This video will show you how to install 15KW Solar PV System and help you understand how the system operates.
Пікірлер: 160
@abdulrahmanmuhammad6205Ай бұрын
Honestly when we talk of proffessional work this is a very good example. Kudos to the camera man and the editor. I hope to see more of videos like these on this page.❤
@DNC2.0Ай бұрын
Thanks Muhammad really appreciate your wonderful comment and by the way I am the camera man and the editor.
@austinsagba7098Ай бұрын
Thanks. I appreciate the fact every beginner can follow up and understand the step by step approach to I stalling a solar system form the video. Great job. Great team. Top notch Professional work.
@DNC2.0Ай бұрын
Thanks Austin really appreciate it
@wnderjuan234420 күн бұрын
Very Professionally done! You deserve to have many more clients! Hello from Manila!
@DNC2.020 күн бұрын
Thank you so much bro really appreciate the positive energy
@wnderjuan234420 күн бұрын
@@DNC2.0 Im studying solar now and this video really inspires me! Thanks bro
@DNC2.019 күн бұрын
@@wnderjuan2344 you're welcome bro
@sushanthsrkrАй бұрын
Thats what I call the informative video. All my installation doubts are cleared.
@DNC2.0Ай бұрын
Thanks mate always happy to help
@powerwall7 күн бұрын
Great.We have wall mounted battery as well.
@mbyesowe78282 ай бұрын
Good job young men. Am proud 👏
@DNC2.02 ай бұрын
Thanks sowe really appreciate it and maybe it's all because of the calculations we did in class 😂
@simonemmanuel9734Ай бұрын
Dem. This is standard. Every tolls are complete. When it comes to professional I give it to you guys. I wish u guys are in Nigeria I would have given you guys job instantly
@DNC2.0Ай бұрын
Thanks bro really appreciate it but we're located in the Gambia 🇬🇲
@madouceesay21512 ай бұрын
Thank you so much bro the installation is so neat and easy to understand ❤
@DNC2.02 ай бұрын
You're welcome bro
@eddyidemudia735621 күн бұрын
Nicet to see this Guys doing the Job with passion
@DNC2.020 күн бұрын
Thanks mate really appreciate the possitive comment 👍
@ikediashitimothyonuorah4172 ай бұрын
Omo see clean job! I shall definitely call you guys to come install my EG4 18kpv soon
@DNC2.02 ай бұрын
Thanks really appreciate it but which country are you located
@larutadelosmilagro3706Ай бұрын
Felicidades jóvenes buen trabajo
@meilyn22Ай бұрын
18KPV can only be used in the United States and Canada or countries with 120v/240v and 60hz split phase. If you live in Nigeria, that inverter isn't for you. You need a 230v single phase inverter with 50hz. You need an inverter with L1 and Neutral. Not one with L1 and L2. Understand what you are doing before buying something you won't be able to use without a transformer.
@atobskyАй бұрын
The panels themselves should be grounded to Earth ..The SPD is not enough especially in a large setup like this
@ousmanamnjie98692 ай бұрын
Nice and clean job my bosses
@DNC2.02 ай бұрын
Thanks mate
@user-xe7bw4gq1f24 күн бұрын
Nice job!❤
@DNC2.022 күн бұрын
Thanks! 😄
@adanbouzouaАй бұрын
Good job!
@DNC2.0Ай бұрын
Thanks mate
@keyable25 күн бұрын
Great work, would be nice to see the schematics of the project 🙏
@jonesnyuykighan6300Ай бұрын
Excellent job
@DNC2.0Ай бұрын
Thanks man
@samuelkunsaukaАй бұрын
This is smart job. Keep it up
@DNC2.0Ай бұрын
Thanks, will do!
@thierrymukadi64752 күн бұрын
Good job and thanks
@DNC2.0Күн бұрын
Thank you too, and you're welcome
@pamprorecords24402 ай бұрын
wow great job, it’s very great. Please can you lead me a little on how you made the holes in the bricks to be able to fix the iron bars on them? And what kind of bricks are they exactly? thank you and I can't wait to see your response
@DNC2.02 ай бұрын
The bricks are custom made cement bricks with a length of 40cm, width of 16cm and a height of 19cm. To make the bricks you should make a custom made frame using these measurements then then mix the cement with sand and pour it in the frame you made then you take two bolts and put the heads in the wet cement, and measure the distance between the two bolts for consistency on the other bricks. After you made the bricks you measure the point of the two bolts on the bricks and drill the same measurements on the metal bars so that you can easily slide it in then tightening it with a nut securely. Alright i guess that answers your question and thanks for the positive comment by the way. Peace out✌️
@pamprorecords2440Ай бұрын
Thank you for your reply @@DNC2.0
@yahayajamiu90412 ай бұрын
This is a very good job. Please what is the name of the terminal you linked all the batteries to called? Made the installation so neat and free of cable joints
@DNC2.02 ай бұрын
Its a 4 post power distribution busbar. You can search it on Google for more information, and thanks for the comments
@nnekaenweliku917Ай бұрын
Good job guys. I appreciate the simplicity and neatness of the job. I'm thrilled with the panel installation especially that you had everything custome made and easy to install. A quick question though, how did you fix the concrete or brick to the roof floor? Wish you were in Nigeria.
