Furnace
17:56
Love2HVAC with Ty Branaman
Рет қаралды 98 М.
How to Perform an Electrical Inspection According to the InterNACHI® SOP
24:21
International Association of Certified Home Inspectors (InterNACHI)
Рет қаралды 89 М.
Forced-air Furnaces: The What, Why, and How
22:05
Technology Connections
Рет қаралды 1,3 МЛН
Performing a Plumbing Inspection According to the InterNACHI® SOP
38:13
International Association of Certified Home Inspectors (InterNACHI)
Рет қаралды 26 М.
How to Perform a Heating Inspection According to the InterNACHI® SOP
10:49
International Association of Certified Home Inspectors (InterNACHI)
Рет қаралды 38 М.
Parenting hacks and gadgets against mosquitoes 🦟👶
00:21
Let's GLOW!
Рет қаралды 13 МЛН