intellipack P.M. and controls overview

  Рет қаралды 9,998

Everything HVACR

Everything HVACR

Күн бұрын

hvac, trane intellipack and controls explained

Пікірлер: 77
@madeveric22
@madeveric22 3 жыл бұрын
Nice PM I thought we did good pms but yours is 🔥🔥🔥
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Thank you!
@bhunter3850
@bhunter3850 3 жыл бұрын
Thanks for showing us the PM. And thanks for tip about using rubber tubing to prevent rub outs.
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Thanks for watching!
@johnwaby4321
@johnwaby4321 3 жыл бұрын
Brilliant view. . All looking nice and clean now .. saves you having any problems later on 👍👍
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Thanks man!
@hkhsm359
@hkhsm359 3 жыл бұрын
Nice job. Keep posting videos. Thanks for sharing
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Thanks man!
@jimmyp5487
@jimmyp5487 3 жыл бұрын
Sweet pm Wish all customers with pay the money to keep their equipment up to standards... some do others don’t but pay more in the long run. Keep the videos rollin brotha. stay safe 🤘🤘🇺🇸🇺🇸
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Thanks for watching! It is nice when equipment is well taken care of.
@Stickboibx
@Stickboibx 3 жыл бұрын
Great video! I work at the facility that produces this unit.
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Nice, thanks for the support! Keep doing what you do, these are well built units 💪👏
@rgmALC
@rgmALC 3 жыл бұрын
I’m a service tech for Trane. You covered everything pretty well....good job!
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Thanks man, we do a lot of trane, where you from
@rgmALC
@rgmALC 3 жыл бұрын
@@EverythingHVACR New Hampshire. Intellipaks are intimidating at first - I still spend time with tech support going over sequence. But you seem to be comfortable with them. As much as there is going on with them, a fully decked out Precedent (all motors on drives, re-heat, reversing valves, etc) is 100x more confusing!!
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Nice! have worked with some of the harshaw guys down here in KY, my company works with trane as well. Thank you for the support!
@arielhernandez2911
@arielhernandez2911 2 жыл бұрын
Ima have to steal that Vicky tubing idea
@EverythingHVACR
@EverythingHVACR 2 жыл бұрын
Do it Ariel Hernandez! It works 💪
@markbell6864
@markbell6864 3 жыл бұрын
Great pm on an IntelliPak👍
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Thank you sir!
@refrigerationconfidential4376
@refrigerationconfidential4376 3 жыл бұрын
Very thorough awesome stuff
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Thanks man!
@hvacslayer2929
@hvacslayer2929 3 жыл бұрын
Looks like not too much has changed with the intellipaks. Hopefully they changed the paint coat and doesn’t get all chalky turning you into a powder donut. Dumb idea to have contactors in a separate box I’ve seen older mcquays like that were they are underneath the comps in a control box. Still same user control module has the 2000’s year makes that I have. Watching you spray the compressors made me flitch I’ve had crankcase heaters pop on me when getting some water on them 😂 Guessing it isn’t code to drain into the roof drains over there? Also noticed on some of your zones, the boxes completely close up near setpoint. Here we have our mins and max we have to have ventilation so min would be like 150 cfm depending on box size. We got audited by UL on our RTU and some areas through out the building, lol let’s just say some interesting data and comfort for customers isn’t there priority.
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
I am not a fan of the contactors moving either, this was the first time I've seen that, so must be on the new models. Your right, Roof drains are not code here. As far as the box minimum, harshaw actually set this up and now we have the contract. Anyway I didn't mess with much air flow, I will adjust min and max when needed but a few vav only feed 1 small office on the Interior so 150cfm may be too much, hard to say but first time p.m. I didn't want to throw everything out of whack so only a few slight adjustments. Many more will need to be made in the future to fine tune everything. I spoke to the customer about this and they understand. But to keep this short there were other issues that were going on, some things just were not right, addresses on boxes, stats in wrong area ect. Thanks for watching!
@user-mb5cr1ts8g
@user-mb5cr1ts8g Жыл бұрын