@DNC2.0Ай бұрын
Thanks bro really appreciate it. The concrete bricks aren't fixed to the roof floor but instead we just placed it because the weight of all the concrete bricks combined is enough to securely hold the panels.
@IngBey-5710Ай бұрын
Nice job
@DNC2.0Ай бұрын
Thanks
@bergertshitenge137529 күн бұрын
I really appreciated your installation, it's great especially the PV support used, is it possible to share with us the lengths of your PV supports and the weight of the concrete blocks used. I am also an engineer in the solar field thank you
@DNC2.022 күн бұрын
Yes, of course Oh alright thats pretty cool the dimensions of the frame are as follow. The Base angle bar is 1m 76cm, the long vertical angle bar is 80cm, the shorter angle bar is 40cm, and the top sloping angle bar is 1m 76cm. Keep in mind that the panels we use are 1m 96cm × 1m6cm alright i hope that helps
@savageolatunde6731Ай бұрын
Good job
@DNC2.0Ай бұрын
Thanks
@aglactv7893Ай бұрын
Neat job but the DC cable size for the Battery Bank is too small, cable size for the 3 battery set up should not be less than 50mm-75mm.....because when the battery is drain and is set to charge the cable temperature will slightly increase and might not the able to withstand the charging current of the 3 storage devices
@DNC2.022 күн бұрын
Thanks bro
@lukeaaronpower448Ай бұрын
Good installation work Sir . Out of curiosity which Installation regulations did you use to install this system ? I might have few questions i need to ask
@muhammadriaz634110 күн бұрын
❤ Excellent 👌
@DNC2.010 күн бұрын
Thank you! Cheers!
@muhammadriaz634110 күн бұрын
@@DNC2.0 you are welcome to Pakistan 🇵🇰
@dannyoliver7953Ай бұрын
Gm can you give me some measurement and the solar rocking system plus the dimension of the solar panel. I would appreciate it thank you.
@DNC2.0Ай бұрын
The dimensions of the solar panels are 1960×1060×35mm or 196×106×3.5cm
@Sindhu_JattАй бұрын
*Waaooo Nice work. But there is no gap between the panels, a strong wind can pulled it out.*
@DNC2.022 күн бұрын
Thanks mate, I don't think it can
@benedictokpala5846Ай бұрын
Great job bro. Please which software did you use for the wiring diagram ?
@DNC2.0Ай бұрын
I didn't use any software for the wiring diagram. I draw it myself
@dannyoliver7953Ай бұрын
Could you tell me were you getting grounded mount for panels from also solar panels
@DNC2.0Ай бұрын
They were custom made bricks with bolts sticking out to easily tighten the metal frames on the bricks
@atobskyАй бұрын
I did not see an RCD anywhere in your installation ? Well laid out installation
@DNC2.0Ай бұрын
The RCD is installed in the main distribution box which unfortunately wasn't shown on camera
@atobskyАй бұрын
@@DNC2.0 Even at that , the inverter should have its own RCD and this is important to show in your installation videos so viewers are convinced you know what you are doing and that you take safety importantly...there should be an RCD , a Type B or Type F , after the inverter before the Distribution Board
@OpsolarАй бұрын
Naija una too the find error abeg
@atobskyАй бұрын
@@Opsolar it is from the errors and feedback, improvement and better delivery of service is generated... Errors and feedbacks are beautiful things
@pipoy4886Ай бұрын
syperb work brother. There is no SCC in your set up. as i understand the solar is directly connected to your inverter and the inverter has battery port for its dc output?
@DNC2.0Ай бұрын
Thanks for the comment mate. The panels are not directly connected to the inverters but instead they're connected to a Surge Protective Device first before reaching the inverters
@pipoy4886Ай бұрын
@@DNC2.0 i see. thats what im talking about there is only protective device between the two. kudos
@ekedonz12 күн бұрын
Why did u use 2 dc breaker for the pv. Why not go straight to the surge protector then to the breaker which will pass to the inverter. I don't mean to challenge. I'm always trying to learn.