Nice you have a computer to check unit my company don’t give us nothing
@neilvestervictor180
@neilvestervictor180 3 жыл бұрын
great job on this video
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Thanks man!
@alwayslost3008
@alwayslost3008 3 жыл бұрын
I like to use a vacuum cleaner for drain pans if they that dirty. I think, but stand corrected, the moved the larger contractors because it could interfere with low voltage control signals esp com signals.
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Any way you do these intellipack units is a pain, you just can't access the drain pan well.
@alwayslost3008
@alwayslost3008 3 жыл бұрын
@@EverythingHVACR I live in South Africa. we don't have the same equipment that you guys have over there. Our regulations arn't as strict as the US. Africa is in short the dumping ground for out of date and equipment that don't meet the 1st world regulations. Eventually those type of units will become available here.
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
These units are reliable and work great especially in large office buildings with multiple rooms and offices, intellipack VAV is the way to go. Thank you for your support!
@jeffleffel4905
@jeffleffel4905 2 жыл бұрын
Surprised a “super tech” hasn’t come at you about spraying the coils from the outside lol I hit it just like you do at an angle. Only thing different I’ve done is getting rid of those grease lines all together… your already walking around in there hit it at the bearing itself and wipe off the excess grease. Do you take out the plugs and put grease fittings on the motors?
@EverythingHVACR
@EverythingHVACR 2 жыл бұрын
😆 Thanks Jeff! If the coil is clean it's clean. Eventually the motors may need grease but if you look at manufacturer data on the motors, usually a few years normal duty before I would consider greasing.
@dirtydan678
@dirtydan678 Жыл бұрын
What kind of nozzle do you use on the hose? Water pressure isn't the best at my building, anything would help. Thanks!
@EverythingHVACR
@EverythingHVACR Жыл бұрын
It's a bullseye nozzle, it helps. but with really bad water pressure, you could use a booster pump to help.
@dirtydan678
@dirtydan678 Жыл бұрын
@@EverythingHVACR thank you!
@EverythingHVACR
@EverythingHVACR Жыл бұрын
No problem, thank you, dirtydan!
@simohvac9222
@simohvac9222 3 жыл бұрын
great PM
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Thanks man!
@xraybravo7180
@xraybravo7180 Ай бұрын
I have an intellipack that has 6 compressors only 2 large ones are on and I'm not sure what the small compressor do and when and how they come on ? Stage- 1 3 compressor only 1 runs 2 stand by contsctors don't close for them. Stage -2 3 compressor. It's same as one for this one.
@EverythingHVACR
@EverythingHVACR Ай бұрын
Is it maintaining supply air temperature? Are there any alarms? If there are no alarms and it's maintaining supply air temperature, it may not stage up.
@xraybravo7180
@xraybravo7180 Ай бұрын
@@EverythingHVACR It says RTM ? Supply air temp input 57 °F
@xraybravo7180
@xraybravo7180 Ай бұрын
@EverythingHVACR how to test them to run ? In test mode ?
@EverythingHVACR
@EverythingHVACR Ай бұрын
You should be able to test them via the HMI.
@stevem9629
@stevem9629 3 жыл бұрын
👍
@PBS-nm1uu
@PBS-nm1uu 2 жыл бұрын
do you have any videos on sequence of operation. ???
@EverythingHVACR
@EverythingHVACR 2 жыл бұрын
Good question PBS! Not specifically on the intellipack, though I have a few more videos on intellipack units. A more recent video shows diagnosis of the burner control.
@EverythingHVACR
@EverythingHVACR 2 жыл бұрын
kzfaq.info/get/bejne/fbt5epiT3am9oYU.html
@geraldschilli8870
@geraldschilli8870 3 жыл бұрын
Suggestion; when needed, replace the plastic grease tubing with copper tubing. Problem solved.
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
That is a great idea, I'll keep that in mind Thanks for watching!
@benjaminmeester7557
@benjaminmeester7557 6 ай бұрын
hello, what software are you using to access the intelipak like that?
@EverythingHVACR
@EverythingHVACR 6 ай бұрын
Tracer TU software is connected to the main SC controller. It does require a license through trane. Most adjustments, if needed, can be done from the HMI at the intellipack.
@benjaminmeester7557
@benjaminmeester7557 6 ай бұрын
@@EverythingHVACR thank you. my new employer has an intellipack so im brushing up on them, but they dont have the software so thats my next move.
@EverythingHVACR
@EverythingHVACR 6 ай бұрын