@DNC2.010 күн бұрын
Thanks bro for the positive energy. Yeah the first DC breaker serves as a fuse to protect the inverters from over voltage ⚡️ from the panels incase of surge,and the second one just serves the purpose of an isolator
@venceslaswembenyui1551Ай бұрын
i really did enjoy the work but please can you help me with the calculation steps
@DNC2.0Ай бұрын
Which calculations are you refering to
@elvisbestroyal80Ай бұрын
In the setup was each inverter and battery connected to separate loads in the house Like each controls his own load ?
@DNC2.0Ай бұрын
No the the inverters were connected in parallel to increase the overall output power and the batteries as well were connected in parallel to increase the overall capacity. They are all collectively controlling one big load
@elvisbestroyal80Ай бұрын
@DNC2.0 oh I see. Thank you
@mauriceamollo8538Ай бұрын
Did you wire the batteries in parallel or series? what are the capabilities per batteries?
@DNC2.0Ай бұрын
We wire the batteries in parallel to increase the overall capacity. Each battery is powerful enough to power a small house
@dannyoliver7953Ай бұрын
Thanks for the help?if you can get the custom metal frame dimensions that holds solar panels.I’ll pay you for it, I’m trying to setup like yours
@DNC2.0Ай бұрын
Oh alright thats pretty cool the dimensions of the frame are as follow. The Base angle bar is 1m 76cm, the long vertical angle bar is 80cm, the shorter angle bar is 40cm, and the top sloping angle bar is 1m 76cm. Keep in mind that the panels we use are 1m 96cm × 1m6cm alright and no need for you to pay bro am here to help anytime you need me
@odoohub5010Ай бұрын
I wss expecting you use ferrules to avoid loose contacts over time
@fortniegodking5776Ай бұрын
what type of inverter did you use and what's the spec of them. Thanks
@DNC2.022 күн бұрын
It's a 5000W, 48V, 119A Felicity inverter
@ChandrashekarCN2 ай бұрын
💖💖💖💖
@DNC2.02 ай бұрын
Thanks mate
@latifsalehadam715 күн бұрын
Hi bro , here at the end , all 3 inverter output is connected in paralel to distribution box ??
@DNC2.04 күн бұрын
Yeah all the inverters are connected in parallel then to the distribution board
@latifsalehadam714 күн бұрын
So all 3 inverter give single phase 220v , what about if i connected each inverter to its single phase so i get use in 3phase house . Is it possible ?
@NetZeroghana19 күн бұрын
Beautiful, which country?
@DNC2.019 күн бұрын
Gambia 🇬🇲
@IEJonahАй бұрын
Do you carry out work in lagos??... and also how much will the 15kwh battery cost now?
@DNC2.0Ай бұрын
We are located in the Gambia but if you need our service we can come and install for you. The batteries are each costing about $1810 you can check it on alibaba for more information
@user-ph6cp2ox7u18 күн бұрын
Please the pv is it potential voltage or different things
@DNC2.017 күн бұрын
I don't understand the que3
@CARWASHVIDEO-bs4jtАй бұрын
NICE🥰🥰
@DNC2.0Ай бұрын
Thanks
@sunenergytechnologies4918Ай бұрын
why you use dual breaker with SPD.. ? instead of single
@DNC2.0Ай бұрын
We use it for added protection
@i-TEQ_powerАй бұрын
You should have used double SPD instead, if you are actually keen on Added protection. Peace!!!
@abumahraz5948Ай бұрын
Abeg my question is, Does inverter has efficiency rating like d way panel does? E.g I can only get 3kva from an inverter of 5kva? Clean installation guys, gudus👏
@DNC2.0Ай бұрын
No you can't get up to 5000W in a 5KW inverter because you have to take into consideration the power factor which most inverters have 80 percent of or 0.8
@meilyn22Ай бұрын
They aren't 100% efficient, just FYI. Most of them are around 90-94%, efficient, which is good.
@meilyn22Ай бұрын
They also have continous and surge ratings. Inverters lose efficiency because of heat, conversions, and how much power they take to run. A 5kva inverter can never give you 5kva. The highest it can produce at its best is 4.5 - 4.8kva. Except the manufacturer is accounting for those inefficiencies.
@meilyn22Ай бұрын
Knowing Felicity, I can tell you their claims are mostly BS. So their inverters will be less than 90% efficient. They aren't honest.