It may have a front end or a main computer connected to the building that you can view and make adjustments. The software probably has a few extra benefits, but for the most part, you could make any necessary adjustments from this computer. Understanding VAV system operations is a must, more so than the software.
@jonnymac31
@jonnymac31 3 жыл бұрын
Yeah man
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Thanks John!
@gr8gmblr
@gr8gmblr 3 жыл бұрын
Cool, thanks for sharing. But rinsing the condenser coil will not cause a high pressure fault.it Might cause less dehumidification.
@jfrancis98
@jfrancis98 3 жыл бұрын
Micro channel coils will when full of water
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Truth, thanks HVACtech!
@leifhoganson6996
@leifhoganson6996 3 жыл бұрын
@Everything HVAC, do you perform RTU maintenance in the rain?
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Depends on how bad the rain and what I have to do. Stay out of electrical, obviously, but rinsing coils or drains can be accomplished safely, if you have to but Once you've done it for a while it's easy enough to watch the weather and plan accordingly! Thank you for your support!
@mauricekendallii3658
@mauricekendallii3658 3 жыл бұрын
What tonnage is that?
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
80 to 100 tons, not 100% sure. Serves a 4 story office building.
@Jamie-po9zk
@Jamie-po9zk 3 жыл бұрын
what kind of hose attachment are you using?
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
What do you mean "attachment" to what?
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
Not sure how I misread this, it's called a bullseye, simple and effective. My favorite nozzle to use
@user-rw6gs6hq7c
@user-rw6gs6hq7c 9 ай бұрын
I have this intelipack i can't find zone sensor . I looked behind fan compartment found nothingn
@EverythingHVACR
@EverythingHVACR 9 ай бұрын
There is not a single zone sensor. This is a vav system, so each vav has a zone sensor that controls the space temp using the vav box. The intellipack only maintains a constant supply temperature and duct static pressure.
@user-rw6gs6hq7c
@user-rw6gs6hq7c 9 ай бұрын
@EverythingHVACR under what menus can I find that constant supply tempreture. It's controlled by backnet and company who monitors it is unknown.
@user-rw6gs6hq7c
@user-rw6gs6hq7c 9 ай бұрын
@@EverythingHVACR Controlling sensor sub menus-> RTM Supply air input is: 59F. Active daytime WU temp sensor input from bas network: 69.1F.
@EverythingHVACR
@EverythingHVACR 9 ай бұрын
Supply air input is the supply temperature. Daytime warm up is a sensor in the space to allow Daytime warm up if needed. What is the problem here? You may need to read over the manual to understand the operation better.
@jasonjohnsonHVAC
@jasonjohnsonHVAC 3 жыл бұрын
Thats a big unit. How many tons?
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
100 tons, may be slightly bigger dont know the exact BTU but yes it is a biggun. Thanks for watching!
@jasonjohnsonHVAC
@jasonjohnsonHVAC 3 жыл бұрын
@@EverythingHVACR ya I'd say thats pretty big.
@geraldschilli8870
@geraldschilli8870 3 жыл бұрын
Condensate draining directly out onto the roof is definitely against mechanical codes. Whoever the installation contractor was needs to be called out about this issue.
@EverythingHVACR
@EverythingHVACR 3 жыл бұрын
That is not code where I am. Thanks for watching!
Intellipack no cool service call but where is the problem
15:20
Everything HVACR
Рет қаралды 3 М.
HVAC cooling season, rooftop unit p.m tips, tricks and what to look for
19:12
Running With Bigger And Bigger Feastables
00:17
MrBeast
Рет қаралды 165 МЛН
Пройди игру и получи 5 чупа-чупсов (2024)
00:49
Екатерина Ковалева
Рет қаралды 4,3 МЛН
OMG what happened??😳 filaretiki family✨ #social
01:00
Filaretiki
Рет қаралды 13 МЛН
A Tour of a Trane Self-contained Intellipak EP59
12:26
Nighthawk HVAC
Рет қаралды 2,5 М.
Commercial HVAC Preventative Maintenance
16:34
HughesMan HVAC
Рет қаралды 26 М.
Water Source Heat Pump Not Cooling.  How to Diagnose. EP67
13:17
Nighthawk HVAC
Рет қаралды 14 М.
HVAC | AC  TROUBLESHOOTING
12:57
D2D NY Real World HVAC Simplified
Рет қаралды 2 М.
HVAC TROUBLESHOOTING
23:18
D2D NY Real World HVAC Simplified
Рет қаралды 12 М.
Cooling Tower PM Basic's HVAC Training for HVAC Technician
34:57
Air Conditioning isn't free... but we're close.
25:45
Tech Ingredients
Рет қаралды 1,1 МЛН
TRANE VOYAGER NOT COOLING
23:21
HVACR VIDEOS
Рет қаралды 119 М.
VAV Variable Air Volume - HVAC system basics hvacr
13:53
The Engineering Mindset
Рет қаралды 1 МЛН