@atobskyАй бұрын
Any appliance rated in KVA is just a marketing strategy to make the appliance look bigger than what it actually is, after all, your TV eg is not rated in " KVA but WATT... Most KVA rated inverters have a power factor of 0.8 so, for example , an inverter rated at 5KVA PEAK WILL PROBABLY BE A 4KW or 4000Watts .... So when buying inverters , look out for the ones in Watts not KVA. Most inverters made in Europe or for European Markets are rated in WATTS and they also come at huge prices
@sunenergytechnologies4918Ай бұрын
is this right angle ..? for opposit pannels
@DNC2.0Ай бұрын
Yeah we carefully studied the movement of the sun to efficiently install the panels to harvest maximum sun rays
@Ghedi1965Ай бұрын
could you please share the 15kw package contents?
@DNC2.0Ай бұрын
We bought 24 panels of 450W. 3 inverters of 5KW to be later connected in parallel to increase the overall output power to 15KW. 3 batteries of 15KWH 51.2V each to be also connected in parallel
@MsLewiskyАй бұрын
Plz how can I get that bus bar for battery
@DNC2.0Ай бұрын
You can get it by ordering it on the interet or getting it from an electrical shop
@theo2378Ай бұрын
Where was this installed?
@DNC2.022 күн бұрын
In the Gambia 🇬🇲
@user-kw4fq5hj3zАй бұрын
The company specializes in the production of solar photovoltaic bracket galvanized pipes, durable and anti-corrosion, with a service life of up to 25 years, good quality and low price. Welcome to cooperate.
@DNC2.0Ай бұрын
Thanks mate 👍
@mauriceamollo8538Ай бұрын
What is the size per batteries?
@DNC2.0Ай бұрын
The Batteries are 15KWH 51.2V lithium ion batteries
@mauriceamollo8538Ай бұрын
So how many solar panels are needed to charge one batterie in this setup?
@Mr-NunАй бұрын
Neatly done job. ❤ how can I contact you for a jobs in Lagos Nigeria.
@DNC2.0Ай бұрын
We're located in the Gambia 🇬🇲
@AnsoumanaBiaye-ej1jnАй бұрын
Vous êtes dans quel pays
@DNC2.0Ай бұрын
Am in a country called Gambia 🇬🇲
@JosephMarambaАй бұрын
How much for this exact system
@DNC2.0Ай бұрын
I don't really know the answer to that because the home owner ordered the materials from china
@obichukwuebukajames1209Ай бұрын
Are u guys in Nigeria??
@DNC2.0Ай бұрын
No we are located in the Gambia
@adewumisesan26Ай бұрын
You made a mistake why are you still backing your battery with external breaker what of if the breaker trip off it will remain only PV voltage on the system are you know only PV voltage can damage the system without seen battery
@chiemezieanaebonam989826 күн бұрын
Not a mistake This is Ivem that means it can work without batteries External breakers are recommended by the manufacturer
@DNC2.022 күн бұрын
Thanks mate
@DNC2.022 күн бұрын
You can even use only the panels without batteries with these inverters. The Batteries are just there to store energy which is to be used later on.
@gitsingelenaratsadaolur4819Ай бұрын
DC 😊Cable connectıon not safe
@azisebance722227 күн бұрын
Sono molto fiero di voi bravi fratelli miei
@DNC2.022 күн бұрын
Thanks am proud of you too✌️💯
@19827572 ай бұрын
where are you located
@DNC2.02 ай бұрын
Am from the Gambia 🇬🇲
@technotemkaАй бұрын
Колхозят, где опрессовка или пайка? 😢
@DNC2.0Ай бұрын
Soldering was not needed but crimping was done behind the scenes
@onimisilovesonmusic4548Ай бұрын
Ur panels will have too many shades
@odoohub5010Ай бұрын
How
@plantsolar1436Ай бұрын
inverter should not attached close to wall
@DNC2.0Ай бұрын
Thanks bro
@HeimatarАй бұрын
Yes it should
@HeimatarАй бұрын
And they made relatively safe distance from each other
@HeimatarАй бұрын
This is bad because only 1 inverter was enough with those amount of solar arrays the customer trusted you and your calculation otherwise good job.
@OpsolarАй бұрын
No 1 inverter isn't enough, the building has a lot of loads and getting an higher inverter will require 96v
@HeimatarАй бұрын
@Opsolar what on earth will he use more than 22 amp and continues 5kw in home residence
@aidamacayan43021 күн бұрын
Not good installation not using terminal lugs no quality. Trash bin